Nick F. J. Hilgersom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Nick F. J. Hilgersom has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Denise Eygendaal
11 shared publicationsMichel P. J. van Den Bekerom
Onze Lieve Vrouwe Gasthuis
5 shared publicationsBertram The
3 shared publicationsMichel P J van Den Bekerom
Department of Orthopaedic Surgery
2 shared publicationsAndrea Celli
1 shared publicationAndreas Lenich
1 shared publication
Latest Publications
- 2 November 2022
- Published by Springer Nature
- p. 305-312
Distal Biceps Reconstruction with Allograft for Chronic Tears
- 2 November 2022
- Published by Springer Nature
- p. 305-312
Distal Biceps Reconstruction with Allograft for Chronic Tears
- Open Access
- 21 July 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , 2157-2163
Three weeks of indomethacin is not superior to 1 week of meloxicam as prophylaxis for heterotopic ossifications after distal biceps tendon repair with a single-incision technique
- 21 July 2022
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 31 (10) , 2157-2163
Open AccessThree weeks of indomethacin is not superior to 1 week of meloxicam as prophylaxis for heterotopic ossifications after distal biceps tendon repair with a single-incision technique
- Open Access
- 4 September 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (12) , 4075-4081
Greater radial tuberosity size is associated with distal biceps tendon rupture: a quantitative 3‐D CT case–control study
Purpose: During pronation, the distal biceps tendon and radial tuberosity internally rotate into the radioulnar space, reducing the linear distance between the radius and ulna by approximately 50%. This leaves a small space for the distal biceps tendon to move in and could possibly cause mechanical impingement or rubbing of the distal biceps tendon. Hypertrophy of the radial tuberosity potentially increases the risk of mechanical impingement of the distal biceps tendon. The purpose of our study was to determine if radial tuberosity size is associated with rupturing of the distal biceps tendon. Methods: Nine patients with a distal biceps tendon rupture who underwent CT were matched 1:2 to controls without distal biceps pathology. A quantitative 3‐dimensional CT technique was used to calculate the following radial tuberosity characteristics: 1) volume in mm3, 2) surface area in mm2, 3) maximum height in mm and 4) location (distance in mm from the articular surface of the radial head).Results: Analysis of the 3‐dimensional radial tuberosity CT‐models showed larger radial tuberosity volume and maximum height in the distal biceps tendon rupture group compared to the control group. Mean radial tuberosity volume in the rupture‐group was 705 mm3 (SD: 222 mm3) compared to 541 mm3 (SD: 184 mm3) in the control group (p = 0.033). Mean radial tuberosity maximum height in the rupture‐group was 4.6 mm (SD: 0.9 mm) compared to 3.7 mm (SD: 1.1 mm) in the control group, respectively (p = 0.011). There was no statistically significant difference in radial tuberosity surface area (ns) and radial tuberosity location (ns).Conclusion: Radial tuberosity volume and maximum height were significantly greater in patients with distal biceps tendon ruptures compared to matched controls without distal biceps tendon pathology. This supports the theory that hypertrophy of the radial tuberosity plays a role in developing distal biceps tendon pathology.Level of evidence: Level III.
- 4 September 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 29 (12) , 4075-4081
Open AccessGreater radial tuberosity size is associated with distal biceps tendon rupture: a quantitative 3‐D CT case–control study
Purpose: During pronation, the distal biceps tendon and radial tuberosity internally rotate into the radioulnar space, reducing the linear distance between the radius and ulna by approximately 50%. This leaves a small space for the distal biceps tendon to move in and could possibly cause mechanical impingement or rubbing of the distal biceps tendon. Hypertrophy of the radial tuberosity potentially increases the risk of mechanical impingement of the distal biceps tendon. The purpose of our study was to determine if radial tuberosity size is associated with rupturing of the distal biceps tendon. Methods: Nine patients with a distal biceps tendon rupture who underwent CT were matched 1:2 to controls without distal biceps pathology. A quantitative 3‐dimensional CT technique was used to calculate the following radial tuberosity characteristics: 1) volume in mm3, 2) surface area in mm2, 3) maximum height in mm and 4) location (distance in mm from the articular surface of the radial head).Results: Analysis of the 3‐dimensional radial tuberosity CT‐models showed larger radial tuberosity volume and maximum height in the distal biceps tendon rupture group compared to the control group. Mean radial tuberosity volume in the rupture‐group was 705 mm3 (SD: 222 mm3) compared to 541 mm3 (SD: 184 mm3) in the control group (p = 0.033). Mean radial tuberosity maximum height in the rupture‐group was 4.6 mm (SD: 0.9 mm) compared to 3.7 mm (SD: 1.1 mm) in the control group, respectively (p = 0.011). There was no statistically significant difference in radial tuberosity surface area (ns) and radial tuberosity location (ns).Conclusion: Radial tuberosity volume and maximum height were significantly greater in patients with distal biceps tendon ruptures compared to matched controls without distal biceps tendon pathology. This supports the theory that hypertrophy of the radial tuberosity plays a role in developing distal biceps tendon pathology.Level of evidence: Level III.
- Open Access
- 1 December 2020
- Published by Elsevier in JSES International
- Vol. 4 (4) , 1031-1036
Arthroscopic localization of the ulnar nerve behind the medial capsule is unreliable
- 1 December 2020
- Published by Elsevier in JSES International
- Vol. 4 (4) , 1031-1036
Open AccessArthroscopic localization of the ulnar nerve behind the medial capsule is unreliable
- 15 October 2019
- Published by Springer Nature
- p. 683-686
Osteochondritis Dissecans of the Elbow: Arthroscopic Debridement
- 15 October 2019
- Published by Springer Nature
- p. 683-686
Osteochondritis Dissecans of the Elbow: Arthroscopic Debridement
- Open Access
- 23 August 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (10) , 3254-3260
Locating the ulnar nerve during elbow arthroscopy using palpation is only accurate proximal to the medial epicondyle
Purpose: Knowledge of ulnar nerve position is of utmost importance to avoid iatrogenic injury in elbow arthroscopy. The aim of this study was to determine how accurate surgeons are in locating the ulnar nerve after fluid extravasation has already occurred, and basing their localization solely on palpation of anatomical landmarks.Methods: Seven cadaveric elbows were used and seven experienced surgeons in elbow arthroscopy participated. An arthroscopic setting was simulated and fluids were pumped into the joint from the posterior compartment for 15 min. For each cadaveric elbow, one surgeon was asked to locate the ulnar nerve solely by palpation of the anatomical landmarks, and subsequently pin the ulnar nerve at two positions: within 5 cm proximal and another within 5 cm distal of a line connecting the medial epicondyle and the tip of the olecranon. Subsequently, the elbows were dissected using a standard medial elbow approach and the distances between the pins and ulnar nerve were measured.Results: The median distance between the ulnar nerve and the proximal pins was 0 mm (range 0–0 mm), and between the ulnar nerve and the distal pins was 2 mm (range 0–10 mm), showing a statistically significant difference (p = 0.009). All seven proximally placed pins (100%) transfixed the ulnar nerve versus two out of seven distally placed pins (29%) (p = 0.021).Conclusions: In a setting simulating an already initiated arthroscopic procedure, the sole palpation of the anatomical landmarks allows experienced elbow surgeons to accurately locate the ulnar nerve only in its course proximal to the medial epicondyle (7/7, 100%), whereas a significantly reduced accuracy is documented when the same surgeons attempt to locate the nerve distal to the medial epicondyle (2/7, 29%; p = 0.021). Current findings support the establishment of a proximal anteromedial portal over a distal anteromedial portal to access the anterior compartment after tissue extravasation has occurred with regard to ulnar nerve safety.
- 23 August 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (10) , 3254-3260
Open AccessLocating the ulnar nerve during elbow arthroscopy using palpation is only accurate proximal to the medial epicondyle
Purpose: Knowledge of ulnar nerve position is of utmost importance to avoid iatrogenic injury in elbow arthroscopy. The aim of this study was to determine how accurate surgeons are in locating the ulnar nerve after fluid extravasation has already occurred, and basing their localization solely on palpation of anatomical landmarks.Methods: Seven cadaveric elbows were used and seven experienced surgeons in elbow arthroscopy participated. An arthroscopic setting was simulated and fluids were pumped into the joint from the posterior compartment for 15 min. For each cadaveric elbow, one surgeon was asked to locate the ulnar nerve solely by palpation of the anatomical landmarks, and subsequently pin the ulnar nerve at two positions: within 5 cm proximal and another within 5 cm distal of a line connecting the medial epicondyle and the tip of the olecranon. Subsequently, the elbows were dissected using a standard medial elbow approach and the distances between the pins and ulnar nerve were measured.Results: The median distance between the ulnar nerve and the proximal pins was 0 mm (range 0–0 mm), and between the ulnar nerve and the distal pins was 2 mm (range 0–10 mm), showing a statistically significant difference (p = 0.009). All seven proximally placed pins (100%) transfixed the ulnar nerve versus two out of seven distally placed pins (29%) (p = 0.021).Conclusions: In a setting simulating an already initiated arthroscopic procedure, the sole palpation of the anatomical landmarks allows experienced elbow surgeons to accurately locate the ulnar nerve only in its course proximal to the medial epicondyle (7/7, 100%), whereas a significantly reduced accuracy is documented when the same surgeons attempt to locate the nerve distal to the medial epicondyle (2/7, 29%; p = 0.021). Current findings support the establishment of a proximal anteromedial portal over a distal anteromedial portal to access the anterior compartment after tissue extravasation has occurred with regard to ulnar nerve safety.
- Open Access
- 1 March 2018
- Published by Elsevier in Journal of ISAKOS
- Vol. 3 (2) , 116-124
Review of Poehling et al (1989) on elbow arthroscopy: a new technique
This classic discusses the original publication ‘Elbow Arthroscopy: A New Technique’ by Poehling et al, published in 1989 in The Journal of Arthroscopic and Related Surgery on the introduction of the prone position and the proximal medial portal to elbow arthroscopy. The first attempt to perform elbow arthroscopy was on a cadaveric specimen by Burman in 1931, after which it took approximately 50 years until the first reports on the successful clinical use of elbow arthroscopy were published. By then patients were commonly placed in the supine(-suspended) position, wherein access to the posterior compartment was somewhat difficult, and entry to the anterior compartment of the elbow was commonly established using anteromedial and anterolateral portals, which were increasingly associated with nerve injury. In 1989, Poehling et al published on the successful clinical use of two new techniques: the prone position and the proximal medial portal. The proximal medial portal meant a first established safe and reproducible entry into the anterior compartment of the elbow that is still commonly used today. With these techniques, Poehling et al improved visualisation of the elbow joint and showed that elbow arthroscopy could be performed safely and reliably despite the closeness of neurovascular structures, transitioning elbow arthroscopy from being pioneer work into a safe surgical procedure that would become part of the common orthopaedic practice. This classic places the work of Poehling et al in a historic perspective, discusses its impact at the time and relates it to scientific developments up to the present day.
- 1 March 2018
- Published by Elsevier in Journal of ISAKOS
- Vol. 3 (2) , 116-124
Open AccessReview of Poehling et al (1989) on elbow arthroscopy: a new technique
This classic discusses the original publication ‘Elbow Arthroscopy: A New Technique’ by Poehling et al, published in 1989 in The Journal of Arthroscopic and Related Surgery on the introduction of the prone position and the proximal medial portal to elbow arthroscopy. The first attempt to perform elbow arthroscopy was on a cadaveric specimen by Burman in 1931, after which it took approximately 50 years until the first reports on the successful clinical use of elbow arthroscopy were published. By then patients were commonly placed in the supine(-suspended) position, wherein access to the posterior compartment was somewhat difficult, and entry to the anterior compartment of the elbow was commonly established using anteromedial and anterolateral portals, which were increasingly associated with nerve injury. In 1989, Poehling et al published on the successful clinical use of two new techniques: the prone position and the proximal medial portal. The proximal medial portal meant a first established safe and reproducible entry into the anterior compartment of the elbow that is still commonly used today. With these techniques, Poehling et al improved visualisation of the elbow joint and showed that elbow arthroscopy could be performed safely and reliably despite the closeness of neurovascular structures, transitioning elbow arthroscopy from being pioneer work into a safe surgical procedure that would become part of the common orthopaedic practice. This classic places the work of Poehling et al in a historic perspective, discusses its impact at the time and relates it to scientific developments up to the present day.
- Open Access
- 1 January 2018
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 5 (1) , 45
Force measurement metrics for simulated elbow arthroscopy training
Background: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training.Methods: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3‐dimensional measurements (x‐, y‐, and z‐plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (Fabs) and force direction exerted (α and β) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and β being the angle in the vertical plane. The 10th–90th percentiles of the data were used to set threshold levels for training.Results: The median Fabs was 24 N (19 N – 30 N), 27 N (20 N – 33 N) and 29 N (23 N – 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was ‐ 29° (‐ 55° – 5°), ‐ 23° (‐ 56° – ‐1°) and 4° (‐ 22° – ‐18°) for the posterior, posterolateral and anterior compartment, respectively. The median β was ‐ 71° (‐ 80° – ‐65°), ‐ 76° (‐ 86° – ‐69°) and ‐ 75° (‐ 81° – ‐71°) for the posterior, posterolateral and anterior compartment, respectively.Conclusion: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of Fabs) exerted on the elbow tissue, and the 10th–90th percentile range of the force directions (α and β) for each compartment may be used to provide objective feedback during arthroscopic skills training.
- 1 January 2018
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 5 (1) , 45
Open AccessForce measurement metrics for simulated elbow arthroscopy training
Background: Elbow arthroscopy is a difficult surgical technique. Objective metrics can be used to improve safe and effective training in elbow arthroscopy. Force exerted on the elbow tissue during arthroscopy can be a measure of safe tissue manipulation. The purpose of this study was to determine the force magnitude and force direction used by experts during arthroscopic elbow navigation in cadaveric specimens and assess their applicability in elbow arthroscopy training.Methods: Two cadaveric elbows were mounted on a Force Measurement Table (FMT) that allowed 3‐dimensional measurements (x‐, y‐, and z‐plane) of the forces exerted on the elbow. Five experts in elbow arthroscopy performed arthroscopic navigation once in each of two cadaveric elbows, navigating through the posterior, posterolateral and anterior compartment in a standardized fashion with visualization of three to four anatomic landmarks per compartment. The total absolute force (Fabs) and force direction exerted (α and β) on the elbow during arthroscopy were recorded. α being the angle in the horizontal plane and β being the angle in the vertical plane. The 10th–90th percentiles of the data were used to set threshold levels for training.Results: The median Fabs was 24 N (19 N – 30 N), 27 N (20 N – 33 N) and 29 N (23 N – 32 N) for the posterior, posterolateral and anterior compartment, respectively. The median α was ‐ 29° (‐ 55° – 5°), ‐ 23° (‐ 56° – ‐1°) and 4° (‐ 22° – ‐18°) for the posterior, posterolateral and anterior compartment, respectively. The median β was ‐ 71° (‐ 80° – ‐65°), ‐ 76° (‐ 86° – ‐69°) and ‐ 75° (‐ 81° – ‐71°) for the posterior, posterolateral and anterior compartment, respectively.Conclusion: Expert data on force magnitude and force direction exerted on the elbow during arthroscopic navigation in cadaveric specimens were collected. The proposed maximum allowable force of 30 N (smallest 90th percentile of Fabs) exerted on the elbow tissue, and the 10th–90th percentile range of the force directions (α and β) for each compartment may be used to provide objective feedback during arthroscopic skills training.
- 20 September 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (1) , 318-324
Nerve injuries do occur in elbow arthroscopy
The purpose is to create more awareness as well as emphasize the risk of permanent nerve injury as a complication of elbow arthroscopy.
- 20 September 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 26 (1) , 318-324
Nerve injuries do occur in elbow arthroscopy
The purpose is to create more awareness as well as emphasize the risk of permanent nerve injury as a complication of elbow arthroscopy.