Brian Peter Lucas
Brian Peter Lucas has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Kevin Schott
VA Pittsburgh Healthcare Sciences and University of Pittsburgh
3 shared publications - Jeremy S. Boyd
Department of Emergency Medicine, Vanderbilt University, Nashville, USA
3 shared publications - Nilam J. Soni
Division of Hospital Medicine, Joe R. Theresa Lozano Long School of Medicine University of Texas Health San Antonio San Antonio Texas USA
3 shared publications - Charles M. LoPresti
Hospital Medicine Service University Hospitals Cleveland Ohio USA
2 shared publications Clay Block
Medicine Services, White River Junction VA Medical Center, White River Junction, Vermont, UNITED STATES
2 shared publicationsElizabeth K. Haro
2 shared publications
Latest Publications
- Open Access
- 12 December 2025
- Published by Springer Nature in BMC Health Services Research
- Vol. 25 (1) , 1595
Do discharge delays explain longer stays at veterans health administration hospitals?
Background: Discharge delays are difficult to quantify without standardized indicators for when patients are medically ready for discharge. We aimed to estimate the proportion of increased hospital length of stay attributable to discharge delays, as proxied by increases in ‘avoidable’ days. Methods: We conducted a retrospective cohort study of Veterans Health Administration hospitals in the continental United States with emergency departments between 1 March 2019 and 28 February 2023. We included Veterans who were discharged from an acute medicine service without a COVID-19 diagnosis. We used standardized utilization management criteria to count ‘avoidable’ days, defined as hospital days when acute care was no longer required. Our primary outcome was geometric mean length of the discharging stay (the final acute medicine segment prior to discharge), which reflects the time most susceptible to discharge delays. Results: During the study period there were 868,031 eligible hospitalizations. Adjusted geometric mean length of discharging stay increased 9.3% (95% CI, 8.7% to 9.9%) from the pre-pandemic year to the third pandemic year, with the largest increase among discharges to facility-based post-acute care (23.3% [95% CI, 21.6 to 24.9%]). However, among all hospitalizations only 16% (95% CI, 15 to 17%) of the increase in discharging stay was attributable to an increase in avoidable days. Conclusions: Most of the increase in length of hospital discharging stay was not explained by discharge delays and may instead reflect longer periods of acute care delivery. Improving acute care processes may more effectively reduce hospital capacity strain than bolstering post-acute care availability.
- 12 December 2025
- Published by Springer Nature in BMC Health Services Research
- Vol. 25 (1) , 1595
Open AccessDo discharge delays explain longer stays at veterans health administration hospitals?
Background: Discharge delays are difficult to quantify without standardized indicators for when patients are medically ready for discharge. We aimed to estimate the proportion of increased hospital length of stay attributable to discharge delays, as proxied by increases in ‘avoidable’ days. Methods: We conducted a retrospective cohort study of Veterans Health Administration hospitals in the continental United States with emergency departments between 1 March 2019 and 28 February 2023. We included Veterans who were discharged from an acute medicine service without a COVID-19 diagnosis. We used standardized utilization management criteria to count ‘avoidable’ days, defined as hospital days when acute care was no longer required. Our primary outcome was geometric mean length of the discharging stay (the final acute medicine segment prior to discharge), which reflects the time most susceptible to discharge delays. Results: During the study period there were 868,031 eligible hospitalizations. Adjusted geometric mean length of discharging stay increased 9.3% (95% CI, 8.7% to 9.9%) from the pre-pandemic year to the third pandemic year, with the largest increase among discharges to facility-based post-acute care (23.3% [95% CI, 21.6 to 24.9%]). However, among all hospitalizations only 16% (95% CI, 15 to 17%) of the increase in discharging stay was attributable to an increase in avoidable days. Conclusions: Most of the increase in length of hospital discharging stay was not explained by discharge delays and may instead reflect longer periods of acute care delivery. Improving acute care processes may more effectively reduce hospital capacity strain than bolstering post-acute care availability.
- 19 December 2023
- Published by Wiley in Journal of Hospital Medicine
- Vol. 19 (2) , 112-115
How much magnesium sulfate is needed to “keep total serum magnesium above 2.0 mg/dL”?
For patients at increased risk of life-threating ventricular arrythmias, hospitalists often administer intravenous magnesium sulfate to maintain total serum magnesium concentration (TsMg) above 2 mg/dL. How long each dose keeps TsMg above this threshold is not well known, however. We collected TsMg values from 12,618 veterans who were given 24,363 doses of intravenous magnesium sulfate during 14,901 hospitalizations for acute heart failure. Across dose amounts, the average TsMg dropped below 2.0 mg/dL within 24 h of administration. When we limited our analysis to 2 g doses (the most common dose) and adjusted for baseline TsMg, estimated glomerular filtration rate, oral magnesium supplementation, and loop diuretic dosing, we found that less than half of the adjusted TsMg values remained above 2.0 mg/dL just 12 h after dose administration. Hospitalists should expect, on average, to administer 2 g intravenous magnesium sulfate at least twice daily to maintain total serum magnesium above 2 mg/dL.
- 19 December 2023
- Published by Wiley in Journal of Hospital Medicine
- Vol. 19 (2) , 112-115
How much magnesium sulfate is needed to “keep total serum magnesium above 2.0 mg/dL”?
For patients at increased risk of life-threating ventricular arrythmias, hospitalists often administer intravenous magnesium sulfate to maintain total serum magnesium concentration (TsMg) above 2 mg/dL. How long each dose keeps TsMg above this threshold is not well known, however. We collected TsMg values from 12,618 veterans who were given 24,363 doses of intravenous magnesium sulfate during 14,901 hospitalizations for acute heart failure. Across dose amounts, the average TsMg dropped below 2.0 mg/dL within 24 h of administration. When we limited our analysis to 2 g doses (the most common dose) and adjusted for baseline TsMg, estimated glomerular filtration rate, oral magnesium supplementation, and loop diuretic dosing, we found that less than half of the adjusted TsMg values remained above 2.0 mg/dL just 12 h after dose administration. Hospitalists should expect, on average, to administer 2 g intravenous magnesium sulfate at least twice daily to maintain total serum magnesium above 2 mg/dL.
- Open Access
- 7 August 2023
- Published by Elsevier in CHEST Critical Care
- Vol. 1 (2)
Current Use, Training, and Barriers to Point-of-Care Ultrasound Use in ICUs in the Department of Veterans Affairs
- 7 August 2023
- Published by Elsevier in CHEST Critical Care
- Vol. 1 (2)
Open AccessCurrent Use, Training, and Barriers to Point-of-Care Ultrasound Use in ICUs in the Department of Veterans Affairs
- 1 March 2021
- Published by Elsevier in The American Journal of Medicine
- Vol. 134 (3) , 391-399.e8
Retention of Point-of-Care Ultrasound Skills Among Practicing Physicians: Findings of the VA National POCUS Training Program
- 1 March 2021
- Published by Elsevier in The American Journal of Medicine
- Vol. 134 (3) , 391-399.e8
Retention of Point-of-Care Ultrasound Skills Among Practicing Physicians: Findings of the VA National POCUS Training Program
- Open Access
- 3 May 2020
- Published by Greater Baltimore Medical Center in Journal of Community Hospital Internal Medicine Perspectives
- Vol. 10 (3) , 199-203
Discharge-ready volume status in acute decompensated heart failure: a survey of hospitalists
Acute decompensated heart failure is the leading cause of hospitalization in older adults. Clinical practice guidelines recommend patients should be euvolemic at hospital discharge – yet accurate assessment of volume status is recognized to be exceptionally challenging. This conundrum led us to investigate how hospitalists are assessing volume status and discharge- readiness of patients hospitalized with heart failure. We collected audience response data during a didactic heart failure presentation at the 2019 Society of Hospital Medicine annual meeting. Respondents (n = 216), 76% of whom were practicing physician hospitalists caring for more than 20 acute heart failure patients per year, were presented six questions. Eighteen percent of respondents reported not being able to determine the completeness of decongestion on discharge and 32% reported that complete decongestion was not a treatment target. These findings suggest important differences between guideline recommendations and how hospitalists treat heart failure in current clinical practice.
- 3 May 2020
- Published by Greater Baltimore Medical Center in Journal of Community Hospital Internal Medicine Perspectives
- Vol. 10 (3) , 199-203
Open AccessDischarge-ready volume status in acute decompensated heart failure: a survey of hospitalists
Acute decompensated heart failure is the leading cause of hospitalization in older adults. Clinical practice guidelines recommend patients should be euvolemic at hospital discharge – yet accurate assessment of volume status is recognized to be exceptionally challenging. This conundrum led us to investigate how hospitalists are assessing volume status and discharge- readiness of patients hospitalized with heart failure. We collected audience response data during a didactic heart failure presentation at the 2019 Society of Hospital Medicine annual meeting. Respondents (n = 216), 76% of whom were practicing physician hospitalists caring for more than 20 acute heart failure patients per year, were presented six questions. Eighteen percent of respondents reported not being able to determine the completeness of decongestion on discharge and 32% reported that complete decongestion was not a treatment target. These findings suggest important differences between guideline recommendations and how hospitalists treat heart failure in current clinical practice.
- 1 September 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (9) , 1794-1797
Current use and training needs of point-of-care ultrasound in emergency departments: A national survey of VA hospitals
- 1 September 2019
- Published by Elsevier in The American Journal of Emergency Medicine
- Vol. 37 (9) , 1794-1797
Current use and training needs of point-of-care ultrasound in emergency departments: A national survey of VA hospitals
- 1 June 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (6) , 065003
Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration
Objective : Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during diuretic-induced fluid removal. Approach : During hemodialysis we compared change in maximum diameter of the inferior vena cava by ultrasound ( ) to change in relative blood volume derived from capillary hemoglobin concentration from finger-clip spectrophotometry (RBV SpHb ). We grouped profiles of these measurements into three distinct shapes using an unbiased, data-driven modeling technique. Methods : Fifty patients who were not in acute heart failure underwent a mean of five paired measurements while an average of 1.3 liters of fluid was removed over 2 h during single hemodialysis sessions. changed −1.0 mm (95% CI −1.9 to −0.2 mm) and the RBV SpHb changed −1.1% (95% CI −2.7 to +0.5%), but these changes were not correlated ( r −0.04, 95% CI −0.32 to +0.24). Nor was there agreement between categorization of profiles of change in the two measurements (kappa −0.1, 95% CI −0.3 to +0.1). Significance : and RBV SpHb estimates of blood volume do not agree during mechanical fluid removal, likely because regional changes in blood flow and pressure modify IVC dimensions as well as changes total blood volume.
- 1 June 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (6) , 065003
Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration
Objective : Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during diuretic-induced fluid removal. Approach : During hemodialysis we compared change in maximum diameter of the inferior vena cava by ultrasound ( ) to change in relative blood volume derived from capillary hemoglobin concentration from finger-clip spectrophotometry (RBV SpHb ). We grouped profiles of these measurements into three distinct shapes using an unbiased, data-driven modeling technique. Methods : Fifty patients who were not in acute heart failure underwent a mean of five paired measurements while an average of 1.3 liters of fluid was removed over 2 h during single hemodialysis sessions. changed −1.0 mm (95% CI −1.9 to −0.2 mm) and the RBV SpHb changed −1.1% (95% CI −2.7 to +0.5%), but these changes were not correlated ( r −0.04, 95% CI −0.32 to +0.24). Nor was there agreement between categorization of profiles of change in the two measurements (kappa −0.1, 95% CI −0.3 to +0.1). Significance : and RBV SpHb estimates of blood volume do not agree during mechanical fluid removal, likely because regional changes in blood flow and pressure modify IVC dimensions as well as changes total blood volume.
- Open Access
- 22 February 2019
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 11 (1) , 4
Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
Current methods of assessing competence in acquiring point-of-care ultrasound images are inadequate. They rely upon cumbersome rating systems that do not depend on the actual outcome measured and lack evidence of validity. We describe a new method that uses a rigorous statistical model to assess performance of individual trainees based on the actual task, image acquisition. Measurements obtained from the images acquired (the actual desired outcome) are themselves used to validate effective training and competence acquiring ultrasound images. We enrolled a convenience sample of 21 spontaneously breathing adults from a general medicine ward. In random order, two trainees (A and B) and an instructor contemporaneously acquired point-of-care ultrasound images of the inferior vena cava and the right internal jugular vein from the same patients. Blinded diameter measurements from each ultrasound were analyzed quantitatively using a multilevel model. Consistent mean differences between each trainee’s and the instructor’s images were ascribed to systematic acquisition errors, indicative of poor measurement technique and a need for further training. Wider variances were attributed to sporadic errors, indicative of inconsistent application of measurement technique across patients. In addition, the instructor recorded qualitative observations of each trainee’s performance during image acquisition. For all four diameters, the means and variances of measurements from trainee A’s images differed significantly from the instructor’s, whereas those from trainee B’s images were comparable. Techniques directly observed by the instructor supported these model-derived findings. For example, mean anteroposterior diameters of the internal jugular vein obtained from trainee A’s images were 3.8 mm (90% CI 2.3–5.4) smaller than from the instructor’s; this model-derived finding matched the instructor’s observation that trainee A compressed the vein during acquisition. Instructor summative assessments agreed with model-derived findings, providing internal validation of the descriptive and quantitative assessments of competence acquiring ultrasound images. Clinical measurements obtained from point-of-care ultrasound images acquired contemporaneously by trainees and an instructor can be used to quantitatively assess the image acquisition competence of specific trainees. This method may obviate resource-intensive qualitative rating systems that are based on ultrasound image quality and direct observation, while also helping instructors guide remediation.
- 22 February 2019
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 11 (1) , 4
Open AccessClinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
Current methods of assessing competence in acquiring point-of-care ultrasound images are inadequate. They rely upon cumbersome rating systems that do not depend on the actual outcome measured and lack evidence of validity. We describe a new method that uses a rigorous statistical model to assess performance of individual trainees based on the actual task, image acquisition. Measurements obtained from the images acquired (the actual desired outcome) are themselves used to validate effective training and competence acquiring ultrasound images. We enrolled a convenience sample of 21 spontaneously breathing adults from a general medicine ward. In random order, two trainees (A and B) and an instructor contemporaneously acquired point-of-care ultrasound images of the inferior vena cava and the right internal jugular vein from the same patients. Blinded diameter measurements from each ultrasound were analyzed quantitatively using a multilevel model. Consistent mean differences between each trainee’s and the instructor’s images were ascribed to systematic acquisition errors, indicative of poor measurement technique and a need for further training. Wider variances were attributed to sporadic errors, indicative of inconsistent application of measurement technique across patients. In addition, the instructor recorded qualitative observations of each trainee’s performance during image acquisition. For all four diameters, the means and variances of measurements from trainee A’s images differed significantly from the instructor’s, whereas those from trainee B’s images were comparable. Techniques directly observed by the instructor supported these model-derived findings. For example, mean anteroposterior diameters of the internal jugular vein obtained from trainee A’s images were 3.8 mm (90% CI 2.3–5.4) smaller than from the instructor’s; this model-derived finding matched the instructor’s observation that trainee A compressed the vein during acquisition. Instructor summative assessments agreed with model-derived findings, providing internal validation of the descriptive and quantitative assessments of competence acquiring ultrasound images. Clinical measurements obtained from point-of-care ultrasound images acquired contemporaneously by trainees and an instructor can be used to quantitatively assess the image acquisition competence of specific trainees. This method may obviate resource-intensive qualitative rating systems that are based on ultrasound image quality and direct observation, while also helping instructors guide remediation.
- 8 May 2017
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (8) , 488-496
Reproducibility of point‐of‐care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation
Purpose: Central vein point‐of‐care ultrasonography must be reproducible to detect intravascular volume changes. We sought to determine which measurement step, image acquisition or interpretation, could be more compromising for reproducibility.Methods: Three investigators each acquired inferior vena cava (IVC) and internal jugular (IJV) vein ultrasonographic sequences (US) from a convenience sample of 21 hospitalized general medicine participants and then interpreted each US three separate times. We partitioned the random errors of acquisition and interpretation, attributing wider dispersions of each to larger reductions in reproducibility.Results: We analyzed 351 interpretations of 39 IVC and 432 interpretations of 48 IJV US. Reproducibility of the maximum (standard error of measurement 3.3 mm [95% confidence interval, CI 2.7–4.2 mm]) and minimum (4.8 mm [3.9–6.3 mm]) IVC diameter measurements were worse than that of the mediolateral (2.5 mm [2.0–3.2 mm]) and anteroposterior (2.5 mm [2.0–3.1 mm]) IJV diameters. The dispersions of random measurement errors were wider among acquisitions than interpretations.Conclusions: Among our investigators, central vein diameter measurements obtained by point‐of‐care ultrasonography are not sufficiently reproducible to distinguish clinically meaningful intravascular volume changes from measurement errors. Reproducibility could be most effectively improved by reducing the random measurement errors of acquisition. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:488–496, 2017
- 8 May 2017
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 45 (8) , 488-496
Reproducibility of point‐of‐care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation
Purpose: Central vein point‐of‐care ultrasonography must be reproducible to detect intravascular volume changes. We sought to determine which measurement step, image acquisition or interpretation, could be more compromising for reproducibility.Methods: Three investigators each acquired inferior vena cava (IVC) and internal jugular (IJV) vein ultrasonographic sequences (US) from a convenience sample of 21 hospitalized general medicine participants and then interpreted each US three separate times. We partitioned the random errors of acquisition and interpretation, attributing wider dispersions of each to larger reductions in reproducibility.Results: We analyzed 351 interpretations of 39 IVC and 432 interpretations of 48 IJV US. Reproducibility of the maximum (standard error of measurement 3.3 mm [95% confidence interval, CI 2.7–4.2 mm]) and minimum (4.8 mm [3.9–6.3 mm]) IVC diameter measurements were worse than that of the mediolateral (2.5 mm [2.0–3.2 mm]) and anteroposterior (2.5 mm [2.0–3.1 mm]) IJV diameters. The dispersions of random measurement errors were wider among acquisitions than interpretations.Conclusions: Among our investigators, central vein diameter measurements obtained by point‐of‐care ultrasonography are not sufficiently reproducible to distinguish clinically meaningful intravascular volume changes from measurement errors. Reproducibility could be most effectively improved by reducing the random measurement errors of acquisition. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:488–496, 2017