Jafariah Jaafar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jafariah Jaafar has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ambavaram Vijaya Bhaskar Reddy
Sri Venkateswara University
7 shared publications Nobuo Tanaka
Department of Biomolecular Engineering , Kyoto Institute of Technology , Matsugasaki, Kyoto, Japan
6 shared publicationsTohru Ikegami
4 shared publicationsZulkifli Yusop
Centre for Environmental Sustainability and Water Security (IPASA), Research Institute for Sustainable Environment, Universiti Teknologi Malaysia, Johor, Malaysia
4 shared publicationsAzmi B. Aris
Centre for Environmental Sustainability and Water Security (IPASA), Research Institute for Sustainable Environment, Universiti Teknologi Malaysia, Johor, Malaysia
3 shared publicationsAzmi Bin Aris
Centre for Environmental Sustainability and Water Security (IPASA), Research Institute for Sustainable Environment, Universiti Teknologi Malaysia, Johor Bahru, Malaysia
3 shared publications
Latest Publications
- 28 June 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (15) , 3086-3093
A simple, selective, and sensitive gas chromatography–mass spectrometry method for the analysis of five process‐related impurities in atenolol bulk drug and capsule formulations
An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process‐related impurities, viz., 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, 4‐hydroxyphenylacetic acid, methyl‐4‐hydroxyphenylacetate, and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX‐5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 μm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, and 4‐hydroxyphenylacetic acid at 0.3 ppm, and methyl‐4‐hydroxyphenylacetate and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3–10 ppm for 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, and 4‐hydroxyphenylacetic acid, and 0.35–10 ppm for methyl‐4‐hydroxyphenylacetate and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.
- 28 June 2017
- Published by Wiley in Journal of Separation Science
- Vol. 40 (15) , 3086-3093
A simple, selective, and sensitive gas chromatography–mass spectrometry method for the analysis of five process‐related impurities in atenolol bulk drug and capsule formulations
An extremely sensitive and simple gas chromatography with mass spectrometry method was developed and completely validated for the analysis of five process‐related impurities, viz., 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, 4‐hydroxyphenylacetic acid, methyl‐4‐hydroxyphenylacetate, and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile, in atenolol. The separation of impurities was accomplished on a BPX‐5 column with dimensions of 50 m × 0.25 mm i.d. and 0.25 μm film thickness. The method validation was performed following International Conference on Harmonisation guidelines in which the method was capable to quantitate 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, and 4‐hydroxyphenylacetic acid at 0.3 ppm, and methyl‐4‐hydroxyphenylacetate and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile at 0.35 ppm with respect to 10 mg/mL of atenolol. The method was linear over the concentration range of 0.3–10 ppm for 4‐hydroxy‐l‐phenylglycine, 4‐hydroxyphenylacetonitrile, and 4‐hydroxyphenylacetic acid, and 0.35–10 ppm for methyl‐4‐hydroxyphenylacetate and 2‐[4‐{(2RS)‐2‐hydroxy‐3‐[(1‐methylethyl)amino]propoxy}phenyl]acetonitrile. The correlation coefficient in each case was found ≥0.998. The repeatability and recovery values were acceptable, and found between 89.38% and 105.60% for all five impurities under optimized operating conditions. The method developed here is simple, selective, and sensitive with apparently better resolution than the reported methods. Hence, the method is a straightforward and good quality control tool for the quantitation of selected impurities at trace concentrations in atenolol.
- Open Access
- 14 February 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (19) , 11550-11560
Simulation of a conventional water treatment plant for the minimization of new emerging pollutants in drinking water sources: process optimization using response surface methodology
This study described the ability of conventional water treatment plants for the removal of NEPs by optimizing the concentrations of pH, PAC, activated carbon and chlorine (Cl2).
- 14 February 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (19) , 11550-11560
Open AccessSimulation of a conventional water treatment plant for the minimization of new emerging pollutants in drinking water sources: process optimization using response surface methodology
This study described the ability of conventional water treatment plants for the removal of NEPs by optimizing the concentrations of pH, PAC, activated carbon and chlorine (Cl2).
- 16 November 2016
- Published by Bentham Science Publishers Ltd. in Current Drug Discovery Technologies
- Vol. 13 (4) , 211-224
Advances in Drug Discovery: Impact of Genomics and Role of Analytical Instrumentation
Drug discovery is a highly complicated, tedious and potentially rewarding approach associated with great risk. Pharmaceutical companies literally spend millions of dollars to produce a single successful drug. The drug discovery process also need strict compliance to the directions on manufacturing and testing of new drug standards before their release into market. All these regulations created the necessity to develop advanced approaches in drug discovery. The contributions of advanced technologies including high resolution analytical instruments, 3-D biological printing, next-generation sequencing and bioinformatics have made positive impact on drug discovery & development. Fortunately, all these advanced technologies are evolving at the right time when new issues are rising in drug development process. In the present review, we have discussed the role of genomics and advanced analytical techniques in drug discovery. Further, we have also discussed the significant advances in drug discovery as case studies.
- 16 November 2016
- Published by Bentham Science Publishers Ltd. in Current Drug Discovery Technologies
- Vol. 13 (4) , 211-224
Advances in Drug Discovery: Impact of Genomics and Role of Analytical Instrumentation
Drug discovery is a highly complicated, tedious and potentially rewarding approach associated with great risk. Pharmaceutical companies literally spend millions of dollars to produce a single successful drug. The drug discovery process also need strict compliance to the directions on manufacturing and testing of new drug standards before their release into market. All these regulations created the necessity to develop advanced approaches in drug discovery. The contributions of advanced technologies including high resolution analytical instruments, 3-D biological printing, next-generation sequencing and bioinformatics have made positive impact on drug discovery & development. Fortunately, all these advanced technologies are evolving at the right time when new issues are rising in drug development process. In the present review, we have discussed the role of genomics and advanced analytical techniques in drug discovery. Further, we have also discussed the significant advances in drug discovery as case studies.
- 1 September 2016
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 128, 141-148
Development and validation of a selective, sensitive and stability indicating UPLC–MS/MS method for rapid, simultaneous determination of six process related impurities in darunavir drug substance
- 1 September 2016
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 128, 141-148
Development and validation of a selective, sensitive and stability indicating UPLC–MS/MS method for rapid, simultaneous determination of six process related impurities in darunavir drug substance
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1756 (1) , 080002
Effect of pH and biological media on polyvinylpyrrolidone-capped silver nanoparticles
Toxicity and mobility of silver nanoparticles (AgNPs) vary in different surrounding environments. Surface coatings or functionalization, temperature, pH, dissolved oxygen concentration, nanoparticle concentration, the presence of organic matter, and ionic strength are factors which dictate the transformation of AgNPs in terms of aggregation and stabilization. Thus, the purpose of this study is to investigate the behavior of polyvinylpyrrolidone (PVP)-capped AgNPs at different pHs (pH 2 to 10) and in different biological media (0.1 M phosphate buffer, nutrient broth, P5 and modified P5 media) analyzed using UV-Vis spectroscopy and zeta potential analyzer. The PVP-capped AgNPs changed its behavior in the presence of varying media, after 24 h incubation with shaking at 200 rpm at 30°C. No aggregation was observed at pH 4 to 10, but distinctive at very low pH of 2. Low pH further destabilized PVP-capped AgNPs after 24 h of incubation. High ionic strength 0.1 M phosphate buffer also resulted in slow aggregation and eventually destabilized the nanoparticles. Biological media (nutrient broth, P5 and modified P5 media) containing organic components caused aggregation of the PVP-capped AgNPs. The increase in glucose and nutrient broth concentrations led to increased aggregation. However, PVP-capped AgNPs stabilized after 24 h incubation in media containing a high concentration of glucose and nutrient broth. The results demonstrate that low pH value, high ionic strength and the content of the biological media can influence the stability of AgNPs. This provides information on the aggregation behavior of PVP-capped AgNPs and can possibly further predict the fate, transport as well as the toxicity of silver nanoparticles after being released into the aquatic environment.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1756 (1) , 080002
Effect of pH and biological media on polyvinylpyrrolidone-capped silver nanoparticles
Toxicity and mobility of silver nanoparticles (AgNPs) vary in different surrounding environments. Surface coatings or functionalization, temperature, pH, dissolved oxygen concentration, nanoparticle concentration, the presence of organic matter, and ionic strength are factors which dictate the transformation of AgNPs in terms of aggregation and stabilization. Thus, the purpose of this study is to investigate the behavior of polyvinylpyrrolidone (PVP)-capped AgNPs at different pHs (pH 2 to 10) and in different biological media (0.1 M phosphate buffer, nutrient broth, P5 and modified P5 media) analyzed using UV-Vis spectroscopy and zeta potential analyzer. The PVP-capped AgNPs changed its behavior in the presence of varying media, after 24 h incubation with shaking at 200 rpm at 30°C. No aggregation was observed at pH 4 to 10, but distinctive at very low pH of 2. Low pH further destabilized PVP-capped AgNPs after 24 h of incubation. High ionic strength 0.1 M phosphate buffer also resulted in slow aggregation and eventually destabilized the nanoparticles. Biological media (nutrient broth, P5 and modified P5 media) containing organic components caused aggregation of the PVP-capped AgNPs. The increase in glucose and nutrient broth concentrations led to increased aggregation. However, PVP-capped AgNPs stabilized after 24 h incubation in media containing a high concentration of glucose and nutrient broth. The results demonstrate that low pH value, high ionic strength and the content of the biological media can influence the stability of AgNPs. This provides information on the aggregation behavior of PVP-capped AgNPs and can possibly further predict the fate, transport as well as the toxicity of silver nanoparticles after being released into the aquatic environment.
- 18 June 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (15) , 2580-2587
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics
A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid–liquid extraction using 200 μL of human plasma extracted with methyl tert‐butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra‐day and inter‐day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters.
- 18 June 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (15) , 2580-2587
Development and validation of a rapid ultra high performance liquid chromatography with tandem mass spectrometry method for the simultaneous determination of darunavir, ritonavir, and tenofovir in human plasma: Application to human pharmacokinetics
A sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of darunavir, ritonavir and tenofovir in human plasma. Sample preparation involved a simple liquid–liquid extraction using 200 μL of human plasma extracted with methyl tert‐butyl ether for three analytes and internal standard. The separation was accomplished on an Acquity UPLC BEH C18 (50 mm x 2.1 mm, 1.7 μm) analytical column using gradient elution of acetonitrile/methanol (80:20, v/v) and 5.0 mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4 mL/min. The linearity of the method ranged between 20.0 and 12 000 ng/mL for darunavir, 2.0 and 2280 ng/mL for ritonavir, and 14.0 and 1600 ng/mL for tenofovir using 200 μL of plasma. The method was completely validated for its selectivity, sensitivity, linearity, precision and accuracy, recovery, matrix effect, stability, and dilution integrity. The extraction recoveries were consistent and ranged between 79.91 and 90.04% for all three analytes and internal standard. The method exhibited good intra‐day and inter‐day precision between 1.78 and 6.27%. Finally the method was successfully applied for human pharmacokinetic study in eight healthy male volunteers after the oral administration of 600 mg darunavir along with 100 mg ritonavir and 100 mg tenofovir as boosters.
- 16 June 2015
- Published by Springer Nature in Clean Technologies and Environmental Policy
- Vol. 17 (8) , 2387-2400
Optimization of basic catalyst with ammoniated polyethylene glycol for the removal of naphthenic acid from petroleum crude oil by Box–Behnken design
- 16 June 2015
- Published by Springer Nature in Clean Technologies and Environmental Policy
- Vol. 17 (8) , 2387-2400
Optimization of basic catalyst with ammoniated polyethylene glycol for the removal of naphthenic acid from petroleum crude oil by Box–Behnken design
- 4 February 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (5) , 764-779
Identification, control strategies, and analytical approaches for the determination of potential genotoxic impurities in pharmaceuticals: A comprehensive review
Potential genotoxic impurities in pharmaceuticals at trace levels are of increasing concern to both pharmaceutical industries and regulatory agencies due to their possibility for human carcinogenesis. Molecular functional groups that render starting materials and synthetic intermediates as reactive building blocks for small molecules may also be responsible for their genotoxicity. Determination of these genotoxic impurities at trace levels requires highly sensitive and selective analytical methodologies, which poses tremendous challenges on analytical communities in pharmaceutical research and development. Experimental guidance for the analytical determination of some important classes of genotoxic impurities is still unavailable in the literature. Therefore, the present review explores the structural alerts of commonly encountered potential genotoxic impurities, draft guidance of various regulatory authorities in order to control the level of impurities in drug substances and to assess their toxicity. This review also describes the analytical considerations for the determination of potential genotoxic impurities at trace levels and finally few case studies are also discussed for the determination of some important classes of potential genotoxic impurities. It is the authors’ intention to provide a complete strategy that helps analytical scientists for the analysis of such potential genotoxic impurities in pharmaceuticals.
- 4 February 2015
- Published by Wiley in Journal of Separation Science
- Vol. 38 (5) , 764-779
Identification, control strategies, and analytical approaches for the determination of potential genotoxic impurities in pharmaceuticals: A comprehensive review
Potential genotoxic impurities in pharmaceuticals at trace levels are of increasing concern to both pharmaceutical industries and regulatory agencies due to their possibility for human carcinogenesis. Molecular functional groups that render starting materials and synthetic intermediates as reactive building blocks for small molecules may also be responsible for their genotoxicity. Determination of these genotoxic impurities at trace levels requires highly sensitive and selective analytical methodologies, which poses tremendous challenges on analytical communities in pharmaceutical research and development. Experimental guidance for the analytical determination of some important classes of genotoxic impurities is still unavailable in the literature. Therefore, the present review explores the structural alerts of commonly encountered potential genotoxic impurities, draft guidance of various regulatory authorities in order to control the level of impurities in drug substances and to assess their toxicity. This review also describes the analytical considerations for the determination of potential genotoxic impurities at trace levels and finally few case studies are also discussed for the determination of some important classes of potential genotoxic impurities. It is the authors’ intention to provide a complete strategy that helps analytical scientists for the analysis of such potential genotoxic impurities in pharmaceuticals.
- 1 July 2014
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 20 (4) , 2086-2094
Catalytic neutralization of acidic crude oil utilizing ammonia in ethylene glycol basic solution
- 1 July 2014
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 20 (4) , 2086-2094
Catalytic neutralization of acidic crude oil utilizing ammonia in ethylene glycol basic solution