Jian-Wei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jian-Wei Zhang has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
L. J. Wang
State Key Laboratory of Precision Space-time Information Sensing Technology, Department of Precision Instrument, Tsinghua University 1 , Beijing 100084
12 shared publications- Li-Jun Wang
Department of Precision Instrument, Tsinghua University, Beijing 100084, China
11 shared publications - Shi-Guang Wang
Department of Precision Instrument, Tsinghua University, Beijing 100084, China
11 shared publications Lijun Wang
Tsinghua University
7 shared publicationsN. C. Xin
7 shared publicationsJ. Z. Han
6 shared publications
Latest Publications
- 18 March 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (3)
Sympathetic-laser-cooling ion microwave frequency standard with accuracy and stability at 10 − 15 level
- 18 March 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (3)
Sympathetic-laser-cooling ion microwave frequency standard with accuracy and stability at 10 − 15 level
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (10)
Precision determination of an excited-state hyperfine splitting of cadmium ions
Precision determination of the hyperfine splitting (HFS) of cadmium ions is useful to study space-time variation of fundamental physical constants and isotope shifts. In this work, we present the precision frequency measurement of the excited-state 2P3/2 hyperfine splitting of 111,113Cd+ ions using the laser-induced fluorescence technique. By introducing the technology of sympathetic cooling and measuring the doublet line transition exploitation of an optical comb system, the uncertainties are improved to 16 and 12 kHz, respectively, two orders of magnitude higher precision than the reported results from the linear transformation of isotope shifts. The magnetic dipole constants AP3/2 of 111Cd+ and 113Cd+ are estimated to be 395 939(8) and 411 275(6) kHz, respectively. The difference between the measured and theoretical hyperfine structure constants indicates that more physical effects are required to be considered in the theoretical calculation and provides critical data for the examination of deviation from King-plot linearity in isotope shifts.
- 1 March 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (10)
Precision determination of an excited-state hyperfine splitting of cadmium ions
Precision determination of the hyperfine splitting (HFS) of cadmium ions is useful to study space-time variation of fundamental physical constants and isotope shifts. In this work, we present the precision frequency measurement of the excited-state 2P3/2 hyperfine splitting of 111,113Cd+ ions using the laser-induced fluorescence technique. By introducing the technology of sympathetic cooling and measuring the doublet line transition exploitation of an optical comb system, the uncertainties are improved to 16 and 12 kHz, respectively, two orders of magnitude higher precision than the reported results from the linear transformation of isotope shifts. The magnetic dipole constants AP3/2 of 111Cd+ and 113Cd+ are estimated to be 395 939(8) and 411 275(6) kHz, respectively. The difference between the measured and theoretical hyperfine structure constants indicates that more physical effects are required to be considered in the theoretical calculation and provides critical data for the examination of deviation from King-plot linearity in isotope shifts.
- Open Access
Precision determination of the excited-state hyperfine splitting of Cadmium ions
Precision determination of the hyperfine splitting of cadmium ions is essential to study space-time variation of fundamental physical constants and isotope shifts. In this work, we present the precision frequency measurement of the excited-state $^2{P}_{3/2}$ hyperfine splitting of $^{111,113}\mathrm{Cd}^+$ ions using the laser-induced fluorescence technique. By introducing the technology of sympathetic cooling and setting up free-space beat detection unit based on the optical comb, the uncertainties are improved to 14.8 kHz and 10.0 kHz, respectively, two orders of magnitude higher than the reported results from the linear transformation of isotope shifts. The magnetic dipole constants $A_{P_{3/2}}$ of $^{111}\mathrm{Cd}^+$ and $^{113}\mathrm{Cd}^+$ are estimated to be 395 938.8(7.4) kHz and 411 276.0(5.0) kHz, respectively. The difference between the measured and theoretical hyperfine structure constants indicates that more physical effects are required to be considered in the theoretical calculation, and provides critical data for the examination of deviation from King-plot linearity in isotope shifts.Open AccessPrecision determination of the excited-state hyperfine splitting of Cadmium ions
Precision determination of the hyperfine splitting of cadmium ions is essential to study space-time variation of fundamental physical constants and isotope shifts. In this work, we present the precision frequency measurement of the excited-state $^2{P}_{3/2}$ hyperfine splitting of $^{111,113}\mathrm{Cd}^+$ ions using the laser-induced fluorescence technique. By introducing the technology of sympathetic cooling and setting up free-space beat detection unit based on the optical comb, the uncertainties are improved to 14.8 kHz and 10.0 kHz, respectively, two orders of magnitude higher than the reported results from the linear transformation of isotope shifts. The magnetic dipole constants $A_{P_{3/2}}$ of $^{111}\mathrm{Cd}^+$ and $^{113}\mathrm{Cd}^+$ are estimated to be 395 938.8(7.4) kHz and 411 276.0(5.0) kHz, respectively. The difference between the measured and theoretical hyperfine structure constants indicates that more physical effects are required to be considered in the theoretical calculation, and provides critical data for the examination of deviation from King-plot linearity in isotope shifts. - 9 December 2023
- Published by Elsevier in Chinese Journal of Physics
- Vol. 88, 485-492
Absolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for ions cooling- 9 December 2023
- Published by Elsevier in Chinese Journal of Physics
- Vol. 88, 485-492
Absolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for ions cooling- 2 November 2023
- Published by Springer Nature
- p. 281-287
High-Performance Microwave Frequency Standard Systems Based on the Ground-State Hyperfine Splitting of 171Yb+ and 113Cd+ Ions
- 2 November 2023
- Published by Springer Nature
- p. 281-287
High-Performance Microwave Frequency Standard Systems Based on the Ground-State Hyperfine Splitting of 171Yb+ and 113Cd+ Ions
- 12 September 2023
- Published by Elsevier in Review of Palaeobotany and Palynology
- Vol. 318, 104986
Geographical and morphological changes of conifers in Yunnan, China during the Cenozoic in response to climatic changes
- 12 September 2023
- Published by Elsevier in Review of Palaeobotany and Palynology
- Vol. 318, 104986
Geographical and morphological changes of conifers in Yunnan, China during the Cenozoic in response to climatic changes
- Open Access
Absolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for Yb+ ions cooling
We investigate 13 hyperfine structures of transition lines of 127I2 near 554 nm, namely, the R(50) 22-0, P(46) 22-0, P(121) 24-0, P(69) 25-1, R(146) 25-0, R(147) 28-1, P(160) 26-0, P(102) 26-1, R(96) 23-0, R(49) 22-0, P(45) 22-0, P(92) 23-0, and R(72) 25-1 transitions, and measure their absolute frequencies with an optical frequency comb. A 369 nm frequency-tripled laser is frequency stabilized by locking the 554 nm harmonic-frequency laser to the R(146) 25-0 a15 line of 127I2 via modulation transfer spectroscopy. A frequency stability of 5E-12 is observed over a 1000 s integration time. The measurement of the molecular iodine spectroscopy at 554 nm enriches high-precision experimental data, and also enables theoretical predictions. Meanwhile, the 369 nm frequency-tripled laser stabilized by molecular iodine spectroscopy has wide applications in frequency metrology, and quantum information processing based on Yb+ ions.
Open AccessAbsolute frequency measurement of molecular iodine hyperfine transitions at 554 nm and its application to stabilize a 369 nm laser for Yb+ ions cooling
We investigate 13 hyperfine structures of transition lines of 127I2 near 554 nm, namely, the R(50) 22-0, P(46) 22-0, P(121) 24-0, P(69) 25-1, R(146) 25-0, R(147) 28-1, P(160) 26-0, P(102) 26-1, R(96) 23-0, R(49) 22-0, P(45) 22-0, P(92) 23-0, and R(72) 25-1 transitions, and measure their absolute frequencies with an optical frequency comb. A 369 nm frequency-tripled laser is frequency stabilized by locking the 554 nm harmonic-frequency laser to the R(146) 25-0 a15 line of 127I2 via modulation transfer spectroscopy. A frequency stability of 5E-12 is observed over a 1000 s integration time. The measurement of the molecular iodine spectroscopy at 554 nm enriches high-precision experimental data, and also enables theoretical predictions. Meanwhile, the 369 nm frequency-tripled laser stabilized by molecular iodine spectroscopy has wide applications in frequency metrology, and quantum information processing based on Yb+ ions.
- Open Access
Precise determination of ground-state hyperfine splitting and calculation of Zeeman coefficients for 171Yb+ microwave frequency standard
We report precise measurement of the hyperfine splitting and calculation of the Zeeman coefficients of the $^{171}$Yb$^+$ ground state. The absolute hyperfine splitting frequency is measured using high-resolution laser-microwave double-resonance spectroscopy at 0.1 mHz level, and evaluated using more accurate Zeeman coefficients. These Zeeman coefficients are derived using Landé $g_J$ factors calculated by two atomic-structure methods, multiconfiguration Dirac-Hartree-Fock, and multireference configuration interaction. The cross-check of the two calculations ensures an accuracy of the Zeeman coefficients at $10^{-2}$ Hz/G$^2$ level. The results provided in this paper improve the accuracy and reliability of the second-order Zeeman shift correction, thus further improving the accuracy of the microwave frequency standards based on $^{171}$Yb$^+$. The high-precision hyperfine splitting and Zeeman coefficients could also support could also support further experiments to improve the constraints of fundamental constants through clock frequency comparison of the Yb$^+$ system.Open AccessPrecise determination of ground-state hyperfine splitting and calculation of Zeeman coefficients for 171Yb+ microwave frequency standard
We report precise measurement of the hyperfine splitting and calculation of the Zeeman coefficients of the $^{171}$Yb$^+$ ground state. The absolute hyperfine splitting frequency is measured using high-resolution laser-microwave double-resonance spectroscopy at 0.1 mHz level, and evaluated using more accurate Zeeman coefficients. These Zeeman coefficients are derived using Landé $g_J$ factors calculated by two atomic-structure methods, multiconfiguration Dirac-Hartree-Fock, and multireference configuration interaction. The cross-check of the two calculations ensures an accuracy of the Zeeman coefficients at $10^{-2}$ Hz/G$^2$ level. The results provided in this paper improve the accuracy and reliability of the second-order Zeeman shift correction, thus further improving the accuracy of the microwave frequency standards based on $^{171}$Yb$^+$. The high-precision hyperfine splitting and Zeeman coefficients could also support could also support further experiments to improve the constraints of fundamental constants through clock frequency comparison of the Yb$^+$ system. - Open Access
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
174Yb+–113Cd+ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard
We reported the realization of a 174Yb+–113Cd+ bi-species Coulomb crystal comprising 174Yb+, a heavier ion, as coolant and verified the potential of applying a coolant ion with a greater mass than the clock ion to sympathetically cooled microwave frequency standard. The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The 113Cd+ ions are trapped in the center, which reduces considerably RF heating and excess micro-motion to which the 113Cd+ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to 5×10−16, which represents an order of magnitude improvement over sympathetic cooled 40Ca+–113Cd+ crystal. The second-order Zeeman frequency shift, which contributes the largest term of the systematic frequency shifts to the microwave ion frequency standard, is estimated to be as low as 7.133×10−13 corresponding to the low value of the operating magnetic field. The relevant AC Stark shift uncertainty is estimated to be 4×10−19. These results demonstrate that using a heavier coolant ion is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a 174Yb+–113Cd+ bicrystal.
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
Open Access174Yb+–113Cd+ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard
We reported the realization of a 174Yb+–113Cd+ bi-species Coulomb crystal comprising 174Yb+, a heavier ion, as coolant and verified the potential of applying a coolant ion with a greater mass than the clock ion to sympathetically cooled microwave frequency standard. The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The 113Cd+ ions are trapped in the center, which reduces considerably RF heating and excess micro-motion to which the 113Cd+ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to 5×10−16, which represents an order of magnitude improvement over sympathetic cooled 40Ca+–113Cd+ crystal. The second-order Zeeman frequency shift, which contributes the largest term of the systematic frequency shifts to the microwave ion frequency standard, is estimated to be as low as 7.133×10−13 corresponding to the low value of the operating magnetic field. The relevant AC Stark shift uncertainty is estimated to be 4×10−19. These results demonstrate that using a heavier coolant ion is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a 174Yb+–113Cd+ bicrystal.
- Open Access
$^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard
We reported the realization of a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ bi-species Coulomb crystal comprising $^{174}\mathrm{Yb}^+$ ions as coolant and verified its potential for application as a $^{113}\mathrm{Cd}^+$ microwave frequency standard employing sympathetic cooling.The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The $^{113}\mathrm{Cd}^+$ ions are trapped in the center, which reduces considerably RF heating and excess micromotion to which the $^{113}\mathrm{Cd}^+$ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to $5\times10^{-16}$, which represents an order of magnitude improvement over sympathetic cooled $^{40}\mathrm{Ca}^+$-$^{113}\mathrm{Cd}^+$ crystal. The uncertainty from the second-order Zeeman effect, which contributes the largest uncertainty to the microwave-ion frequency standard, is reduced to $4\times10^{-16}$. The relevant AC Stark shift uncertainty is estimated to be $4\times10^{-19}$. These results indicate using $^{174}\mathrm{Yb}^+$ as coolant ions for $^{113}\mathrm{Cd}^+$ is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ two-component crystal.Open Access$^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard
We reported the realization of a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ bi-species Coulomb crystal comprising $^{174}\mathrm{Yb}^+$ ions as coolant and verified its potential for application as a $^{113}\mathrm{Cd}^+$ microwave frequency standard employing sympathetic cooling.The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The $^{113}\mathrm{Cd}^+$ ions are trapped in the center, which reduces considerably RF heating and excess micromotion to which the $^{113}\mathrm{Cd}^+$ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to $5\times10^{-16}$, which represents an order of magnitude improvement over sympathetic cooled $^{40}\mathrm{Ca}^+$-$^{113}\mathrm{Cd}^+$ crystal. The uncertainty from the second-order Zeeman effect, which contributes the largest uncertainty to the microwave-ion frequency standard, is reduced to $4\times10^{-16}$. The relevant AC Stark shift uncertainty is estimated to be $4\times10^{-19}$. These results indicate using $^{174}\mathrm{Yb}^+$ as coolant ions for $^{113}\mathrm{Cd}^+$ is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a $^{174}\mathrm{Yb}^+$-$^{113}\mathrm{Cd}^+$ two-component crystal.