Navjot Kaur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Navjot Kaur has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Bhushan J. Toley
Indian Institute of Science Bangalore
6 shared publications Abhishek Dureja
1 shared publicationAndrea Dsouza
Department of Chemical Engineering, Indian Institute of Science Bangalore, Bangalore, 560012, India
1 shared publicationBrainerd Prince
1 shared publicationChand S. Navaneeth
Department of Biosystems Engineering, Plaksha University, Mohali, India
1 shared publicationDebayan Das
Department of Chemical Engineering, Indian Institute of Science Bangalore, Bangalore, 560012, India
1 shared publication
Latest Publications
- 12 February 2026
- Published by Elsevier in Food and Humanity
- Vol. 6
Willingness to buy gene edited food in developing countries: Findings from India
- 12 February 2026
- Published by Elsevier in Food and Humanity
- Vol. 6
Willingness to buy gene edited food in developing countries: Findings from India
- 27 November 2024
- Published by Springer Nature in Journal of Crop Science and Biotechnology
- Vol. 28 (2) , 155-165
Assessing risks associated with large-scale adoption of CRISPR gene-edited crops
- 27 November 2024
- Published by Springer Nature in Journal of Crop Science and Biotechnology
- Vol. 28 (2) , 155-165
Assessing risks associated with large-scale adoption of CRISPR gene-edited crops
- Open Access
- 24 June 2020
- Published by American Chemical Society (ACS) in ChemRxiv
A Stoichiometric and Pseudo Kinetic Model of Loop Mediated Isothermal Amplification
Loop mediated isothermal amplification (LAMP) is one of the most popular isothermal DNA amplification techniques for research and commercial applications. The LAMP mechanism is powered by strategic primer design and a strand displacement polymerase, generating products that fold over, creating loops. LAMP leads to generation of products of increasing length over time. These products containing multiple loops are conventionally called cauliflower structures. Existing literature on LAMP provides extremely limited understanding of progression of cascades of reactions involved in the reaction and it is believed that cauliflower structures of increasing length constitute a majority of the product formed in LAMP. This study presents a first of its kind stoichiometric and pseudo kinetic model to comprehend LAMP reactions in deeper depth by (i) classifying LAMP reaction products into uniquely identifiable categories, (ii) generating a condensed reaction network to depict millions of interconnected reactions occurring during LAMP, and (iii) elucidating the pathways for amplicon generation. Despite the inherent limitations of conventional stoichiometric modelling for polymerization type reactions (the network rapidly becomes too large and intractable), our model provides new theoretical understanding of the LAMP reaction pathway. The model shows that while longer length products are formed, it is the smaller length recycle amplicons that contribute more towards the exponential increase in the amount of double stranded DNA. Prediction of concentration of different types of LAMP amplicons will also contribute substantially towards informing design of probe-based assays.
- 24 June 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA Stoichiometric and Pseudo Kinetic Model of Loop Mediated Isothermal Amplification
Loop mediated isothermal amplification (LAMP) is one of the most popular isothermal DNA amplification techniques for research and commercial applications. The LAMP mechanism is powered by strategic primer design and a strand displacement polymerase, generating products that fold over, creating loops. LAMP leads to generation of products of increasing length over time. These products containing multiple loops are conventionally called cauliflower structures. Existing literature on LAMP provides extremely limited understanding of progression of cascades of reactions involved in the reaction and it is believed that cauliflower structures of increasing length constitute a majority of the product formed in LAMP. This study presents a first of its kind stoichiometric and pseudo kinetic model to comprehend LAMP reactions in deeper depth by (i) classifying LAMP reaction products into uniquely identifiable categories, (ii) generating a condensed reaction network to depict millions of interconnected reactions occurring during LAMP, and (iii) elucidating the pathways for amplicon generation. Despite the inherent limitations of conventional stoichiometric modelling for polymerization type reactions (the network rapidly becomes too large and intractable), our model provides new theoretical understanding of the LAMP reaction pathway. The model shows that while longer length products are formed, it is the smaller length recycle amplicons that contribute more towards the exponential increase in the amount of double stranded DNA. Prediction of concentration of different types of LAMP amplicons will also contribute substantially towards informing design of probe-based assays.
- Open Access
- 1 January 2020
- Published by American Association for the Advancement of Science (AAAS) in Computational and Structural Biotechnology Journal
- Vol. 18, 2336-2346
A stoichiometric and pseudo kinetic model of loop mediated isothermal amplification
• First of its kind model to comprehend the LAMP reaction network. • Classification of LAMP reaction products into uniquely identifiable categories. • Condensed reaction network to depict millions of interconnected reactions. • Estimation of concentrations of different types of amplicons generated in LAMP.
- 1 January 2020
- Published by American Association for the Advancement of Science (AAAS) in Computational and Structural Biotechnology Journal
- Vol. 18, 2336-2346
Open AccessA stoichiometric and pseudo kinetic model of loop mediated isothermal amplification
• First of its kind model to comprehend the LAMP reaction network. • Classification of LAMP reaction products into uniquely identifiable categories. • Condensed reaction network to depict millions of interconnected reactions. • Estimation of concentrations of different types of amplicons generated in LAMP.
- Open Access
- 31 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Paper Stacks for Uniform Rehydration of Dried Reagents in Paper Microfluidic Devices
Spatially uniform reconstitution of dried reagents is critical to the function of paper microfluidic devices. Advancing fluid fronts in paper microfluidic devices drive (convect) and concentrate rehydrated reagents to the edges, causing steep chemical gradients and imperfect mixing. This largely unsolved problem in paper microfluidics is exacerbated by increasing device dimensions. In this article, we demonstrate that mixing of dried reagents with a rehydrating fluid in paper microfluidics may be significantly enhanced by stacking paper layers having different wicking rates. Compared to single-layer paper membranes, stacking reduced the “non-reactive area”, i.e. area in which the reconstituted reagents did not interact with the rehydrating fluid, by as much as 97% in large (8 cm × 2 cm) paper membranes. A paper stack was designed to collect ~0.9 ml liquid sample and uniformly mix it with dried reagents. Applications of this technology are demonstrated in two areas: (i) collection and dry storage of sputum samples for tuberculosis testing, and (ii) salivary glucose detection using an enzymatic assay and colorimetric readout. Maximizing the interaction of liquids with dried reagents is central to enhancing the performance of all paper microfluidic devices; this technique is therefore likely to find important applications in paper microfluidics.
- 31 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessPaper Stacks for Uniform Rehydration of Dried Reagents in Paper Microfluidic Devices
Spatially uniform reconstitution of dried reagents is critical to the function of paper microfluidic devices. Advancing fluid fronts in paper microfluidic devices drive (convect) and concentrate rehydrated reagents to the edges, causing steep chemical gradients and imperfect mixing. This largely unsolved problem in paper microfluidics is exacerbated by increasing device dimensions. In this article, we demonstrate that mixing of dried reagents with a rehydrating fluid in paper microfluidics may be significantly enhanced by stacking paper layers having different wicking rates. Compared to single-layer paper membranes, stacking reduced the “non-reactive area”, i.e. area in which the reconstituted reagents did not interact with the rehydrating fluid, by as much as 97% in large (8 cm × 2 cm) paper membranes. A paper stack was designed to collect ~0.9 ml liquid sample and uniformly mix it with dried reagents. Applications of this technology are demonstrated in two areas: (i) collection and dry storage of sputum samples for tuberculosis testing, and (ii) salivary glucose detection using an enzymatic assay and colorimetric readout. Maximizing the interaction of liquids with dried reagents is central to enhancing the performance of all paper microfluidic devices; this technique is therefore likely to find important applications in paper microfluidics.
- Open Access
- 25 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
A modular paper-and-plastic device for tuberculosis nucleic acid amplification testing in limited-resource settings
We present a prototype for conducting rapid, inexpensive and point-of-care-compatible nucleic acid amplification tests (NAATs) for tuberculosis (TB). The fluorescent isothermal paper-and-plastic NAAT (FLIPP-NAAT) uses paper-based loop mediated isothermal amplification (LAMP) for DNA detection. The cost of materials required to build a 12-test-zone device is $0.88 and the cost of reagents per reaction is $0.43. An inexpensive imaging platform enables filter-free fluorescence detection of amplified DNA using a cell-phone camera. FLIPP-NAAT can be operated by an untrained user and only requires a regular laboratory incubator as ancillary equipment. All reagents can be dry-stored in the device, facilitating storage and transportation without cold chains. The device design is modular and the assay demonstrated high specificity to Mycobacterium tuberculosis (Mtb), analytical sensitivity of the order of 10 copies of Mtb gDNA, and tolerance to complex samples. The clinical sensitivity and specificity of sputum-based FLIPP NAAT tests were 100% (zero false negatives) and 68.75% (five false positives), respectively (N = 30), using Xpert MTB/RIF assay as the reference standard. FLIPP-NAAT has the potential to provide affordable and accessible molecular diagnostics for TB in low- and middle-income countries, when used in conjunction with an appropriate sample preparation technique. Although demonstrated for the detection of TB, FLIPP-NAAT is a platform technology for amplification of any nucleic acid sequence.
- 25 October 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-12
Open AccessA modular paper-and-plastic device for tuberculosis nucleic acid amplification testing in limited-resource settings
We present a prototype for conducting rapid, inexpensive and point-of-care-compatible nucleic acid amplification tests (NAATs) for tuberculosis (TB). The fluorescent isothermal paper-and-plastic NAAT (FLIPP-NAAT) uses paper-based loop mediated isothermal amplification (LAMP) for DNA detection. The cost of materials required to build a 12-test-zone device is $0.88 and the cost of reagents per reaction is $0.43. An inexpensive imaging platform enables filter-free fluorescence detection of amplified DNA using a cell-phone camera. FLIPP-NAAT can be operated by an untrained user and only requires a regular laboratory incubator as ancillary equipment. All reagents can be dry-stored in the device, facilitating storage and transportation without cold chains. The device design is modular and the assay demonstrated high specificity to Mycobacterium tuberculosis (Mtb), analytical sensitivity of the order of 10 copies of Mtb gDNA, and tolerance to complex samples. The clinical sensitivity and specificity of sputum-based FLIPP NAAT tests were 100% (zero false negatives) and 68.75% (five false positives), respectively (N = 30), using Xpert MTB/RIF assay as the reference standard. FLIPP-NAAT has the potential to provide affordable and accessible molecular diagnostics for TB in low- and middle-income countries, when used in conjunction with an appropriate sample preparation technique. Although demonstrated for the detection of TB, FLIPP-NAAT is a platform technology for amplification of any nucleic acid sequence.
- 30 May 2018
- Published by Springer Nature in Journal of the Indian Institute of Science
- Vol. 98 (2) , 103-136
Multidimensional Paper Networks: A New Generation of Low-Cost Pump-Free Microfluidic Devices
- 30 May 2018
- Published by Springer Nature in Journal of the Indian Institute of Science
- Vol. 98 (2) , 103-136
Multidimensional Paper Networks: A New Generation of Low-Cost Pump-Free Microfluidic Devices
- 1 January 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (10) , 2213-2234
Paper-based nucleic acid amplification tests for point-of-care diagnostics
A critical review of paper-based nucleic acid amplification tests with a focus on integration and sequence of operations.
- 1 January 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (10) , 2213-2234
Paper-based nucleic acid amplification tests for point-of-care diagnostics
A critical review of paper-based nucleic acid amplification tests with a focus on integration and sequence of operations.