GKGo Kato

Go Kato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Go Kato has a total of 116 co-authors. Here are the top co-authors by number of shared publications:

  • Megumu Yoshimura

    Department of Integrative Physiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan; Research Division for Life Sciences, Kumamoto Health Science University, Kumamoto, Japan; Nogata Nakamura Hospital, Fukuoka, Japan

    6 shared publications
  • Hidemasa Furue

    5 shared publications
  • Masaharu Mizuno

    Department of Anesthesia and Critical Care, Beth Israel Deaconess Medical Center, Boston, Massachusetts

    5 shared publications
  • Toshiharu Yasaka

    Department of Immunology, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima, Japan

    5 shared publications
  • Andrew M. Strassman

    Department of Anesthesia and Critical Care, Beth Israel Deaconess Medical Center, Boston, Massachusetts

    4 shared publications
  • Masafumi Kosugi

    Department of Anesthesia and Critical Care, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA 02215, USA

    4 shared publications

Latest Publications

  • Open Access

    Ligamentum Flavum Hematoma Accompanied by Intraspinal and Extraspinal Hematomas: A Case Report

    by Toshiaki Sugita, Shinji Tomari, Daichi Kitahara, Yasumasa Ito, Go Kato

    Studies on ligamentum flavum hematoma (LFH) have been gradually increasing; however, no study has reported an LFH spreading to the intraspinal and extraspinal spaces. The purpose of this report is to discuss this rare condition and report that extraspinal hematoma can be formed by LFH. The authors present the case of a 78-year-old man presented with right L5 radiculopathy caused by a space-occupying lesion with intraspinal and extraspinal expansions at the L4-L5 vertebral levels demonstrated on MRI. We tentatively diagnosed these lesions as intraspinal and extraspinal hematomas originating from the ligamentum flavum based on the chronological changes seen on MRI and computed tomography-based needle biopsy. After the extirpation of these lesions, the symptoms were relieved. Three months later, the patient could walk without a cane. From the intraoperative findings and pathological examination, we concluded that the extraspinal hematoma in paravertebral muscle was caused by an LFH of unknown etiology. This case report describes the difficulty in diagnosing LFH accompanied by an extraspinal hematoma with wide-spreading expansion and highlights the usefulness of repetitive MRI over time in capturing chronological changes of the hematoma. As far as we know, this is the first study on an LFH accompanied by an extraspinal hematoma in the multifidus.


  • Open Access

    Perpendicular probing and screwing technique: A simple method for accurate pedicle screw placement based on the human internal reference frame for angle estimation

    by Go Kato, Satoshi Baba, Kenichi Kawaguchi, Takeshi Watanabe, Takao Mae, Shinji Tomari

    The pedicle screw (PS) is widely used for spinal fixation surgery. However, PS malpositioning can cause critical complications; thus, the accuracy of ascertaining PS trajectory is paramount. This study aimed to demonstrate the accuracy and safety of a simple and cost-effective PS placement technique using a human internal reference frame for angle estimation. Ex vivo lumbar porcine spine samples were fixed to a wooden board with rostrocaudal and mediolateral rotational angles adjusted by two angle vises. PS entry points (EPs) were identified using clear anatomical vertebral landmarks. PS placement was performed on one side using the perpendicular probing and screwing technique (PPST), wherein the attitude angle of the sample was adjusted such that the longitudinal axis of the target pedicle was perpendicular to the ground. The pedicle probe and PS driver were manually maintained perpendicular to the ground during probing and PS placement. PS placement on the contralateral side was performed freehand as a control. Offsets between the preoperatively planned and implanted PS rotational angles measured using computed tomography for PPST and freehand method were analyzed. Pedicle wall penetration was also evaluated. The mean ± standard error of the medial rotational offsets was 5.83° ± 0.57° in the freehand group versus 2.89° ± 0.31° in the PPST group (p vs 0.80 ± 0.17 mm in the freehand group, p = 0.0071). Thus, PPST improved PS positioning accuracy, resulting in reduced pedicle wall penetration and increased PS placement safety. This simple technique is also potentially cost-effective for institutions without computer-assisted surgical systems.


  • Open Access

    Use of an inertial measurement unit sensor in pedicle screw placement improves trajectory accuracy

    by Satoshi Baba, Kenichi Kawaguchi, Kazuhito Itamoto, Takeshi Watanabe, Mitsumasa Hayashida, Takao Mae, Yasuharu Nakashima, Go Kato

    Ascertaining the accuracy of the pedicle screw (PS) trajectories is important as PS malpositioning can cause critical complications. We aimed to determine the angle range over which estimation is unreliable; build a low-cost PS placement support system that uses an inertial measurement unit (IMU) to enable the monitoring of surgical tools and PS trajectories, and determine the situations where IMU support would be most beneficial. In PS insertion experiments, we used cadaver samples that included lumbar porcine spines. Computed tomography images obtained before and after PS insertion were viewed. Offsets between the planned and implanted PS trajectories in the freehand and IMU-assisted groups were analyzed. The PS cortical bone breaches were classified according to the Gertzbein and Robbins criteria (GRC). Added head-down tilted sample experiments were repeated wherein we expected a decreased rostro-caudal rotational accuracy of the PS according to the angle estimation ability results. Evaluation of the PS trajectory accuracy revealed no significant advantage of IMU-assisted rostro-caudal rotational accuracy versus freehand accuracy. According to the GRC, IMU assistance significantly increased the rate of clinically acceptable PS positions (RoCA) than the freehand technique. In the head-down tilted sample experiments, IMU assist provided increased accuracies with both rostro-caudal and medial rotational techniques when compared with the freehand technique. In the freehand group, RoCA was significantly decreased in samples with rostral tilting relative to that in the samples without. However, In the IMU-assisted group, no significant difference in RoCA between the samples with and without head-down tilting was observed. Even when the planned PS medial and/or rostro-caudal rotational angle was relatively large and difficult to reproduce manually, IMU-support helped maintain the PS trajectory accuracy and positioning safety. IMU assist in PS placement was more beneficial, especially for larger rostro-caudal and/or medial rotational pedicle angles.


  • Open Access

    Tiotropium/Olodaterol Improves Pulmonary Function and Physical Activity in Patients with Treatment-Naïve COPD

    by K. Takahashi, M. Uchida, G. Kato, A. Takamori, H. Sadamatsu, M. Tanaka, R. Tajiri, H. Inoue, T. Kinoshita, K. Kojima, et al.


  • Spatial organization of activity evoked by focal stimulation within the rat spinal dorsal horn as visualized by voltage-sensitive dye imaging in the slice

    by Masaharu Mizuno, Go Kato, Andrew M. Strassman

    In a prior study using laser scanning photostimulation, we found a pronounced cell type-specific mediolateral asymmetry in the local synaptic connectivity in the superficial laminae of the spinal dorsal horn (Kosugi M, Kato G, Lukashov S, Pendse G, Puskar Z, Kozsurek M, Strassman AM. J Physiol 591: 1935–1949, 2013). To obtain information on dorsal horn organization that might complement findings from microelectrode studies, voltage-sensitive dye imaging was used in the present study to examine patterns of activity evoked by focal electrical stimulation, in the presence and absence of synaptic blocking agents, at different positions in transverse, parasagittal, and horizontal slices of the dorsal horn of 2- to 3-wk -old male rats. A pronounced difference in responsiveness was found between medial and lateral dorsal horn, in that medial sites in the superficial dorsal horn showed much larger synaptic responses to focal stimulation than lateral sites. This difference appeared to be a result of a difference in the intrinsic elements of the dorsal horn, rather than a difference in the inputs from the white matter, because the stimulus intensities were subthreshold for evoking synaptic responses from stimulation at sites in the white matter, although it is also possible that the greater responsiveness is due, at least in part, to activation of Aβ primary afferent fibers that pass through the medial dorsal horn. The results raise the possibility of differences between medial and dorsal horn that need to be taken into account in the interpretation of studies of dorsal horn organization.NEW & NOTEWORTHY We used voltage-sensitive dye imaging to obtain information on spatial aspects of dorsal horn organization that are difficult to examine with single-cell approaches because of the limitations of microelectrode sampling. The most noteworthy finding was a previously unreported, extreme difference between medial and lateral dorsal horn in responsiveness to focal stimulation that appears to result, at least in part, from a greater degree of excitability or local connectivity in medial dorsal horn.


  • Open Access

    Effect of cartilaginous endplates on extruded disc resorption in lumbar disc herniation

    by Kenichi Kawaguchi, Katsumi Harimaya, Yoshihiro Matsumoto, Mitsumasa Hayashida, Seiji Okada, Keiichiro Iida, Go Kato, Kuniyoshi Tsuchiya, Toshio Doi, Yoshinao Oda, et al.

    The aim of this study was to investigate the clinicopathologic features of lumbar disc herniation (LDH) with endplate degeneration and the association between cartilaginous fragments and inflammatory response to the herniated disc. LDH often involves hyaline cartilage fragments pulled from the vertebral endplates. Modic changes are closely associated with LDH that contains hyaline cartilage, and cartilaginous endplates seem to affect resorption of the herniated disc. A total of 78 patients who underwent microscopic discectomy between 9 and 16 weeks after an occurrence of LDH were reviewed. Modic changes, disc degeneration, high-intensity zone, and vertebral corner defect were evaluated using magnetic resonance imaging (MRI). Histopathological observations of cartilaginous endplates and inflamed granulation tissue in the herniated disc were made. In cases with inflamed granulation tissue, neovascularization and macrophage infiltration were also evaluated using immunohistochemical analysis. Modic changes were observed in approximately one-third of the patients (26 cases: type 1, 7; type 2, 17; and type 3, 2). Cartilaginous endplates were observed in 32 cases (41%) and in the majority of cases with Modic changes compared with cases without Modic changes (65%, p = 0.001). Although inflamed granulation tissue was observed in 60 cases (77%), no significant differences were detected in patient age and the composition of the herniated material. Immunohistochemical analysis showed that fewer CD34-positive capillaries and CD68-positive cells were found in cases with cartilaginous fragments compared with those without cartilaginous fragments (p < 0.001). In addition, a higher immunoreactivity to CD34 and CD68 was found in herniated discs p < 0.001). There is an association between LDH with endplate degeneration and cartilaginous herniation, with Modic type 2 predominating. Furthermore, neovascularization and macrophage infiltration, especially if the amount of cartilage is high, are likely to be less frequent in cartilaginous herniation, leading to failure in the spontaneous remission of clinical symptoms.


  • Open Access

    Double non-contiguous fractures in a patient with spondylo-epiphyseal dysplasia with spinal ankylosis treated with open and percutaneous spinal fixation technique: a case report

    by Takahiro Ushijima, Kenichi Kawaguchi, Tadashi Matsumoto, Masaki Takagi, Tatsuro Kondoh, Gen Nishimura, Aritoshi Iida, Shiro Ikegawa, Nobuhiko Haga, Go Kato

    Patients with ankylosing spines are susceptible to developing spinal fractures even with minor trauma and can develop early or late neurological injuries. These fractures require early and aggressive surgical management to enable spinal stability and/or neural decompression. Being highly unstable by nature, they require relatively long segment instrumentation and fusion, which can increase paravertebral soft tissue damage and perioperative bleeding. The purpose of this report is to describe a rare case of traumatic double fractures at the cervico-thoracic and thoraco-lumbar transition zones in ankylosing spine with spondylo-epiphyseal dysplasia (SED) of unknown cause, which were successfully treated with a combined open and percutaneous spinal fusion procedure. A 46-year-old woman who was diagnosed with non-contiguous fractures in cervico-thoracic and thoraco-lumbar junction zones among multiple injuries sustained in a traffic accident was treated with hybrid techniques for posterior instrumentation with an open approach using a computed tomography (CT)-based navigation system and percutaneous pedicle-screwing method. She regained mobility to pre-admission levels and started walking on crutches 3 months postoperatively. Genetic testing for the cause of SED revealed no mutation in the COL2A1 or TRPVR4 genes. The union of fractured spine was confirmed on CT scan 1 year postoperatively. This is the first report of double spinal fractures in an ankylosing spine with genetically undetermined spondyloepiphyseal dysplasia. A long-segment posterior instrumentation procedure incorporating the invasive treatment of spinal fractures in ankylosing spondylitis or diffuse idiopathic hyperostosis was effective.


  • Open Access

    Microglial Contact Prevents Excess Depolarization and Rescues Neurons from Excitotoxicity

    by Go Kato, Hiroyuki Inada, Hiroaki Wake, Ryohei Akiyoshi, Akiko Miyamoto, Kei Eto, Tatsuya Ishikawa, Andrew J. Moorhouse, Andrew M. Strassman, Junichi Nabekura

    Microglia survey and directly contact neurons in both healthy and damaged brain, but the mechanisms and functional consequences of these contacts are not yet fully elucidated. Combining two-photon imaging and patch clamping, we have developed an acute experimental model for studying the role of microglia in CNS excitotoxicity induced by neuronal hyperactivity. Our model allows us to simultaneously examine the effects of repetitive supramaximal stimulation on axonal morphology, neuronal membrane potential, and microglial migration, using cortical brain slices from Iba-1 eGFP mice. We demonstrate that microglia exert an acute and highly localized neuroprotective action under conditions of neuronal hyperactivity. Evoking repetitive action potentials in individual layer 2/3 pyramidal neurons elicited swelling of axons, but not dendrites, which was accompanied by a large, sustained depolarization of soma membrane potential. Microglial processes migrated to these swollen axons in a mechanism involving both ATP and glutamate release via volume-activated anion channels. This migration was followed by intensive microglial wrapping of affected axons and, in some cases, the removal of axonal debris that induced a rapid soma membrane repolarization back to resting potentials. When the microglial migration was pharmacologically blocked, the activity-induced depolarization continued until cell death ensued, demonstrating that the microglia–axon contact served to prevent pathological depolarization of the soma and maintain neuronal viability. This is a novel aspect of microglia surveillance: detecting, wrapping, and rescuing neuronal soma from damage due to excessive activity.


  • Recurrent dislocations of the atlantooccipital and atlantoaxial joints in a halo vest fixator are resolved by backrest elevation in an elevation angle–dependent manner

    by Go Kato, Kenichi Kawaguchi, Nobuaki Tsukamoto, Keisuke Komiyama, Kazutaka Mizuta, Takayuki Onohara, Hirofumi Okano, Shunsuke Hotokezaka, Takao Mae