Sini Sipari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sini Sipari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Aarno Dietz
Kuopio University Hospital & Institute of Clinical Medicine, University of Eastern Finland, Dept of Otorhinolaryngology, PO Box 100, Kuopio, 70029, Finland
7 shared publications - Matti Iso-Mustajärvi
Department of Otorhinolaryngology, Kuopio University Hospital, Kuopio, Finland
7 shared publications - Heikki Löppönen
Department of Otorhinolaryngology, University of Eastern Finland and Kuopio University Hospital, 70210 Kuopio, Finland
3 shared publications Heikki Löppönen
2 shared publicationsJyrki Tervaniemi
Department of Clinical Radiology, Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
2 shared publicationsAntti Lehtimäki
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
1 shared publication
Latest Publications
- Open Access
- 1 February 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (1) , 1-7
Insertion Results and Hearing Outcomes of a Slim Lateral Wall Electrode
BACKGROUND: The clinical outcomes of cochlear implantation vary for several reasons. It is necessary to study the different electrodes and variables for further development. The aim of this study is to report the clinical outcomes of a new slim lateral wall electrode (SlimJ). METHODS: Data of 25 cochlear implantations in 23 patients with the SlimJ electrode were retrospectively collected. The insertion results were assessed by image fusion of the preoperative computed tomography (CT), magnetic resonance imaging (MRI), and postoperative cone-beam CT. The hearing outcomes were evaluated by the improvement of speech recognition in noise, measured preoperatively and at follow-up. Postoperative pure-tone thresholds were obtained in cases with preoperative functional low frequency hearing [PTA (0.125-0.5 kHz) ≤ 80 dB HL]. RESULTS: The preoperative mean speech reception threshold (SRT) was +0.6 dB signal-to-noise ratio (SNR) (SD ± 4.2 dB) and the postoperative −3.5 dB SNR (SD ± 2.3 dB). The improvements between the preoperative and postoperative SRT levels ranged from 0.0 to 15.1 dB, with a mean improvement of 4.2 dB (SD ± 3.6 dB). Residual hearing in low frequencies (mean PTA(125-500 Hz)) was preserved within 30 dB HL in 70% and within 15 dB HL in 40% of patients who had preoperatively functional low frequency hearing. Mean insertion depth angle (IDA) was 401° (SD ± 41°). We observed scalar translocations from scala tympani to scala vestibuli in 2 ears (9%). CONCLUSION: The relatively atraumatic insertion characteristics make the SlimJ array feasible for hearing preservation cochlear implantation. The hearing outcomes are comparable to those reported for other electrodes and devices Cite this article as: Sipari S, Iso-Mustajärvi M, Linder P, Dietz A. Insertion results and hearing outcomes of a slim lateral wall electrode. J Int Adv Otol. 2024;20(1):1-7.
- 1 February 2024
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 20 (1) , 1-7
Open AccessInsertion Results and Hearing Outcomes of a Slim Lateral Wall Electrode
BACKGROUND: The clinical outcomes of cochlear implantation vary for several reasons. It is necessary to study the different electrodes and variables for further development. The aim of this study is to report the clinical outcomes of a new slim lateral wall electrode (SlimJ). METHODS: Data of 25 cochlear implantations in 23 patients with the SlimJ electrode were retrospectively collected. The insertion results were assessed by image fusion of the preoperative computed tomography (CT), magnetic resonance imaging (MRI), and postoperative cone-beam CT. The hearing outcomes were evaluated by the improvement of speech recognition in noise, measured preoperatively and at follow-up. Postoperative pure-tone thresholds were obtained in cases with preoperative functional low frequency hearing [PTA (0.125-0.5 kHz) ≤ 80 dB HL]. RESULTS: The preoperative mean speech reception threshold (SRT) was +0.6 dB signal-to-noise ratio (SNR) (SD ± 4.2 dB) and the postoperative −3.5 dB SNR (SD ± 2.3 dB). The improvements between the preoperative and postoperative SRT levels ranged from 0.0 to 15.1 dB, with a mean improvement of 4.2 dB (SD ± 3.6 dB). Residual hearing in low frequencies (mean PTA(125-500 Hz)) was preserved within 30 dB HL in 70% and within 15 dB HL in 40% of patients who had preoperatively functional low frequency hearing. Mean insertion depth angle (IDA) was 401° (SD ± 41°). We observed scalar translocations from scala tympani to scala vestibuli in 2 ears (9%). CONCLUSION: The relatively atraumatic insertion characteristics make the SlimJ array feasible for hearing preservation cochlear implantation. The hearing outcomes are comparable to those reported for other electrodes and devices Cite this article as: Sipari S, Iso-Mustajärvi M, Linder P, Dietz A. Insertion results and hearing outcomes of a slim lateral wall electrode. J Int Adv Otol. 2024;20(1):1-7.
- 1 February 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 41 (2) , e216-e222
The Image Fusion Technique for Cochlear Implant Imaging: A Study of its Application for Different Electrode Arrays
Objectives: To investigate the benefits of the image fusion technique for precise postoperative assessment of intracochlear placement with six different electrode arrays. Study Design: Consecutive retrospective case study. Settings: Tertiary referral center. Patients: Analyses of imaging data of 30 patients implanted with six different electrode arrays. Interventions: Electrode reconstructions obtained from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) and/or high-resolution computed tomography (HRCT) registrations to create artefact-free images. Main Outcome Measures: Each electrode's intracochlear position was analyzed with the image fusion reconstructions and compared with the results obtained by CBCT alone. The electrode location was classified according to its position in relation to the basal membrane at four different insertion angles. Results: In 40 out of 151 measurements (26.5%), the location grading obtained by CBCT alone changed after the assessment with the image fusion reconstructions. A significant association was found between deep insertions (over 360 degrees) and the effectiveness of image fusion (p = 0.019). The difference between the impact of the fusion technique for the basal turn versus the apical part was highly significant (p = 0.001). There was no significant difference between the effectiveness of the image fusion and the different electrodes. Conclusions: By utilizing an image fusion technique, a more accurate assessment of electrode placement could be achieved for all types of electrodes. Image fusion was especially beneficial for insertions beyond 360 degrees.
- 1 February 2020
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 41 (2) , e216-e222
The Image Fusion Technique for Cochlear Implant Imaging: A Study of its Application for Different Electrode Arrays
Objectives: To investigate the benefits of the image fusion technique for precise postoperative assessment of intracochlear placement with six different electrode arrays. Study Design: Consecutive retrospective case study. Settings: Tertiary referral center. Patients: Analyses of imaging data of 30 patients implanted with six different electrode arrays. Interventions: Electrode reconstructions obtained from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) and/or high-resolution computed tomography (HRCT) registrations to create artefact-free images. Main Outcome Measures: Each electrode's intracochlear position was analyzed with the image fusion reconstructions and compared with the results obtained by CBCT alone. The electrode location was classified according to its position in relation to the basal membrane at four different insertion angles. Results: In 40 out of 151 measurements (26.5%), the location grading obtained by CBCT alone changed after the assessment with the image fusion reconstructions. A significant association was found between deep insertions (over 360 degrees) and the effectiveness of image fusion (p = 0.019). The difference between the impact of the fusion technique for the basal turn versus the apical part was highly significant (p = 0.001). There was no significant difference between the effectiveness of the image fusion and the different electrodes. Conclusions: By utilizing an image fusion technique, a more accurate assessment of electrode placement could be achieved for all types of electrodes. Image fusion was especially beneficial for insertions beyond 360 degrees.
- Open Access
- 16 December 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 15 (3) , 431-435
A New Application of CBCT Image Fusion in Temporal Bone Studies
OBJECTIVES: Temporal bone (TB) studies are essential during the development of new arrays. Postoperative cochlear histology is still regarded as golden standard for the assessment of electrode localization and trauma though it is time consuming, expensive and technically very demanding. The aim of this study is to investigate whether pre-operative evacuation of perilymph improve the assessment of electrode localization and insertion trauma in TBs applying fusion imaging. The results were compared to a prior validated image fusion technique based on the quantification of the electrode placement. MATERIALS and METHODS: 12 prototype electrodes were implanted in fresh frozen TBs. The perilymph was evacuated from the scale prior to pre-operative cone-beam computer tomography (CBCT). The TB were then immersed in Ringer solution to rehydrated both scalae. After electrode insertion post-operative CBCT were obtained. 3D fusions of the pre- and postoperative registration were reconstructed. The electrode localization with respect to the basilar membrane was visually assessed. RESULTS: The visualization of the BM on the pre-operative scans was achieved beyond the second turn in all TBs. The visual assessment was found to be as accurate as the previously validated fusion technique. There was no statistically significant difference between the methods (p=0.564). The image reconstructions and evaluations, however, were faster to perform and the insertion results are immediately available. CONCLUSION: CBCT in combination with pre- and postoperative image fusion is an accurate method for the post-operative assessment of insertion trauma in TBs. This new application facilitates the identification of the BM and allows for a visual assessment of insertion trauma. Cite this article as: Mustajärvi MI, Sipari S, Lehtimäki A, Tervaniemi J, Löppönen H, Dietz A. A New Application of CBCT Image Fusion in Temporal Bone Studies. J Int Adv Otol 2019; 15(3): 431-5.
- 16 December 2019
- Published by Caleo in The Journal of International Advanced Otology
- Vol. 15 (3) , 431-435
Open AccessA New Application of CBCT Image Fusion in Temporal Bone Studies
OBJECTIVES: Temporal bone (TB) studies are essential during the development of new arrays. Postoperative cochlear histology is still regarded as golden standard for the assessment of electrode localization and trauma though it is time consuming, expensive and technically very demanding. The aim of this study is to investigate whether pre-operative evacuation of perilymph improve the assessment of electrode localization and insertion trauma in TBs applying fusion imaging. The results were compared to a prior validated image fusion technique based on the quantification of the electrode placement. MATERIALS and METHODS: 12 prototype electrodes were implanted in fresh frozen TBs. The perilymph was evacuated from the scale prior to pre-operative cone-beam computer tomography (CBCT). The TB were then immersed in Ringer solution to rehydrated both scalae. After electrode insertion post-operative CBCT were obtained. 3D fusions of the pre- and postoperative registration were reconstructed. The electrode localization with respect to the basilar membrane was visually assessed. RESULTS: The visualization of the BM on the pre-operative scans was achieved beyond the second turn in all TBs. The visual assessment was found to be as accurate as the previously validated fusion technique. There was no statistically significant difference between the methods (p=0.564). The image reconstructions and evaluations, however, were faster to perform and the insertion results are immediately available. CONCLUSION: CBCT in combination with pre- and postoperative image fusion is an accurate method for the post-operative assessment of insertion trauma in TBs. This new application facilitates the identification of the BM and allows for a visual assessment of insertion trauma. Cite this article as: Mustajärvi MI, Sipari S, Lehtimäki A, Tervaniemi J, Löppönen H, Dietz A. A New Application of CBCT Image Fusion in Temporal Bone Studies. J Int Adv Otol 2019; 15(3): 431-5.
- Open Access
- 31 October 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (2) , 367-375
Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode
Purpose: To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods: We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA (0.125–0.5 kHz) ≤ 80 dB HL). The insertion results were re-examined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results: The mean insertion depth angle (IDA) was 395°. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric–acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions: The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
- 31 October 2019
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 277 (2) , 367-375
Open AccessPreservation of residual hearing after cochlear implant surgery with slim modiolar electrode
Purpose: To evaluate the insertion results and hearing preservation of a novel slim modiolar electrode (SME) in patients with residual hearing. Methods: We retrospectively collected the data from the medical files of 17 patients (18 ears) implanted with a SME. All patients had functional low frequency hearing (PTA (0.125–0.5 kHz) ≤ 80 dB HL). The insertion results were re-examined from the postoperative cone-beam computed tomography scans. Postoperative thresholds were obtained at the time of switch-on of the sound processors (mean 43 days) and at latest follow-up (mean 582 days). The speech recognition in noise was measured with the Finnish matrix sentence test preoperatively and at follow-up. Results: The mean insertion depth angle (IDA) was 395°. Neither scala dislocations nor tip fold over were detected. There were no total hearing losses. Functional low-frequency hearing was preserved in 15/18 (83%) ears at switch-on and in 14/17 (82%) ears at follow-up. According to HEARRING classification, 55% (10/18) had complete HP at switch-on and 41% (7/17) still at follow-up. Thirteen patients (14 ears) were initially fitted with electric–acoustic stimulation and seven patients (8 ears) continued to use it after follow-up. Conclusions: The preliminary hearing preservation results with the SME were more favorable than reported for other perimodiolar electrodes. The results show that the array may also be feasible for electro-acoustic stimulation; it is beneficial in that it provides adequate cochlear coverage for pure electrical stimulation in the event of postoperative or progressive hearing loss.
- 1 December 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (10) , e1019-e1025
The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion
Objectives: To investigate the results of clinical surgical insertions with a Mid-scala array (HIFocus Mid-Scala Electrode, HFms). Study Design: Consecutive retrospective case study. Settings: Tertiary referral center. Patients: Analyses of imaging data of 26 consecutive patients (31 insertions) implanted with the HFms. Intervention (s): The evaluation of insertion trauma evoked by a previously validated image fusion technique. Electrode reconstructions from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) scans to create artifact-free images. Main Outcome Measures: The electrode position was quantified in relation to the basilar membrane. Trauma scaling adopted from Eshraghi was used for evaluating insertion trauma. The results of the visual assessment of the postoperative CBCT were compared to those obtained with the fusion technique. Results: Three insertions had to be excluded due to incompatibility of the imaging data with the fusion software. We found consistent peri- to mid-modiolar placement of the HFms with a mean insertion depth angle of 376°. According to the medical records, a visual examination of the postoperative CBCT indicated that there had been no scala dislocations but when assessed by the image fusion technique, five scala dislocations (17.8%) were found. Additionally, one tip fold-over was detected in the postoperative CBCT even though this was not evident in any intraoperative measurements. Conclusion: HFms showed atraumatic surgical insertion results with consistent mid-modiolar placement. Image fusion enhances the accuracy of the insertion trauma assessment. Routine postoperative imaging is recommended for identifying tip fold-over as well as for quality control and documentation.
- 1 December 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (10) , e1019-e1025
The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion
Objectives: To investigate the results of clinical surgical insertions with a Mid-scala array (HIFocus Mid-Scala Electrode, HFms). Study Design: Consecutive retrospective case study. Settings: Tertiary referral center. Patients: Analyses of imaging data of 26 consecutive patients (31 insertions) implanted with the HFms. Intervention (s): The evaluation of insertion trauma evoked by a previously validated image fusion technique. Electrode reconstructions from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) scans to create artifact-free images. Main Outcome Measures: The electrode position was quantified in relation to the basilar membrane. Trauma scaling adopted from Eshraghi was used for evaluating insertion trauma. The results of the visual assessment of the postoperative CBCT were compared to those obtained with the fusion technique. Results: Three insertions had to be excluded due to incompatibility of the imaging data with the fusion software. We found consistent peri- to mid-modiolar placement of the HFms with a mean insertion depth angle of 376°. According to the medical records, a visual examination of the postoperative CBCT indicated that there had been no scala dislocations but when assessed by the image fusion technique, five scala dislocations (17.8%) were found. Additionally, one tip fold-over was detected in the postoperative CBCT even though this was not evident in any intraoperative measurements. Conclusion: HFms showed atraumatic surgical insertion results with consistent mid-modiolar placement. Image fusion enhances the accuracy of the insertion trauma assessment. Routine postoperative imaging is recommended for identifying tip fold-over as well as for quality control and documentation.
- 24 May 2018
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 275 (7) , 1723-1729
Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones
To evaluate the insertion characteristics and trauma of a new slim lateral wall electrode (SlimJ) in human temporal bones (TB).
- 24 May 2018
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 275 (7) , 1723-1729
Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones
To evaluate the insertion characteristics and trauma of a new slim lateral wall electrode (SlimJ) in human temporal bones (TB).
- 1 October 2017
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 38 (9) , e327-e334
A New Slim Modiolar Electrode Array for Cochlear Implantation: A Radiological and Histological Study
Hypothesis: To explore the results of a new slim modiolar electrode array (SMA) with respect to intracochlear placement and trauma evaluated by detailed radiologic imaging and histology. Background: Hearing and structure preservation is the goal of cochlear implantation for advanced hearing outcomes. Currently, this is most consistently achieved with thin lateral wall electrodes. Modiolar electrodes are located nearer the modiolus and may provide some electrophysiological advantages, but have a greater tendency for causing insertion trauma. Methods: The SMA was implanted in 20 fresh-frozen human temporal bones (TB). All TBs were scanned pre- and postoperatively with cone beam computed tomography. For atraumatic insertion, the round window approach was preferred. Scalar localization and trauma were analyzed by three-dimensional image fusion reconstructions of the pre- and postimplant scans. The TBs underwent histologic examination to validate the radiologic findings. Results: Insertion through the round window was performed in 19 TBs and through a cochleostomy in one TB. In one TB trauma in the form of scala translocation was identified radiologically and histologically. In the remaining TBs there was no insertion trauma. Adequate modiolar localization of the SMA was found in 19 of 20 TBs. The mean angular insertion depth was 400 degrees without correlation to cochlea size. There was no significant statistical difference between the radiological and histological measurements of electrode localization. Conclusion: The SMA showed consistent and atraumatic insertion results in TBs. Pre- and postimplant cone beam computed tomography with image fusion was shown to be very accurate for the assessment of electrode position and insertion trauma.
- 1 October 2017
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 38 (9) , e327-e334
A New Slim Modiolar Electrode Array for Cochlear Implantation: A Radiological and Histological Study
Hypothesis: To explore the results of a new slim modiolar electrode array (SMA) with respect to intracochlear placement and trauma evaluated by detailed radiologic imaging and histology. Background: Hearing and structure preservation is the goal of cochlear implantation for advanced hearing outcomes. Currently, this is most consistently achieved with thin lateral wall electrodes. Modiolar electrodes are located nearer the modiolus and may provide some electrophysiological advantages, but have a greater tendency for causing insertion trauma. Methods: The SMA was implanted in 20 fresh-frozen human temporal bones (TB). All TBs were scanned pre- and postoperatively with cone beam computed tomography. For atraumatic insertion, the round window approach was preferred. Scalar localization and trauma were analyzed by three-dimensional image fusion reconstructions of the pre- and postimplant scans. The TBs underwent histologic examination to validate the radiologic findings. Results: Insertion through the round window was performed in 19 TBs and through a cochleostomy in one TB. In one TB trauma in the form of scala translocation was identified radiologically and histologically. In the remaining TBs there was no insertion trauma. Adequate modiolar localization of the SMA was found in 19 of 20 TBs. The mean angular insertion depth was 400 degrees without correlation to cochlea size. There was no significant statistical difference between the radiological and histological measurements of electrode localization. Conclusion: The SMA showed consistent and atraumatic insertion results in TBs. Pre- and postimplant cone beam computed tomography with image fusion was shown to be very accurate for the assessment of electrode position and insertion trauma.