Randolf Hanke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Randolf Hanke has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Simon Zabler
Deggendorf Institute of Technology
2 shared publications - Andreas Balles
Fraunhofer IIS division EZRT 97074 Würzburg Germany
1 shared publication - Antje Dietrich
OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
1 shared publication Arndt Last
Karlsruhe Institute of Technology, Institute of Microstructure Technology (KIT/IMT), 76344 Eggenstein-Leopoldshafen, Germany
1 shared publicationChristian Fella
28450 Fraunhofer Development Center X-ray Technology EZRT , Josef-Martin Weg 63 , Würzburg , Germany
1 shared publication- Christian Fella
Chair for X-ray Microscopy, Julius-Maximilians-Universität Würzburg, 97074 Würzburg, Germany
1 shared publication
Latest Publications
- 1 April 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (4) , 211-226
X-ray imaging and computed tomography for engineering applications
After an incremental development which took place over four decades, X-ray imaging has become an important tool for non-destructive testing and evaluation. Computed Tomography (CT) in particular beholds the power of determining the location of flaws and inclusions (e. g. in castings and composites) in three-dimensional object coordinates. Therefore, and thanks to a speed-up of the measurement, CT is now routinely considered for in-line inspection of electronics, castings and composites. When precision and not speed is important, Micro-CT (μCT) can be employed for Dimensional Measurements (DM, e. g. quality assurance and shape verification), as well as for in situ testing, and for characterizing micro-structures in metals and composites. Using appropriate image processing and analysis μCT can determine the local fibre orientation in composites, the granular morphology of battery cathodes or the inter-connectivity of certain phases in casting alloys. Today, the large variety of X-ray instruments and methods poses an application problem which requires experience and a lot of knowledge for deciding which technique applies best to the task at hand. Application-specific guidelines exist for X-ray radiography testing (RT) only, whereas standardization has been applied to CT, unfortunately leaving out high resolution sub μ CT, and nano-CT. For the latter exist an equally high number of NDT applications, however these instruments still necessitate a profound expertise. The task is to identify key industrial applications and push CT from system standardization to application specific automation.
- 1 April 2020
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (4) , 211-226
X-ray imaging and computed tomography for engineering applications
After an incremental development which took place over four decades, X-ray imaging has become an important tool for non-destructive testing and evaluation. Computed Tomography (CT) in particular beholds the power of determining the location of flaws and inclusions (e. g. in castings and composites) in three-dimensional object coordinates. Therefore, and thanks to a speed-up of the measurement, CT is now routinely considered for in-line inspection of electronics, castings and composites. When precision and not speed is important, Micro-CT (μCT) can be employed for Dimensional Measurements (DM, e. g. quality assurance and shape verification), as well as for in situ testing, and for characterizing micro-structures in metals and composites. Using appropriate image processing and analysis μCT can determine the local fibre orientation in composites, the granular morphology of battery cathodes or the inter-connectivity of certain phases in casting alloys. Today, the large variety of X-ray instruments and methods poses an application problem which requires experience and a lot of knowledge for deciding which technique applies best to the task at hand. Application-specific guidelines exist for X-ray radiography testing (RT) only, whereas standardization has been applied to CT, unfortunately leaving out high resolution sub μ CT, and nano-CT. For the latter exist an equally high number of NDT applications, however these instruments still necessitate a profound expertise. The task is to identify key industrial applications and push CT from system standardization to application specific automation.
- 1 December 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (12) , 123702
Hybrid setup for micro- and nano-computed tomography in the hard X-ray range
With increasing miniaturization in industry and medical technology, non-destructive testing techniques are an area of ever-increasing importance. In this framework, X-ray microscopy offers an efficient tool for the analysis, understanding, and quality assurance of microscopic samples, in particular as it allows reconstructing three-dimensional data sets of the whole sample’s volume via computed tomography (CT). The following article describes a compact X-ray microscope in the hard X-ray regime around 9 keV, based on a highly brilliant liquid-metal-jet source. In comparison to commercially available instruments, it is a hybrid that works in two different modes. The first one is a micro-CT mode without optics, which uses a high-resolution detector to allow scans of samples in the millimeter range with a resolution of 1 μm. The second mode is a microscope, which contains an X-ray optical element to magnify the sample and allows resolving 150 nm features. Changing between the modes is possible without moving the sample. Thus, the instrument represents an important step towards establishing high-resolution laboratory-based multi-mode X-ray microscopy as a standard investigation method.
- 1 December 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (12) , 123702
Hybrid setup for micro- and nano-computed tomography in the hard X-ray range
With increasing miniaturization in industry and medical technology, non-destructive testing techniques are an area of ever-increasing importance. In this framework, X-ray microscopy offers an efficient tool for the analysis, understanding, and quality assurance of microscopic samples, in particular as it allows reconstructing three-dimensional data sets of the whole sample’s volume via computed tomography (CT). The following article describes a compact X-ray microscope in the hard X-ray regime around 9 keV, based on a highly brilliant liquid-metal-jet source. In comparison to commercially available instruments, it is a hybrid that works in two different modes. The first one is a micro-CT mode without optics, which uses a high-resolution detector to allow scans of samples in the millimeter range with a resolution of 1 μm. The second mode is a microscope, which contains an X-ray optical element to magnify the sample and allows resolving 150 nm features. Changing between the modes is possible without moving the sample. Thus, the instrument represents an important step towards establishing high-resolution laboratory-based multi-mode X-ray microscopy as a standard investigation method.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8506, 850617
High-resolution and high-speed CT in industry and research
The application of industrial CT covers many orders of magnitude of object sizes, ranging from freight containers (few meters) down to liquid foams (i.e. for food industry) or even parts of insects which are only several hundreds of micrometers in size. Similarly, the specifications for acquisition speed extend over some orders of magnitude, from hours to sub-second CT. We present the current technology in terms of X-ray sources and detectors, along with numerous applications from industry and materials research: e.g. industrial high-speed CT of car pistons, in situ micro-CT of milk foam decay at micrometer spatial resolution and 8 s scan time, as well as ex situ scans of tensile tested Nickel-alloys. The Fraunhofer Development Center X-ray Technology (Fürth, Germany) and the Chair of X-ray Microscopy (University Würzburg, Germany) are currently working on extending the technological limits, demonstrated, e,g. by the development of advanced X-ray detectors or a new inhouse CT system which comprises a high-brilliance liquid metal jet anode.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8506, 850617
High-resolution and high-speed CT in industry and research
The application of industrial CT covers many orders of magnitude of object sizes, ranging from freight containers (few meters) down to liquid foams (i.e. for food industry) or even parts of insects which are only several hundreds of micrometers in size. Similarly, the specifications for acquisition speed extend over some orders of magnitude, from hours to sub-second CT. We present the current technology in terms of X-ray sources and detectors, along with numerous applications from industry and materials research: e.g. industrial high-speed CT of car pistons, in situ micro-CT of milk foam decay at micrometer spatial resolution and 8 s scan time, as well as ex situ scans of tensile tested Nickel-alloys. The Fraunhofer Development Center X-ray Technology (Fürth, Germany) and the Chair of X-ray Microscopy (University Würzburg, Germany) are currently working on extending the technological limits, demonstrated, e,g. by the development of advanced X-ray detectors or a new inhouse CT system which comprises a high-brilliance liquid metal jet anode.