Shonali Nazare
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shonali Nazare has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Maranghides
Department of Commerce Technology Administration Building and Fire Research Laboratory National Institute of Standards And Technology Gaithersburg, MD 20899
5 shared publications - Erik Johnsson
National Institute of Standards and Technology
4 shared publications - Kathryn Butler
National Institute of Standards and Technology . Technology Administration . U.S. Deportment of Commerce
4 shared publications - Marco Fernandez3 shared publications
- William M. Pitts
Fire Research Division, Engineering Laboratory National Institute of Standards and Technology Gaithersburg Maryland USA
3 shared publications - Eric D. Link
National Institute of Standards and Technology
2 shared publications
Latest Publications
- 26 November 2025
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from composite fences
Field observations show that combustible landscaping features are a common pathway leading fire spread directly to homes during wildland-urban interface (WUI) fires. NIST is studying how these features near a home burn to better understand their levels of hazard and potential roles in spreading WUI fires. Following up on an earlier NIST study involving a variety of fences and mulch, full-scale fire experiments and cone calorimeter tests were conducted on two types of wood-plastic composite (WPC) fences and one steel-plastic composite (SPC) fence available to consumers. Full-scale experiments examined the effects on fire spread toward a structure for each type of composite fence, with and without shredded hardwood mulch placed beneath the fence. A wind machine provided a nominal mean wind speed of 6 m/s (13 mi/h). The fence and/or mulch bed were ignited by a propane burner on the ground at the end farthest from the structure. A small structure was located 1.83 m (6 ft) downwind of the fence as a target for flames and firebrands. A target mulch bed at the base of the structure tested the ability of firebrands or flames produced by the burning fence and mulch bed to ignite spot fires that threatened the structure. Cone calorimeter tests were performed on samples from all three composite fences and compared to previous results from western red cedar and vinyl privacy fences. Ignitability and flammability measurements were obtained in horizontal and vertical orientations according to standard cone calorimeter protocols described in ASTM E-1354. Full-scale experiments showed severe fire behavior from two of the three composite fences, with flames extending above and well downwind of the fence even in the absence of mulch beneath. For one WPC fence, the upper frame distorted in the fire, allowing burning vertical boards to fall to each side of the fence and creating a burning zone along the fence path whose width was twice the fence height. The SPC fence melted and dripped, resulting in large flames and hanging strands of plastic blown by the wind field. The fire behavior of the second WPC fence was less severe, attributed primarily to its horizontal board design. As the fire near the ground consumed each horizontal board in turn, the boards above it slipped downward within the frame. As a result, the flame height stayed below the halfway point on the fence, the burning boards remained close to the centerline of the fence as they fell to the ground, and the fire diminished on its own as it ran low on fuel. In the absence of mulch, this fence burned slowly in a hole near the ignition site, with glowing combustion and occasional small flames. Findings from the cone calorimeter in a vertical configuration complemented full-scale experiments. Melting and dripping or slipping of the sample surface contributed to large peak heat release rates for the two composite fences with intense full-scale fire behavior. For all three composite fence samples, the effective heat of combustion was much higher than for wood or vinyl. Recommendations include developing fire test(s) for evaluating fences and fence materials that represent the actual fire hazard and avoiding very high hazard composite fences. This study of fire spread over composite fences is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- 26 November 2025
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from composite fences
Field observations show that combustible landscaping features are a common pathway leading fire spread directly to homes during wildland-urban interface (WUI) fires. NIST is studying how these features near a home burn to better understand their levels of hazard and potential roles in spreading WUI fires. Following up on an earlier NIST study involving a variety of fences and mulch, full-scale fire experiments and cone calorimeter tests were conducted on two types of wood-plastic composite (WPC) fences and one steel-plastic composite (SPC) fence available to consumers. Full-scale experiments examined the effects on fire spread toward a structure for each type of composite fence, with and without shredded hardwood mulch placed beneath the fence. A wind machine provided a nominal mean wind speed of 6 m/s (13 mi/h). The fence and/or mulch bed were ignited by a propane burner on the ground at the end farthest from the structure. A small structure was located 1.83 m (6 ft) downwind of the fence as a target for flames and firebrands. A target mulch bed at the base of the structure tested the ability of firebrands or flames produced by the burning fence and mulch bed to ignite spot fires that threatened the structure. Cone calorimeter tests were performed on samples from all three composite fences and compared to previous results from western red cedar and vinyl privacy fences. Ignitability and flammability measurements were obtained in horizontal and vertical orientations according to standard cone calorimeter protocols described in ASTM E-1354. Full-scale experiments showed severe fire behavior from two of the three composite fences, with flames extending above and well downwind of the fence even in the absence of mulch beneath. For one WPC fence, the upper frame distorted in the fire, allowing burning vertical boards to fall to each side of the fence and creating a burning zone along the fence path whose width was twice the fence height. The SPC fence melted and dripped, resulting in large flames and hanging strands of plastic blown by the wind field. The fire behavior of the second WPC fence was less severe, attributed primarily to its horizontal board design. As the fire near the ground consumed each horizontal board in turn, the boards above it slipped downward within the frame. As a result, the flame height stayed below the halfway point on the fence, the burning boards remained close to the centerline of the fence as they fell to the ground, and the fire diminished on its own as it ran low on fuel. In the absence of mulch, this fence burned slowly in a hole near the ignition site, with glowing combustion and occasional small flames. Findings from the cone calorimeter in a vertical configuration complemented full-scale experiments. Melting and dripping or slipping of the sample surface contributed to large peak heat release rates for the two composite fences with intense full-scale fire behavior. For all three composite fence samples, the effective heat of combustion was much higher than for wood or vinyl. Recommendations include developing fire test(s) for evaluating fences and fence materials that represent the actual fire hazard and avoiding very high hazard composite fences. This study of fire spread over composite fences is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- 16 April 2025
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from landscape timbers
NIST is studying how combustible landscape features around a home burn to better understand their levels of hazard and potential roles in spreading wildland-urban interface (WUI) fires. A series of field experiments was conducted to examine the effects of landscape timbers on fire spread toward a structure under conditions that may be encountered during a WUI fire. The fire behavior of landscape timbers in multiple configurations was studied under various wind conditions. Fifteen experiments were conducted. Landscape timber types included pressure-treated rounded 7.0 cm x 8.9 cm (2.75 in x 3.5 in) pine timbers, pressure-treated 14.0 cm x 14.0 cm (5.5 in x 5.5 in) pine lumber, and creosote-treated 17.8 cm (7 in) by 22.9 cm (9 in) railroad ties. Configuration variations included the number of timbers vertically stacked, the presence of mulch, orientation, and use as a retaining wall. A wind machine provided a mean wind speed of nominally 6 m/s (13 mi/h) for most experiments. Timbers were ignited by a propane burner on the ground at the end farthest from a small structure located 1.83 m (6 ft) downwind of the trailing end of the timber. For most experiments, a target mulch bed at the base of the structure evaluated the ability of firebrands produced by the burning landscape timbers to ignite spot fires that could threaten the structure. A final experiment compared burning behavior of a stack of timbers in the open compared to one used as a retaining wall. The experiments in this study demonstrated that landscape timbers can be sources of spot fire ignitions and can spread fire to nearby structures. Fire behavior was classified as medium hazard for moderate fire spread rates along timbers and igniting spot fires under all wind conditions. Spot fire generation was affected by the wind field; the structure created both upward flow (enhanced by buoyancy) and a vortex that deposited firebrands next to the structure. During most but not all experiments, the burning landscape timbers, sometimes with a burning mulch bed, produced firebrands that ignited spot fires in the target mulch bed. This study of the fire hazard of landscape timbers is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- 16 April 2025
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from landscape timbers
NIST is studying how combustible landscape features around a home burn to better understand their levels of hazard and potential roles in spreading wildland-urban interface (WUI) fires. A series of field experiments was conducted to examine the effects of landscape timbers on fire spread toward a structure under conditions that may be encountered during a WUI fire. The fire behavior of landscape timbers in multiple configurations was studied under various wind conditions. Fifteen experiments were conducted. Landscape timber types included pressure-treated rounded 7.0 cm x 8.9 cm (2.75 in x 3.5 in) pine timbers, pressure-treated 14.0 cm x 14.0 cm (5.5 in x 5.5 in) pine lumber, and creosote-treated 17.8 cm (7 in) by 22.9 cm (9 in) railroad ties. Configuration variations included the number of timbers vertically stacked, the presence of mulch, orientation, and use as a retaining wall. A wind machine provided a mean wind speed of nominally 6 m/s (13 mi/h) for most experiments. Timbers were ignited by a propane burner on the ground at the end farthest from a small structure located 1.83 m (6 ft) downwind of the trailing end of the timber. For most experiments, a target mulch bed at the base of the structure evaluated the ability of firebrands produced by the burning landscape timbers to ignite spot fires that could threaten the structure. A final experiment compared burning behavior of a stack of timbers in the open compared to one used as a retaining wall. The experiments in this study demonstrated that landscape timbers can be sources of spot fire ignitions and can spread fire to nearby structures. Fire behavior was classified as medium hazard for moderate fire spread rates along timbers and igniting spot fires under all wind conditions. Spot fire generation was affected by the wind field; the structure created both upward flow (enhanced by buoyancy) and a vortex that deposited firebrands next to the structure. During most but not all experiments, the burning landscape timbers, sometimes with a burning mulch bed, produced firebrands that ignited spot fires in the target mulch bed. This study of the fire hazard of landscape timbers is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- 10 July 2024
- Published by National Institute of Standards and Technology (NIST)
Preliminary field burns of RV trailers with external ignitions
Two recreational vehicle (RV) travel trailers were burned outdoors at the Austin Fire Department training campus in Austin, TX. The goal of these preliminary experiments was to observe and document the burning behavior of fully furnished RV trailers and to assess the feasibility of future instrumented burns in the National Fire Research Laboratory. Burning parcel-level combustibles can produce significant thermal exposures to surrounding combustibles, often leading to fire spread beyond the object of origin. In wildland-urban interface (WUI) fires, this scenario often perpetuates fire spread leading to destruction further into a community. For these field burns, the RV trailers were ignited from the exterior, representing a WUI fire scenario where a parcel-level combustible ignites and becomes an exposure source, producing an enhanced fire spread pathway to other nearby combustibles or primary structures. The RV trailers were 6.7 m (22 ft) long and were equipped with basic factory-installed furnishings. Videos of the burns were recorded from multiple angles to document visual observations of fire behavior and flame lengths. The primary burning period of each trailer ranged from 13 min to 17 min. Maximum flame lengths were approximately 10 m (30 ft). Observations from the field burns present some concerns about the size of the fire for potential indoor laboratory study. The burns were conducted in collaboration with the Austin Fire Department, U.S. Fire Administration, Federal Emergency Management Agency, and the U.S. Consumer Product Safety Commission.
- 10 July 2024
- Published by National Institute of Standards and Technology (NIST)
Preliminary field burns of RV trailers with external ignitions
Two recreational vehicle (RV) travel trailers were burned outdoors at the Austin Fire Department training campus in Austin, TX. The goal of these preliminary experiments was to observe and document the burning behavior of fully furnished RV trailers and to assess the feasibility of future instrumented burns in the National Fire Research Laboratory. Burning parcel-level combustibles can produce significant thermal exposures to surrounding combustibles, often leading to fire spread beyond the object of origin. In wildland-urban interface (WUI) fires, this scenario often perpetuates fire spread leading to destruction further into a community. For these field burns, the RV trailers were ignited from the exterior, representing a WUI fire scenario where a parcel-level combustible ignites and becomes an exposure source, producing an enhanced fire spread pathway to other nearby combustibles or primary structures. The RV trailers were 6.7 m (22 ft) long and were equipped with basic factory-installed furnishings. Videos of the burns were recorded from multiple angles to document visual observations of fire behavior and flame lengths. The primary burning period of each trailer ranged from 13 min to 17 min. Maximum flame lengths were approximately 10 m (30 ft). Observations from the field burns present some concerns about the size of the fire for potential indoor laboratory study. The burns were conducted in collaboration with the Austin Fire Department, U.S. Fire Administration, Federal Emergency Management Agency, and the U.S. Consumer Product Safety Commission.
- 20 May 2024
- Published by National Institute of Standards and Technology (NIST)
NIST eave and vent experiments (EaVE) EaVEs phase A :
This test plan documents experiments that are part of ongoing research to assess structure-to-structure fire spread in the Wildland-Urban Interface (WUI). Previous indoor and outdoor full-scale experiments were conducted with varying distance between sheds and the exterior wall of a primary residence. The current experiments were planned to understand the failure of the eave vents used in previous experiments. The objective of these full-scale experiments is to characterize the performance of representative eave vents exposed to fire from the source structure. Metal sheds of varying sizes and fuel loads (wood cribs) will be burned under the 20 MW exhaust hood in the National Fire Research Laboratory (NFRL) at the National Institute of Standards and Technology (NIST) at varying structure separation distances (SSDs) from the target structure. The target structure includes an assembly of an exterior wall, a roof, and an eave vent. A range of measurements will be taken during the experiments including heat release rate, heat flux, temperature, gas flow velocity, and gas species concentration using open-path absorption spectroscopy. Video and infrared cameras will record the experiments. A separate NIST Technical Note will report the results of these experiments.
- 20 May 2024
- Published by National Institute of Standards and Technology (NIST)
NIST eave and vent experiments (EaVE) EaVEs phase A :
This test plan documents experiments that are part of ongoing research to assess structure-to-structure fire spread in the Wildland-Urban Interface (WUI). Previous indoor and outdoor full-scale experiments were conducted with varying distance between sheds and the exterior wall of a primary residence. The current experiments were planned to understand the failure of the eave vents used in previous experiments. The objective of these full-scale experiments is to characterize the performance of representative eave vents exposed to fire from the source structure. Metal sheds of varying sizes and fuel loads (wood cribs) will be burned under the 20 MW exhaust hood in the National Fire Research Laboratory (NFRL) at the National Institute of Standards and Technology (NIST) at varying structure separation distances (SSDs) from the target structure. The target structure includes an assembly of an exterior wall, a roof, and an eave vent. A range of measurements will be taken during the experiments including heat release rate, heat flux, temperature, gas flow velocity, and gas species concentration using open-path absorption spectroscopy. Video and infrared cameras will record the experiments. A separate NIST Technical Note will report the results of these experiments.
- 30 March 2023
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from firewood piles
A series of field experiments was conducted to examine the effects on fire spread toward a structure for firewood piles under conditions that may be encountered in a wildland-urban interface (WUI) fire. The fire behavior of a variety of firewood types in multiple configurations was studied under various wind conditions. The 62 experiments conducted included long range firebrand travel and mitigation experiments. Wood types included kiln-dried oak, maple, pine, and undried oak. Configuration variations included woodpile height, orientation, and elevation on a rack. A wind machine provided a mean wind speed between 6 m/s and 14 m/s (13 mi/h to 31 mi/h). The woodpiles were ignited by a propane burner on the ground at the end farthest from a small structure located between 0 m and 7.32 m (0 ft to 24 ft) downwind of the woodpile. A target mulch bed at the base of the structure tested the ability of firebrands produced by the burning woodpile to ignite spot fires that threatened the structure. The experiments in this study demonstrated that firewood piles can be rapid sources of spot fire ignitions and can easily spread fire to nearby structures. Rapid fire growth on and substantial flames from the woodpiles were found for all wood types and configurations. Fire behavior was classified as mostly high with medium hazard for only the lowest wind condition. In all cases, spot fire generation was affected by the wind field; the structure created both upward flow (enhanced by buoyancy) and a vortex that deposited firebrands next to the structure. During all experiments, the burning woodpile produced firebrands that ignited spot fires in the target mulch bed. In long range experiments, firebrands from a woodpile caused ignitions over 26 m (85 ft) downwind. This study of the fire hazard of woodpiles is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- 30 March 2023
- Published by National Institute of Standards and Technology (NIST)
Wind-driven fire spread to a structure from firewood piles
A series of field experiments was conducted to examine the effects on fire spread toward a structure for firewood piles under conditions that may be encountered in a wildland-urban interface (WUI) fire. The fire behavior of a variety of firewood types in multiple configurations was studied under various wind conditions. The 62 experiments conducted included long range firebrand travel and mitigation experiments. Wood types included kiln-dried oak, maple, pine, and undried oak. Configuration variations included woodpile height, orientation, and elevation on a rack. A wind machine provided a mean wind speed between 6 m/s and 14 m/s (13 mi/h to 31 mi/h). The woodpiles were ignited by a propane burner on the ground at the end farthest from a small structure located between 0 m and 7.32 m (0 ft to 24 ft) downwind of the woodpile. A target mulch bed at the base of the structure tested the ability of firebrands produced by the burning woodpile to ignite spot fires that threatened the structure. The experiments in this study demonstrated that firewood piles can be rapid sources of spot fire ignitions and can easily spread fire to nearby structures. Rapid fire growth on and substantial flames from the woodpiles were found for all wood types and configurations. Fire behavior was classified as mostly high with medium hazard for only the lowest wind condition. In all cases, spot fire generation was affected by the wind field; the structure created both upward flow (enhanced by buoyancy) and a vortex that deposited firebrands next to the structure. During all experiments, the burning woodpile produced firebrands that ignited spot fires in the target mulch bed. In long range experiments, firebrands from a woodpile caused ignitions over 26 m (85 ft) downwind. This study of the fire hazard of woodpiles is part of a series designed to better inform standards and codes regarding placement of landscape features around homes that are at risk of exposure to wildland-urban interface fires.
- Open Access
- 23 July 2019
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 37 (4-6) , 340-376
Assessing fire-blocking effectiveness of barrier fabrics in the cone calorimeter
Cone calorimetry experiments of on flexible polyurethane foam and flexible polyurethane foam covered with a variety of fire-blocking barrier fabrics were used to characterize and rank the effectiveness of barrier fabrics with the ultimate goal being an ability to predict the effectiveness of barrier fabrics for reducing the flammability of residential upholstered furniture. The primary measure used to characterize the burning behavior was heat release rate. The effect of the underlying sample substrate was shown to have a large effect on the burning behavior of flexible polyurethane foam samples, and a thermally insulating substrate was used during composite experiments. At times, rapid heat release rate fluctuations were observed, and in such cases approximate corrections were applied to correct for finite cone calorimeter time response. Measurements using thermocouples placed within the flexible polyurethane foam provided insights on flexible polyurethane foam pyrolysis behavior, the collapse rate of flexible polyurethane foam, and the thermal protective properties of barrier materials. Heat release rate temporal profiles for flexible polyurethane foam showed two distinct burning stages with peak values which have been attributed to sequential burning of species (primarily) derived from the diamine ( PHRR1) and polyol components ( PHRR2) used to manufacture the flexible polyurethane foam. When a barrier fabric was added, many of the composites displayed a three-stage burning behavior which was attributed to an initial short, intense burning (termed flash burning) stage associated with the barrier fabric covering followed by the two flexible polyurethane foam stages. Seven out of 16 flexible polyurethane foam/barrier fabric composites exhibited flame extinction prior to fuel burn out. Five out of the seven composites reignited when the spark ignition source was reapplied. Reignition allowed barrier fabric effectiveness to be assessed even for cases with flame extinction. Barrier fabric performance was shown to be consistent with four properties that were previously identified as important barrier fabric properties: barrier fabric flammability, gas permeability, thermal protection, and physical integrity. In addition, the current experiments indicate the presence and effectiveness of gas-phase active flame retardants in the barrier fabric can also play an important role. A limited number of tests were conducted to de-couple the effects of flame-retardant chemicals and physical effects of barrier fabrics on flexible polyurethane foam burning behavior. These tests showed that while flame-retardant chemicals can be effective in quenching and extinguishing the flames, the presence of effective barrier fabric shells is also very important in lowering the heat release rate of burning flexible polyurethane foam. In general, the presence of a barrier fabric was shown to reduce the heat release rate peak values during both flexible polyurethane foam burning stages. The magnitude of the peak associated with second-stage flexible polyurethane foam burning was deemed the most appropriate for characterizing the thermal protection provided by a barrier fabric. Since the times for PHRR2 also varied between composites, a measurement referred to as the peak fire growth rate (PFIGRA) parameter was calculated by dividing the heat release rate by time since time to ignition and PFIGRA2 was also considered for characterizing the barrier fabrics. Three possible classification schemes, each consisting of three classes, were introduced based on composite flame extinction and reignition behavior, PHRR2 values, and PFIGRA2 values. Each scheme provided differentiation between barrier fabric effectiveness. While the schemes were able to assess whether the barrier fabrics were particularly effective or ineffective, there were variations among classes of barrier fabrics having intermediate levels of effectiveness. Further work will be required to assess which, if any, of the classification schemes are most appropriate for predicting barrier fabric performance in residential upholstered furniture.
- 23 July 2019
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 37 (4-6) , 340-376
Open AccessAssessing fire-blocking effectiveness of barrier fabrics in the cone calorimeter
Cone calorimetry experiments of on flexible polyurethane foam and flexible polyurethane foam covered with a variety of fire-blocking barrier fabrics were used to characterize and rank the effectiveness of barrier fabrics with the ultimate goal being an ability to predict the effectiveness of barrier fabrics for reducing the flammability of residential upholstered furniture. The primary measure used to characterize the burning behavior was heat release rate. The effect of the underlying sample substrate was shown to have a large effect on the burning behavior of flexible polyurethane foam samples, and a thermally insulating substrate was used during composite experiments. At times, rapid heat release rate fluctuations were observed, and in such cases approximate corrections were applied to correct for finite cone calorimeter time response. Measurements using thermocouples placed within the flexible polyurethane foam provided insights on flexible polyurethane foam pyrolysis behavior, the collapse rate of flexible polyurethane foam, and the thermal protective properties of barrier materials. Heat release rate temporal profiles for flexible polyurethane foam showed two distinct burning stages with peak values which have been attributed to sequential burning of species (primarily) derived from the diamine ( PHRR1) and polyol components ( PHRR2) used to manufacture the flexible polyurethane foam. When a barrier fabric was added, many of the composites displayed a three-stage burning behavior which was attributed to an initial short, intense burning (termed flash burning) stage associated with the barrier fabric covering followed by the two flexible polyurethane foam stages. Seven out of 16 flexible polyurethane foam/barrier fabric composites exhibited flame extinction prior to fuel burn out. Five out of the seven composites reignited when the spark ignition source was reapplied. Reignition allowed barrier fabric effectiveness to be assessed even for cases with flame extinction. Barrier fabric performance was shown to be consistent with four properties that were previously identified as important barrier fabric properties: barrier fabric flammability, gas permeability, thermal protection, and physical integrity. In addition, the current experiments indicate the presence and effectiveness of gas-phase active flame retardants in the barrier fabric can also play an important role. A limited number of tests were conducted to de-couple the effects of flame-retardant chemicals and physical effects of barrier fabrics on flexible polyurethane foam burning behavior. These tests showed that while flame-retardant chemicals can be effective in quenching and extinguishing the flames, the presence of effective barrier fabric shells is also very important in lowering the heat release rate of burning flexible polyurethane foam. In general, the presence of a barrier fabric was shown to reduce the heat release rate peak values during both flexible polyurethane foam burning stages. The magnitude of the peak associated with second-stage flexible polyurethane foam burning was deemed the most appropriate for characterizing the thermal protection provided by a barrier fabric. Since the times for PHRR2 also varied between composites, a measurement referred to as the peak fire growth rate (PFIGRA) parameter was calculated by dividing the heat release rate by time since time to ignition and PFIGRA2 was also considered for characterizing the barrier fabrics. Three possible classification schemes, each consisting of three classes, were introduced based on composite flame extinction and reignition behavior, PHRR2 values, and PFIGRA2 values. Each scheme provided differentiation between barrier fabric effectiveness. While the schemes were able to assess whether the barrier fabrics were particularly effective or ineffective, there were variations among classes of barrier fabrics having intermediate levels of effectiveness. Further work will be required to assess which, if any, of the classification schemes are most appropriate for predicting barrier fabric performance in residential upholstered furniture.
- Open Access
Factors for Consideration in an Open-Flame Test for Assessing Fire Blocking Performance of Barrier Fabrics
The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.
Open AccessFactors for Consideration in an Open-Flame Test for Assessing Fire Blocking Performance of Barrier Fabrics
The main objective of the work reported here is to assess factors that could affect the outcome of a proposed open flame test for barrier fabrics (BF-open flame test). The BF-open flame test characterizes barrier effectiveness by monitoring the ignition of a flexible polyurethane foam (FPUF) layer placed in contact with the upper side of the barrier fabric, exposed to a burner flame from below. Particular attention is given to the factors that influence the ignitibility of the FPUF, including thermal resistance, permeability, and structural integrity of the barrier fabrics (BFs). A number of barrier fabrics, displaying a wide range of the properties, are tested with the BF-open flame test. Visual observations of the FPUF burning behavior and BF char patterns, in addition to heat flux measurements on the unexposed side of the barrier fabrics, are used to assess the protective performance of the BF specimen under the open flame test conditions. The temperature and heat transfer measurements on the unexposed side of the BF and subsequent ranking of BFs for their thermal protective performance suggest that the BF-open flame test does not differentiate barrier fabrics based on their heat transfer properties. A similar conclusion is reached with regard to BF permeability characterized at room temperature. However, the outcome of this BF-open flame test is found to be heavily influenced by the structural integrity of thermally degraded BF. The BF-open flame test, in its current form, only ignited FPUF when structural failure of the barrier was observed.
- Open Access
- 1 January 2015
- Published by National Institute of Standards and Technology (NIST)
Resulets of barrier fabrics tested in an inverted configuration
- 1 January 2015
- Published by National Institute of Standards and Technology (NIST)
Open AccessResulets of barrier fabrics tested in an inverted configuration
- 31 October 2013
- Published by Wiley in Fire and Materials
- Vol. 38 (7) , 695-716
Evaluating fire blocking performance of barrier fabrics
SUMMARY: A series of evaluations were performed on different types of barrier fabrics (BFs) used in soft furnishings. Fundamental properties that influence the heat transfer characteristics of barrier material as it relates to thermal protection of cushioning components in upholstered products are discussed. This is important to enable a priori selection of BFs such that a final upholstered product complies with flammability regulations.Heat transfer measurements are used to determine effectiveness of materials to be used as barrier materials. A new bench‐scale composite test method is also described to assess qualitative fire blocking performance of BFs. When tested for heat transfer characteristics, the area density and thickness of BFs show strong influence. However, when tested as a composite in a mock‐up assembly, the BFs considered in this study showed a clear distinction between active and passive BFs. In the case of chemically active BFs, the construction parameters and material properties such as thickness, air permeability, and heat transfer were of little significance. In the case of passive BFs, however, these parameters became decisive. Results from this study suggest that if the BF is not an active fire barrier, then the amount of heat transferred through BF is critical. Copyright © 2013 John Wiley & Sons, Ltd.
- 31 October 2013
- Published by Wiley in Fire and Materials
- Vol. 38 (7) , 695-716
Evaluating fire blocking performance of barrier fabrics
SUMMARY: A series of evaluations were performed on different types of barrier fabrics (BFs) used in soft furnishings. Fundamental properties that influence the heat transfer characteristics of barrier material as it relates to thermal protection of cushioning components in upholstered products are discussed. This is important to enable a priori selection of BFs such that a final upholstered product complies with flammability regulations.Heat transfer measurements are used to determine effectiveness of materials to be used as barrier materials. A new bench‐scale composite test method is also described to assess qualitative fire blocking performance of BFs. When tested for heat transfer characteristics, the area density and thickness of BFs show strong influence. However, when tested as a composite in a mock‐up assembly, the BFs considered in this study showed a clear distinction between active and passive BFs. In the case of chemically active BFs, the construction parameters and material properties such as thickness, air permeability, and heat transfer were of little significance. In the case of passive BFs, however, these parameters became decisive. Results from this study suggest that if the BF is not an active fire barrier, then the amount of heat transferred through BF is critical. Copyright © 2013 John Wiley & Sons, Ltd.