  • Combined total error in calculated clinical chemistry tests: component analytical error is magnified and decision threshold gray zones widen

    by Alper Gümüş

    Introduction: Calculated tests propagate component analytical errors, yet laboratories monitor only the measured components, rarely the calculated quantity. Methods: Using analytical performance specifications (APSs) from the European Federation of Clinical Chemistry and Laboratory Medicine Biological Variation Database, we propagated bias and imprecision through 5 calculated tests (low-density lipoprotein cholesterol [LDL-C], anion gap, albumin-corrected calcium, the Homeostatic Model Assessment of Insulin Resistance [HOMA-IR], and the De Ritis ratio), representing difference, linear correction, product, and ratio structures. Difference-based and linear-based tests were assessed across clinical scenarios; the ratio was validated by Monte Carlo simulation. Results: At desirable component APSs, the combined total error was 2.1% to 2.8% for albumin-corrected calcium, 25.9% for the De Ritis ratio, and 34% for the HOMA-IR. At typical values, combined errors for LDL-C and the anion gap were 18.5% and 20.8%, respectively, exceeding their respective allowable total error targets (12.0% and 11.3%). Error was concentration dependent: the anion-gap error decreased to 7.4% at 28 mmol/L but increased to 43.0% at 6 mmol/L; the LDL-C error reached 28.6% at 60 mg/dL. The allowable total error–based estimate closely matched the quadrature-bias estimate but underestimated worst-case error. Discussion: Acceptable component performance does not ensure acceptable performance of calculated tests. Derived quantities require specific APSs, and results near clinical decision limits should be interpreted within concentration-dependent analytical gray zones.


  • Clinical implications of galectin-3, N-cadherin, and E-cadherin as potential biomarkers in childhood epilepsy

    by Peren Perk, Arzu Yuksel, Gulsen Sener, Sevinc Mertoglu, Merve Cakmak, Zeynep Oz Dagdelen, Seyda Dogantan, Rahime Koc, Pınar Arıcan, A. Gumus

  • Open Access

    Urinary 5-HIAA as a Potential Diagnostic Marker in Acute Appendicitis: A Preliminary Report of Its Promising Role in Early Detection

    by Murat Demir, Alper Gumus, Huseyin Kilavuz, Feyyaz Gungor, Sibel Yaman, Baki Ekci, Idris Kurtulus

    Background: Acute appendicitis (AA) is a common surgical emergency worldwide. Over the past few decades, diagnostic imaging has become a cornerstone in the identification of acute appendicitis, significantly contributing to the reduction in unnecessary laparotomies and associated healthcare costs. This study aimed to investigate the influence of serum and spot urine 5-hydroxyindoleacetic acid (5-HIAA) levels, as well as other established clinical and biochemical parameters on the diagnosis of acute appendicitis. Methods: This prospective study was conducted between January and November 2023, evaluating 97 patients diagnosed with acute appendicitis. Serum and spot urine 5-HIAA levels, level of white blood cell (WBC), neutrophils, lymphocytes, platelets, C-reactive protein (CRP), and Alvarado score were analyzed. Patients were further allocated to subgroups based on their Alvarado scores, the onset time of the symptoms, and pathological findings to statistically assess the relationship between the parameters. Results: The mean age of the patients was 34.6 ± 14.8 years. Of the patients, 57 (58.8%) were male, and 40 (41.2%) were female. Spot urine 5-HIAA levels exhibited statistically significant variation among different symptom onset time groups, with elevated levels observed in patients presenting within the first 12 h of symptom onset (p < 0.001). Neutrophil counts were significantly different among Alvarado score groups (p < 0.001), whereas CRP levels significantly increased with the onset time of the symptoms (p < 0.001). Conclusions: Increased spot urine 5-HIAA is supportive of the diagnosis of AA in patients presenting within the first 12 h of symptom onset. Hematological parameters, especially CRP, may provide more reliable information regarding disease severity and progression.

  • Open Access

    Statistical insights into ethanol testing: demographic variations and laboratory performance – a core laboratory experience

    by Alper Gümüş, Cihan Coskun, Kamil Taha Uçar, Oğuzhan Zengi, Semih Tek, Bülent Saka, Muhammed Emin Düz, Burak Gümüş, Sümeyye Yılmaz

    Objectives: This study aims to employ statistical methods to analyze 9,521 ethanol tests, performed for clinical and forensic purposes, conducted between 2020 and 2023 at Istanbul Başakşehir Çam and Sakura City Hospital. By assessing the distributions of blood ethanol values across different demographics and laboratory processes, we seek to enrich the literature and provide insights into regional alcohol consumption trends. The data will also cover test turnaround times, rejection rates, and other relevant performance metrics. Methods: Ethanol test results were retrospectively reviewed, covering demographic variables such as age, gender, and positivity rates, as well as laboratory data such as blood ethanol level and test request times. Data handling involved statistical analysis to determine trends and correlations among the tested variables. The blood ethanol levels were analyzed spectrophotometrically using an enzymatic method. Results: The study observed a predominance of male patients (85 %) with an average age of 32 years. Test results indicated a similar positivity rate between genders, around 16.6 % for males and 17 % for females. The concentration of blood ethanol levels is most noticeable at 100–300 mg/dl in individuals who have consumed ethanol. The test rejection rate was 2.5 %, with hemolysis being the most common cause. The total analytical error value was calculated to be 11.4 %. The analysis also revealed significant gender differences in ethanol elimination rates, with males showing a faster decline (16.8 mg/dL/h for females and 20.5 mg/dL/h for males). Conclusions: Our findings underscore the importance of precise and reliable ethanol testing in medical settings, highlighting the impact of test efficiency on patient care and forensic analysis. The study reveals substantial differences in ethanol processing between genders and emphasizes improving test transport and repetition procedures. Ultimately, this research provides valuable contributions to understanding alcohol-related behaviors and enhancing laboratory testing processes in large medical facilities.

  • Open Access

    Assessment of centrifugation knowledge among medical laboratory personnel: a survey-based study

    by Alper Gümüş, Oğuzhan Zengi, Cemal Kazezoğlu, Kamil Taha Uçar, Cihan Coşkun, Semih Tek, Nazife Doğan, Muhammed Emin Düz, Gülsen Şener, Kübra Nur Köyüstü

    This survey study aims to evaluate knowledge of centrifuge operation and adherence to centrifugation protocols among laboratory personnel. These aspects are crucial in preventing pre-analytical errors. Additionally, the study seeks to assess the equipment infrastructure and staffing status within the participants' institutions. The study involved 397 participants from various medical laboratories. A 16-item survey, using a 5-point Likert scale, was utilized to assess theoretical and practical knowledge of centrifuge operation. Two groups of subscales were developed, with one focusing on theoretical and practical knowledge and the other on pre-centrifugation, centrifugation, and post-centrifugation processes. Demographic data were collected, and the reliability of the survey was analyzed using Cronbach's alpha (0.94). Validity was assessed through factor analysis. The majority of participants were female (63%) and worked as laboratory technicians (72%). Approximately 71% had never received formal centrifuge training, and significant differences were observed between theoretical and practical knowledge, particularly among laboratory technicians (P < 0.001). Education level and job title also influenced knowledge scores (P < 0.001). The developed survey scale demonstrated high reliability and validity, indicating its potential as a valuable reference for future studies assessing centrifugation competency and usage in laboratory environments. These findings underline the need for improved training programs to reduce pre-analytical errors and enhance overall laboratory performance.


  • Glucometer versus analyzer: comparable results with negligible clinical risk

    by Alper Gümüş, Cihan Coşkun, Kamil Taha Uçar, İbRahim Erdin, Semih Tek, Betül Evran, Abdulkadir Çat, Oğuzhan Zengi

    This study assessed the reliability of Roche Accu-Chek Inform II glucometers in a real-world setting. A retrospective analysis was conducted on 6,695 paired results. Capillary samples were tested using Roche Accu-Chek Inform II glucometers, while venous samples were analyzed using Roche Cobas c503/702 analyzers. Compliance was assessed using modified criteria based on the ISO 15197 guideline and the CLSI EP09-A3 guideline using Passing-Bablok regression analysis, Bland-Altman plots, and Surveillance Error Grid (SEG) analysis. The overall compliance of glucometer results within +/- 15% or 0.83 mmol/L (15 mg/dL) of the reference method was 81.5%, below the acceptance criterion of 94.6%. SEG analysis showed that 90.3% of the paired results fell within the No-risk zone, with less than 0.001% in the moderate/lower-risk zone. The Emergency Department results indicated 87.8% overall compliance and 92.2% of pairs falling in the No-risk zone. Based on the regression analysis, the glucometer results showed a positive constant bias of nearly 0.33 mmol/L (6 mg/dL). The Bland-Altman plots showed a positive mean difference of 0.43 mmol/L for results <= 5.55 mmol/L (<= 100 mg/dL) and a positive mean percentage difference of 3.77% for results >5.55 mmol/L (>100 mg/dL), within the permissible deviation. The compliance values ranged from 76.0% to 90.3% for clinical concentration groups, with the highest compliance found between >16.65-22.20 mmol/L (>300-400 mg/dL). The Accu-Chek Inform II glucometers demonstrated in real-world reliability, with most results falling within acceptable risk categories. However, compliance still needs improvement, so manufacturers should assess opportunities for advancement.


  • Open Access

    Assessment of blood collection competency in phlebotomists: a survey study

    by Cihan Coşkun, Alper Gümüş, Kamil Taha Uçar, Muhammet Emin Düz, Beyazıt Semih Yeşil, Asibe Özkan, Eda Çiftçi Karan

    Objectives: Blood collection, one of the most frequently performed procedures in healthcare settings. The study aimed to develop a scale for phlebotomy procedures based on national phlebotomy guidelines and to assess the tendencies of phlebotomy personnel in certain blood collection practices. Methods: The survey included a 5-point likert scale, which consisted of 20 items and multiple-choice questions. The survey was disseminated to the attendees via an online platform (Google Forms ® , Mountain View, CA, USA), and they were requested to complete it, and a total of 1,439 participants were included in the study. Results: The data showed that the scale complied with the guidelines and was highly valid and reliable. A significant finding from the study indicates that 47.9 % of the participants (689 individuals) chose the syringe response during the blood collection procedure. The variable of prior phlebotomy training exhibited no statistically significant effect on these responses (χ²=1.893, p=0.093). A statistically significant difference was observed in the frequency of tendencies for using intravenous cannulas/catheters in inpatient settings (p<0.05). Conclusions: The standardization of blood collection practices may be enhanced through the implementation of these procedures by specialized medical professionals. It is necessary to audit the quality of current practices and identify the most vulnerable steps in phlebotomy. The implementation of phlebotomy guidelines in healthcare settings should be encouraged. Furthermore, greater commitment is required from relevant authorities to develop educational programs and establish continuous education courses for healthcare phlebotomy personnel.


  • Open Access

    Impact of CD40 (rs1883832) and CD40L (rs1126535) gene variants on laryngeal cancer susceptibility and their association with serum biomarker levels of sCD40 and sCD40L

    by Alper Gümüş, Dilara Sönmez, Şeyda Demirkol, Mehmet Tolgahan Hakan, Ayşegül Verim, Yusufhan Süoğlu, İlhan Yaylım, Arzu Ergen

    Introduction: The most prevalent head and neck cancer type is laryngeal cancer. Laryngeal cancer susceptibility is increased by a combination of genetic variables and environmental factors. Genetic predispositions that influence the functioning of the immune system can affect tumor development. Our study investigates the impact of alterations in CD40 (rs1883832) and CD40L (rs1126535) genes and the levels of their proteins on the development of laryngeal cancer. Materials and methods: The PCR-RFLP method was used for genotyping SNPs in 96 patients with laryngeal cancer and 127 healthy individuals. Additionally, ELISA was utilized to measure circulating levels of sCD40 and sCD40L. Results: We identified a significant difference in the genotype distribution of CD40 (rs1883832) between laryngeal cancer patients and healthy individuals (p = 0.05). The C allele was dominant, and the CC genotype was more frequently observed in patients with laryngeal cancer (OR: 2.34, 95% CI: 0.98–5.54). In contrast, no statistically significant difference in the genotypes of CD40L (rs1126535) was detected between laryngeal cancer patients and the control group (p = 0.12). Additionally, no significant differences in serum sCD40 or sCD40L levels were observed between the groups (p = 0.48 and p = 0.15, respectively). However, a moderate positive correlation was found between sCD40 and sCD40L levels in the laryngeal cancer group (r = 0.52, p<0.01), a relationship that was not observed in the control group. Discussion: According to the current findings, it is suggested that the CD40 (rs1883832) gene variation found in patients may indicate an individual’s susceptibility to developing laryngeal cancer. On the other hand, CD40L (rs1126535) seems to not play a significant role. While serum sCD40 and sCD40L levels did not show significant differences between patients and controls, the correlation in cancer patients suggests that these markers may be relevant in tumor progression. Further research is required to clarify the functional implications of these genetic variants and their potential use as biomarkers for laryngeal cancer.


  • Open Access

    Assessment of Centrifuge Knowledge Among Medical Laboratory Personnel: A Survey-Based Study

    by Alper Gümüş, Oğuzhan Zengi, Cemal Kazezoğlu, Kamil Taha Uçar, Cihan Coşkun, Semih Tek, Nazife Doğan, Muhammed Emin Düz, Gülsen Şener, Kübra Nur Köyüstü

    Objective: This survey study aims to evaluate knowledge of centrifuge usage and adherence to centrifugation protocols among laboratory personnel. These aspects are crucial in preventing pre-analytical errors. Additionally, the study seeks to assess the equipment infrastructure and staffing status within the participants' institutions. Materials and methods:The study involved 397 participants from various medical laboratories. A 16-item survey, using a 5-point Likert scale, was utilized to assess theoretical and practical knowledge of centrifuge usage. Two groups of subscales were developed, with one focusing on theoretical and practical knowledge and the other on pre-centrifugation, centrifugation, and post-centrifugation processes. Demographic data were collected, and the reliability of the survey was analyzed using Cronbach's alpha (0.94). Validity was assessed through factor analysis. Results: The majority of participants were female (63%) and worked as laboratory technicians (72%). Approximately 71% had never received formal centrifuge training, and significant differences were observed between theoretical and practical knowledge, particularly among laboratory technicians (P<0.001). Education level and job title also influenced knowledge scores (P<0.001). Conclusion: The developed survey scale demonstrated high reliability and validity, indicating its potential as a valuable reference for future studies assessing centrifuge knowledge and usage in laboratory environments. These findings underline the need for improved training programs to reduce pre-analytical errors and enhance overall laboratory performance.