Lane C. Sander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lane C. Sander has a total of 133 co-authors. Here are the top co-authors by number of shared publications:
- Katherine E. Sharpless
National Institute of Standards and Technology
11 shared publications Stephen A. Wise
National Institute of Standards and Technology (NIST) , Chemical Sciences Division, 100 Bureau Drive, MS 8392, Gaithersburg, Maryland 20899-8392, United States
11 shared publications- Michele M. Schantz
Chemical Sciences Division, National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA,
9 shared publications - Stephen A. Wise
Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
7 shared publications - Karen W. Phinney
Biomolecular Measurement Division, Material Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, USA
4 shared publications Dianne L. Poster
Analytical Chemistry Division , National Institute of Standards and Technology , Gaithersburg , Maryland , USA
3 shared publications
Latest Publications
- 28 February 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (4) , 299-305
Separations by Shape: Molecular Shape Recognition in Liquid Chromatography
Molecular shape can provide a basis for chromatographic separations that is distinct from other interaction mechanisms often considered in liquid chromatography. Molecular shape recognition, or shape selectivity, is most evident for the separation of isomeric compounds that have constrained molecular structures, such as polycyclic aromatic hydrocarbons. A central feature of shape-selective columns is conformational order within the stationary phase; this aspect of stationary phase morphology is revealed through spectroscopic studies and molecular dynamics simulations, and is correlated with chromatographic performance.
- 28 February 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (4) , 299-305
Separations by Shape: Molecular Shape Recognition in Liquid Chromatography
Molecular shape can provide a basis for chromatographic separations that is distinct from other interaction mechanisms often considered in liquid chromatography. Molecular shape recognition, or shape selectivity, is most evident for the separation of isomeric compounds that have constrained molecular structures, such as polycyclic aromatic hydrocarbons. A central feature of shape-selective columns is conformational order within the stationary phase; this aspect of stationary phase morphology is revealed through spectroscopic studies and molecular dynamics simulations, and is correlated with chromatographic performance.
- 26 November 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1614, 460732
Characterization of triacontyl (C-30) liquid chromatographic columns
- 26 November 2019
- Published by Elsevier in Journal of Chromatography A
- Vol. 1614, 460732
Characterization of triacontyl (C-30) liquid chromatographic columns
- 2 October 2019
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 124, 1
Calibration
In the context of chemical metrology, calibration is the process of relating a known quantity of an analyte to the corresponding measured instrumental response through a mathematical relationship. Calibration permits the assignment of analyte levels in unknown samples based on the known levels of the calibrants. Details of the calibration model are important to achieve accurate results. Several common approaches are used in calibrating methods. Most frequently, calibration models are based on linear instrumental response, with mathematical models that include zero intercept, fixed intercept, unconstrained (fitted), and bracketed models. When instrumental response is nonlinear, a linear model may still provide accurate results if the calibration range is sufficiently limited. This presentation will provide an overview and application of various calibration models, with recommendations of ways to improve measurement accuracy. Examples are presented that illustrate advantages and disadvantages for each of these models as applied to low level samples and to unknowns with levels that span several orders of magnitude.
- 2 October 2019
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 124, 1
Calibration
In the context of chemical metrology, calibration is the process of relating a known quantity of an analyte to the corresponding measured instrumental response through a mathematical relationship. Calibration permits the assignment of analyte levels in unknown samples based on the known levels of the calibrants. Details of the calibration model are important to achieve accurate results. Several common approaches are used in calibrating methods. Most frequently, calibration models are based on linear instrumental response, with mathematical models that include zero intercept, fixed intercept, unconstrained (fitted), and bracketed models. When instrumental response is nonlinear, a linear model may still provide accurate results if the calibration range is sufficiently limited. This presentation will provide an overview and application of various calibration models, with recommendations of ways to improve measurement accuracy. Examples are presented that illustrate advantages and disadvantages for each of these models as applied to low level samples and to unknowns with levels that span several orders of magnitude.
- 1 November 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1574, 114-121
Method development for the certification of a ginsenoside calibration solution via liquid chromatography with absorbance and mass spectrometric detection
- 1 November 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1574, 114-121
Method development for the certification of a ginsenoside calibration solution via liquid chromatography with absorbance and mass spectrometric detection
- 20 September 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (19) , 10461-10467
Development of a Cigarette Tobacco Filler Standard Reference Material
A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.
- 20 September 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (19) , 10461-10467
Development of a Cigarette Tobacco Filler Standard Reference Material
A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.
- 8 March 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1
Solid Phase Extraction
- 8 March 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1
Solid Phase Extraction
- 12 January 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1
What is Chromatography All About?
- 12 January 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1
What is Chromatography All About?