  • Open Access

    Durable Fuel Cell Cathode Enabled by Pt Embedded Nanoscale Carbon Network via a Scalable Process

    by Suriya Venkatesan, Jens Mitzel, Tobias Morawietz, Emmanuelle Boehm‐Courjault, Deven P. Estes, Laure Guétaz, Indro Biswas, Jan Van Herle, Karsten Wegner, Pawel Gazdzicki, et al.

    Proton exchange membrane fuel cells (PEMFC) suffer significant voltage degradation at lower Pt loadings on the cathode. Expedited commercialization and sustainable utilization of scarce resources demand highly durable Pt‐based electrocatalysts produced via rapid, scalable processes. We present Pt nanoparticles (≈ 2 nm) embedded in a nanoscale carbon network, produced via controlled‐atmosphere flame spray pyrolysis, where native Pt nuclei serve as structural guides for the nanoscale overlayer. The gas‐phase‐derived porous catalyst exhibits high accessibility to Pt and uncompromised oxygen reduction activity upon activation and demonstrates at least fourfold lower performance loss at high current densities and fivefold lower electrochemical active surface area loss compared to state‐of‐the‐art alternatives in low‐Pt‐content fuel cells. The strong interfacial coordination between Pt and its surface‐grown carbon network, combined with the continuous, favorable structural evolution of the catalyst and catalyst layer, remarkably suppresses Pt degradation mechanisms, including ionomer poisoning and Pt dissolution, facilitates H + and O 2 transport to the catalyst, and ensures sustained performance under harsh fuel cell operating conditions.

  • Open Access

    Degradation of polymer-electrolyte membrane fuel cells tested at 80 and 95 °C using stack hardware

    by Álvaro García-Corral, Daniel Garcia-Sanchez, Robin Theiss, Tobias Morawietz, Rami Al-Khamiss, Juan Sanchez-Monreal, Jens Mitzel, Kaspar Andreas Friedrich, Pawel Gazdzicki

    To overcome heat rejection limitations, especially in transport applications, polymer-electrolyte-membrane fuel cells (PEMFCs) are required to operate at elevated temperature >80 °C. However, higher temperatures accelerate degradation of stack components. To evaluate the impact of operation temperature on durability of PEMFCs, state-of-the-art membrane-electrode-assemblies (MEAs) were investigated in single-cell configuration using stack hardware; the tests consist of 500 h operation at 80 and 95 °C including electrochemical diagnostics along with monitoring of local current-density and temperature distributions. Results showed that irreversible performance and ECSA losses are respectively 27% and 7% higher at 95 °C than at 80 °C. Reversible performance losses and the corresponding recovery of these losses are 13% and 8-11% lower at 95 °C. Current-density and temperature distributions are less homogeneous at 95 °C, and areas sustaining larger local currents and temperatures correlate with local catalyst-layer thinning. Ex-situ analyses reveal contamination of MEA by silicone due to degradation of gasket material at 95°C which deteriorates the water-management capabilities of the cell.

  • Open Access

    Application relevant load cycles for PEMFC component development and hybrid system optimization

    by Juan Sanchez-Monreal, Jens Mitzel, Christophe Vacquier, Pawel Gazdzicki


  • Nanomaterials and films for polymer electrolyte membrane fuel cells and solid oxide cells by flame spray pyrolysis

    by Suriya Venkatesan, Jens Mitzel, Karsten Wegner, Remi Costa, Pawel Gazdzicki, Kaspar Andreas Friedrich


  • (Invited) Mitigating PEMFC Durability Limitations

    by Jens Mitzel, Juan Sánchez-Monreal, Qian Zhang, Krishan Talukdar, Pia Aßmann, Li Wang, Mengmeng Sun, Qiang Fu, Xinhe Bao, Pawel Gazdzicki, et al.

    A key requirement for PEM fuel cells for transport applications is longevity with a targeted lifetime of 5,000-6,000 h for light duty electric vehicles (LDV) and 25,000-30,000 h for heavy duty vehicles (HDV) [1]. In parallel, other KPIs such as high power density at certain voltage level (2024 target: 1.8 A cm-2 at 660 mV for LDV) and low Pt-loading (2024 target: 0.14 mg cm-2 total Pt loading for LDV) need to be achieved. This makes the durability targets even more challenging. Thereby, the lifetime of a PEMFC stack is determined by i) material properties and ii) by operation strategy. Hence, to increase PEMFC durability, investigations are pursued to propose improved components [2,3] as well as to define appropriate operation conditions for different applications [4,5]. The performance limitations of PEMFC become substantial particularly at low Pt loadings [6] Moreover, performance and material degradation is particularly critical at low Pt loadings as well; in this context the cathode catalyst layer contributes the most to performance decay. The dissolution of Pt nanoparticles and the degradation of the carbon support as well as ionomer are dominating processes. One approach to mitigate performance degradation is the development of stabilized catalysts [7]. Low Pt loaded electrodes with the nano-cage stabilized Pt/C catalyst mitigate Pt dissolution, as will be shown in this presentation. The positive effect is clearly demonstrated by comparing the accelerated stress tests (ASTs) of a MEA with conventional Pt/C catalyst against a MEA with a stabilized Pt/C catalyst. In our tests, the conventional MEA exhibits dramatic ECSA loss, while it remains stable in case of the stabilized MEA as shown in panel (A) of the image. To assess durability of new MEA components, ASTs are necessarily required to avoid testing times of thousands of hours. Moreover, to provide realistic results, these ASTs need to simulate stressors occurring in the course of real operation conditions. To quantify the impact of specific operando stressors (such as high current density or high operation temperature) on individual MEA components (i.e. CCM and GDL), specific degradation tests have been carried out as part of the European ID-Fast project [8]. Progress on these investigations will be shown in this presentation. In addition, special focus is dedicated to the analysis of reversible degradation losses and the corresponding recovery procedures. Within this framework, different recovery protocols proposed in the literature as well as by projects funded by the European Commission and the DOE are compared. The second approach focuses on increasing the lifetime by optimizing operation conditions of the PEMFC stack [4]. This includes considering the power demand and dynamics of the subsystems and their balance of plant components in a hybrid system using a PEMFC and an energy storage system (i.e. battery or capacitor). Thereby the system power demand is derived from the velocity profiles of the target applications and has to be distributed between the subsystems. This approach allows mitigation of detrimental system operation, such as i) uncovered power demand, ii) discharged energy storage (no buffering of power peaks) and fully charged energy storage (no recuperation) and iii) excess of energy storage maximum charge current (partial buffering) as shown in panel (B) of the image. Moreover, faulty stack operation is mitigated thanks to using operando state-of-health monitoring. Acknowledgements This project has received funding from the Fuel Cells and Hydrogen 2 Joint Undertaking under grant agreement No 779565 (ID-Fast). This Joint Undertaking receives support from the European Union’s Horizon 2020 research and innovation programme. Moreover, financial support by German Federal Ministry of Education and Research through the COALA project (grant no. 01LX1601A of the Polish-German Sustainability Research Call STAIR II) is acknowledged. References [1] FCH 2 JU Multi-Annual Work Plan 2020-2024 (https://www.fch.europa.eu/page/multi-annual-work-plan) and FCH 2 JU Annual Work Plan 2020 (https://www.fch.europa.eu/node/843) [2] K. Talukdar, et al., J. Power Sources, 439, 227078 (2019). [3] K. Talukdar, et al., J. Power Sources, 427, 309 (2019). [4] J. Mitzel, et al., Int. J. Hydrogen Energy, 41, 21415 (2016). [5] J. Mitzel, et al., Fuel Cells (2020), https://doi.org/10.1002/fuce.201900193. [6] P. Gazdzicki, et al., Fuel Cells, 18, 270 (2017). [7] M. Sun, et al., Nano Res., 11, 3490 (2018). [8] P. Gazdzicki, et al., ECS Trans. 82, 261 (2019). Figure 1

  • Open Access

    Advancement of Segmented Cell Technology in Low Temperature Hydrogen Technologies

    by Indro Biswas, Daniel G. Sánchez, Mathias Schulze, Jens Mitzel, Benjamin Kimmel, Aldo Saul Gago, Pawel Gazdzicki, K. Andreas Friedrich

    The durability and performance of electrochemical energy converters, such as fuel cells and electrolysers, are not only dependent on the properties and the quality of the used materials. They strongly depend on the operational conditions. Variations in external parameters, such as flow, pressure, temperature and, obviously, load, can lead to significant local changes in current density, even local transients. Segmented cell technology was developed with the purpose to gain insight into the local operational conditions in electrochemical cells during operation. The operando measurement of the local current density and temperature distribution allows effective improvement of operation conditions, mitigation of potentially critical events and assessment of the performance of new materials. The segmented cell, which can replace a regular bipolar plate in the current state of the technology, can be used as a monitoring tool and for targeted developments. This article gives an overview of the development and applications of this technology, such as for water management or fault recognition. Recent advancements towards locally resolved monitoring of humidity and to current distributions in electrolysers are outlined.


  • Open Access

    Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis

    by J. Mitzel, J. Sanchez‐Monreal, D. Garcia‐Sanchez, P. Gazdzicki, M. Schulze, F. Häußler, J. Hunger, G. Schlumberger, E. Janicka, M. Mielniczek, et al.

    Starvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density distribution across the active area at the cell level was correlated with electrochemical impedance spectroscopy to enable operando fault diagnostic without any impact of the applied analytical tools on the single cell behavior. Moreover, the combination of both technologies allows in‐depth analysis of fault mechanisms in fuel cell single cells with improved sensitivity. Current density distribution and the quantitative assessment of the performance homogeneity demonstrated high sensitivity to small humidity changes and allow the detection of critical events, such as dry‐out in single cells. Impedance analysis is more sensitive regarding polarization and diffusion limitations and allows detection of cell flooding. The combination of both techniques is required for reliable identification of air starvation faults.


  • Looking Inside Polymer Electrolyte Membrane Fuel Cell Stack Using Tailored Electrochemical Methods

    by Piotr Piela, Jens Mitzel, Sébastien Rosini, Wojciech Tokarz, Francesco Valle, Alberto Pilenga, Thomas Malkow, Georgios Tsotridis

    Voltammetry, potentiometry, amperometry, and electrochemical impedance spectroscopy (EIS) were used to study practical polymer electrolyte membrane fuel cell (PEMFC) stacks in an attempt to validate the stack-tailored electrochemical methods and to show the range of information about a PEMFC stack obtainable with the methods. In-stack electrode voltammetry allowed to determine the type, i.e., the surface chemistry, of catalysts used to make the stack electrodes and to measure the electrodes' true active surface areas (EASAs). Stack potentiometry gave the EASAs, too, but only after calibration of the method against voltammetry. Speed of test is the advantage of stack potentiometry. An amperometry-based protocol was introduced to measure the hydrogen permeability and electronic shorting of the stack membrane-electrode assemblies. Dependence of the H2 permeability on H2 pressure and stack temperature was shown. EIS in the hydrogen-pump mode was used to study the anode and electrolyte membrane processes under load. Spectra were dominated by humidification effects, which allowed probing the external humidification distribution to the anodes in the stack. Cathode EIS spectra obtained by subtraction of H2-H2-mode spectra from H2-air-mode spectra were modeled and the ohmic, charge-transfer, and oxygen mass-transport contributions to the stack polarization under load were separated. The variability of these contributions across the stack was discussed.