FQFabio Quartieri

Fabio Quartieri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabio Quartieri has a total of 96 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Continuing evaluation of atrial fibrillation detection after cryptogenic stroke: 2-year findings from a multicentre study with Confirm Rx ICM

    by Fabio Quartieri, Yong-Soo Baek, Jong-Sung Park, Tae-Hoon Kim, Kazunari Honma, Masafumi Morimoto, Ki-Woon Kang, Lin Feng, Kwangdeok Lee, Andrea Grammatico, et al.

    Background: The detection of atrial fibrillation (AF) after a cryptogenic stroke (CS) carries important therapeutic implications. In this study, we aimed to accurately assess the incidence of AF among CS subjects by using an insertable cardiac monitor (ICM). Methods: A prospective, single-arm, multicentre registry was conducted to identify AF in 155 CS subjects using the Confirm Rx ICM (Abbott, California, USA) across 20 global sites. Inclusion criteria comprised participants aged 40 years or older who had experienced CS within a 90-day window. At each follow-up visit, expert electrophysiologists reviewed and adjudicated ICM detected AF episodes. The primary endpoint was the cumulative incidence of true device-detected AF (lasting more than 30 s) at 6 months, evaluated with Kaplan-Meier methods. Results: AF incidence was 21.3% (95% CI 15.3% to 29.1%) at 6 months, increasing to 48.8% (95% CI 34.7% to 64.9%) at 24 months. Subjects with AF detection experienced an average of 50.9 true AF episodes per subject per year. The median time from implantation to AF detection (>30 s) was 72 days (IQR 7–261). Among subjects with 30 s AF detection, anticoagulation therapy was initiated in 65.2% (30/46) of subjects. Oral anticoagulation medication was prescribed in 8.3% (9/109) of subjects without AF. Recurrent ischaemic stroke or transient ischaemic attack occurred in 5 subjects (3.2%, 5/155). Conclusion: These results show that ICM-driven long-term continuous AF monitoring is associated with high diagnostic yield in CS subjects. Trial registration number: NCT03505801


  • How to assess fitness to drive in patients with cardiac rhythm disturbances through an applicable decision support system

    by Monia Lusetti, Antonia Nini, Matteo Iori, Antonella Battista, Nicola Bottoni, Fabio Quartieri


  • Artificial intelligence cloud platform improves arrhythmia detection from insertable cardiac monitors to 25 cardiac rhythm patterns through multi-label classification

    by Fabio Quartieri, Manuel Marina-Breysse, Raquel Toribio-Fernandez, Carlos Lizcano, Annalisa Pollastrelli, Isabella Paini, Roberto Cruz, Andrea Grammatico, José María Lillo-Castellano


  • Open Access

    Ability to remotely monitor atrial high-rate episodes using a single-chamber implantable cardioverter-defibrillator with a floating atrial sensing dipole

    by Gerhard Hindricks, Dominic A Theuns, David Bar-Lev, Ignasi Anguera, Félix Alejandro Ayala Paredes, Martin Arnold, J Christoph Geller, Béla Merkely, Katia Marjolaine Dyrda, Christian Perings, et al.

    To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


  • Open Access

    New insertable cardiac monitors show high diagnostic yield and good safety profile in real-world clinical practice: results from the international prospective observational SMART Registry

    by Fabio Quartieri, Manyam Harish, Leonardo Calò, Iftikhar Ebrahim, Antonio Fusco, Stephen Mester, Filippo Cauti, Seung-Jung Park, Pietro Francia, Marco Giovagnoni, et al.

    Insertable cardiac monitors (ICMs) are indicated for long-term monitoring of unexplained syncope or palpitations, and for detection of bradycardia, ventricular tachycardia, and/or atrial fibrillation (AF). The aim of our study was to evaluate the safety and clinical value associated with a new generation ICM (Confirm Rx™, Abbott, Illinois, USA), featuring a new remote monitoring system based on smartphone patient applications. The SMART Registry is an international prospective observational study. The main endpoints were ICM safety (incidence of serious adverse device and procedure-related events (SADEs) at 1 month), ICM clinical value (incidence of device-detected true arrhythmias and of clinical diagnoses and interventions), and patient-reported experience measurements (PREMs). A total of 1400 subjects were enrolled. ICM indications included syncope (49.1%), AF (18.8%), unexplained palpitations (13.6%), risk of ventricular arrhythmia (6.6%), and cryptogenic stroke (6.0%). Freedom from SADEs at 1 month was 99.4% (95% Confidence Interval: 98.8–99.7%). In the 6-month monitoring period, the ICM detected true cardiac arrhythmias in 45.7% of patients and led to clinical interventions in a relevant proportion of patients; in particular, a pacemaker implant was performed after bradycardia detection in 8.9% of subjects who received an ICM for syncope and oral anticoagulation therapy was indicated after AF detection in 15.7% of subjects with cryptogenic stroke. PREMs showed that 78.2% of subjects were satisfied with the remote monitoring patient app. The evaluated ICM is associated with an excellent safety profile and high diagnostic yield. Patients reported positive experiences associated with the use of their smartphone for the device remote monitoring.


  • Open Access

    Twenty-year experience of atrial fibrillation ablation: a single-centre cohort study

    by Nicola Bottoni, Fabio Quartieri, Matteo Iori, Antonella Battista, Alessandro Navazio, Michele Brignole

    Aims: While several studies in the literature have reported results of catheter ablation of AF, few is known regarding outcome for more than 10 years. Methods and results: The complete population of patients who underwent AF ablation in the years 2002–2021 in the department of cardiology of the hospital of Reggio Emilia has been analysed. The last follow-up was made in the second half of 2022. During this period the technique of ablation remained relatively unchanged as well the physicians performing ablation. Primary endpoint was the recurrence of symptomatic AF, defined as AF that caused symptoms that were defined by the patient as able to alter their quality of life. 669 patients underwent catheter ablation and 618 were followed until 2022. Median age of the patients was 58 ± 9 years and 521 (78%) were male. There were 407 (61%) of patients with paroxysmal AF, 167 (25%) with persistent AF and 95 (14%) with long-lasting AF. A total of 838 procedures were performed, with a mean of 1.25 per patient. 163 (26%) patients had 2 procedures and 6 had 3 ablations. Periprocedural complications occurred in 4.8% of procedures. Follow-up data were available for 618 patients (92.4%). The median follow-up duration was 6.6 years (IQR 3.2–10.8). The estimated recurrence rate of symptomatic AF was 26% at 10 years, 54% at 15 years and 82% at 20 years. The recurrence rate was similar in patients who had performed one procedure and in those who had performed 2 or 3 procedures. Progression to permanent AF occurred in 112 patients (18%). The major events that occurred during the follow-up consisted of total mortality in 4.5%, heart failure in 3.1% and TIA/stroke in 2.4%. Conclusion: Symptomatic AF tends to recur during long-term follow-up despite one or more procedures. Catheter ablation seems able to reduce the rate of symptomatic recurrences and to delay the time of their occurrence. These findings are consistent with the knowledge that an age-dependent progressive structural atriomiopathy is the basis for the development of AF.


  • Open Access

    Impact of Systematic Use of Intracardiac Ultrasound during Transseptal Catheterization in the Electrophysiology Laboratory

    by Nicola Bottoni, Paolo Donateo, Luca Rossi, Michele Malagù, Luca Tomasi, Fabio Quartieri, Andrea Biagi, Matteo Iori, Giacomo Mugnai, Antonella Battista, et al.

    Aims: To explore the impact of the use of intracardiac echocardiography (ICE) in the ablation of supraventricular arrhythmias requiring transseptal catheterization (TSC), whilst analyzing the reduction in periprocedural complications and complications specifically related to TSC. Methods: A retrospective multicenter study collecting data from consecutive atrial fibrillation (AF) and supraventricular ablation procedures that required TSC was performed in five Italian centers. Based on physician discretion, TSC was performed with or without ICE. Periprocedural complications, separating all complications from complications directly related to TSC, were collected. Independent predictors of periprocedural complications and TSC-related complications were investigated. Results: A total of 2181 TSCs were performed on 1862 patients at five Italian centers from 2006 to 2021, in 76% of cases by AF ablation and in 24% by ablation of other arrhythmias with a circuit in the left atrium. Overall, 1134 (52%) procedures were performed with ICE support and 1047 (48%) without ICE. A total of 67 (3.1%) complications were detected, 19 (1.7%) in the ICE group and 48 (4.6%) in the no ICE group, p < 0.001. A total of 42 (1.5%) complications directly related to TSC: 0.9% in the ICE group and 3.1% in the no ICE group (p < 0.001). The independent predictors of all complications were age (OR 1,02 95% C.I 1.00–1.05; p = 0.036), TSC with the use of ICE (OR 0.27 95% C.I 0.15–0.46; p < 0.001) and AF ablation (OR 2,25 95%C.I 1.05–4.83; p = 0.037). The independent predictors for TSC complications were age (OR 1.03 95% C.I 1.01–1.06; p = 0.013) and TSC with the use of ICE (OR 0.24 95% C.I 0.11–0.49; p < 0.001). Conclusions: ICE reduced periprocedural and TSC-related complications during electrophysiological procedures for ablation of left atrial arrhythmias.


  • Implantable cardioverter defibrillator lead performance: A systematic review and individual patient data Meta-analysis

    by Daniele Giacopelli, Danila Azzolina, Rosanna Irene Comoretto, Fabio Quartieri, Giovanni Rovaris, Vincenzo Schillaci, Alessio Gargaro, Dario Gregori


  • Open Access

    Artificial intelligence augments detection accuracy of cardiac insertable cardiac monitors: Results from a pilot prospective observational study

    by Fabio Quartieri, Manuel Marina-Breysse, Annalisa Pollastrelli, Isabella Paini, Carlos Lizcano, José María Lillo-Castellano, Andrea Grammatico


  • Open Access

    Vascular Accesses in Cardiac Stimulation and Electrophysiology: An Italian Survey Promoted by AIAC (Italian Association of Arrhythmias and Cardiac Pacing)

    by Matteo Ziacchi, Angelo Placci, Andrea Angeletti, Fabio Quartieri, Cristina Balla, Santo Virzi, Matteo Bertini, Roberto De Ponti, Mauro Biffi, Giuseppe Boriani, et al.

    Cardiac implantable electronic device (CIED) implants and electrophysiological procedures share a common step: vascular access. On behalf of the AIAC Ricerca Investigators’ Network, we conducted a survey to outline Italian common practice regarding vascular access in EP-lab. All Italian physicians with experience in CIED implantation and electrophysiology were invited to answer an online questionnaire (from May 2020 to November 2020) featuring 20 questions. In total, 103 cardiologists (from 92 Italian hospitals) answered the survey. Vascular access during CIED implants was considered the most complex step following lead placement by 54 (52.4%) respondents and the most complex for 35 (33.9%). In total, 54 (52.4%) and 49 (47.6%) respondents considered the cephalic and subclavian vein the first option, respectively (intrathoracic and extrathoracic subclavian/axillary vein by 22 and 27, respectively). In total, 45 (43.7%) respondents performed close arterial femoral accesses manually; only 12 (11.7%) respondents made extensive use of vascular closure devices. A total of 46 out of 103 respondents had experience in ultrasound-guided vascular accesses, but only 10 (22%) used it for more than 50% of the accesses. In total, 81 (78.6%) respondents wanted to increase their ultrasound-guided vascular access skills. Reducing complications is a goal to reach in cardiac stimulation and electrophysiological procedures. Our survey shows the heterogeneity of the vascular approaches used in Italian centres. Some vascular accesses were proved to be superior to others in terms of complications, with ultrasound-guided puncture as an emerging technique. More effort to produce the standardization of vascular accesses could be made by scientific societies.