Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marthinus Johannes Booysen has a total of 249 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Operational Digital Twin for Electric Bus Depot Charging Infrastructure: Validation and Scenario Analysis at a Sub-Saharan African Fleet

    by Luqmaan Ryklief, Marthinus Johannes Booysen

    Charging infrastructure for battery electric bus (BEB) fleets must be sized against the timing of demand, not only its magnitude: an accurate per-trip energy estimate cannot on its own establish whether a depot’s chargers, contracted grid connection, and dispatch schedule can recover the fleet’s energy deficit without breaching demand-based tariff thresholds. This is especially consequential in resource-constrained settings, where notified-maximum-demand penalties and steep time-of-use differentials turn a mistimed charging load into a direct commercial liability rather than an operational inconvenience. Yet pre-investment planning tools typically treat vehicle energy consumption, dispatch scheduling, and charging infrastructure as separate problems, so a validated demand estimate rarely translates into a validated depot load profile. This paper presents an operational digital twin that converts the per-trip arrival state-of-charge predicted by a companion rolling stock twin into a depot-level charging load profile for the Golden Arrow Bus Services (GABS) electric fleet at the Arrowgate depot in Cape Town, South Africa. The twin reconstructs each bus’s daily duty chain from scheduling data to determine its available charging window, then simulates session initiation, power draw, and duration against these windows using charging behaviour parametrised from depot Open Charge Point Protocol (OCPP) records, including the smart charging constraints already enforced at the depot. Each bus’s state of charge is carried from one depot visit to the next, so an undercharged departure reappears as a lower arrival rather than disappearing from the model. The simulated load profile is validated against 968 OCPP session records from two periods with different depot hardware, achieving energy-per-session agreement of 4.5 to 7.3% and load-shape correlation of 0.95 to 0.99; on a held-out night not used for calibration, with every recorded session as input, the twin reproduces the depot’s measured overnight peak to within 3.3%, and on a July day with no site pool, with nothing calibrated, its mean overnight load to within 0.8%. The simulated load profile is evaluated against the depot’s contracted notified maximum demand of 3000 kVA. Scenario analysis quantifies how the charging schedule, charger rate, and site pool limit shift the load profile relative to this threshold and to time-of-use cost exposure, showing that scheduling charging into off-peak windows without a site-wide limit can raise peak demand above uncontrolled charging and beyond the contracted threshold (3167 against 1832 kW), that a site pool limit controls peak demand and monthly cost together, and that a 30 kW per-charger cap leaves buses unable to complete up to 15% of their trips; grown to 80 buses, the fleet would exceed the depot’s 2025 connector count before its pool limit, which the twin shows as overnight queueing and stranded trips. By coupling a validated, condition-aware demand layer to depot dispatch and charging logic, this work supports capital-efficient charging-infrastructure decisions for transit operators facing demand-based tariffs and constrained grid capacity, as at Arrowgate, where undersized infrastructure risks service disruption and oversized infrastructure diverts capital from wider electrification.

  • Open Access

    Isolating Climate and Demand Effects in Direct-DC PV-Assisted Water Heating: A Multi-City South African Assessment

    by Felix Walker, Bernd Thomas, M.J. Booysen

    This study uses a single-country comparison to isolate climatic and household-demand effects that were difficult to separate in an earlier cross-country assessment of direct photovoltaic water heating. A 1.68kWp photovoltaic string coupled directly to a 150L electric water heater is simulated at 5-minute resolution across nine South African cities. The thermal and electrical models are held constant, while electricity tariff and grid-emission factors are fixed nationally and module orientation is optimised separately for light, medium, and heavy hot-water demand. This design attributes performance differences to local weather, inlet-water temperature, demand intensity, and PV-load coincidence. Annual solar energy accepted by the heater ranges from 390 to 1580kWh per household, yielding savings of about US$70-290 and avoided emissions of up to about 1450kgCO2. Inland cities outperform coastal locations because of stronger and less variable solar resources. The orientation that maximises the heater's solar fraction lies 15-30deg east of North, and a conventional due-North array at latitude tilt forgoes up to 3.5% of accepted solar energy. The optimum is, however, insensitive to demand class: using the medium-demand orientation for light or heavy users costs at most 0.3%. PV-priority control introduces little avoidable comfort loss for light and medium users, whereas heavy users are more sensitive to extended low-irradiance periods. Once tariff and grid carbon intensity are controlled, local climate and demand behaviour emerge as the dominant determinants of retrofit value.

  • Open Access

    Towards Sustainable Electric Bus Fleet Electrification: An Operational Digital Twin for Pre-Investment Charging Infrastructure Planning in a Resource-Constrained Environment

    by Luqmaan Ryklief, Marthinus Johannes Booysen

    Charging infrastructure for battery electric bus (BEB) fleets must be sized against the timing of demand, not only its magnitude: an accurate per-trip energy estimate cannot on its own establish whether a depot’s chargers, contracted grid connection, and dispatch schedule can recover the fleet’s energy deficit without breaching demand-based tariff thresholds. This is especially consequential in resource-constrained settings, where notified-maximum-demand penalties and steep time-of-use differentials turn a mistimed charging load into a direct commercial liability rather than an operational inconvenience. Yet pre-investment planning tools typically treat vehicle energy consumption, dispatch scheduling, and charging infrastructure as separate problems, so a validated demand estimate rarely translates into a validated depot load profile. This paper presents an operational digital twin that converts the per-trip arrival state-of-charge predicted by a companion rolling stock twin into a depot-level charging load profile for the Golden Arrow Bus Services (GABS) electric fleet at the Arrowgate depot in Cape Town, South Africa. The twin reconstructs each bus’s daily duty chain from scheduling data to determine its available charging window, then simulates session initiation, power draw, and duration against these windows using charging behaviour parametrised from depot Open Charge Point Protocol (OCPP) records, including the smart charging constraints already enforced at the depot. Each bus’s state of charge is carried from one depot visit to the next, so an undercharged departure reappears as a lower arrival rather than disappearing from the model. The simulated load profile is validated against 968 OCPP session records from two periods with different depot hardware, achieving energy-per-session agreement of 4.3 to 7.3 % and load-shape correlation of 0.95 to 0.99, and is evaluated against the depot’s contracted notified maximum demand of 3 000 kVA. Scenario analysis quantifies how the charging schedule, charger rate, and site pool limit shift the load profile relative to this threshold and to time-of-use cost exposure, showing that scheduling charging into off-peak windows without a site-wide limit can raise peak demand above uncontrolled charging and beyond the contracted threshold (3 167 against 1 832 kW), that a site pool limit controls peak demand and monthly cost together, and that a 30 kW per-charger cap leaves buses unable to complete up to 15 % of their trips. By coupling a validated, condition-aware demand layer to depot dispatch and charging logic, this work supports capital-efficient charging infrastructure decisions for transit operators in the Global South, where undersized infrastructure risks service disruption and oversized infrastructure diverts capital from wider electrification.


  • Open Access

    Predicting Avian Observation Patterns in Mediterranean Wetlands: Spatiotemporal Deep Learning Fusion of Multi-Source Surveys, Citizen Science, and Autonomous Acoustic Sensing

    by David Mulero-Pérez, Bruno Sancho-Deltell, Diana Shilova, Laura Saval-Cillero, David Alarcón-Garrido, David Ortiz-Perez, Esther Sebastián-González, Jorge Azorin-Lopez, Marthinus J. Booysen, Ioannis Karydis, et al.

    Protected wetlands in the Mediterranean are vital biodiversity hotspots that face growing pressure from climate change and human activity. Traditional bird monitoring relies on professional field surveys, which, although highly standardized, are resource-constrained and limited in temporal frequency. Here, we present ValWet-Birds, a multi-source spatiotemporal dataset and fusion framework that harmonises and integrates professional counts, eBird citizen science registries, and passive acoustic monitoring (via a BirdNET classifier deployed on a Raspberry Pi 5 node) for three protected wetlands in Alicante, Spain (El Hondo, Santa Pola, and La Mata–Torrevieja), from 2010 to 2025. We normalize incompatible observation protocols into a unified monthly relative observation proportion target across 12 sub-regions and 394 taxa (349 resolved to species level after a taxonomic audit). Spatiotemporal prediction models are implemented using Multi-Layer Perceptron (MLP) and Long Short-Term Memory (LSTM) neural networks. A preliminary evaluation using non-matched test sets suggested a 42.7% reduction in Test Mean Squared Error for the LSTM under multi-source augmentation. Re-evaluating every source condition on an identical held-out set of professional-census observations shows that this benefit does not hold in aggregate: both baselines outperform naive temporal reference predictors by a wide margin, but adding eBird and BirdNET data does not reduce error relative to census-only training overall. The exception is conservation-relevant taxa (a 50-species subset cross-referenced against Annex I of the EU Birds Directive), for which multi-source augmentation reduces LSTM error by 29% and MLP error by 9%, plausibly because these less-common species have sparser census history to draw on. We report this reversal explicitly as a methodological finding in its own right. Finally, we describe the design and interactive user flows of the deployed web visualization platform Avistory, which presents observation summaries and model outputs; it should not be interpreted as a validated population-monitoring or conservation-decision system.

  • Open Access

    Daily Distance, Activity, Mobility Shifts among Observed Minibus Taxis in Gauteng

    by Joshua T. Sello, M.J. Booysen

    Minibus taxis provide a substantial share of daily public transport in South Africa, yet large-sample evidence on how far and how long individual vehicles operate remains limited. This paper uses 174.9 million GPS records from December 2025 to quantify daily distance, movement duration, operating span, active vehicles, time-of-day structure, and persistence among observed minibus taxis. Cleaned, time-ordered observations were aggregated into operational vehicle-days. The Gauteng selection contained 121,739 vehicle-days from 5,020 vehicles between 1 and 31 December; 100,006 vehicle-days from 4,836 vehicles met the analytical criteria. Median daily distance declined from 166 km during 1-25 December to 142 km during 26-31 December, median movement duration declined from 6.1 to 5.1 hours, and median operating span declined from 14.6 to 13.8 hours. The late-period morning profile was delayed, but the evening endpoint changed little: median movement start shifted from 07:19 to 07:43 and median end from 21:58 to 21:48. Within-vehicle day-today variation accounted for 65.2% of distance variation and 75.8% of operating-span variation. Nevertheless, extremedistance activity was concentrated: a vehicle-day above the fleet-wide 90th percentile was 6.1 times more likely after another such day than after a non-tail day. These findings support distributional and risk-based transport planning.

  • Open Access

    Empirical performance assessment of South Africa’s first commercial electric minibus taxi

    by Joshua T. Sello, Chris J. Abraham, Stephan Lacock, M.J. (Thinus) Booysen