Mario Arbulu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mario Arbulu has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Balaguer
Universidad Carlos III de Madrid
17 shared publications D. Kaynov
Systems Engineering and Automation Department, Robotics Lab, Carlos III of Madrid University, Spain
6 shared publicationsL. Cabas
Systems Engineering and Automation Department, Robotics Lab, Carlos III of Madrid University, Spain
6 shared publicationsP. Staroverov
Robotics Lab, Department of Systems Engineering and Automation, University Carlos III of Madrid, Av. Universidad 30, Leganés, Madrid, Spain
4 shared publicationsDmitry Kaynov
Robotics Lab, Department of System Engineering and Automation, University Carlos III of Madrid, Av. Universidad 30, Leganés 28911 (MADRID), Spain
3 shared publications- Fernando Martínez Santa
Universidad Distrital Francisco José de Caldas
3 shared publications
Latest Publications
- Open Access
- 1 July 2022
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Tecnura
- Vol. 26 (73) , 130-141
Uso de robótica en una emergencia sanitaria
Contexto: La covid-19 ha acelerado la integración de la robótica y sistemas autónomos a los distintos sectores económicos, esto se ha presentado principalmente por la necesidad de mantener a las personas distanciadas para reducir el riesgo de contagio. En el mundo, han venido emergiendo y adaptándose diversos sistemas robóticos para ayudar a combatir la pandemia y reactivar nuevamente la economía. Método: Este trabajo presenta inicialmente las medidas que se han tomado en el mundo para luchar en contra de la pandemia, así como el impacto que ha dejado en la economía global. Posteriormente se seleccionan tres grupos de robots y se demarcan las principales tareas que estos han desarrollado durante dicho periodo. Discusión: Si bien la robótica se presenta como una herramienta en la lucha contra la pandemia y un motor para reactivar la economía, se deben tener en cuenta desafíos como el remplazo de humanos por robots en ciertas labores, mayor inequidad, falta de privacidad en espacios públicos e incremento de recursos para la investigación en robótica. Conclusiones: Se prevé un incremento en la demanda de robots para los próximos años, así como un decremento en la interacción entre humanos. El fin de la pandemia no hará retroceder la integración de los robots a los diversos sectores de la economía. La robótica es una tecnología disruptiva que hará cambiar al mundo en los próximos años. Método: Este trabajo presenta inicialmente las medidas que se han venido tomando alrededor del mundo para luchar en contra de la pandemia, así como el impacto que ha venido dejando en la economía mundial. Posteriormente se seleccionan tres grupos de robots y se demarcan las principales tareas que estos han desarrollado durante la pandemia. Discusión: Si bien la robótica se presenta como una herramienta en la lucha contra la pandemia y un motor para reactivar la economía, se deben tener en cuenta desafíos como tales como el remplazo de humanos por robots en ciertas labores, mayor inequidad, falta de privacidad en espacios públicos e incremento de recursos para la investigación en robótica. Conclusiones: Se prevé un incremento en la demanda de robots para los próximos años, así como se espera un decremento en la interacción entre humanos. El fin de la pandemia no hará retroceder la integración de los robots a los diversos sectores de la economía. La robótica es una tecnología disruptiva que hará cambiar al mundo en los próximos años.
- 1 July 2022
- Published by Universidad Distrital Francisco Jose de Caldas in Revista Tecnura
- Vol. 26 (73) , 130-141
Open AccessUso de robótica en una emergencia sanitaria
Contexto: La covid-19 ha acelerado la integración de la robótica y sistemas autónomos a los distintos sectores económicos, esto se ha presentado principalmente por la necesidad de mantener a las personas distanciadas para reducir el riesgo de contagio. En el mundo, han venido emergiendo y adaptándose diversos sistemas robóticos para ayudar a combatir la pandemia y reactivar nuevamente la economía. Método: Este trabajo presenta inicialmente las medidas que se han tomado en el mundo para luchar en contra de la pandemia, así como el impacto que ha dejado en la economía global. Posteriormente se seleccionan tres grupos de robots y se demarcan las principales tareas que estos han desarrollado durante dicho periodo. Discusión: Si bien la robótica se presenta como una herramienta en la lucha contra la pandemia y un motor para reactivar la economía, se deben tener en cuenta desafíos como el remplazo de humanos por robots en ciertas labores, mayor inequidad, falta de privacidad en espacios públicos e incremento de recursos para la investigación en robótica. Conclusiones: Se prevé un incremento en la demanda de robots para los próximos años, así como un decremento en la interacción entre humanos. El fin de la pandemia no hará retroceder la integración de los robots a los diversos sectores de la economía. La robótica es una tecnología disruptiva que hará cambiar al mundo en los próximos años. Método: Este trabajo presenta inicialmente las medidas que se han venido tomando alrededor del mundo para luchar en contra de la pandemia, así como el impacto que ha venido dejando en la economía mundial. Posteriormente se seleccionan tres grupos de robots y se demarcan las principales tareas que estos han desarrollado durante la pandemia. Discusión: Si bien la robótica se presenta como una herramienta en la lucha contra la pandemia y un motor para reactivar la economía, se deben tener en cuenta desafíos como tales como el remplazo de humanos por robots en ciertas labores, mayor inequidad, falta de privacidad en espacios públicos e incremento de recursos para la investigación en robótica. Conclusiones: Se prevé un incremento en la demanda de robots para los próximos años, así como se espera un decremento en la interacción entre humanos. El fin de la pandemia no hará retroceder la integración de los robots a los diversos sectores de la economía. La robótica es una tecnología disruptiva que hará cambiar al mundo en los próximos años.
- 11 August 2020
- Published by Springer Nature
- p. 165-174
Free-Obstacle Path Finding for Assistant Robot Based on Image Skeletonization
- 11 August 2020
- Published by Springer Nature
- p. 165-174
Free-Obstacle Path Finding for Assistant Robot Based on Image Skeletonization
- 18 December 2018
- Published by Springer Nature
- p. 205-214
Industry 4.0, Intelligent Visual Assisted Picking Approach
- 18 December 2018
- Published by Springer Nature
- p. 205-214
Industry 4.0, Intelligent Visual Assisted Picking Approach
- 16 June 2018
- Published by Springer Nature
- p. 304-313
An Algorithm Based on the Bacterial Swarm and Its Application in Autonomous Navigation Problems
- 16 June 2018
- Published by Springer Nature
- p. 304-313
An Algorithm Based on the Bacterial Swarm and Its Application in Autonomous Navigation Problems
- 10 June 2018
- Published by Springer Nature
- p. 596-603
A Data-Driven Path Planner for Small Autonomous Robots Using Deep Regression Models
- 10 June 2018
- Published by Springer Nature
- p. 596-603
A Data-Driven Path Planner for Small Autonomous Robots Using Deep Regression Models
- 27 July 2017
- Published by Springer Nature in Dysphagia
- Vol. 33 (1) , 15-25
Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients
Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC–ROC) and its relationship with the eight-point penetration–aspiration scale (PAS) using the Spearman’s ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC–ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.
- 27 July 2017
- Published by Springer Nature in Dysphagia
- Vol. 33 (1) , 15-25
Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients
Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC–ROC) and its relationship with the eight-point penetration–aspiration scale (PAS) using the Spearman’s ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC–ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of passive rectifier circuits for energy harvesting applications
Recent developments in the design of low-power circuits have allowed Energy Harvesting (EH) systems to feed electronic circuits that execute complex processes, permitting that such systems play an important role in different application areas (e.g. Wireless Sensor Networks (WSN), biomedical devices, Internet of things (IoT), among others). Due to the low power output presented by these systems (in the range of #x03BC;W to mW), the reduction of any potential losses presented in the circuits that form the EH system is a mayor issue; therefore, a careful selection of the circuits and its components may improve the performance. In this work, a comparison of various rectifier circuits found in the EH literature is presented. Based on the operation of each rectifier, the modeling of the power losses of each circuit will be introduced. Finally, the simulation results of the considered circuits are presented with the aim to measure parameters, like the efficiency, and perform a quantitative comparison.
- 3 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of passive rectifier circuits for energy harvesting applications
Recent developments in the design of low-power circuits have allowed Energy Harvesting (EH) systems to feed electronic circuits that execute complex processes, permitting that such systems play an important role in different application areas (e.g. Wireless Sensor Networks (WSN), biomedical devices, Internet of things (IoT), among others). Due to the low power output presented by these systems (in the range of #x03BC;W to mW), the reduction of any potential losses presented in the circuits that form the EH system is a mayor issue; therefore, a careful selection of the circuits and its components may improve the performance. In this work, a comparison of various rectifier circuits found in the EH literature is presented. Based on the operation of each rectifier, the modeling of the power losses of each circuit will be introduced. Finally, the simulation results of the considered circuits are presented with the aim to measure parameters, like the efficiency, and perform a quantitative comparison.
- Open Access
- 10 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-23
Design, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.
- 10 May 2016
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-23
Open AccessDesign, development and validation of a new laryngo-pharyngeal endoscopic esthesiometer and range-finder based on the assessment of air-pulse variability determinants
Laryngo-pharyngeal mechano-sensitivity (LPMS) is involved in dysphagia, sleep apnea, stroke, irritable larynx syndrome and cough hypersensitivity syndrome among other disorders. These conditions are associated with a wide range of airway reflex abnormalities. However, the current device for exploring LPMS is limited because it assesses only the laryngeal adductor reflex during fiber-optic endoscopic evaluations of swallowing and requires a high degree of expertise to obtain reliable results, introducing intrinsic expert variability and subjectivity. We designed, developed and validated a new air-pulse laryngo-pharyngeal endoscopic esthesiometer with a built-in laser range-finder (LPEER) based on the evaluation and control of air-pulse variability determinants and on intrinsic observer variability and subjectivity determinants of the distance, angle and site of stimulus impact. The LPEER was designed to be capable of delivering precise and accurate stimuli with a wide range of intensities that can explore most laryngo-pharyngeal reflexes. We initially explored the potential factors affecting the reliability of LPMS tests and included these factors in a multiple linear regression model. The following factors significantly affected the precision and accuracy of the test (P < 0.001): the tube conducting the air-pulses, the supply pressure of the system, the duration of the air-pulses, and the distance and angle between the end of the tube conducting the air-pulses and the site of impact. To control all of these factors, an LPEER consisting of an air-pulse generator and an endoscopic laser range-finder was designed and manufactured. We assessed the precision and accuracy of the LPEER’s stimulus and range-finder according to the coefficient of variation (CV) and by looking at the differences between the measured properties and the desired values, and we performed a pilot validation on ten human subjects. The air-pulses and range-finder exhibited good precision and accuracy (CV < 0.06), with differences between the desired and measured properties at <3 % and a range-finder measurement error of <1 mm. The tests in patients demonstrated obtainable and reproducible thresholds for the laryngeal adductor, cough and gag reflexes. The new LPEER was capable of delivering precise and accurate stimuli for exploring laryngo-pharyngeal reflexes.