QLQingsong Li

Qingsong Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qingsong Li has a total of 140 co-authors. Here are the top co-authors by number of shared publications:

  • Zhiyuan Liu

    Research Center for Neural Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China

    10 shared publications
  • Guanglin Li

    Research Center for Neural Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China

    8 shared publications
  • Ke-Qin Zhang

    National Engineering Laboratory for Modern Silk, College of Textile and Clothing Engineering, Soochow University, Suzhou

    8 shared publications
  • Qiong Tian

    Shenzhen University of Advanced Technology, Shenzhen, China

    6 shared publications
  • Wei Yuan

    Printable Electronics Research Centre, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China

    5 shared publications
  • Chen Ding

    Printable Electronics Research Centre, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China

    4 shared publications

Latest Publications

  • Advances in printable flexible and stretchable thin-film electrodes: materials, interfaces, technologies and bioelectronic applications

    by Bowen Gu, Hang Zhao, Fei Long, Qingsong Li, Yang Zhao, Mei Yu, Xinyue Hu, Guanglin Li, Fei Han, Qiong Tian, et al.

    Printable flexible and stretchable thin-film electrodes combine advanced materials, additive manufacturing, and interface engineering to create soft, conductive, conformal bioelectronic interfaces for wearable, implantable, and ex vivo use.


  • Open Access

    Strain and Electromyography Dual-Mode Stretchable Sensor for Real-Time Monitoring of Joint Movement

    by Hanfei Li, Xiaomeng Zhou, Shouwei Yue, Qiong Tian, Qingsong Li, Jianhong Gong, Yong Yang, Fei Han, Hui Wei, Zhiyuan Liu, et al.

    Flexible sensors have emerged as critical interfaces for information exchange between soft biological tissues and machines. Here, we present a dual-mode stretchable sensor system capable of synchronous strain and electromyography (EMG) signal detection, integrated with wireless WIFI transmission for real-time joint movement monitoring. The system consists of two key components: (1) A multi-channel gel electrode array for high-fidelity EMG signal acquisition from target muscle groups, and (2) a novel capacitive strain sensor made of stretchable micro-cracked gold film based on Styrene Ethylene Butylene Styrene (SEBS) that exhibits exceptional performance, including >80% stretchability, >4000-cycle durability, and fast response time (<100 ms). The strain sensor demonstrates position-independent measurement accuracy, enabling robust joint angle detection regardless of placement variations. Through synchronized mechanical deformation and electrophysiological monitoring, this platform provides comprehensive movement quantification, with data visualization interfaces compatible with mobile and desktop applications. The proposed technology establishes a generalizable framework for multimodal biosensing in human motion analysis, robotics, and human–machine interaction systems.


  • Open Access

    A new paradigm for brain-machine interface electrodes: From static to dynamic, advancing toward embodied intelligence

    by Fei Han, Qianhengyuan Yu, Hairong Zheng, Guanglin Li, Qingsong Li, Qiong Tian, Yuan Zhang, Zhiyuan Liu

  • Autonomous 3D Self-Sensing Hybrid Membrane Actuator for Interactive Communicating

    by Yuanyuan Hou, Jiaxin Huang, Hao Ma, Qingsong Li, Zerong Xiang, Jiasheng Qian, Guanglin Li, Yanlong Tai, Ru Xia, Shanshan Zhu

    The advancement of intelligent soft actuators is progressively emphasizing the incorporation of environmental sensing capability to actuation, thereby enhancing the adaptability and interactivity of artificial systems. In the current situation where the sensing and actuation functions of soft actuators are generally separated, this work proposes an autonomous three-dimensional (3D) noncontact sensory actuator (NSA), based on the coupling of ″dielectric polarization-electrothermal conversion-thermal actuation″ triple effects. Specifically, the NSA hybrid membrane is composed of multiple interpenetrating networks, including a boron nitride nanosheet (BNNS) dielectric network for electrostatic field sensing and polarization, a silver nanowires (AgNWs) percolation network for dielectric enhancement and electrothermal conversion, and thermally contracted shape memory fiber (SMF) and thermally expanded polydimethylsiloxane (PDMS) networks for directional actuation. Based on the principle of electrostatic field and dielectric polarization, the SMF/BNNS composite (SMF-BN) fibrous membrane can logically sense the noncontact 3D motion, static/dynamic state of external objects, and distinguish material categories. Subsequently, the output sensing potential facilitates the built-in AgNWs nanonetwork heater to trigger electrothermal actuation of NSA. Lastly, as a biomimetic tongue, the autonomous noncontact "sensing-decision-actuating" of NSA is verified by seamless energy conversion in the process of sensing "prey" approaching and capturing. The proposed sensory actuator would facilitate multimodal integration for future wearable and human-machine-environment interaction technologies.


  • Flexible fibrous electrodes for implantable biosensing

    by Hanfei Li, Chenyang Li, Hang Zhao, Qingsong Li, Yang Zhao, Jianhong Gong, Guanglin Li, Huan Yu, Qiong Tian, Zhiyuan Liu, et al.

    Flexible fibrous electrodes have emerged as a promising technology for implantable biosensing applications, offering significant advancements in the monitoring and manipulation of biological signals. This review systematically explores the key aspects of flexible fibrous electrodes, including the materials, structural designs, and fabrication methods. A detailed discussion of electrode performance metrics is provided, covering factors such as conductivity, stretchability, axial channel count, and implantation duration. The diverse applications of these electrodes in electrophysiological signal monitoring, electrochemical sensing, tissue strain monitoring, and in vivo electrical stimulation are reviewed, highlighting their potential in biomedical settings. Finally, the review discusses the eight major challenges currently faced by implantable fibrous electrodes and explores future development directions, providing critical technical analysis and potential solutions for the advancement of next-generation flexible implantable fiber-based biosensors.


  • Open Access

    NeuroWorm: A movable long-term implantable soft fiber electrode for dynamic bioelectronics

    by Fei Han, Qianhengyuan Yu, Qingsong Li, Qiong Tian, Hairong Zheng, Yuan Zhang, Guanglin Li, Zhiyuan Liu

  • Open Access

    Bubble-blowing-inspired sub-micron thick freestanding silk films for programmable electronics

    by Qingsong Li, Fengjiao Bai, Jing Sun, Xiaomeng Zhou, Wei Yuan, Jin Lin, Ke-Qin Zhang, Guanglin Li, Zhiyuan Liu

    Thin film electronics that are capable of deforming and interfacing with nonplanar surfaces have attracted widespread interest in wearable motion detection or physiological signal recording due to their light weight, low stiffness, and high conformality. However, it is still a challenge to fabricate freestanding thin film substrates or matrices with only sub-micron thickness in a simple way, especially for those materials with metastable conformations, like regenerated silk protein. Herein, we developed a dip-coating method for the fabrication of sub-micron thick freestanding silk films inspired by blowing soap bubbles. Using a closed-loop frame to dip-coat in a concentrated silk fibroin aqueous solution, the substrate-free silk films with a thickness as low as hundreds of nanometres (∼150 nm) can be easily obtained after solvent evaporation. The silk films have extremely smooth surfaces (Rq < 3 nm) and can be tailored with different geometric shapes. The naturally dried silk films possess random coil dominated uncrystallized secondary structures, exhibiting high modulation ability and adaptability, which can be conformally attached on wrinkled skin or wrapped on human hair. Considering the methodological advantages and the unique properties of the obtained sub-micron thick silk films, several thin film based programmable electronics including transient/durable circuits, skin electrodes, transferred skin light-emitting devices and injectable electronics are successfully demonstrated after being deposited with gold or conducting polymer layers. This research provides a new avenue for preparing freestanding thin polymer films, showing great promise for developing thin film electronics in wearable and biomedical applications.


  • Ultrapermeable and Wet-Adhesive Monolayer Porous Film for Stretchable Epidermal Electrode

    by Qiong Tian, Hang Zhao, Rui Zhou, Tengfei Li, Jianping Huang, Wei Tong, Ruijie Xie, Qingsong Li, Guanglin Li, Zhiyuan Liu

    Noninvasive electrophysiological signal monitoring is significant for health care and scientific research. The simultaneous achievement of wet adhesion, stretchability, breathability, and low contact impedance is highly recommended in the epidermal electrode but still challenging. In this work, a monolayer porous film electrode with a pore size and wall thickness of less than ∼10 μm is fabricated via the breath figure method (BFM) and metal sputtering, and it was subsequently applied using epidermal electrophysiological monitoring. The ultrahigh permeability is comparable to the naked skin because the through holes of the monolayer porous film match well with the pores on human skin. The stretchability of 50% is realized with the combination of Au microcrack and the monolayer porous structure. The wet adhesion of 0.17 N/cm is established on the chemical bonding between the electrode and the epidermis. The contact impedance is comparable with the gold standard Ag/AgCl gel electrode, especially after sweating. Stable and precise electrophysiological signals are measured. Especially, the perspiration resistance of the monolayer porous film outperforms that of the gel electrode. The monolayer porous structure provides a new avenue to improve the breathability of the epidermal electronics.