RRRobabeh Rahimi

Robabeh Rahimi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robabeh Rahimi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Applicability of a quantum-inspired genetic algorithm to patient scheduling in radiation oncology

    by Akira SaiToh, Arezoo Modiri, Amit Sawant, Robabeh Rahimi

  • Open Access

    Fractal geometry-governed oxygen diffusion: tumors vs. normal tissues

    by Neda Valizadeh, Robabeh Rahimi, Ramin Abolfath

    Objective. To develop a geometry-governed diffusion framework that explains differential tissue response under FLASH ultra-high dose rate (UHDR) irradiation by explicitly accounting for structural heterogeneity and anomalous transport in biological tissues. Approach. We formulate a generalized diffusion–reaction model on fractal substrates to describe molecular transport in heterogeneous media. Tissue architecture is characterized by a fractal (Hausdorff) dimension D , while scale-dependent transport inefficiency and memory effects are captured by a fractional parameter θ . Analytical solutions for radially symmetric geometries are derived and compared with classical normal (Euclidean) diffusion and a Gaussian reference model under identical physical conditions. Transport behavior is quantified through transient probability distributions and steady-state spatial profiles. Main results. The model reveals systematic suppression of long-range transport and enhanced localization as tissue structural complexity increases. Increasing θ leads to subdiffusive dynamics, reduced effective diffusion lengths, and persistent non-Gaussian concentration profiles, even in the steady state. While increasing D alone enhances spatial accessibility, fractional dynamics dominate transport behavior when θ > 0 , counteracting geometric connectivity. These effects produce a separation between regimes characterized by efficient inter-track overlap and rapid homogenization, and regimes marked by isolated, long-lived reactive domains. Conclusion. Fractal geometry provides a unifying physical framework for understanding tissue-dependent transport and differential response under FLASH UHDR irradiation. Normal tissues, characterized by near-Euclidean geometry and weak anomalous effects, permit greater inter-track interaction and recombination, whereas tumor-like tissues with elevated structural complexity exhibit localized transport and reduced collective chemical reactivity. This proof-of-principle study establishes tissue architecture as a fundamental determinant of transport efficiency and offers a mechanistic basis for experimentally observed FLASH tissue sparing, motivating geometry-aware modeling of radiobiological response. Significance. This work shifts the emphasis from purely chemical kinetics toward a geometry-governed description of oxygen and reactive oxygen species transport in cells and tissues.

  • Open Access

    Defining clinically relevant residual motion for respiratory-gated scanning proton therapy of liver cancer: A patient-derived 4D dynamic dose analysis

    by Yushi Wakisaka, Yuki Tominaga, Mayu Nakata, Robabeh Rahimi, Yuya Miyasaka, Tatsuyuki Higashikawa, Teiji Nishio, Michinori Yamamoto


  • Open Access

    Intermittent patient-specific quality assurance failures in proton therapy attributable to detector calibration drift

    by Yuki Tominaga, Caroline Bamberger, Yushi Wakisaka, Masaaki Takashina, Xing Li, Robabeh Rahimi

    Background: In proton therapy, an out-of-calibration measurement device can intermittently affect patient-specific quality assurance (PSQA) results, and such failures can occur even when routine quality assurance (QA) tests, such as daily and monthly output checks, continue to pass. We retrospectively analyzed PSQA failures in pencil-beam scanning proton therapy with the aim of identifying their root causes and found that repeating measurements with updated device calibration, including output and uniformity, led to improved gamma passing rates, confirming detector calibration as the root cause. Methods: We reviewed two clinical cases from 2022 that failed PSQA, defined as Results: The original 2022 measurements showed higher dose readings than TPS predictions, leading to widespread gamma failures (76–91% passing rates). Repeated measurements with the 2023 and 2024 calibration files yielded high passing rates (97–100%). All plausible causes were systematically evaluated at the time of the failures and no evidence of machine output drift or TPS errors was identified, confirming detector calibration as the root cause. The daily and monthly QA procedures performed with the same device during the failure period did not detect the calibration error, as they used mid-range energies and small fields that did not sufficiently engage the outer ion chambers of the detector. Conclusions: Despite limited machine time in a busy clinic, we recommend periodic functionality checks of the QA detector across energy levels and field sizes, ensuring that both central and peripheral detectors are adequately evaluated.

  • Enhancing proton therapy for superficial lesions using patient-specific bolus and multi-leaf collimator

    by Yushi Wakisaka, Yuki Tominaga, Xing Li, Caroline Bamberger, Jackeline Castro, Kuan Ling Chen, Malgorzata D’SOuza, Robabeh Rahimi

  • Open Access

    Universal Fiducial Markers for Multi-Modal Radiotherapy

    by Jie Liu, Caroline Bamberger, Naveed Iqbal, Kevin Reynolds, Smit Shah, Xing Li, Peng Wang, Jiajin Fan, Ashish Chawla, Kevin Choe, et al.

  • Open Access

    Benchmarking Radiochromic EBT4 Film for Clinical Proton Dosimetry

    by Robabeh Rahimi, Kuan Ling Chen, Jiajin Fan, Rao Khan


  • Open Access

    Radiation incident learning in multi‐site centers

    by Xing Li, Fan‐Chi Su, Qiongge Li, Jiajin Fan, Ashish Chawla, Ann Miner, Robabeh Rahimi

    Purpose: Incident learning in large, multi‐site hospital systems faces challenges from resource constraints, diverse site cultures, and deviations from system‐wide policies. This study introduces a novel, resource‐efficient hybrid approach to facilitate cross‐site learning and proactive risk management, ultimately enhancing patient safety. Methods: A hybrid approach, integrating statistical, and root cause analyses was used to analyze safety events recorded from 2023 to 2024 at five sites. Events were categorized by time, site, type, and harm score with statistics tracking the event frequency per category. Failure modes (FMs) were identified with summative keywords. The frequency and cross‐site correlation of keywords were innovatively displayed by word clouds. The hybrid approach was exemplified at a high‐throughput satellite clinic, where treatments and incidents were tracked quarterly. A proactive model was also employed to predict the number of potentially affected patients at this site. Results: An analysis of 228 reported events revealed that most incidents occurred within the treatment planning category, where the keywords “carepath” and “contour” were identified as the top two frequently reported FMs, repeated 13 and 10 times respectively. The keywords “contour” and “documentation” appeared across four sites, followed by “carepath” and “couch” which appeared across three sites. At the featured satellite clinic, a total of 18 FMs were identified from yearly 8,714 treatments. The proactive model showed an average risk priority number decreased from 106 to 77, and the estimated number of affected patients decreased from 27 to 20 at this site. Conclusions: We developed a comprehensive, system‐wide approach that enhanced efficiency in incident learning across multi‐site clinics. Site‐specific shifts in safety culture were effectively benchmarked and cross‐site learning was facilitated through measurable endpoints. A novel word cloud analysis was developed, enhancing visualization of cross‐site root causes. Additionally, a proactive model was adopted to increase system‐wide preparedness and improve patient safety outcomes.

  • Open Access

    Enhancing inguinal tumor treatment outcomes with a customized 3D‐printed bolus

    by Xing Li, Stephen Bhagroo, Fan‐Chi Su, Robabeh Rahimi, Jonathan Tward

    Traditional boluses for pelvic lesions present challenges, including compromised skin dose coverage from large air gaps in treatment plans and increased uncertainties in treatment delivery due to variations in bolus fitting. This study evaluates the clinical benefits of a patient‐specific, 3D‐printed bolus (pBolus) in external beam radiation therapy (EBRT) for extramammary Paget's disease in the inguinal fold. A three‐dimensional (3D) conformal plan utilizing the pBolus was compared to a conventional Superflab bolus (sBolus) under identical beam arrangements. The pBolus improved dose conformity by reducing air gaps in the treatment plan, and therefore, it was selected for clinical treatment. Weekly setup imaging revealed air gaps predominantly along the inguinal fold, demonstrating overall consistency in bolus fitting with minor air gap variations. Additionally, in vivo dosimetry confirmed dose accuracy. As a result, the patient achieved a favorable outcome, with no clinical evidence of disease at the follow‐up visit.


  • Open Access

    Quantum-Inspired Genetic Optimization for Patient Scheduling in Radiation Oncology

    by Akira SaiToh, Arezoo Modiri, Amit Sawant, Robabeh Rahimi

    Among the genetic algorithms generally used for optimization problems in the recent decades, quantum-inspired variants are known for fast and high-fitness convergence and small resource requirement. Here the application to the patient scheduling problem in proton therapy is reported. Quantum chromosomes are tailored to possess the superposed data of patient IDs and gantry statuses. Selection and repair strategies are also elaborated for reliable convergence to a clinically feasible schedule although the employed model is not complex. Clear advantage in population size is shown over the classical counterpart in our numerical results for both a medium-size test case and a large-size practical problem instance. It is, however, observed that program run time is rather long for the large-size practical case, which is due to the limitation of classical emulation and demands the forthcoming true quantum computation. Our results also revalidate the stability of the conventional classical genetic algorithm.