Mohammad Kazem Amini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Kazem Amini has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Masoud Bakhshi
Sooreh Company
2 shared publications Ali R. Firooz
Chemistry Department, University of Isfahan, Isfahan, Iran
1 shared publicationAli Souri
Sooreh Company
1 shared publication- Bahareh Khezri
Inorganic and Physical Chemistry Department Universitat Rovira i Virgili Tarragona Tarragona Spain
1 shared publication - Esmaeil Shams
University of Isfahan
1 shared publication H. Rashidi Nassab
Sooreh Company, Isfahan, Iran
1 shared publication
Latest Publications
- 2 February 2019
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 16 (6) , 1265-1272
Carbothermic synthesis of boron carbide with low free carbon using catalytic amount of magnesium chloride
- 2 February 2019
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 16 (6) , 1265-1272
Carbothermic synthesis of boron carbide with low free carbon using catalytic amount of magnesium chloride
- 10 June 2016
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 13 (9) , 1673-1681
Comparison of sample preparation methods for determination of free carbon in boron carbide by X-ray powder diffraction
- 10 June 2016
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 13 (9) , 1673-1681
Comparison of sample preparation methods for determination of free carbon in boron carbide by X-ray powder diffraction
- 11 June 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (7) , 1598-1605
Adsorptive Cathodic Stripping Voltammetric Determination of Uranium(VI) in Presence of N‐Phenylanthranilic Acid
N‐Phenylanthranilic acid was used as a complexing agent for determination of uranium(VI) by adsorptive cathodic stripping voltammetry. Under the optimal experimental conditions of the experimental parameters, the peak current was proportional to the concentration of U(VI) in the range 0.75–30 ng mL−1 and the detection limit was 0.036 ng mL−1. The influence of possible interferences was investigated. The method was applied for determination of uranium in waste water from uranium conversion facility and natural water samples. Application of the method for simultaneous determination of U(VI) and Cu(II) showed that these ions could be simultaneously determined in a single scan at relatively wide concentration range.
- 11 June 2014
- Published by Wiley in Electroanalysis
- Vol. 26 (7) , 1598-1605
Adsorptive Cathodic Stripping Voltammetric Determination of Uranium(VI) in Presence of N‐Phenylanthranilic Acid
N‐Phenylanthranilic acid was used as a complexing agent for determination of uranium(VI) by adsorptive cathodic stripping voltammetry. Under the optimal experimental conditions of the experimental parameters, the peak current was proportional to the concentration of U(VI) in the range 0.75–30 ng mL−1 and the detection limit was 0.036 ng mL−1. The influence of possible interferences was investigated. The method was applied for determination of uranium in waste water from uranium conversion facility and natural water samples. Application of the method for simultaneous determination of U(VI) and Cu(II) showed that these ions could be simultaneously determined in a single scan at relatively wide concentration range.
- 18 April 2014
- Published by Taylor & Francis in Petroleum Science and Technology
- Vol. 32 (13) , 1537-1544
Ionic Liquid-based Extraction of Sulfur Compounds From Gasoline as a Complementary Process to Oxidative Desulfurization
The extractive desulfurization of a model and several real gasoline samples was investigated using imidazolium-based ionic liquids (ILs). Factorial design of experiments indicated that, among several process variables, the number of extraction steps and the IL/gasoline volume ratio were statistically highly significant. The results showed a desulfurization efficiency of 95.2% under the optimal conditions. The following order was observed for the extraction of thiophenic compounds: benzothiophene>thiophene>3-methylthiophene>2-methylthiophene, with 96.1% removal efficiency for the first one. The IL extraction was applied as a complementary process for the oxidative desulfurization by hydrogen peroxide and formic acid, which provided high efficiency and selectivity for desulfurization of gasoline.
- 18 April 2014
- Published by Taylor & Francis in Petroleum Science and Technology
- Vol. 32 (13) , 1537-1544
Ionic Liquid-based Extraction of Sulfur Compounds From Gasoline as a Complementary Process to Oxidative Desulfurization
The extractive desulfurization of a model and several real gasoline samples was investigated using imidazolium-based ionic liquids (ILs). Factorial design of experiments indicated that, among several process variables, the number of extraction steps and the IL/gasoline volume ratio were statistically highly significant. The results showed a desulfurization efficiency of 95.2% under the optimal conditions. The following order was observed for the extraction of thiophenic compounds: benzothiophene>thiophene>3-methylthiophene>2-methylthiophene, with 96.1% removal efficiency for the first one. The IL extraction was applied as a complementary process for the oxidative desulfurization by hydrogen peroxide and formic acid, which provided high efficiency and selectivity for desulfurization of gasoline.
- 29 February 2012
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 9 (5) , 715-722
Preparation of CoSe nanoparticles by microwave-assisted polyol method: effect of Se/Co ratio, support type and synthesis conditions on oxygen reduction activity
- 29 February 2012
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 9 (5) , 715-722
Preparation of CoSe nanoparticles by microwave-assisted polyol method: effect of Se/Co ratio, support type and synthesis conditions on oxygen reduction activity
- Open Access
- 1 January 2011
- Published by Wiley in International Journal of Electrochemistry
- Vol. 2011 (1) , 1-13
Effect of Elemental Composition on the Structure, Electrochemical Properties, and Ozone Production Activity of Ti/Sn-Sb-Ni Electrodes Prepared by Thermal Pyrolysis MethodTi/SnO2-Sb-Ni electrodes with various Ni- and Sb-doping levels have been prepared by dip-coating thermal pyrolysis procedure, and their simultaneous electrochemical ozone production (EOP) and oxygen evolution reaction (OER) were investigated. The effects of electrode composition on the nanostructure, morphology, electrochemical behavior, kinetic parameters, and lifetime of the electrodes were systematically studied using X-ray diffraction, scanning electron microscopy, cyclic voltammetry, linear sweep voltammetry, and chronopotentiometry. Dissolved ozone was produced in a quartz cell and its concentration was monitored by in situ UV spectrophotometry. The presence of small amounts of Ni (Ni : Sn atomic ratio of 0.2 : 100) gives valuable characteristics to the electrodes such as increasing EOP activity and service life. Higher Ni concentrations increase the electrode film resistance and decrease its capacitance, roughness factor, and service life, while increasing Sb level up to 12 atom% improves the electrode performance with respect to these parameters. Nevertheless, the Sb/Sn atomic ratio of more than 2% reduces the EOP current efficiency in favor of OER. The optimum composition of the electrode for EOP was determined to be Sb/Sn and Ni/Sn atomic ratios of 2% and 0.2%, respectively. The highest current efficiency was 48.3% in 0.1 M H2SO4solution at room temperature.
- 1 January 2011
- Published by Wiley in International Journal of Electrochemistry
- Vol. 2011 (1) , 1-13
Open AccessEffect of Elemental Composition on the Structure, Electrochemical Properties, and Ozone Production Activity of Ti/Sn-Sb-Ni Electrodes Prepared by Thermal Pyrolysis MethodTi/SnO2-Sb-Ni electrodes with various Ni- and Sb-doping levels have been prepared by dip-coating thermal pyrolysis procedure, and their simultaneous electrochemical ozone production (EOP) and oxygen evolution reaction (OER) were investigated. The effects of electrode composition on the nanostructure, morphology, electrochemical behavior, kinetic parameters, and lifetime of the electrodes were systematically studied using X-ray diffraction, scanning electron microscopy, cyclic voltammetry, linear sweep voltammetry, and chronopotentiometry. Dissolved ozone was produced in a quartz cell and its concentration was monitored by in situ UV spectrophotometry. The presence of small amounts of Ni (Ni : Sn atomic ratio of 0.2 : 100) gives valuable characteristics to the electrodes such as increasing EOP activity and service life. Higher Ni concentrations increase the electrode film resistance and decrease its capacitance, roughness factor, and service life, while increasing Sb level up to 12 atom% improves the electrode performance with respect to these parameters. Nevertheless, the Sb/Sn atomic ratio of more than 2% reduces the EOP current efficiency in favor of OER. The optimum composition of the electrode for EOP was determined to be Sb/Sn and Ni/Sn atomic ratios of 2% and 0.2%, respectively. The highest current efficiency was 48.3% in 0.1 M H2SO4solution at room temperature.
- 3 March 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 390 (7) , 1943-1950
An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane
An optical chemical sensor based on 2-mercaptopyrimidine (2-MP) in plasticized poly(vinyl chloride) (PVC) membrane incorporating (N,N-diethyl-5-(octadecanoylimino)-5H benzo[a]phenoxazine-9-amine (ETH 5294) and sodium tetraphenyl borate (NaTPB) for batch and flow-through determination of mercury ion is described. The response of the sensor is based on selective complexation of Hg2+ with 2-MP in the membrane phase, resulting in an ion exchange process between H+ in the membrane and Hg2+ in the sample solution. The influences of several experimental parameters, such as membrane composition, pH, and type and concentration of the regenerating reagent, were investigated. The sensor has a response range of 2.0 × 10−9 to 2.0 × 10−5 mol L−1 Hg2+ with a detection limit of 4.0 × 10−10 mol L−1 and a response time of ≤45 s at optimum pH of 6.5 with high measurement repeatability and sensor-to-sensor reproducibility. It shows high selectivity for Hg2+ over several transition metal ions, including Ag+, Cd2+, Co2+, Cr3+, Cu2+, Fe3+, Mn2+, Ni2+, and common alkali and alkaline earth ions such as Na+, K+, Mg2+, Ca2+, and Pb2+. The sensor membrane can be easily regenerated with dilute acid solutions. The sensor has been used for the determination of mercury ion concentration in water samples.
- 3 March 2008
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 390 (7) , 1943-1950
An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane
An optical chemical sensor based on 2-mercaptopyrimidine (2-MP) in plasticized poly(vinyl chloride) (PVC) membrane incorporating (N,N-diethyl-5-(octadecanoylimino)-5H benzo[a]phenoxazine-9-amine (ETH 5294) and sodium tetraphenyl borate (NaTPB) for batch and flow-through determination of mercury ion is described. The response of the sensor is based on selective complexation of Hg2+ with 2-MP in the membrane phase, resulting in an ion exchange process between H+ in the membrane and Hg2+ in the sample solution. The influences of several experimental parameters, such as membrane composition, pH, and type and concentration of the regenerating reagent, were investigated. The sensor has a response range of 2.0 × 10−9 to 2.0 × 10−5 mol L−1 Hg2+ with a detection limit of 4.0 × 10−10 mol L−1 and a response time of ≤45 s at optimum pH of 6.5 with high measurement repeatability and sensor-to-sensor reproducibility. It shows high selectivity for Hg2+ over several transition metal ions, including Ag+, Cd2+, Co2+, Cr3+, Cu2+, Fe3+, Mn2+, Ni2+, and common alkali and alkaline earth ions such as Na+, K+, Mg2+, Ca2+, and Pb2+. The sensor membrane can be easily regenerated with dilute acid solutions. The sensor has been used for the determination of mercury ion concentration in water samples.