Claudio Cianfrini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Claudio Cianfrini has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Massimo Corcione
Department of Electrical and Energy Engineering (DIEE), Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy
16 shared publications - Emanuele Habib
University of Rome "La Sapienza
8 shared publications - Alessandro Quintino
Department of Electrical and Energy Engineering (DIEE), Sapienza University of Rome, Via Eudossiana 18, 00184 Rome, Italy
5 shared publications - Lucia Fontana
Dipartimento di Architettura, Università degli Studi Roma Tre, Via Madonna dei Monti 40, 00184 Roma, Italy
3 shared publications A. D'Orazio
1 shared publicationD.M Fontana
1 shared publication
Latest Publications
- 24 July 2015
- Published by Pushpa Publishing House in JP Journal of Heat and Mass Transfer
- Vol. 12 (1) , 65-88
CORRELATIONS FOR TRANSIENT THERMAL CONVECTION OF WATER NEAR ITS DENSITY-INVERSION POINT IN A SQUARE ENCLOSURE HEATED FROM BELOW
- 24 July 2015
- Published by Pushpa Publishing House in JP Journal of Heat and Mass Transfer
- Vol. 12 (1) , 65-88
CORRELATIONS FOR TRANSIENT THERMAL CONVECTION OF WATER NEAR ITS DENSITY-INVERSION POINT IN A SQUARE ENCLOSURE HEATED FROM BELOW
- 1 November 2014
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 48, 123-134
Buoyancy-induced convection in /water nanofluids from an enclosed heater- 1 November 2014
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 48, 123-134
Buoyancy-induced convection in /water nanofluids from an enclosed heater- 1 February 2014
- Published by Elsevier in Energy and Buildings
- Vol. 69, 490-497
Energy performance of air-conditioning systems using an indirect evaporative cooling combined with a cooling/reheating treatment
- 1 February 2014
- Published by Elsevier in Energy and Buildings
- Vol. 69, 490-497
Energy performance of air-conditioning systems using an indirect evaporative cooling combined with a cooling/reheating treatment
- 10 January 2013
- Published by Springer Nature in Journal of Thermal Science
- Vol. 22 (1) , 55-63
Convective transport in rectangular cavities partially heated at the bottom and cooled at one side
- 10 January 2013
- Published by Springer Nature in Journal of Thermal Science
- Vol. 22 (1) , 55-63
Convective transport in rectangular cavities partially heated at the bottom and cooled at one side
- 1 July 2012
- Published by Elsevier in Energy and Buildings
- Vol. 50, 26-34
Energy performance of a lightweight opaque ventilated façade integrated with the HVAC system using saturated exhaust indoor air
- 1 July 2012
- Published by Elsevier in Energy and Buildings
- Vol. 50, 26-34
Energy performance of a lightweight opaque ventilated façade integrated with the HVAC system using saturated exhaust indoor air
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 1246-1251
Free Convection Heat Transfer from a Row of Horizontal Cylinders
Steady laminar free convection in air from parallel circular cylinders set side-by-side is studied numerically. The SIMPLE-C algorithm is used for the solution of the mass, momentum, and energy transfer governing equations. Simulations are performed for tube-arrays consisting of 10 equally-spaced cylinders, for different center-to-center separation distances in the range between 1.4 and 6 cylinder-diameters, and for Rayleigh numbers spanning between 101 and 105.
- 1 January 2012
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 452-453, 1246-1251
Free Convection Heat Transfer from a Row of Horizontal Cylinders
Steady laminar free convection in air from parallel circular cylinders set side-by-side is studied numerically. The SIMPLE-C algorithm is used for the solution of the mass, momentum, and energy transfer governing equations. Simulations are performed for tube-arrays consisting of 10 equally-spaced cylinders, for different center-to-center separation distances in the range between 1.4 and 6 cylinder-diameters, and for Rayleigh numbers spanning between 101 and 105.
- 1 July 2008
- Published by SAGE Publications in Noise & Vibration Worldwide
- Vol. 39 (7) , 11-20
Screening Performance of Pairs of Diffusively Reflecting Traffic Noise Barriers: Theory and Experiments
An easy-to-apply computational procedure for the study of the acoustic performance of pairs of diffusively reflecting roadside barriers is described in detail, and an experimental verification of its predictions, carried out on a 1:10 scale model, is presented and discussed. It is shown that, in comparison with pairs of more traditional specularly reflecting noise barriers, significant attenuation benefits are obtained not only in the shadow zone behind the barriers, but also in the unprotected zone immediately above the barriers, which proves that diffusive traffic faces of the barriers may effectively help in counteracting multiple reflection effects.
- 1 July 2008
- Published by SAGE Publications in Noise & Vibration Worldwide
- Vol. 39 (7) , 11-20
Screening Performance of Pairs of Diffusively Reflecting Traffic Noise Barriers: Theory and Experiments
An easy-to-apply computational procedure for the study of the acoustic performance of pairs of diffusively reflecting roadside barriers is described in detail, and an experimental verification of its predictions, carried out on a 1:10 scale model, is presented and discussed. It is shown that, in comparison with pairs of more traditional specularly reflecting noise barriers, significant attenuation benefits are obtained not only in the shadow zone behind the barriers, but also in the unprotected zone immediately above the barriers, which proves that diffusive traffic faces of the barriers may effectively help in counteracting multiple reflection effects.
- 27 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (5) , 052501
Correlating Equations for Laminar Free Convection From Misaligned Horizontal Cylinders in Interacting Flow Fields
Steady laminar free convection in air from a pair of misaligned, parallel horizontal cylinders, i.e., a pair of parallel cylinders with their axes set in a plane inclined with respect to the gravity vector, is studied numerically. A specifically developed computer code based on the SIMPLE-C algorithm is used for the solution of the dimensionless mass, momentum, and energy transfer governing equations. Results are presented for different values of the center-to-center cylinder spacing from 1.4 up to 10 diameters, the tilting angle of the two-cylinder array from 0degto90deg, and the Rayleigh number based on the cylinder diameter in the range between 103 and 107. It is found that the heat transfer rates at both cylinder surfaces may in principle be traced back to the combined contributions of the so-called plume effect and chimney effect, which are the mutual interactions occurring in the vertical and horizontal alignments, respectively. In addition, at any misalignment angle, an optimum spacing between the cylinders for the maximum heat transfer rate, which decreases with increasing the Rayleigh number, does exist. Heat transfer dimensionless correlating equations are proposed for any individual cylinder and for the pair of cylinders as a whole.
- 27 March 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (5) , 052501
Correlating Equations for Laminar Free Convection From Misaligned Horizontal Cylinders in Interacting Flow Fields
Steady laminar free convection in air from a pair of misaligned, parallel horizontal cylinders, i.e., a pair of parallel cylinders with their axes set in a plane inclined with respect to the gravity vector, is studied numerically. A specifically developed computer code based on the SIMPLE-C algorithm is used for the solution of the dimensionless mass, momentum, and energy transfer governing equations. Results are presented for different values of the center-to-center cylinder spacing from 1.4 up to 10 diameters, the tilting angle of the two-cylinder array from 0degto90deg, and the Rayleigh number based on the cylinder diameter in the range between 103 and 107. It is found that the heat transfer rates at both cylinder surfaces may in principle be traced back to the combined contributions of the so-called plume effect and chimney effect, which are the mutual interactions occurring in the vertical and horizontal alignments, respectively. In addition, at any misalignment angle, an optimum spacing between the cylinders for the maximum heat transfer rate, which decreases with increasing the Rayleigh number, does exist. Heat transfer dimensionless correlating equations are proposed for any individual cylinder and for the pair of cylinders as a whole.
- Open Access
- 7 December 2007
- Published by International Information and Engineering Technology Association in International Journal of Sustainable Development and Planning
- Vol. 2 (4) , 490-509
A comparative study of the cooling performance of new HVAC systems based on the reversed air cycle
A numerical study on the cooling performance of new air-conditioning systems based on the reversed air cycle is conducted through a specifi cally...
- 7 December 2007
- Published by International Information and Engineering Technology Association in International Journal of Sustainable Development and Planning
- Vol. 2 (4) , 490-509
Open AccessA comparative study of the cooling performance of new HVAC systems based on the reversed air cycle
A numerical study on the cooling performance of new air-conditioning systems based on the reversed air cycle is conducted through a specifi cally...
- 1 November 2007
- Published by Elsevier in Applied Acoustics
- Vol. 68 (11-12) , 1357-1372
Experimental verification of the acoustic performance of diffusive roadside noise barriers
- 1 November 2007
- Published by Elsevier in Applied Acoustics
- Vol. 68 (11-12) , 1357-1372
Experimental verification of the acoustic performance of diffusive roadside noise barriers