JPJames M. Pope

James M. Pope

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James M. Pope has a total of 167 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measuring refractive index distribution in the human eye lens

    by James M. Pope, David A. Atchison


  • Open Access

    Validation of a partial coherence interferometry method for estimating retinal shape

    by Pavan K. Verkicharla, Marwan Suheimat, James M. Pope, Farshid Sepehrband, Ankit Mathur, Katrina L. Schmid, David A. Atchison

    To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data.


  • Open Access

    Lens Shape and Refractive Index Distribution in Type 1 Diabetes

    by Adnan, James M. Pope, Farshid Sepehrband, Marwan Suheimat, Pavan K. Verkicharla, Sanjeev Kasthurirangan, David A. Atchison

    Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.


  • Open Access

    Simultaneous Magnetic Resonance Imaging and Consolidation Measurement of Articular Cartilage

    by Robert Mark Wellard, Jean-Philippe Ravasio, Samuel Guesne, Christopher Bell, Adekunle Oloyede, Greg Tevelen, James M. Pope, Konstantin I. Momot

    Magnetic resonance imaging (MRI) offers the opportunity to study biological tissues and processes in a non-disruptive manner. The technique shows promise for the study of the load-bearing performance (consolidation) of articular cartilage and changes in articular cartilage accompanying osteoarthritis. Consolidation of articular cartilage involves the recording of two transient characteristics: the change over time of strain and the hydrostatic excess pore pressure (HEPP). MRI study of cartilage consolidation under mechanical load is limited by difficulties in measuring the HEPP in the presence of the strong magnetic fields associated with the MRI technique. Here we describe the use of MRI to image and characterize bovine articular cartilage deforming under load in an MRI compatible consolidometer while monitoring pressure with a Fabry-Perot interferometer-based fiber-optic pressure transducer.


  • Methods to Estimate the Size and Shape of the Unaccommodated Crystalline Lens In Vivo

    by Jos J. Rozema, David A. Atchison, Sanjeev Kasthurirangan, James M. Pope, Marie-José Tassignon

    Purpose.: The purpose of this article was to present methods capable of estimating the size and shape of the human eye lens without resorting to phakometry or magnetic resonance imaging (MRI). Methods.: Previously published biometry and phakometry data of 66 emmetropic eyes of 66 subjects (age range [18, 63] years, spherical equivalent range [−0.75, +0.75] D) were used to define multiple linear regressions for the radii of curvature and thickness of the lens, from which the lens refractive index could be derived. MRI biometry was also available for a subset of 30 subjects, from which regressions could be determined for the vertex radii of curvature, conic constants, equatorial diameter, volume, and surface area. All regressions were compared with the phakometry and MRI data; the radii of curvature regressions were also compared with a method proposed by Bennett and Royston et al. Results.: The regressions were in good agreement with the original measurements. This was especially the case for the regressions of lens thickness, volume, and surface area, which each had an R 2 > 0.6. The regression for the posterior radius of curvature had an R 2 < 0.2, making this regression unreliable. For all other regressions we found 0.25 < R 2 < 0.6. The Bennett-Royston method also produced a good estimation of the radii of curvature, provided its parameters were adjusted appropriately. Conclusions.: The regressions presented in this article offer a valuable alternative in case no measured lens biometry values are available; however care must be taken for possible outliers.


  • Eye shape and retinal shape, and their relation to peripheral refraction

    by Pavan K Verkicharla, Ankit Mathur, Edward Ah Mallen, James M Pope, David A Atchison

    Citation information: Verkicharla PK, Mathur A, Mallen EAH, Pope JM & Atchison DA. Eye shape and retinal shape, and their relation to peripheral refraction. Ophthalmic Physiol Opt 2012, 32 , 184–199. doi: 10.1111/j.1475‐1313.2012.00906.x Purpose:  We provide an account of the relationships between eye shape, retinal shape and peripheral refraction. Recent findings:  We discuss how eye and retinal shapes may be described as conicoids, and we describe an axis and section reference system for determining shapes. Explanations are given of how patterns of retinal expansion during the development of myopia may contribute to changing patterns of peripheral refraction, and how pre‐existing retinal shape might contribute to the development of myopia. Direct and indirect techniques for determining eye and retinal shape are described, and results are discussed. There is reasonable consistency in the literature of eye length increasing at a greater rate than height and width as the degree of myopia increases, so that eyes may be described as changing from oblate/spherical shapes to prolate shapes. However, one study indicates that the retina itself, while showing the same trend, remains oblate in shape for most eyes (discounting high myopia). Eye shape and retinal shape are not the same and merely describing an eye shape as being prolate or oblate is insufficient without some understanding of the parameters contributing to this; in myopia a prolate eye shape is likely to involve both a steepening retina near the posterior pole combined with a flattening (or a reduction in steepening compared with an emmetrope) away from the pole. Summary:  In the recent literature, eye and/or retinal shape have often been inferred from peripheral refraction, and, to a lesser extent, vice versa . Because both the eye’s optics and the retinal shape contribute to the peripheral refraction, and there is large variation in the latter, this inference should be made cautiously. Recently retinal shape has been measured independent of optical methods using magnetic resonance imaging. For further work on retinal shape, determining the validity of cheaper alternatives to magnetic resonance techniques is required.


  • Anisotropy of spin relaxation of water protons in cartilage and tendon

    by Konstantin I. Momot, James M. Pope, R. Mark Wellard

    Transverse spin relaxation rates of water protons in articular cartilage and tendon depend on the orientation of the tissue relative to the applied static magnetic field. This complicates the interpretation of magnetic resonance images of these tissues. At the same time, relaxation data can provide information about their organisation and microstructure. We present a theoretical analysis of the anisotropy of spin relaxation of water protons observed in fully hydrated cartilage. We demonstrate that the anisotropy of transverse relaxation is due almost entirely to intramolecular dipolar coupling modulated by a specific mode of slow molecular motion: the diffusion of water molecules in the hydration shell of a collagen fibre around the fibre, such that the molecular director remains perpendicular to the fibre. The theoretical anisotropy arising from this mechanism follows the ‘magic‐angle’ dependence observed in magnetic‐resonance measurements of cartilage and tendon and is in good agreement with the available experimental results. We discuss the implications of the theoretical findings for MRI of ordered collagenous tissues. Copyright © 2009 John Wiley & Sons, Ltd.


  • Mathematical models for describing the shape of the in vitro unstretched human crystalline lens

    by George Smith, David A. Atchison, D. Robert Iskander, Catherine E. Jones, James M. Pope