Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nantana Nuchtavorn has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Selective extraction of pentacyclic triterpenoids from Centella asiatica using aprotic ionic liquid-assisted techniques

    by Nantana Nuchtavorn, Jiraporn Leanpolchareanchai, Jakaphun Julsrigival, Nararat Akarchariya


  • Open Access

    Distance-based paper microfluidic devices for rapid visual quantification of heavy metals in herbal supplements and cosmetics

    by Yanawut Manmana, Mirek Macka, Nantana Nuchtavorn

    Distance-based detection (DbD) on paper-based microfluidic analytical devices (μPADs) has emerged as a promising, cost-effective, simple, and instrumentation-free assay method. Broadening the applicability of a new way of immobilization of reagent for DbD on μPADs (DμPADs) is presented, employing an ion exchange (IE) interaction of an anionic metallochromic reagent, 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol (5-Br-PAPS), on the anion-exchange filter paper. The IE DμPADs demonstrate superiority over standard cellulose filter paper in terms of the degree of reagent immobilization, detection sensitivity, and clear detection endpoints due to the strong retention of 5-Br-PAPS. The study investigated various parameters influencing DbD, including 5-Br-PAPS concentrations (0.25–1 mM), buffer types (acetic acid–Tris, MES), buffer concentrations (20–500 mM), and auxiliary complexing agents (acetic, formic, and glycolic acids). Subsequently, the performance of 17 metals (Ag+, Cd2+, Co2+, Cr3+, Cu2+, Fe2+, Hg2+, La2+, Mn2+, Ni2+, Pb2+, Ti2+, Zn2+, Al3+, As3+, Fe3+, and V4+) was evaluated, with color formation observed for 12 metals. Additionally, the paper surface was examined using SEM and SEM-EDX to verify the suitability of certain areas in the detection channel for reagent immobilization and metal binding. This method demonstrates quantitation limits of metals in the low μg mL−1 range, showing great potential for the rapid screening of toxic metals commonly found in herbal supplements and cosmetics regulated by the Food and Drug Administration (FDA). Thus, it holds promise for enhancing safety and regulatory compliance in product quality assessment. Furthermore, this method offers a cost-effective, environmentally sustainable, and user-friendly approach for the rapid visual quantification of heavy metals for in-field analysis, eliminating the need for complex instrumentation.


  • Open Access

    Development of Miconazole-Loaded Microemulsions for Enhanced Topical Delivery and Non-Destructive Analysis by Near-Infrared Spectroscopy

    by Chutima Phechkrajang, Wichuda Phiphitphibunsuk, Rapee Sukthongchaikool, Nantana Nuchtavorn, Jiraporn Leanpolchareanchai

    The antifungal drug miconazole nitrate has a low solubility in water, leading to reduced therapeutic efficacy. To address this limitation, miconazole-loaded microemulsions were developed and assessed for topical skin delivery, prepared through spontaneous emulsification with oleic acid and water. The surfactant phase included a mixture of polyoxyethylene sorbitan monooleate (PSM) and various cosurfactants (ethanol, 2-(2-ethoxyethoxy) ethanol, or 2-propanol). The optimal miconazole-loaded microemulsion containing PSM and ethanol at a ratio of 1:1 showed a mean cumulative drug permeation of 87.6 ± 5.8 μg/cm2 across pig skin. The formulation exhibited higher cumulative permeation, permeation flux, and drug deposition than conventional cream and significantly increased the in vitro inhibition of Candida albicans compared with cream (p < 0.05). Over the course of a 3-month study conducted at a temperature of 30 ± 2 °C, the microemulsion exhibited favorable physicochemical stability. This outcome signifies its potential suitability as a carrier for effectively administering miconazole through topical administration. Additionally, a non-destructive technique employing near-infrared spectroscopy coupled with a partial least-squares regression (PLSR) model was developed to quantitatively analyze microemulsions containing miconazole nitrate. This approach eliminates the need for sample preparation. The optimal PLSR model was derived by utilizing orthogonal signal correction pretreated data with one latent factor. This model exhibited a remarkable R2 value of 0.9919 and a root mean square error of calibration of 0.0488. Consequently, this methodology holds potential for effectively monitoring the quantity of miconazole nitrate in various formulations, including both conventional and innovative ones.


  • Open Access

    Optimization of Magnetic and Paper-Based Molecularly Imprinted Polymers for Selective Extraction of Charantin in Momordica charantia

    by Nantana Nuchtavorn, Jiraporn Leanpolchareanchai, Satsawat Visansirikul, Somnuk Bunsupa

    Charantin is a mixture of β-sitosterol and stigmastadienol glucosides, which effectively lowers high blood glucose. Novel molecularly imprinted polymers coated magnetic nanoparticles (Fe3O4@MIPs) and filter paper (paper@MIPs) were synthesized by sol-gel polymerization to selectively extract charantin. β-sitosterol glucoside was selected as a template for imprinting a specific recognition owing to its larger molecular surface area than that of 5,25-stigmastadienol glucoside. Factorial designs were used to examine the effects of the types of porogenic solvents and cross-linkers on the extraction efficiency and imprinting factor before investigating other factors (for example, amounts of template and coated MIPs, and types of substrates for MIP immobilization). Compared to traditional liquid–liquid extraction, the optimal Fe3O4@MIP-based dispersive micro-solid phase extraction and paper@MIP extraction provided excellent extraction efficiency (87.5 ± 2.1% and 85.0 ± 2.9%, respectively) and selectivity. Charantin was well separated, and a new unidentified sterol glucoside was observed using the developed high-performance liquid chromatography with diode-array detection (Rs ≥ 2.0, n > 16,400). The developed methods were successfully utilized to extract and quantify charantin from M. charantia fruit powder and herbal products. Moreover, these methods are rapid (<10 min), inexpensive, simple, reproducible, and environmentally friendly.


  • Open Access

    Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools

    by Jiraporn Leanpolchareanchai, Nantana Nuchtavorn

    Microneedles (MNs) have shown a great potential for the microsampling of dermal interstitial fluid (ISF) in a minimally invasive manner for point-of-care testing (POCT). The swelling properties of hydrogel-forming microneedles (MNs) allow for passive extraction of ISF. Surface response approaches, including Box-Behnken design (BBD), central composite design (CCD), and optimal discrete design, were employed for the optimization of hydrogel film by studying the effects of independent variables (i.e., the amount of hyaluronic acid, GantrezTM S-97, and pectin) on the swelling property. The optimal discrete model was selected to predict the appropriate variables, due to the good fit of the experimental data and the model validity. The analysis of variance (ANOVA) of the model demonstrated p-value < 0.0001, R2 = 0.9923, adjusted R2 = 0.9894, and predicted R2 = 0.9831. Finally, the predicted film formulation containing 2.75% w/w hyaluronic acid, 1.321% w/w GantrezTM S-97, and 1.246% w/w pectin was used for further fabrication of MNs (525.4 ± 3.8 µm height and 157.4 ± 2.0 µm base width), which possessed 1508.2 ± 66.2% swelling, with 124.6 ± 7.4 µL of collection volume, and could withstand thumb pressure. Moreover, almost 50% of MNs achieved a skin insertion depth of approx. 400 µm, with 71.8 ± 3.2% to 78.3 ± 2.6% recoveries. The developed MNs show a promising prospect in microsample collection, which would be beneficial for POCT.


  • Open Access

    A Comparative Study of Benchtop and Portable NIR and Raman Spectroscopic Methods for the Quantitative Determination of Curcuminoids in Turmeric Powder

    by Putthiporn Khongkaew, Jordi Cruz, Judit Puig Bertotto, Vanessa Cárdenas, Manel Alcalà, Nantana Nuchtavorn, Chutima Phechkrajang

    Turmeric consumption is continually increasing worldwide. Curcuminoids are major active constituents in turmeric and are associated with numerous health benefits. A combination of spectroscopic methods and chemometrics shows the suitability of turmeric for food quality control due to advantages such as speed, versatility, portability, and no need for sample preparation. Five calibration models to quantify curcuminoids in turmeric were proposed using benchtop and portable devices. The most remarkable results showed that Raman and NIR calibration models present an excellent performance reporting RMSEP of 0.44% w/w and 0.41% w/w, respectively. In addition, the five proposed methods (FT-IR, Raman, and NIR) were compared in terms of precision and accuracy. The results showed that benchtop and portable methods were in good agreement and that there are no significant differences between them. This study aims to foster the use of portable devices for food quality control in situ by demonstrating their suitability for the purpose.


  • A Rapid Stability Indicating HPLC Method for Determination of Quetiapine Fumarate in Tablets and Extemporaneous Formulations

    by Nantana Nuchtavorn, Jiraporn Leanpolchareanchai, Duangjai Chanton, Patcharin Supapsophon, Sumet Chongruchiroj, Jidapa Chatmapanrangsee, Jiraphong Suksiriworapong