IJIan R. Jandrell

Ian R. Jandrell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ian R. Jandrell has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Changing The Mindset: The Lecturer’s Responsibility When Presenting A First Year Course.

    by George Gibbon, Ian Jandrell

    Changing the Mindset: The Lecturer’s Responsibility when Presenting a First Year Course. Abstract Students entering tertiary education are coming from a predominantly procedural learning (rote) background and are unprepared to perform in a predominantly conceptual thinking (relationship between items of knowledge) environment. Since 2004 changes have been implemented in the Electric Circuits course to develop both conceptual and critical thinking. This has resulted in an increased pass rate for the course. However, analysis of the exam papers and second year success revealed that the student’s were optimizing their success by leaving out sections of the work that they regarded as “difficult”. As all the sections are the essential basic knowledge required for the second year courses the course and the final exam was divided into four topics all of which must be passed to pass the course. Initial results indicate that many students have changed their preparation process to comply with the new rules. Introduction Students entering tertiary education are coming from a predominantly procedural learning background and are unprepared to perform in a predominantly conceptual thinking engineering education environment. The definitions of procedural and conceptual learning, in terms of engineering education, are best described by McCormick1. Procedural knowledge is defined as “know how to do it” knowledge, best mastered by rote learning, while conceptual knowledge “is the relationship between ‘items’ of knowledge”. This inability to think and learn conceptually is not always apparent in the first year at university, as the courses are presented at the introductory level of basic concepts and “language”, and the students can still achieve success by applying their well developed rote learning skills. Since 2004 changes have been implemented in the Electric Circuits course, one of two engineering courses in first year, to develop conceptual and critical thinking in our first year students. Our students come from diverse secondary school backgrounds; some are well resourced while others are almost hopelessly under resourced in terms of facilities, teaching materials and teaching staff. Many of the students are also studying engineering for reasons that do not include an interest in, or an aptitude for, engineering. Some of the reasons are the availability of scholarships and bursaries to study engineering, parental pressure and future financial security after obtaining an engineering degree. In 2004 the changes included extending the course over two semesters, adding a critical thinking component and changing the laboratory concepts. In 2005 formal tutorials were dropped and self-learning concept in the laboratories was extended. Developing a “global” learning approach by integrating the laboratory tasks with the lectures was introduced in 2007. In 2009 the requirement for the students to pass all topics in the course to pass the course, and not just an aggregate mark, was introduced.

  • Students’ t-distribution modelling of LLS location errors

    by Hugh G.P. Hunt, Wolfgang Schulz, Ken J. Nixon, Ian R. Jandrell

    This paper investigates the statistical distribution that best describes Lightning Location System location errors. It is generally assumed that the bivariate Gaussian distribution is a good description but the presence of outliers calls for a heavier-tailed distribution. The bivariate Students' t-distribution is proposed. Using Maximum Likelihood Estimation, Mahalanobis quality-of-fit tests and ground-truth events to the Brixton tower, South Africa and Gaisberg tower, Austria, we are able to show that the bivariate Students' t-distribution is a better fit than the bivariate Gaussian distribution.


  • LPS design and risk analysis of a control and observation centre for rocket triggered lightning experiments

    by A.S. Dickson, Grant, I.R. Jandrell, K.J. Nixon

    A control and observation centre for rocket triggered lightning research has been constructed. A risk analysis performed using IEC 62305-2 shows that the risk of loss of life within the structure under normal conditions is well below the tolerable risk level. By adjusting the equations defined in the risk standard risks associated with individual events can be calculated. The implication of these on personal risk is still uncertain. By using methods highlighted in the standards a visual understanding of personal risk can be obtained. The implication of this is that an external lightning protection system is required. The safety of personal and equipment at the control and observation centre is critical. This paper discusses the design of the lightning protection system design and installed for the control and observation centre.

  • A method to measure the application of the incident investigation process for electrical incidents

    by Zarheer Jooma, Jessica Hutchings, Hugh Hoagland, Ian R Jandrell

    Electrical incidents provide a good learning opportunity. If an organization fails to capitalize on this opportunity, the incident could recur. An abundance of literature is available on the investigation process and various investigation techniques. There appears to be limited guidance on determining the effectiveness of the application of the investigation process after the investigation is complete. As part of a larger research project, a comprehensive study was undertaken at a steel plant in South Africa to address this gap.

  • Mean life estimation of metal oxide surge arresters under harmonic distortion

    by P. Bokoro, I. Jandrell

    In this paper, similar metal oxide-based arresters are tested using accelerated ageing tests with low and high total harmonic distortion content in the AC voltage stress. The extrapolated ageing times obtained are modelled using the three-parameter Weibull statistical distribution. The hypothesis testing based on the likelihood ratio test is invoked in order to ensure no possibility of equal probability density functions, which are therefore applied to estimate or predict the mean life of MOSA under distorted ac voltage stress. The results obtained indicate that the likelihood ratio test is found to be -1.2855 and the mean life obtained for MOSA samples aged with a total harmonic distortion content of 8.5% in the voltage stress is reduced by 30.13%.


  • The impact of harmonics on the V − I characteristic of ZnO varistors

    by P. Bokoro, I. Jandrell

    The continued presence of harmonic frequencies in modern power systems raises the fundamental question of suspected aggravation of ageing or degradation process of zinc oxide (ZnO) varistors under constant operating voltage mode. In this study, the long-term effect of power system harmonics on the ageing of ZnO varistor samples is analysed on the basis of the reference or the varistor voltage and the coefficient of non-linearity, which are measured from the voltage-current charactristic (V - I). The results obtained indicate that for an increase in the total harmonic distortion (THD) from 1.5 % to 8.47 % in the continuously applied voltage, at a constant temperature of 135°C, a decrease of 66.29 % in the reference voltage, and that of 76.92 % in the coefficient of non-linearity are observed in the varistor units exposed to higher content of harmonic-distortion.


  • The Analysis of an Incident Investigation System

    by Zarheer Jooma, Jessica Hutchings, Elihu Hoagland, Ian R. Jandrell

    Electrical incidents provide valuable learning opportunities if root causes are identified. Incident investigations which are unable to identify all root causes and address the shortcomings in the safety management system may result in recurring incidents. It is important that the entire incident investigation programme be guided by proven techniques and executed in a well-established manner. In a white paper titled “The Development of Questions to Determine the Effectiveness of the Incident Investigation Process for Electrical Incidents,” the authors analyzed commonly applied incident investigation techniques and suggested six salient incident investigation process requirements irrespective of the techniques used. This paper also suggested eight constructs, which could be used to determine the effectiveness of the incident investigation process. This paper utilizes the established learning and applies it to a large steel plant. A number of serious electrical incidents spanning many years at different operating units were analytically reviewed. A study of the organizational policy and one completed incident investigation report is analyzed to determine the effectiveness of the incident investigation process. Shortcomings in the process are discussed and possible salient practices that derogate from effective investigations are proposed. This paper forms part of a larger research project to determine the effectiveness of the application of the incident investigation process. The results and recommendations from the study aim to provide generic benchmarking of the incident investigation process, which could be used by organizations to improve its electrical safety performance.


  • The analysis of an incident investigation system

    by Zarheer Jooma, Jessica Hutchings, Hugh Hoagland, Ian R Jandrell

    Electrical incidents provide valuable learning opportunities if root causes are identified. Incident investigations which are unable to identify all root causes and address the shortcomings in the safety management system may result in recurring incidents. It is important that the entire incident investigation programme be guided by proven techniques and executed in a well-established manner. In a white paper titled “The Development of Questions to Determine the Effectiveness of the Incident Investigation Process for Electrical Incidents”, the authors analysed commonly applied incident investigation techniques and suggested six salient incident investigation process requirements irrespective of the techniques used. The paper also suggested eight latent traits, which could be used to determine the effectiveness of the incident investigation process. This paper utilises the established learning and applies it to a large steel plant. A number of serious electrical incidents, spanning many years, at different operating units were analytically reviewed. A study of the organisational policy and one completed incident investigation report is analysed to determine the effectiveness of the incident investigation process. Shortcomings in the process are discussed and possible salient practises which derogate from effective investigations are proposed. This paper forms part of a larger research project to determine the effectiveness of the application of the incident investigation process. The results and recommendations from the study aim to provide generic benchmarking of the incident investigation process, which could be used by organizations to improve its electrical safety performance.