Elisa Rubí
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elisa Rubí has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Rafael Cela
Department of Analytical Chemistry, Nutrition and Food Sciences, IIAA - Institute for Food Analysis and Research, Universidade de Santiago de Compostela, Constantino Candeira S/N, 15782 Santiago de Compostela, Spain
28 shared publications - Isaac Rodríguez
Department of Analytical Chemistry, Nutrition and Food Sciences, ARCUS - Aquatic One Health Research Centre, Universidade de Santiago de Compostela, R/Constantino Candeira, 5, 15782 Santiago de Compostela, Spain
26 shared publications - Noelia Negreira
Water and Soil Quality Research Group, Department of Environmental Chemistry, Institute of Environmental Assessment and Water Research (IDAEA-CSIC), Jordi Girona 18-26, E-08034, Barcelona, Spain
10 shared publications P. Canosa
Departamento de Química Analítica, Nutrición y Bromatología, Instituto de Investigación y Análisis Alimentario, Universidad de Santiago de Compostela, Avda de las Ciencias s/n., Santiago de Compostela 15782, Spain
9 shared publications- Maria Ramil
Department of Analytical Chemistry, Nutrition and Food Sciences, ARCUS - Aquatic One Health Research Centre, Universidade de Santiago de Compostela, R/Constantino Candeira, 5, 15782, Santiago de Compostela, Spain
8 shared publications - Rosa Montes
Universidade de Santiago de Compostela R. Constantino Candeira S/N, IIAA Building
7 shared publications
Latest Publications
- 1 September 2013
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 93 (11) , 1174-1188
Optimization of matrix solid-phase dispersion conditions for UV filters determination in biota samples
A low solvent consumption method for the determination of eight ultraviolet (UV) filters, displaying low to medium polarities, in freeze-dried samples of marine bivalves and fish is proposed. Matrix solid-phase dispersion (MSPD) and gas chromatography with mass spectrometry (GC-MS) were used as sample preparation and determination techniques, respectively. This work describes the influence of several parameters (type and amount of dispersant and clean-up sorbents, as well as elution solvent) on the yield and the selectivity of the MSPD extraction. Under optimized conditions, samples (0.5 g) were ground with 2 g of Florisil in a mortar with a pestle and transferred into a polypropylene syringe, which contained 1 g of C18 as clean-up sorbent. Analytes were eluted with 5 mL of acetonitrile. This extract was concentrated to dryness, re-constituted with 1 mL of ethyl acetate and injected in the GC-MS system without any further clean-up. The global average recoveries, measured for three different biota samples, spiked at three different levels (between 50 and 1000 ng g−1), ranged from 80% to 101% with associated standard deviations below 10%. The inter-day precision of the method varied from 4% to 15% and the achieved LOQs (defined for a signal to noise ratio of 10) ranged from 4 to 28 ng g−1, referred to the freeze-dried matrix. Octocrylene (OCR) was found in some samples of fish and mussels at concentrations between 15 and 20 ng g−1, referred to dry mass.
- 1 September 2013
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 93 (11) , 1174-1188
Optimization of matrix solid-phase dispersion conditions for UV filters determination in biota samples
A low solvent consumption method for the determination of eight ultraviolet (UV) filters, displaying low to medium polarities, in freeze-dried samples of marine bivalves and fish is proposed. Matrix solid-phase dispersion (MSPD) and gas chromatography with mass spectrometry (GC-MS) were used as sample preparation and determination techniques, respectively. This work describes the influence of several parameters (type and amount of dispersant and clean-up sorbents, as well as elution solvent) on the yield and the selectivity of the MSPD extraction. Under optimized conditions, samples (0.5 g) were ground with 2 g of Florisil in a mortar with a pestle and transferred into a polypropylene syringe, which contained 1 g of C18 as clean-up sorbent. Analytes were eluted with 5 mL of acetonitrile. This extract was concentrated to dryness, re-constituted with 1 mL of ethyl acetate and injected in the GC-MS system without any further clean-up. The global average recoveries, measured for three different biota samples, spiked at three different levels (between 50 and 1000 ng g−1), ranged from 80% to 101% with associated standard deviations below 10%. The inter-day precision of the method varied from 4% to 15% and the achieved LOQs (defined for a signal to noise ratio of 10) ranged from 4 to 28 ng g−1, referred to the freeze-dried matrix. Octocrylene (OCR) was found in some samples of fish and mussels at concentrations between 15 and 20 ng g−1, referred to dry mass.
- 17 August 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 402 (1) , 509-518
Determination of perfluorinated compounds in mollusks by matrix solid-phase dispersion and liquid chromatography–tandem mass spectrometry
Perfluorinated compounds (PFCs) have been used for over 40 years in different commercial and industrial applications mainly as surfactants and surface protectors and have become an important class of marine emerging pollutants. This study presents the development and validation of a new analytical method to determine the simultaneous presence of eight PFCs in different kinds of mollusks using matrix solid-phase dispersion (MSPD) followed by liquid chromatography–tandem mass spectrometry (LC-MS/MS). Simplicity of the analytical procedure, low volume of solvent and quantity of sample required, low global price, and integration of extraction and clean-up into a single step, are the most important advantages of the developed methodology. Solvent, solid support (dispersing agent), clean-up sorbent, and their amounts were optimized by means of an experimental design. In the final method, 0.5 g of sample are dispersed with 0.2 g of diatomaceous earth and transferred into a polypropylene syringe containing 4 g of silica as clean-up sorbent. Then, analytes are eluted with 20 mL of acetonitrile. The extract is finally concentrated to a final volume of 0.5 mL in methanol, avoiding extract dryness in order to prevent evaporation losses and injected in the LC-MS/MS. The combination of this MSPD protocol with LC-MS/MS afforded detection limits from 0.05 to 0.3 ng g−1. Also, a good linearity was established for the eight PFCs in the range from limit of quantification (LOQ) to 500 ng mL−1 with R 2 > 0.9917. The recovery of the method was studied with three types of spiked mollusk and was in the 64–126% range. Moreover, a mussel sample was spiked and aged for more than 1 month and analyzed by the developed method and a reference method, ion-pair extraction, for comparison, producing both methods statistically equal concentration values. The method was finally applied to the determination of PFCs in different kinds of mollusks revealing concentrations up to 8.3 ng g−1 for perfluoroundecanoic acid.
- 17 August 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 402 (1) , 509-518
Determination of perfluorinated compounds in mollusks by matrix solid-phase dispersion and liquid chromatography–tandem mass spectrometry
Perfluorinated compounds (PFCs) have been used for over 40 years in different commercial and industrial applications mainly as surfactants and surface protectors and have become an important class of marine emerging pollutants. This study presents the development and validation of a new analytical method to determine the simultaneous presence of eight PFCs in different kinds of mollusks using matrix solid-phase dispersion (MSPD) followed by liquid chromatography–tandem mass spectrometry (LC-MS/MS). Simplicity of the analytical procedure, low volume of solvent and quantity of sample required, low global price, and integration of extraction and clean-up into a single step, are the most important advantages of the developed methodology. Solvent, solid support (dispersing agent), clean-up sorbent, and their amounts were optimized by means of an experimental design. In the final method, 0.5 g of sample are dispersed with 0.2 g of diatomaceous earth and transferred into a polypropylene syringe containing 4 g of silica as clean-up sorbent. Then, analytes are eluted with 20 mL of acetonitrile. The extract is finally concentrated to a final volume of 0.5 mL in methanol, avoiding extract dryness in order to prevent evaporation losses and injected in the LC-MS/MS. The combination of this MSPD protocol with LC-MS/MS afforded detection limits from 0.05 to 0.3 ng g−1. Also, a good linearity was established for the eight PFCs in the range from limit of quantification (LOQ) to 500 ng mL−1 with R 2 > 0.9917. The recovery of the method was studied with three types of spiked mollusk and was in the 64–126% range. Moreover, a mussel sample was spiked and aged for more than 1 month and analyzed by the developed method and a reference method, ion-pair extraction, for comparison, producing both methods statistically equal concentration values. The method was finally applied to the determination of PFCs in different kinds of mollusks revealing concentrations up to 8.3 ng g−1 for perfluoroundecanoic acid.
- 19 February 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (2) , 603-611
Silicone discs as disposable enrichment probes for gas chromatography-mass spectrometry determination of UV filters in water samples
This work describes an effective, low solvent consumption and affordable sample preparation approach for the determination of eight UV filters in surface and wastewater samples. It involves sorptive extraction of target analytes in a disposable, technical grade silicone disc (5 mm diameter × 0.6 mm thickness) followed by organic solvent desorption, large volume injection (LVI), and gas chromatography-mass spectrometry determination. Final working conditions involved overnight extraction of 100-mL samples, containing 10% of methanol, followed by analytes desorption with 0.2 mL of ethyl acetate. The method provides linear responses between the limits of quantification (from 0.003 to 0.040 ng mL−1) and 10 ng mL−1, an intra-day precision below 13%, and low matrix effects for surface, swimming pool, and treated sewage water samples. Moreover, the extraction yields provided by silicone discs were in excellent agreement with those achieved using polydimethylsiloxane-covered stir bars. Several UV filters were found in surface and sewage water samples, with the maximum concentrations corresponding to octocrylene.
- 19 February 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (2) , 603-611
Silicone discs as disposable enrichment probes for gas chromatography-mass spectrometry determination of UV filters in water samples
This work describes an effective, low solvent consumption and affordable sample preparation approach for the determination of eight UV filters in surface and wastewater samples. It involves sorptive extraction of target analytes in a disposable, technical grade silicone disc (5 mm diameter × 0.6 mm thickness) followed by organic solvent desorption, large volume injection (LVI), and gas chromatography-mass spectrometry determination. Final working conditions involved overnight extraction of 100-mL samples, containing 10% of methanol, followed by analytes desorption with 0.2 mL of ethyl acetate. The method provides linear responses between the limits of quantification (from 0.003 to 0.040 ng mL−1) and 10 ng mL−1, an intra-day precision below 13%, and low matrix effects for surface, swimming pool, and treated sewage water samples. Moreover, the extraction yields provided by silicone discs were in excellent agreement with those achieved using polydimethylsiloxane-covered stir bars. Several UV filters were found in surface and sewage water samples, with the maximum concentrations corresponding to octocrylene.
- 1 January 2011
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (2) , 211-217
Optimization of pressurized liquid extraction and purification conditions for gas chromatography–mass spectrometry determination of UV filters in sludge
- 1 January 2011
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (2) , 211-217
Optimization of pressurized liquid extraction and purification conditions for gas chromatography–mass spectrometry determination of UV filters in sludge
- 22 July 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (2) , 995-1004
Dispersive liquid–liquid microextraction followed by gas chromatography–mass spectrometry for the rapid and sensitive determination of UV filters in environmental water samples
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1. Figure 1
- 22 July 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 398 (2) , 995-1004
Dispersive liquid–liquid microextraction followed by gas chromatography–mass spectrometry for the rapid and sensitive determination of UV filters in environmental water samples
The performance of the dispersive liquid–liquid microextraction (DLLME) technique for the determination of eight UV filters and a structurally related personal care species, benzyl salicylate (BzS), in environmental water samples is evaluated. After extraction, analytes were determined by gas chromatography combined with mass spectrometry detection (GC-MS). Parameters potentially affecting the performance of the sample preparation method (sample pH, ionic strength, type and volume of dispersant and extractant solvents) were systematically investigated using both multi- and univariant optimization strategies. Under final working conditions, analytes were extracted from 10 mL water samples by addition of 1 mL of acetone (dispersant) containing 60 μL of chlorobenzene (extractant), without modifying either the pH or the ionic strength of the sample. Limits of quantification (LOQs) between 2 and 14 ng L−1, inter-day variability (evaluated with relative standard deviations, RSDs) from 9% to 14% and good linearity up to concentrations of 10,000 ng L−1 were obtained. Moreover, the efficiency of the extraction was scarcely affected by the type of water sample. With the only exception of 2-ethylhexyl-p-dimethylaminobenzoate (EHPABA), compounds were found in environmental water samples at concentrations between 6 ± 1 ng L−1 and 26 ± 2 ng mL−1. Figure 1
- 1 November 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 654 (2) , 162-170
Solid-phase extraction followed by liquid chromatography–tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samples
- 1 November 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 654 (2) , 162-170
Solid-phase extraction followed by liquid chromatography–tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samples
- 1 July 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (29) , 5459-5466
Solid-phase extraction followed by dispersive liquid–liquid microextraction for the sensitive determination of selected fungicides in wine
- 1 July 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (29) , 5459-5466
Solid-phase extraction followed by dispersive liquid–liquid microextraction for the sensitive determination of selected fungicides in wine
- 1 July 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (31) , 5895-5902
Determination of selected UV filters in indoor dust by matrix solid-phase dispersion and gas chromatography–tandem mass spectrometry
- 1 July 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (31) , 5895-5902
Determination of selected UV filters in indoor dust by matrix solid-phase dispersion and gas chromatography–tandem mass spectrometry