Jongwoo Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jongwoo Kim has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Chunwoo Kim
Center for Medical Robotics, Korea Institute of Science and Technology, Seoul, South Korea
4 shared publications - Dongwhi Choi
Department of Mechanical Engineering (Integrated Engineering Program) Kyung Hee University Yongin Gyeonggi South Korea
3 shared publications James Drake
The Wilfred and Joyce Posluns Centre for Image-Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, Canada
3 shared publications- Kyu-Jin Cho
Seoul National University, Seoul, Republic of Korea
3 shared publications - Sungchul Kang
Robot Center, Samsung Research, Seoul, South Korea
3 shared publications - Jaehyun Lee
Biomedical and Intelligent Robotics Laboratory, Department of Mechanical Engineering, Kyung Hee University, 1732 Deogyeong-daero, Yongin 17104, Republic of Korea
2 shared publications
Latest Publications
- 2 September 2026
- Published by Springer Nature
- p. 414-422
Hybrid Actuated Soft Origami Robot with Helical Tendon Routing
- 2 September 2026
- Published by Springer Nature
- p. 414-422
Hybrid Actuated Soft Origami Robot with Helical Tendon Routing
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Bifurcation-Gated Kresling Origami Triboelectric Mechanoreceptor Enabling Self-Powered Multimodal Tactile Sensing for Intelligent Human-Robot Interaction
Tactile sensors play major roles in human-robot interaction (HRI) by providing essential feedback on physical stimuli. To achieve human-like perception, it is critical to emulate the dual-sensing capability of cutaneous mechanoreceptors, comprising Fast-Adaptive (FA) receptors responding to dynamic stimuli, and Slow-Adaptive (SA) receptors producing sustained responses to static stimuli. While triboelectric tactile sensors serve as substantial solutions, their sensing capability is primarily optimized for dynamic motion. In this study, we introduce a bifurcation-gated sensing strategy embodied in a Bio-inspired Origami-based Triboelectric mechanoreceptor (BOT) that discriminates between dynamic and static stimuli through a single compliant structure. The Kresling origami of BOT exhibits a kinematic bifurcation at a buckling threshold. Below this threshold, dynamic loads produce FA mode, whereas static loads exceeding the threshold activate a SA mode that generates sustained signals during deformation. The BOT achieves highly linear sensing of indentation depth and normal force. Its practical utility is demonstrated through a self-powered collision detection system for safety and a deep learning-based material recognition framework capable of identifying properties under electromagnetic interference (EMI) environments. This work establishes the bifurcation-gated design principle as alternative to multi-mechanism, opening a pathway toward triboelectric tactile sensors with mechanical property perception for HRI systems.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBifurcation-Gated Kresling Origami Triboelectric Mechanoreceptor Enabling Self-Powered Multimodal Tactile Sensing for Intelligent Human-Robot Interaction
Tactile sensors play major roles in human-robot interaction (HRI) by providing essential feedback on physical stimuli. To achieve human-like perception, it is critical to emulate the dual-sensing capability of cutaneous mechanoreceptors, comprising Fast-Adaptive (FA) receptors responding to dynamic stimuli, and Slow-Adaptive (SA) receptors producing sustained responses to static stimuli. While triboelectric tactile sensors serve as substantial solutions, their sensing capability is primarily optimized for dynamic motion. In this study, we introduce a bifurcation-gated sensing strategy embodied in a Bio-inspired Origami-based Triboelectric mechanoreceptor (BOT) that discriminates between dynamic and static stimuli through a single compliant structure. The Kresling origami of BOT exhibits a kinematic bifurcation at a buckling threshold. Below this threshold, dynamic loads produce FA mode, whereas static loads exceeding the threshold activate a SA mode that generates sustained signals during deformation. The BOT achieves highly linear sensing of indentation depth and normal force. Its practical utility is demonstrated through a self-powered collision detection system for safety and a deep learning-based material recognition framework capable of identifying properties under electromagnetic interference (EMI) environments. This work establishes the bifurcation-gated design principle as alternative to multi-mechanism, opening a pathway toward triboelectric tactile sensors with mechanical property perception for HRI systems.
- Open Access
- 20 April 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (4) , 285
Multi-Gait In-Pipe Locomotion via Programmable Friction Reorientation
In-pipe robots must navigate narrow, curved passages where rigid mechanisms often require bulky steering units. Soft crawlers offer better compliance but typically rely on multiple actuators or reconfigurable contacts to achieve multi-directional motion. Drawing inspiration from biological soft crawlers that exploit directional friction and coordinated anchor–slip patterns, this study focuses on locomotion principles observed in caterpillars, water boatmen, and whirligig beetles. Based on these bioinspired concepts, we present a tendon-driven soft in-pipe robot that combines continuum bending–twisting deformation with modular anisotropic friction pads (AFPs), enabling three locomotion modes using only two motors. AFP inclination, curvature, and ridge geometry were optimized through friction tests, constant-curvature modeling, and finite element analysis to enhance directional adhesion on flat and curved surfaces. A deformation-based locomotion framework was developed to couple tendon actuation with friction orientation, achieving longitudinal crawling, transverse translation, in-place rotation, and smooth transitions via programmed twisting. Driving experiments demonstrated repeatable anchor–slip locomotion with average speeds of 28.6 mm/s, 15.7 mm/s, and 11.5°/s for the three modes. Pipe tests in straight, curved, and T-junction sections further validated stable contact and reliable gait transitions. These findings highlight the potential of friction-programmed continuum robots as compact, bioinspired platforms for advanced in-pipe inspection and diagnostic tasks.
- 20 April 2026
- Published by MDPI AG in Biomimetics
- Vol. 11 (4) , 285
Open AccessMulti-Gait In-Pipe Locomotion via Programmable Friction Reorientation
In-pipe robots must navigate narrow, curved passages where rigid mechanisms often require bulky steering units. Soft crawlers offer better compliance but typically rely on multiple actuators or reconfigurable contacts to achieve multi-directional motion. Drawing inspiration from biological soft crawlers that exploit directional friction and coordinated anchor–slip patterns, this study focuses on locomotion principles observed in caterpillars, water boatmen, and whirligig beetles. Based on these bioinspired concepts, we present a tendon-driven soft in-pipe robot that combines continuum bending–twisting deformation with modular anisotropic friction pads (AFPs), enabling three locomotion modes using only two motors. AFP inclination, curvature, and ridge geometry were optimized through friction tests, constant-curvature modeling, and finite element analysis to enhance directional adhesion on flat and curved surfaces. A deformation-based locomotion framework was developed to couple tendon actuation with friction orientation, achieving longitudinal crawling, transverse translation, in-place rotation, and smooth transitions via programmed twisting. Driving experiments demonstrated repeatable anchor–slip locomotion with average speeds of 28.6 mm/s, 15.7 mm/s, and 11.5°/s for the three modes. Pipe tests in straight, curved, and T-junction sections further validated stable contact and reliable gait transitions. These findings highlight the potential of friction-programmed continuum robots as compact, bioinspired platforms for advanced in-pipe inspection and diagnostic tasks.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (4) , 1-9
Design and Coupled Bending–Axial Strain Modeling of a Bi-Material Push–Pull Robot
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (4) , 1-9
Design and Coupled Bending–Axial Strain Modeling of a Bi-Material Push–Pull Robot
- 26 December 2023
- Published by Springer Nature in Intelligent Service Robotics
- Vol. 17 (1) , 3-17
Soft actuators in surgical robotics: a state-of-the-art review
- 26 December 2023
- Published by Springer Nature in Intelligent Service Robotics
- Vol. 17 (1) , 3-17
Soft actuators in surgical robotics: a state-of-the-art review
- Open Access
Tendon-Driven Crawling Robot with Programmable Anisotropic Friction by Adjusting Out-of-Plane Curvature
Origami crawling robots, inspired by the principles of origami folding, have emerged as a promising approach for developing lightweight and flexible robots capable of navigating tight spaces. These robots utilize anisotropic friction, where the frictional forces between surfaces vary depending on the direction of motion, enabling controlled movement by changing the robot’s body orientation. While various actuation methods have been explored, such as pneumatic and magnetic systems, they suffer from limitations such as bulkiness or restricted workspace. In this paper, we propose a tendon-driven crawling robot that achieves anisotropic friction by controlling its out-of-plane curvature. By manipulating the robot’s shape and out-of-plane curvature, we can modulate the friction forces and enable efficient crawling motion. To maximize anisotropic friction, we design an asymmetric contact film composed of elastomer and polyester. We analyze the relationship between out-of-plane curvature and frictional force through experiments on flat and sloped surfaces, considering different leg angles and slope angles of the contact film. The results demonstrate the gait loss ratio of 1.96% for the optimized design, highlighting the robot’s ability to crawl efficiently with quick response times and a low-profile system. This research contributes to the advancement of origami-based crawling robots and their potential applications in confined and unstructured environments.
Open AccessTendon-Driven Crawling Robot with Programmable Anisotropic Friction by Adjusting Out-of-Plane Curvature
Origami crawling robots, inspired by the principles of origami folding, have emerged as a promising approach for developing lightweight and flexible robots capable of navigating tight spaces. These robots utilize anisotropic friction, where the frictional forces between surfaces vary depending on the direction of motion, enabling controlled movement by changing the robot’s body orientation. While various actuation methods have been explored, such as pneumatic and magnetic systems, they suffer from limitations such as bulkiness or restricted workspace. In this paper, we propose a tendon-driven crawling robot that achieves anisotropic friction by controlling its out-of-plane curvature. By manipulating the robot’s shape and out-of-plane curvature, we can modulate the friction forces and enable efficient crawling motion. To maximize anisotropic friction, we design an asymmetric contact film composed of elastomer and polyester. We analyze the relationship between out-of-plane curvature and frictional force through experiments on flat and sloped surfaces, considering different leg angles and slope angles of the contact film. The results demonstrate the gait loss ratio of 1.96% for the optimized design, highlighting the robot’s ability to crawl efficiently with quick response times and a low-profile system. This research contributes to the advancement of origami-based crawling robots and their potential applications in confined and unstructured environments.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 889-900
Design and Performance Evaluation of a Novel Compliant Wrist for Minimally Invasive Middle Ear Surgery
Objective: To present the design choices, modelling of bending stiffness and experimental validation of a novel notched Nitinol compliant wrist that enables tip articulation and suction during endoscopic and robotic middle ear surgery. Methods: The wrist consists of an inner wrist tube (IWT) assembled within an outer wrist tube (OWT). The OWT was selected from five concept designs that were evaluated based on stiffness and compact bending. An analytical model was developed based on Castigliano’s 2nd Theorem and a finite element model (FEM) was developed to predict tip stiffness under soft-tissue surgical interactions and compared to experimental results. Results: The FEM and analytical models predicted tip displacement due to an applied force within 25% and 12 % of the experimental results, respectively. The complete wrist prototype withstood 700-1000 cycles before fracture when it was articulated up to 145∘ -178∘, corresponding to 9.6 N -12.4 N of cable tension. Conclusion: A wristed tool is presented to facilitate endoscopic ear surgery and its mechanical behaviour in surgically relevant loading conditions. Significance: This instrument could be adapted to provide suction and soft tissue dissection capabilities for future minimally invasive endoscopic or robotic surgery, through the ear canal or other natural orifices.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 889-900
Design and Performance Evaluation of a Novel Compliant Wrist for Minimally Invasive Middle Ear Surgery
Objective: To present the design choices, modelling of bending stiffness and experimental validation of a novel notched Nitinol compliant wrist that enables tip articulation and suction during endoscopic and robotic middle ear surgery. Methods: The wrist consists of an inner wrist tube (IWT) assembled within an outer wrist tube (OWT). The OWT was selected from five concept designs that were evaluated based on stiffness and compact bending. An analytical model was developed based on Castigliano’s 2nd Theorem and a finite element model (FEM) was developed to predict tip stiffness under soft-tissue surgical interactions and compared to experimental results. Results: The FEM and analytical models predicted tip displacement due to an applied force within 25% and 12 % of the experimental results, respectively. The complete wrist prototype withstood 700-1000 cycles before fracture when it was articulated up to 145∘ -178∘, corresponding to 9.6 N -12.4 N of cable tension. Conclusion: A wristed tool is presented to facilitate endoscopic ear surgery and its mechanical behaviour in surgically relevant loading conditions. Significance: This instrument could be adapted to provide suction and soft tissue dissection capabilities for future minimally invasive endoscopic or robotic surgery, through the ear canal or other natural orifices.
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (8) , 8190-8200
Design Optimization of Asymmetric Patterns for Variable Stiffness of Continuum Tubular Robots
Variable stiffness mechanisms have become popular for improving the performance of meso/microscale robots due to their ability to enable safe, effective, and versatile operation without additional actuators. In minimally invasive surgery (MIS), they can provide low stiffness for adaptability and an extended workspace and high stiffness for stable manipulation. This study aims to optimize the pattern design that maximizes the stiffness ratio while preventing buckling. Longitudinal slits are identified as the ideal shape for maximizing the ratio using topology optimization. The effects of the design parameters are investigated by analytical modeling and finite-element analysis (FEA). Finally, we established a design optimization process to maximize the variable stiffness ratio while ensuring safety. The load and buckling tests of 19 cases are verified in both the experiment and FEA. Buckling occurred in eight cases, consistent with the expected results from the proposed map. Among the tested cases, the tube with the optimal pattern parameter set exhibits the highest stiffness ratio of 2.67 while satisfying the given stiffness constraint (greater than 0.3 times the flexural stiffness of the initial tube) and avoiding buckling. The proposed optimization method potentially enables an extended workspace and more versatile functionality for MIS instruments.
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (8) , 8190-8200
Design Optimization of Asymmetric Patterns for Variable Stiffness of Continuum Tubular Robots
Variable stiffness mechanisms have become popular for improving the performance of meso/microscale robots due to their ability to enable safe, effective, and versatile operation without additional actuators. In minimally invasive surgery (MIS), they can provide low stiffness for adaptability and an extended workspace and high stiffness for stable manipulation. This study aims to optimize the pattern design that maximizes the stiffness ratio while preventing buckling. Longitudinal slits are identified as the ideal shape for maximizing the ratio using topology optimization. The effects of the design parameters are investigated by analytical modeling and finite-element analysis (FEA). Finally, we established a design optimization process to maximize the variable stiffness ratio while ensuring safety. The load and buckling tests of 19 cases are verified in both the experiment and FEA. Buckling occurred in eight cases, consistent with the expected results from the proposed map. Among the tested cases, the tube with the optimal pattern parameter set exhibits the highest stiffness ratio of 2.67 while satisfying the given stiffness constraint (greater than 0.3 times the flexural stiffness of the initial tube) and avoiding buckling. The proposed optimization method potentially enables an extended workspace and more versatile functionality for MIS instruments.
- 6 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 8309-8316
Design Optimization for the Stability of Concentric Tube Robots
Concentric tube robots are catheter-sized continuum robots that show dexterous movement for minimally invasive surgical procedures. However, one of the major challenges to the practical usage of concentric tube robots is their instability, which potentially leads to the risk of tissue rupture. The snapping problem is caused by tubes having a high bending to torsional stiffness ratio (BTSR). Past efforts have shown that anisotropic patterning on tubes can alleviate the snapping problem. This research investigates the design optimization of patterns to minimize BTSR while satisfying stiffness constraints. Using topology optimization methods, rhombus-shaped patterns were identified as the ideal shape for stability. The generated designs were validated through finite element analysis and experimental testing to show the change of BTSR and the elimination of the snapping problem. Extensive parametric study is performed to analysis the sensitivity of the design parameters and provide the design guidelines. While satisfying the constraints, the proposed design method demonstrated 0.28 of BTSR with a rhombus angle of 60 degrees and a volume fraction of 0.55. The optimized design potentially improves the workspace and versatile trajectories of concentric tube manipulators.
- 6 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 8309-8316
Design Optimization for the Stability of Concentric Tube Robots
Concentric tube robots are catheter-sized continuum robots that show dexterous movement for minimally invasive surgical procedures. However, one of the major challenges to the practical usage of concentric tube robots is their instability, which potentially leads to the risk of tissue rupture. The snapping problem is caused by tubes having a high bending to torsional stiffness ratio (BTSR). Past efforts have shown that anisotropic patterning on tubes can alleviate the snapping problem. This research investigates the design optimization of patterns to minimize BTSR while satisfying stiffness constraints. Using topology optimization methods, rhombus-shaped patterns were identified as the ideal shape for stability. The generated designs were validated through finite element analysis and experimental testing to show the change of BTSR and the elimination of the snapping problem. Extensive parametric study is performed to analysis the sensitivity of the design parameters and provide the design guidelines. While satisfying the constraints, the proposed design method demonstrated 0.28 of BTSR with a rhombus angle of 60 degrees and a volume fraction of 0.55. The optimized design potentially improves the workspace and versatile trajectories of concentric tube manipulators.