Yun Wen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yun Wen has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Jinrong Li
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Sun Yat-Sen University, Guangzhou, China
4 shared publications Junpeng Yuan
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China
3 shared publicationsLei Feng
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China
3 shared publicationsQingqing Ye
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China
3 shared publicationsYing Yao
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China
3 shared publicationsYunsi He
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China
3 shared publications
Latest Publications
- Open Access
- 20 November 2025
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 13 (1) , e81082
A Novel Eye Tracking–Based Gamified Assessment of Contrast Sensitivity Function in Children: Prospective Development and Reliability Study
Background: Reliable assessment of visual function in young children remains a challenge. Contrast sensitivity function (CSF) is a sensitive and fundamental index of visual performance, yet existing pediatric CSF assessments lack objectivity and adaptability. To bridge this methodological gap, we developed a novel eye tracking–based gamified contrast sensitivity function (ETGCSF) tool that integrates gaze-based detection with interactive gameplay to objectively quantify CSF in an engaging and child-centered manner. Objective: This study aimed to (1) establish the feasibility and test-retest reliability of the ETGCSF tool in preschool-aged children and (2) evaluate whether optimization using adaptive algorithms and enhanced gamification elements could improve test efficiency while maintaining reliability. Methods: This was a prospective study with 2 sequential cohorts. A total of 80 Chinese children aged 3 to 6 years were pragmatically recruited from Zhongshan Ophthalmic Center between May 2021 and July 2023. On the basis of timing of data collection, 35% (28/80) of the children were included in experiment 1 (mean age 5.24, SD 0.15 years), and 65% (52/80) were included in experiment 2 (mean age 4.76, SD 0.11 years). Children completed 2 runs of ETGCSF test. Experiment 1 used the baseline ETGCSF protocol, and experiment 2 used the optimized protocol. Primary outcomes were test-retest reliability of the area under the log contrast sensitivity function curve (AULCSF) and CSF acuity, reported as intraclass correlation coefficients (ICCs) with 95% CIs. Results: In experiment 1, the ETGCSF tool showed strong reliability, with ICCs of 0.890 (95% CI 0.741‐0.951) for AULCSF and 0.890 (95% CI 0.763‐0.949) for CSF acuity. The median test duration was 482 (IQR 451‐569) seconds. In experiment 2, the optimized ETGCSF reduced median test duration to 241 (IQR 189‐296) seconds ( P <.001) while maintaining comparable reliability. AULCSF estimates varied by 0.03 log units across 2 runs (95% CI −0.51 to 0.57; t 51 =0.749; P =.46), with an ICC of 0.851 (95% CI 0.740‐0.914; P <.001) that was not significantly different from that of experiment 1 ( z =0.660; P =.51). Similarly, CSF acuity estimates varied by 0.004 log units (95% CI –0.33 to 0.32; t 51 =0.192; P =.85), with an ICC of 0.832 (95% CI 0.708‐0.904; P <.001), also comparable to that of experiment 1 ( z =–0.925; P =.36). Conclusions: This study introduces a paradigm shift in pediatric visual assessment by leveraging objective eye tracking and gamified engagement to transform contrast sensitivity testing into a scalable, child-friendly process. The ETGCSF tool demonstrated strong reliability and markedly improved efficiency in assessing CSF in preschool children aged 3 to 6 years. These findings support ETGCSF as a promising tool for real-world clinical practice, and its modular design holds potential for future adaptations ranging from streamlined rapid screening in very young children to full CSF profiling for research.
- 20 November 2025
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 13 (1) , e81082
Open AccessA Novel Eye Tracking–Based Gamified Assessment of Contrast Sensitivity Function in Children: Prospective Development and Reliability Study
Background: Reliable assessment of visual function in young children remains a challenge. Contrast sensitivity function (CSF) is a sensitive and fundamental index of visual performance, yet existing pediatric CSF assessments lack objectivity and adaptability. To bridge this methodological gap, we developed a novel eye tracking–based gamified contrast sensitivity function (ETGCSF) tool that integrates gaze-based detection with interactive gameplay to objectively quantify CSF in an engaging and child-centered manner. Objective: This study aimed to (1) establish the feasibility and test-retest reliability of the ETGCSF tool in preschool-aged children and (2) evaluate whether optimization using adaptive algorithms and enhanced gamification elements could improve test efficiency while maintaining reliability. Methods: This was a prospective study with 2 sequential cohorts. A total of 80 Chinese children aged 3 to 6 years were pragmatically recruited from Zhongshan Ophthalmic Center between May 2021 and July 2023. On the basis of timing of data collection, 35% (28/80) of the children were included in experiment 1 (mean age 5.24, SD 0.15 years), and 65% (52/80) were included in experiment 2 (mean age 4.76, SD 0.11 years). Children completed 2 runs of ETGCSF test. Experiment 1 used the baseline ETGCSF protocol, and experiment 2 used the optimized protocol. Primary outcomes were test-retest reliability of the area under the log contrast sensitivity function curve (AULCSF) and CSF acuity, reported as intraclass correlation coefficients (ICCs) with 95% CIs. Results: In experiment 1, the ETGCSF tool showed strong reliability, with ICCs of 0.890 (95% CI 0.741‐0.951) for AULCSF and 0.890 (95% CI 0.763‐0.949) for CSF acuity. The median test duration was 482 (IQR 451‐569) seconds. In experiment 2, the optimized ETGCSF reduced median test duration to 241 (IQR 189‐296) seconds ( P <.001) while maintaining comparable reliability. AULCSF estimates varied by 0.03 log units across 2 runs (95% CI −0.51 to 0.57; t 51 =0.749; P =.46), with an ICC of 0.851 (95% CI 0.740‐0.914; P <.001) that was not significantly different from that of experiment 1 ( z =0.660; P =.51). Similarly, CSF acuity estimates varied by 0.004 log units (95% CI –0.33 to 0.32; t 51 =0.192; P =.85), with an ICC of 0.832 (95% CI 0.708‐0.904; P <.001), also comparable to that of experiment 1 ( z =–0.925; P =.36). Conclusions: This study introduces a paradigm shift in pediatric visual assessment by leveraging objective eye tracking and gamified engagement to transform contrast sensitivity testing into a scalable, child-friendly process. The ETGCSF tool demonstrated strong reliability and markedly improved efficiency in assessing CSF in preschool children aged 3 to 6 years. These findings support ETGCSF as a promising tool for real-world clinical practice, and its modular design holds potential for future adaptations ranging from streamlined rapid screening in very young children to full CSF profiling for research.
- 5 July 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (10) , 2915-2926
Insertional anatomy of horizontal rectus extraocular muscles in patients with Esotropia and Exotropia
Purpose Strabismus, including esotropia and exotropia, significantly affects binocular vision and presents challenges in clinical management and surgical correction. Although previous studies have explored the anatomical characteristics of horizontal rectus extraocular muscles (EOMs) in strabismus, large-scale analyses of insertional anatomy remain limited. This study investigates anatomical variations in the insertions of horizontal rectus EOMs in patients with esotropia and exotropia, aiming to understand their impact on strabismus management. Methods A retrospective case-control study was conducted using clinical records from 4781 patients diagnosed with strabismus who underwent surgery at the Zhongshan Ophthalmic Center, Sun Yat-sen University, from June 2014 to August 2020. Anatomical measurements of horizontal rectus EOM insertions were taken using a Castroviejo caliper. Statistical analyses, including regression analysis, were performed to examine the relationship between EOM characteristics and clinical outcomes. Results Significant anatomical differences were observed among esotropia, exotropia, and control groups. Esotropia patients exhibited shorter medial rectus (MR) insertion distances (mean: 4.81 mm) than both exotropia (5.09 mm) and controls (5.08 mm, p < 0.001), with moderate effect sizes. Exotropia subtypes showed wider MR and lateral rectus (LR) insertions, particularly in constant and pattern types (MR width p = 0.001, LR width p = 0.002). Regression analysis indicated that shorter MR insertion distance was significantly associated with greater esodeviation at both near (β = -13.60, p < 0.001) and distance (β = -12.76, p < 0.001), though with small effect sizes. Refractive error (SE) and age were also significant predictors of deviation magnitude and AC/A ratio. Conclusion Anatomical variations in the horizontal rectus EOMs are significantly associated with esotropia and exotropia. These findings enhance our understanding of strabismus pathophysiology and may help guide surgical strategies for severe cases, though further research is needed to refine clinical applications.
- 5 July 2025
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 263 (10) , 2915-2926
Insertional anatomy of horizontal rectus extraocular muscles in patients with Esotropia and Exotropia
Purpose Strabismus, including esotropia and exotropia, significantly affects binocular vision and presents challenges in clinical management and surgical correction. Although previous studies have explored the anatomical characteristics of horizontal rectus extraocular muscles (EOMs) in strabismus, large-scale analyses of insertional anatomy remain limited. This study investigates anatomical variations in the insertions of horizontal rectus EOMs in patients with esotropia and exotropia, aiming to understand their impact on strabismus management. Methods A retrospective case-control study was conducted using clinical records from 4781 patients diagnosed with strabismus who underwent surgery at the Zhongshan Ophthalmic Center, Sun Yat-sen University, from June 2014 to August 2020. Anatomical measurements of horizontal rectus EOM insertions were taken using a Castroviejo caliper. Statistical analyses, including regression analysis, were performed to examine the relationship between EOM characteristics and clinical outcomes. Results Significant anatomical differences were observed among esotropia, exotropia, and control groups. Esotropia patients exhibited shorter medial rectus (MR) insertion distances (mean: 4.81 mm) than both exotropia (5.09 mm) and controls (5.08 mm, p < 0.001), with moderate effect sizes. Exotropia subtypes showed wider MR and lateral rectus (LR) insertions, particularly in constant and pattern types (MR width p = 0.001, LR width p = 0.002). Regression analysis indicated that shorter MR insertion distance was significantly associated with greater esodeviation at both near (β = -13.60, p < 0.001) and distance (β = -12.76, p < 0.001), though with small effect sizes. Refractive error (SE) and age were also significant predictors of deviation magnitude and AC/A ratio. Conclusion Anatomical variations in the horizontal rectus EOMs are significantly associated with esotropia and exotropia. These findings enhance our understanding of strabismus pathophysiology and may help guide surgical strategies for severe cases, though further research is needed to refine clinical applications.
- 13 January 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (6) , 661-670
Factual Evidence on Digital Therapeutics in Pediatric Amblyopia
- 13 January 2025
- Published by Elsevier in Ophthalmology
- Vol. 132 (6) , 661-670
Factual Evidence on Digital Therapeutics in Pediatric Amblyopia
- Open Access
Impact of COVID-19 pandemic control measures on amblyopia treatment: a retrospective study of records from a tertiary eye hospital in China
Objectives Amblyopia is the most common cause of unilateral visual impairment in children and requires long-term treatment. This study aimed to quantify the impact of pandemic control measures on amblyopia management. Design and setting This was a retrospective cohort study of data from a large amblyopia management database at a major tertiary eye care centre in China. Participants Outpatients with amblyopia who visited the hospital from 1 June 2019, through 28 February 2022. Primary and secondary outcome measures The primary outcome was the number of first and follow-up in-person visits to the hospital for amblyopia treatment. Secondary outcomes included the time interval between consecutive visits and improvement of vision (visual acuity, contrast sensitivity and stereopsis). Patient records were grouped into prepandemic and during pandemic periods. Results A total of 10 060 face-to-face visits for 5361 patients (median age 6.7 years, IQR 5.4, 8.9) that spanned two lockdown periods were included in the analysis, of which 28% were follow-up visits. Pandemic control measures caused a sharp decline in the number of outpatient visits (3% and 30% of prepandemic levels in the months directly after the start of the first (2020) and second (2021) periods of pandemic control measures, respectively). However, these drops were followed by pronounced rebounds in visits that exceeded prepandemic levels by 51.1% and 108.5%, respectively. The interval between consecutive visits increased significantly during the pandemic from a median (IQR) of 120 (112, 127) days in 2019 to 197 (179, 224) in 2020 (pConclusions The number of amblyopia patient hospital visits spiked well above prepandemic levels following lockdown periods. This pattern of patient behaviour can inform planning for amblyopia treatment services during and after public health-related disruptions.
Open AccessImpact of COVID-19 pandemic control measures on amblyopia treatment: a retrospective study of records from a tertiary eye hospital in China
Objectives Amblyopia is the most common cause of unilateral visual impairment in children and requires long-term treatment. This study aimed to quantify the impact of pandemic control measures on amblyopia management. Design and setting This was a retrospective cohort study of data from a large amblyopia management database at a major tertiary eye care centre in China. Participants Outpatients with amblyopia who visited the hospital from 1 June 2019, through 28 February 2022. Primary and secondary outcome measures The primary outcome was the number of first and follow-up in-person visits to the hospital for amblyopia treatment. Secondary outcomes included the time interval between consecutive visits and improvement of vision (visual acuity, contrast sensitivity and stereopsis). Patient records were grouped into prepandemic and during pandemic periods. Results A total of 10 060 face-to-face visits for 5361 patients (median age 6.7 years, IQR 5.4, 8.9) that spanned two lockdown periods were included in the analysis, of which 28% were follow-up visits. Pandemic control measures caused a sharp decline in the number of outpatient visits (3% and 30% of prepandemic levels in the months directly after the start of the first (2020) and second (2021) periods of pandemic control measures, respectively). However, these drops were followed by pronounced rebounds in visits that exceeded prepandemic levels by 51.1% and 108.5%, respectively. The interval between consecutive visits increased significantly during the pandemic from a median (IQR) of 120 (112, 127) days in 2019 to 197 (179, 224) in 2020 (pConclusions The number of amblyopia patient hospital visits spiked well above prepandemic levels following lockdown periods. This pattern of patient behaviour can inform planning for amblyopia treatment services during and after public health-related disruptions.
- 24 May 2021
- Published by BMJ in British Journal of Ophthalmology
- Vol. 106 (11) , 1530-1537
Higher contrast thresholds for vanishing optotype recognition in macular visual fields among glaucoma patients: a structure–function analysis
Background/aims We aimed to explore the impact of glaucomatous macular damage, specifically retinal ganglion cell (RGC) loss, on macular pattern vision measured by the vanishing optotype (VO) recognition contrast threshold. Methods Seventy-two patients (mean age, 33.51±7.05 years) with primary open-angle glaucoma and 36 healthy controls (mean age, 30.25±6.70 years) were enrolled. VO recognition contrast thresholds of each participant were measured at the 16 preset test locations covering the central 5° visual field (VF). Macular sensitivity (MS) was tested by macular threshold test of Humphrey Field Analyzer. Macular RGC plus inner plexiform layer (GCIPL) thickness was also measured by spectral domain optical coherence tomography. Results The VO contrast threshold demonstrated weak-to-moderate correlations (rho=−0.275 to −0.653) with MS (pConclusions Glaucomatous eyes have higher contrast thresholds for VO recognition in fovea-around VF. Stronger structure–function relationships indicate that VO contrast threshold is more vulnerable to RGC damage.
- 24 May 2021
- Published by BMJ in British Journal of Ophthalmology
- Vol. 106 (11) , 1530-1537
Higher contrast thresholds for vanishing optotype recognition in macular visual fields among glaucoma patients: a structure–function analysis
Background/aims We aimed to explore the impact of glaucomatous macular damage, specifically retinal ganglion cell (RGC) loss, on macular pattern vision measured by the vanishing optotype (VO) recognition contrast threshold. Methods Seventy-two patients (mean age, 33.51±7.05 years) with primary open-angle glaucoma and 36 healthy controls (mean age, 30.25±6.70 years) were enrolled. VO recognition contrast thresholds of each participant were measured at the 16 preset test locations covering the central 5° visual field (VF). Macular sensitivity (MS) was tested by macular threshold test of Humphrey Field Analyzer. Macular RGC plus inner plexiform layer (GCIPL) thickness was also measured by spectral domain optical coherence tomography. Results The VO contrast threshold demonstrated weak-to-moderate correlations (rho=−0.275 to −0.653) with MS (pConclusions Glaucomatous eyes have higher contrast thresholds for VO recognition in fovea-around VF. Stronger structure–function relationships indicate that VO contrast threshold is more vulnerable to RGC damage.
- 21 November 2019
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 258 (3) , 675-682
Topographical profiles of macula and optic nerve head in concomitant strabismus patients as measured using OCT and CSLO
Investigate morphological changes of macula and optic nerve head (ONH) in concomitant strabismic patients using optical coherence tomography (OCT) and confocal scanning laser ophthalmoscopy (CSLO).
- 21 November 2019
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 258 (3) , 675-682
Topographical profiles of macula and optic nerve head in concomitant strabismus patients as measured using OCT and CSLO
Investigate morphological changes of macula and optic nerve head (ONH) in concomitant strabismic patients using optical coherence tomography (OCT) and confocal scanning laser ophthalmoscopy (CSLO).