    Subcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial

    by Reinoud E. Knops, Christelle Marquie, Peter Nordbeck, Roland Tilz, Leonard A. Dijkshoorn, Anne-Floor B.E. Quast, Tom F. Brouwer, Pier D. Lambiase, Christopher Cassidy, Lucas V.A. Boersma, et al.

    Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).


  • Open Access

    Device-Related Complications in Transvenous Versus Subcutaneous Defibrillator Therapy During Long-Term Follow-Up: The PRAETORIAN-XL Trial

    by Louise R.A. Olde Nordkamp, Jolien A. de Veld, Abdul Ghani, Jürgen Kuschyk, Hendrik Bonnemeier, Kerstin Bode, Lucas V.A. Boersma, Anouk de Weger, Jonas S.S.G. de Jong, Ward P.J. Jansen, et al.

    BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) investigated the efficacy and safety of the subcutaneous implantable cardioverter defibrillator (S-ICD) compared with a transvenous ICD (TV-ICD) and showed noninferiority of the S-ICD with regard to the composite end point of device-related complications and inappropriate shocks after 49.1 months. Complications associated with transvenous leads are expected to occur after longer follow-up. The PRAETORIAN-XL trial aims to investigate whether the S-ICD is superior to the TV-ICD with respect to device-related complications at 8-year follow-up. METHODS: The PRAETORIAN trial randomized patients with a class I or IIa indication for ICD therapy without the need for pacing to either S-ICD or TV-ICD among 39 centers in the United States and Europe between March 2011 and January 2017. The follow-up was extended after 49.1 months by an additional 4 years for the PRAETORIAN-XL trial. The primary end point was the composite of all device-related complications. Complications could be related or unrelated to the lead and minor or major, with major complications being those requiring an invasive intervention. End points were analyzed according to the modified intention-to-treat principle using a Fine-Gray subdistribution hazards model to account for competing risks. An as-treated analysis was performed using a Cox proportional hazards model with device type as time-dependent variable. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). Twenty-one percent of the S-ICD group versus 18% of the TV-ICD group were women. The median age at implantation was 63 (interquartile range, 54–69) years for the S-ICD and 64 (interquartile range, 56–69) years for the TV-ICD. After a median follow-up of 87.5 months, all device-related complications (major and minor combined) were not significantly different in the modified intention-to-treat analysis (subdistribution hazard ratio, 0.73 [95% CI, 0.48–1.12]); P =0.15). However, TV-ICD patients more often had a major complication or lead-related complication ( P =0.03 and P P =0.047). CONCLUSIONS: The PRAETORIAN-XL trial demonstrated that there was no significant difference between the S-ICD and TV-ICD in all device-related complications during long-term follow-up. However, the TV-ICD carries a higher risk of major and lead-related complications compared with S-ICD therapy. The S-ICD should therefore be considered for all patients without a pacing indication who are evaluated for ICD therapy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.


  • Open Access

    Inappropriate Therapy and Shock Rates Between the Subcutaneous and Transvenous Implantable Cardiac Defibrillator: A Secondary Analysis of the PRAETORIAN Trial

    by Louise R.A. Olde Nordkamp, Shari Pepplinkhuizen, Abdul Ghani, Lucas V.A. Boersma, Juergen Kuschyk, Mikhael F. El-Chami, Elijah R. Behr, Tom F. Brouwer, Stefan Kääb, Suneet Mittal, et al.

    BACKGROUND: Inappropriate therapy (IAT) is an undesirable side effect of implantable cardiac defibrillator (ICD) therapy. Early studies with the subcutaneous ICD (S-ICD) showed relatively high inappropriate shock (IAS) rates. The PRAETORIAN (Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) trial demonstrated that the S-ICD is noninferior to the transvenous ICD (TV-ICD) with regard to the combined end point of IAS and complications. This secondary analyses evaluates all IAT in the PRAETORIAN trial. METHODS: This international, multicenter trial randomized 849 patients with an indication for ICD therapy between S-ICD (n=426) and TV-ICD therapy (n=423). ICD programming was mandated by protocol. All analysis were performed in the modified intention-to-treat population. RESULTS: In both groups 42 patients experienced IAT (48-month Kaplan-Meier estimated cumulative incidence, 9.9% and 10.1%, respectively; hazard ratio (HR), 0.99 [95% CI, 0.65–1.52]; P =0.97). There was no significant difference in patients experiencing IAS between both groups ( P =0.14). In the S-ICD group, 81 IAT episodes with 124 IAS and 1 inappropriate antitachycardia pacing occurred versus 89 IAT episodes with 130 IAS and 124 inappropriate antitachycardia pacing in the TV-ICD group. IAT episodes were most frequently caused by supraventricular tachycardias in the TV-ICD group (n=83/89) versus cardiac oversensing in the S-ICD group (n=40/81). In the TV-ICD group, a baseline heart rate >80 bpm (HR, 1.99 [95% CI, 1.05–3.76]; P =0.03), a history of atrial fibrillation (HR, 2.66 [95% CI, 1.41–5.02]; P =0.003), and smoking (HR, 2.46 [95% CI, 1.31–4.09]; P =0.005) were independent predictors for IAT. A QRS duration >120 ms was an independent predictor for IAT caused by cardiac oversensing in the S-ICD group (HR, 3.13 [95% CI, 1.34–7.31]; P =0.008). Post-IAS interventions significantly reduced IAS recurrence in both groups ( P =0.046). CONCLUSIONS: There was no significant difference in IAT and IAS rates between the S-ICD and TV-ICD in a conventional ICD population, but causes and predictors for IAT differed between the devices. After the first IAS, an intervention significantly reduced the recurrence rate of IAS. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.


  • Open Access

    Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial

    by Reinoud E. Knops, Jolien A. de Veld, Abdul Ghani, Lucas V.A. Boersma, Juergen Kuschyk, Mikhael F. El Chami, Hendrik Bonnemeier, Elijah R. Behr, Tom F. Brouwer, Stefan Kääb, et al.

    BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022.


  • Open Access

    Evaluation of the introduction of a single-lead ECG device and digital cardiologist consultation platform among general practitioners in the Netherlands

    by Evert P.M. Karregat, Marlou A. de Koning, Jelle C.L. Himmelreich, David W. Koetsier, Jonas S.S.G. de Jong, Eric P. Moll van Charante, Ralf E. Harskamp, Wim A.M. Lucassen

    Aim: To evaluate the use of a single-lead electrocardiography (1L-ECG) device and digital cardiologist consultation platform in diagnosing arrhythmias among general practitioners (GPs). Background: Handheld 1L-ECG offers a user-friendly alternative to conventional 12-lead ECG in primary care. While GPs can safely rule out arrhythmias on 1L-ECG recordings, expert consultation is required to confirm suspected arrhythmias. Little is known about GPs’ experiences with both a 1L-ECG device and digital consultation platform for daily practice. Methods: We used two distinct methods in this study. First, in an observational study, we collected and described all cases shared by GPs within a digital cardiologist consultation platform initiated by a local GP cooperative. This GP cooperative distributed KardiaMobile 1L-ECG devices among all affiliated GPs (n = 203) and invited them to this consultation platform. In the second part, we used an online questionnaire to evaluate the experiences of these GPs using the KardiaMobile and consultation platform. Findings: In total, 98 (48%) GPs participated in this project, of whom 48 (49%) shared 156 cases. The expert panel was able to provide a definitive rhythm interpretation in 130 (83.3%) shared cases and answered in a median of 4 min (IQR: 2–18). GPs responding to the questionnaire (n = 43; 44%) thought the KardiaMobile was of added value for rhythm diagnostics in primary care (n = 42; 98%) and easy to use (n = 41; 95%). Most GPs (n = 36; 84%) valued the feedback from the cardiologists in the consultation platform. GPs experienced this project to have a positive impact on both the quality of care and diagnostic efficiency for patients with (suspected) cardiac arrhythmias. Although we lack a comprehensive picture of experienced impediments by GPs, solving technical issues was mentioned to be helpful for further implementation. More research is needed to explore reasons of GPs not motivated using these tools and to assess real-life clinical impact.


  • Open Access

    Women Have More Recurrences of Atrial Fibrillation than Men after Thoracoscopic Ablation and Suffer More from Established Risk Factors

    by Robin Wesselink, Bente Mossink, Eva R. Meulendijks, Nicoline W. E. van Den Berg, Jolien Neefs, Makiri Kawasaki, Benedetta Fabrizi, Femke R. Piersma, Rushd F. M. Al-Shama, Tim A. C. de Vries, et al.

    Introduction. Atrial fibrillation (AF) is more prevalent in men than in women. However, women with AF are more symptomatic, have a worse quality of life, a higher stroke risk and may therefore benefit most from ablation. In this study we aim to identify the risk of recurrent AF after thoracoscopic ablation, and assess the differential impact of the risk factors for recurrence between women and men. Method. This is a single center cohort study, including patients undergoing thoracoscopic ablation for advanced AF between 2008 and 2019. All patients were clinically followed up for two years with quarterly 24 h Holter monitoring and ECGs for the detection of recurrent AF. Left atrial appendage (LAA) tissue was collected for collagen analysis. Results. We included 571 patients, of whom 143 (25%) were women. Women were older than men (63 ± 8.3 y vs. 59 ± 8.5, p < 0.001), but had fewer cardiovascular risk factors, myocardial infarctions (1.4% vs. 6.5%, p = 0.03) and, in particular, vascular disease (7.0% vs. 16.1%, p = 0.01). Women suffered more from AF recurrence, driven by more atrial tachycardias, and sex was an independent risk factor for recurrence (HR1.41 [1.04–1.91], p = 0.028]). The presence of vascular disease was associated with an increased risk for AF recurrence in women, but not in men. In LAA histology, women had more collagen than men, as had patients with persistent compared to paroxysmal AF. Conclusion. Women had 15% more recurrences, driven by more atrial tachycardias, which may be explained by a more fibrotic atrial substrate. What’s new? Women undergoing thoracoscopic AF ablation have a higher risk of recurrent AF, driven by more atrial tachycardias. Among patients with left atrial enlargement or persistent AF, women have worse outcomes than men. Vascular disease was a risk factor for recurrence in women, but not in men. In a histopathologic analysis of the left atrial appendage, women had more collagen than men, as had patients with persistent compared to paroxysmal AF.


  • Open Access

    Device-related complications in subcutaneous versus transvenous ICD: a secondary analysis of the PRAETORIAN trial

    by Reinoud E Knops, Shari Pepplinkhuizen, Peter Paul H M Delnoy, Lucas V A Boersma, Juergen Kuschyk, Mikhael F El-Chami, Hendrik Bonnemeier, Elijah R Behr, Tom F Brouwer, Stefan Kaab, et al.

    The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice. Shown is the summary of the main endpoints of the manuscript: device-related complications in the subcutaneous and transvenous ICD: a secondary analysis of the PRAETORIAN trial. ICD, implantable cardioverter-defibrillator.


  • Open Access

    Determinants of label non-adherence to non-vitamin K oral anticoagulants in patients with newly diagnosed atrial fibrillation

    by J Seelig, E M Trinks-Roerdink, G Chu, R Pisters, L J H J Theunissen, S A Trines, L Pos, C J H J Kirchhof, S F A M S de Jong, F R Den Hartog, et al.

    To evaluate the extent and determinants of off-label non-vitamin K oral anticoagulant (NOAC) dosing in newly diagnosed Dutch AF patients. In the DUTCH-AF registry, patients with newly diagnosed AF (2, 0.92–0.98), lower weight (OR: 0.98 per kg, 0.97–1.00), active malignancy (OR: 2.46, 1.19–5.09), anaemia (OR: 1.73, 1.08–2.76), and concomitant use of antiplatelets (OR: 4.93, 2.57–9.46). In the 336 (10.3%) patients with a reduced dose NOAC recommendation, 22.9% were overdosed, most often with rivaroxaban. Independent determinants were lower age (OR: 0.92 per year, 0.88–0.96) and lower renal function (OR: 0.98 per ml/min/1.73 m2, 0.96–1.00). In newly diagnosed Dutch AF patients, off-label dosing of NOACs was seen in only 6.6% of patients, most often underdosing. In this study, determinants of off-label dosing were age, renal function, weight, anaemia, active malignancy, and concomitant use of antiplatelets.


  • Open Access

    Strategies for repeat ablation for atrial fibrillation: A multicentre comparison of nonpulmonary vein versus pulmonary vein target ablation

    by Daniel Mol, Mark J. Mulder, Rob Veenstra, Cornelis P. Allaart, Irene E. Hof, Michiel J. B. Kemme, Muchtiar Khan, Geert‐Jan P. Kimman, Gideon Mairuhu, Gijsbert S. de Ruiter, et al.

    Introduction: Approximately 18% of patients with atrial fibrillation (AF) undergo a repeat ablation within 12 months after their index ablation. Despite the high prevalence, comparative studies on nonpulmonary vein (PV) target strategies in repeat AF ablation are scarce. Here, we describe 12 months efficacy of non‐PV and PV target ablations as a repeat ablation strategy.Methods: A multicentre retrospective, descriptive study was conducted with data of 280 patients who underwent repeat AF ablation. The ablation strategy for repeat ablation was at the operators' discretion. Non‐PV target ablation (n = 140) included PV reisolation, posterior wall isolation, mitral line, roofline, and/or complex fractionated atrial electrogram ablation. PV target ablation (n = 140), included reisolation and/or wide atrium circumferential ablation. Patients' demographics and rhythm outcomes during 12 months follow‐up were analyzed.Results: At 12 months, more atrial tachyarrhythmias were observed in the non‐PV target group (48.6%) compared to the PV target group (29.3%, p = .001). Similarly, a significantly higher AF and atrial tachycardia (AT) recurrence rate was observed after non‐PV target ablation compared to PV target ablation (36.4% vs. 22.1% and 22.9% vs. 10.7%). After adjustment, a significantly higher risk of AT recurrence remained in the non‐PV target group. Both groups significantly de‐escalated antiarrhythmic drug use; de‐escalation was more profound after PV target ablation. Patients with isolated PVs during non‐PV target ablation had a significantly higher risk for AF recurrence than those with reconnected PVs.Conclusion: Compared to PV target ablation, non‐PV target repeat ablation did not improve outcomes after 12 months and was independently associated with an increased risk for AT recurrences.


  • Open Access

    Persistent phrenic nerve palsy after atrial fibrillation ablation: Follow‐up data from The Netherlands Heart Registration

    by Daniel Mol, Lisanne Renskers, Jippe C. Balt, Rohit E. Bhagwandien, Yuri Blaauw, Vincent J. H. M. van Driel, Antoine H. G. Driessen, Arif Elvan, Richard Folkeringa, Rutger J. Hassink, et al.

    Background: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP‐related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study.Methods: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow‐up data were collected for patients who developed persistent PNP.Results: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty‐four (0.7%) patients developed persistent PNP and follow‐up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional‐RF, phased‐RF, cryoballoon, and thoracoscopic ablation respectively. Seventy‐one percent of the patients fully recovered, and 86% were free of PNP‐related symptoms after a median follow‐up of 203 (113–351) and 184 (82–359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery.Conclusion: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.