Somboon Rassame
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Somboon Rassame has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Hibiki
JC STEM Lab of Innovative Thermo-Fluid Science, Department of Mechanical Engineering, City University of Hong Kong 2 , 83 Tat Chee Avenue, Kowloon Tong
13 shared publications Mamoru Ishii
8 shared publications- Jun Yang
School of Energy and Power Engineering, Huazhong University of Science and Technology (HUST), Wuhan 430074, China
6 shared publications Jaehyok Lim
3 shared publicationsTakashi Hibiki
Department of Mechanical Engineering, City University of Hong Kong, Hong Kong,Kowloon Tong, China
3 shared publicationsD.Y. Lee
School of Nuclear Engineering, Purdue University, 400 Central Drive, West Lafayette, IN 47907-2017, USA
2 shared publications
Latest Publications
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Impact of non-uniform inlet gas flow distribution on two-phase flow characteristics in a rectangular channel
Two-phase flow in rectangular channels is prevalent in numerous industrial applications, requiring precise predictive models to guarantee operational safety and efficiency. To achieve a more detailed analysis of two-phase flow in rectangular channels, the two-group (2G) approach has been adopted, categorizing bubbles into two distinct groups. In this approach, group one (G1) bubbles correspond to distorted spherical bubbles, while group two (G2) bubbles comprise churn-turbulent, slug, and cap bubbles. The 2G two-fluid model, combined with the interfacial area transport equation, has been proposed to enable dynamic predictions of void fraction and heat transfer characteristics in two-phase systems. The 2G drift-flux model has also been proposed as a critical closure relation for the one-dimensional 2G two-fluid model. The 2G drift-flux correlation in rectangular channels, which closes the 2G drift-flux model, has been developed based on experimental data obtained in a rectangular channel under uniform inlet boundary conditions characterized by uniform distributions of gas flow rate. The present study investigated the impact of non-uniform inlet boundary conditions, characterized by non-uniform distributions of gas flow rate, on void fraction and the 2G drift-flux correlation in a rectangular channel. Significant deviations exceeding 30% were observed in predictions of G1 and G2 void fractions under the channel center peak gas flow (CPG) and single sidewall peak gas flow (SPG) conditions. Therefore, G1 and G2 distribution parameters in the 2G drift-flux correlation were modified. The modified 2G drift-flux correlations accurately predicted the G1 and G2 void fractions under CPG and SPG conditions.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Impact of non-uniform inlet gas flow distribution on two-phase flow characteristics in a rectangular channel
Two-phase flow in rectangular channels is prevalent in numerous industrial applications, requiring precise predictive models to guarantee operational safety and efficiency. To achieve a more detailed analysis of two-phase flow in rectangular channels, the two-group (2G) approach has been adopted, categorizing bubbles into two distinct groups. In this approach, group one (G1) bubbles correspond to distorted spherical bubbles, while group two (G2) bubbles comprise churn-turbulent, slug, and cap bubbles. The 2G two-fluid model, combined with the interfacial area transport equation, has been proposed to enable dynamic predictions of void fraction and heat transfer characteristics in two-phase systems. The 2G drift-flux model has also been proposed as a critical closure relation for the one-dimensional 2G two-fluid model. The 2G drift-flux correlation in rectangular channels, which closes the 2G drift-flux model, has been developed based on experimental data obtained in a rectangular channel under uniform inlet boundary conditions characterized by uniform distributions of gas flow rate. The present study investigated the impact of non-uniform inlet boundary conditions, characterized by non-uniform distributions of gas flow rate, on void fraction and the 2G drift-flux correlation in a rectangular channel. Significant deviations exceeding 30% were observed in predictions of G1 and G2 void fractions under the channel center peak gas flow (CPG) and single sidewall peak gas flow (SPG) conditions. Therefore, G1 and G2 distribution parameters in the 2G drift-flux correlation were modified. The modified 2G drift-flux correlations accurately predicted the G1 and G2 void fractions under CPG and SPG conditions.
- 1 November 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (11)
Full-range drift-flux model for upward two-phase flows in vertical rectangular channels
Two-phase flow in rectangular channels is critical in thermal-fluid systems, necessitating accurate two-phase flow analysis for performance optimization. The drift-flux correlation, a key element in two-phase flow analysis, is often limited to specific flow regimes or channel geometries. This study developed a full-range drift-flux correlation for rectangular channels, covering the entire void fraction range from zero to unity. The critical area-averaged void fraction distinguishing between pure-dispersed and beyond-dispersed flows was analytically modeled by the assumed void fraction distributions. In the pure-dispersed flow, the experimentally determined distribution parameter correlation has been well accepted. This study developed a distribution parameter model from the pure-dispersed two-phase flow to the gas single-phase flow based on the approximated void fraction and mixture volumetric flux. In the pure-dispersed flow, the reliable drift velocity correlation was available. This study developed a model of the drift velocity from the pure-dispersed two-phase flow to the gas single-phase flow based on the momentum balance between the gas core and the liquid film. The model validation was conducted using 225 adiabatic and 332 boiling two-phase flow data sourced from 22 experimental studies. The developed full-range drift-flux correlation achieved a mean relative error of −2.18% and a mean absolute relative error of 11.9%, demonstrating robust predictive capability across all flow regimes, under a void fraction of 0.007 70–0.897, a superficial liquid velocity of 0–10.5 m/s, and a superficial gas velocity of 0.006 89–23.9 m/s. The correlation was applicable to rectangular channels with an aspect ratio (= channel gap divided by channel width) of 0.05–1.00.
- 1 November 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (11)
Full-range drift-flux model for upward two-phase flows in vertical rectangular channels
Two-phase flow in rectangular channels is critical in thermal-fluid systems, necessitating accurate two-phase flow analysis for performance optimization. The drift-flux correlation, a key element in two-phase flow analysis, is often limited to specific flow regimes or channel geometries. This study developed a full-range drift-flux correlation for rectangular channels, covering the entire void fraction range from zero to unity. The critical area-averaged void fraction distinguishing between pure-dispersed and beyond-dispersed flows was analytically modeled by the assumed void fraction distributions. In the pure-dispersed flow, the experimentally determined distribution parameter correlation has been well accepted. This study developed a distribution parameter model from the pure-dispersed two-phase flow to the gas single-phase flow based on the approximated void fraction and mixture volumetric flux. In the pure-dispersed flow, the reliable drift velocity correlation was available. This study developed a model of the drift velocity from the pure-dispersed two-phase flow to the gas single-phase flow based on the momentum balance between the gas core and the liquid film. The model validation was conducted using 225 adiabatic and 332 boiling two-phase flow data sourced from 22 experimental studies. The developed full-range drift-flux correlation achieved a mean relative error of −2.18% and a mean absolute relative error of 11.9%, demonstrating robust predictive capability across all flow regimes, under a void fraction of 0.007 70–0.897, a superficial liquid velocity of 0–10.5 m/s, and a superficial gas velocity of 0.006 89–23.9 m/s. The correlation was applicable to rectangular channels with an aspect ratio (= channel gap divided by channel width) of 0.05–1.00.
- 13 July 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (3) , 327-342
Simulation using representative data selection for transboundary radiation effect evaluation by Nuclear Accident Consequence Analysis Code (NACAC)
- 13 July 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (3) , 327-342
Simulation using representative data selection for transboundary radiation effect evaluation by Nuclear Accident Consequence Analysis Code (NACAC)
- 29 March 2019
- Published by Springer Nature in Experimental and Computational Multiphase Flow
- Vol. 1 (1) , 73-84
Analytical model for predicting oil fraction in horizontal oil–water two-phase flow
- 29 March 2019
- Published by Springer Nature in Experimental and Computational Multiphase Flow
- Vol. 1 (1) , 73-84
Analytical model for predicting oil fraction in horizontal oil–water two-phase flow
- Open Access
- 3 February 2019
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2019, 1-16
Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition models of ART Mod 2, namely, gravitational settling model, Brownian diffusion model, diffusiophoresis model, and thermophoresis model in order to increase potential of capturing the deposition phenomena. This study aims to compare the simulated results of modified ART Mod 2 with aerosol deposition of cesium compounds in the containment vessel of Phébus FPT3 experiment, in order to validate modified ART Mod 2 code. It is found that aerosol deposition using modified ART Mod 2 agrees with Phébus FPT3. Prediction of Brownian diffusion is significantly improved due to the consideration of turbulent damping process. Cesium mass flow rate and aerosol size are factors that can significantly influence the uncertainty of the results. When conditions of single volumes are carefully selected to match those of the Phébus FPT3 experiment, modified ART Mod 2 can predict aerosol deposition in Phébus FPT3 with relative accuracy.
- 3 February 2019
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2019, 1-16
Open AccessValidation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel
Evaluation of aerosol deposition in the containment vessel is an important step for the assessment of radioactive material release to the environment. ART Mod 2 is a calculation code that is used for evaluation of aerosol deposition in the containment vessel. The authors modified aerosol deposition models of ART Mod 2, namely, gravitational settling model, Brownian diffusion model, diffusiophoresis model, and thermophoresis model in order to increase potential of capturing the deposition phenomena. This study aims to compare the simulated results of modified ART Mod 2 with aerosol deposition of cesium compounds in the containment vessel of Phébus FPT3 experiment, in order to validate modified ART Mod 2 code. It is found that aerosol deposition using modified ART Mod 2 agrees with Phébus FPT3. Prediction of Brownian diffusion is significantly improved due to the consideration of turbulent damping process. Cesium mass flow rate and aerosol size are factors that can significantly influence the uncertainty of the results. When conditions of single volumes are carefully selected to match those of the Phébus FPT3 experiment, modified ART Mod 2 can predict aerosol deposition in Phébus FPT3 with relative accuracy.
- 10 September 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (3)
Drift-Flux Correlation of Oil–Water Flow in Horizontal Channels
An accurate and practical approach is necessary for predicting oil fraction in horizontal oil–water flows. In this study, a concept of a drift-flux model is adopted to develop a predictive method for the oil fraction in the horizontal oil–water flows due to its simplicity and practicality. A new drift-flux correlation for the horizontal oil–water flows is developed based on the least square method using collected experimental data. The distribution parameter is determined to be 1.05 for the data with the ratio of oil density to water density ranging from 0.787 to 1.00, whereas the oil fraction weighted mean drift velocity is set at 0 m/s due to the flow direction perpendicular to the gravity direction. The physical meaning for the order of unity of the distribution parameter is explained by introducing a simple model. The predictive capability of the new drift-flux correlation is examined using the collected database of oil–water flows in horizontal pipes under a variety of test conditions. It is demonstrated that the new drift-flux correlation can predict the existing oil fractions in the horizontal pipe channels with the mean absolute error, standard deviation, mean relative deviation, and mean absolute relative deviation being −0.0124, 0.0338, −3.25%, and 9.57%, respectively.
- 10 September 2018
- Published by ASME International in Journal of Fluids Engineering
- Vol. 141 (3)
Drift-Flux Correlation of Oil–Water Flow in Horizontal Channels
An accurate and practical approach is necessary for predicting oil fraction in horizontal oil–water flows. In this study, a concept of a drift-flux model is adopted to develop a predictive method for the oil fraction in the horizontal oil–water flows due to its simplicity and practicality. A new drift-flux correlation for the horizontal oil–water flows is developed based on the least square method using collected experimental data. The distribution parameter is determined to be 1.05 for the data with the ratio of oil density to water density ranging from 0.787 to 1.00, whereas the oil fraction weighted mean drift velocity is set at 0 m/s due to the flow direction perpendicular to the gravity direction. The physical meaning for the order of unity of the distribution parameter is explained by introducing a simple model. The predictive capability of the new drift-flux correlation is examined using the collected database of oil–water flows in horizontal pipes under a variety of test conditions. It is demonstrated that the new drift-flux correlation can predict the existing oil fractions in the horizontal pipe channels with the mean absolute error, standard deviation, mean relative deviation, and mean absolute relative deviation being −0.0124, 0.0338, −3.25%, and 9.57%, respectively.
- Open Access
- 25 October 2017
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2017, 1-12
Assessment of RELAP/SCDAPSIM/MOD3.4 Prediction Capability with Severe Fuel Damage Scoping Test
The Power Burst Facility (PBF) was designed to provide experimental data to determine the thresholds for failure during accident conditions. Thus, the PBF benchmark using severe accidental analysis codes is essential to designing reactor for current directions. This assessment verified and validated that the RELAP/SCDAPSIM/MOD3.4 code can be used to assess the Severe Fuel Damage Scoping Test (SFD-ST) performed in the PBF facility. This study compares the cladding temperatures and hydrogen production results calculated by the RELAP/SCDAPSIM/MOD3.4 code with experimental data and calculated results from the SCDAP/RELAP5/MOD3.2 and SCDAP/RELAP5/MOD3.3 codes. The interested parameters are cladding temperature and hydrogen production since the cladding temperature affects hydrogen production and consequently influences the accident scenario. The calculated cladding temperatures and hydrogen production results from the RELAP/SCDAPSIM/MOD3.4 code are in a good agreement with the experimental data and are generally more reasonable than the calculated results from the SCDAP/RELAP5/MOD3.2 and SCDAP/RELAP5/MOD3.3 codes. There are some discrepancies in the cladding temperature and hydrogen production results but they are expected.
- 25 October 2017
- Published by Wiley in Science and Technology of Nuclear Installations
- Vol. 2017, 1-12
Open AccessAssessment of RELAP/SCDAPSIM/MOD3.4 Prediction Capability with Severe Fuel Damage Scoping Test
The Power Burst Facility (PBF) was designed to provide experimental data to determine the thresholds for failure during accident conditions. Thus, the PBF benchmark using severe accidental analysis codes is essential to designing reactor for current directions. This assessment verified and validated that the RELAP/SCDAPSIM/MOD3.4 code can be used to assess the Severe Fuel Damage Scoping Test (SFD-ST) performed in the PBF facility. This study compares the cladding temperatures and hydrogen production results calculated by the RELAP/SCDAPSIM/MOD3.4 code with experimental data and calculated results from the SCDAP/RELAP5/MOD3.2 and SCDAP/RELAP5/MOD3.3 codes. The interested parameters are cladding temperature and hydrogen production since the cladding temperature affects hydrogen production and consequently influences the accident scenario. The calculated cladding temperatures and hydrogen production results from the RELAP/SCDAPSIM/MOD3.4 code are in a good agreement with the experimental data and are generally more reasonable than the calculated results from the SCDAP/RELAP5/MOD3.2 and SCDAP/RELAP5/MOD3.3 codes. There are some discrepancies in the cladding temperature and hydrogen production results but they are expected.
- Open Access
- 8 June 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 860 (1) , 012040
Development of remaining wall thickness measurement system for boiler wall tube using gamma scattering technique
In this study, the General Monte Carlo N-Particle version 5 (MCNP5) simulation of the measuring system for the remaining thickness of the wall tube using gamma scattering technique is performed to investigate the applicability of this technique and to find the optimum geometrical setup for the experimental setup. The numerical results show that the optimal geometry condition to provide the highest ratio between the gamma flux changes per thickness variation, namely, the measurement sensitivity, is the alignment of the source incidence angle of 30 degree and detector scattering angle of 30 degrees. Sequentially, the preliminary experiment of thickness measurement system for the tube using the gamma scattering technique is conducted based on the selected geometrical test setup by the simulation. It is found that the experimental results have generally a good agreement with the calculated results. Conclusively, it is suggested that the gamma scattering technique has a potential method to measure the remaining wall thickness in the boiler wall tube.
- 8 June 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 860 (1) , 012040
Open AccessDevelopment of remaining wall thickness measurement system for boiler wall tube using gamma scattering technique
In this study, the General Monte Carlo N-Particle version 5 (MCNP5) simulation of the measuring system for the remaining thickness of the wall tube using gamma scattering technique is performed to investigate the applicability of this technique and to find the optimum geometrical setup for the experimental setup. The numerical results show that the optimal geometry condition to provide the highest ratio between the gamma flux changes per thickness variation, namely, the measurement sensitivity, is the alignment of the source incidence angle of 30 degree and detector scattering angle of 30 degrees. Sequentially, the preliminary experiment of thickness measurement system for the tube using the gamma scattering technique is conducted based on the selected geometrical test setup by the simulation. It is found that the experimental results have generally a good agreement with the calculated results. Conclusively, it is suggested that the gamma scattering technique has a potential method to measure the remaining wall thickness in the boiler wall tube.