Rosa Pàmies-Vilà
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rosa Pàmies-Vilà has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Josep Maria Font Llagunes
Department of Mechanical Engineering and Institute for Research and Innovation in Health, Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Barcelona, Catalunya, Spain
14 shared publications - Albert Fabregat-Sanjuan
Department of Mechanical Engineering, Universitat Rovira i Virgili, Tarragona, Spain
8 shared publications - Lluïsa Jordi Nebot
Universitat Politecnica de Catalunya
8 shared publications - Joan Puig-Ortiz
Departamento de Ingeniería Macánica. Universitat Politècnica de Catalunya
6 shared publications - Urbano Lugrís
Laboratory of Mechanical Engineering, University of La Coruña, 15403 Ferrol, Spain
6 shared publications - Javier Cuadrado
University of La Coruña, Ferrol, Spain
5 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (4) , 725-737
Monitoring arm kinematics of children with neuromuscular disorders in daily living: An exploratory study
- 3 November 2026
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 46 (4) , 725-737
Open AccessMonitoring arm kinematics of children with neuromuscular disorders in daily living: An exploratory study
- Open Access
- 8 October 2026
- Published by Wiley in Brain and Behavior
- Vol. 16 (10) , e71805
Reducing Cranial Morphology Error in F3 Scalp Localization: Comparison of Heuristic and Regression‐Based Methods
Purpose: Accurate localization of the F3 scalp position is essential for targeting the dorsolateral prefrontal cortex in repetitive transcranial magnetic stimulation (rTMS), particularly when neuronavigation is unavailable. However, simplified scalp‐based heuristic methods may lead to clinically relevant targeting errors due to substantial interindividual variability in cranial morphology. In this context, this study evaluates the geometric accuracy of commonly used and newly proposed scalp‐based approaches for localizing the F3 position within the International 10–20 system. Specifically, it examines the impact of cranial morphological variability on localization error and assesses whether individualized regression‐based methods can improve targeting accuracy compared to traditional heuristic techniques. Method: The intrinsic geometric accuracy of five F3 localization methods was systematically compared: BeamF3, Adjusted BeamF3, the Scalp Geometry‐based Parameter (SGP) method, NeurallyF3, and a newly developed approach EPlacementF3. A total of 250 anatomically realistic and morphologically diverse 3D head models (125 female, 125 male), generated using the HumanShape platform, were analyzed. Localization error was quantified as the Euclidean distance between each estimated F3 position and the reference coordinate defined by the International 10–20 system. Findings: BeamF3 and Adjusted BeamF3 showed the highest localization errors (mean >5.5 mm and >8 mm, respectively), while the SGP method improved accuracy (≈2.4 mm). In contrast, NeurallyF3 and EPlacementF3 achieved submillimetric errors across sexes. EPlacementF3 demonstrated the best overall performance, with the lowest mean error (∼0.2 mm) and consistent results in the independent validation dataset. These findings highlight the strong influence of cranial morphology on heuristic methods and the superior robustness of individualized regression‐based approaches. Conclusion: Commonly used heuristic methods do not reliably recover the true F3 position across heterogeneous cranial morphologies. In contrast, individualized regression‐based approaches substantially reduce morphology‐related error, supporting more accurate and scalable MRI‐free targeting for rTMS and other non‐invasive brain stimulation applications.
- 8 October 2026
- Published by Wiley in Brain and Behavior
- Vol. 16 (10) , e71805
Open AccessReducing Cranial Morphology Error in F3 Scalp Localization: Comparison of Heuristic and Regression‐Based Methods
Purpose: Accurate localization of the F3 scalp position is essential for targeting the dorsolateral prefrontal cortex in repetitive transcranial magnetic stimulation (rTMS), particularly when neuronavigation is unavailable. However, simplified scalp‐based heuristic methods may lead to clinically relevant targeting errors due to substantial interindividual variability in cranial morphology. In this context, this study evaluates the geometric accuracy of commonly used and newly proposed scalp‐based approaches for localizing the F3 position within the International 10–20 system. Specifically, it examines the impact of cranial morphological variability on localization error and assesses whether individualized regression‐based methods can improve targeting accuracy compared to traditional heuristic techniques. Method: The intrinsic geometric accuracy of five F3 localization methods was systematically compared: BeamF3, Adjusted BeamF3, the Scalp Geometry‐based Parameter (SGP) method, NeurallyF3, and a newly developed approach EPlacementF3. A total of 250 anatomically realistic and morphologically diverse 3D head models (125 female, 125 male), generated using the HumanShape platform, were analyzed. Localization error was quantified as the Euclidean distance between each estimated F3 position and the reference coordinate defined by the International 10–20 system. Findings: BeamF3 and Adjusted BeamF3 showed the highest localization errors (mean >5.5 mm and >8 mm, respectively), while the SGP method improved accuracy (≈2.4 mm). In contrast, NeurallyF3 and EPlacementF3 achieved submillimetric errors across sexes. EPlacementF3 demonstrated the best overall performance, with the lowest mean error (∼0.2 mm) and consistent results in the independent validation dataset. These findings highlight the strong influence of cranial morphology on heuristic methods and the superior robustness of individualized regression‐based approaches. Conclusion: Commonly used heuristic methods do not reliably recover the true F3 position across heterogeneous cranial morphologies. In contrast, individualized regression‐based approaches substantially reduce morphology‐related error, supporting more accurate and scalable MRI‐free targeting for rTMS and other non‐invasive brain stimulation applications.
- Open Access
- 2 July 2026
- Published by Springer Nature
- p. 416-428
Redefining Foot Point Trajectories in Theo Jansen and Klann Mechanisms Using Combined Cam-Linkage Mechanisms
- 2 July 2026
- Published by Springer Nature
- p. 416-428
Open AccessRedefining Foot Point Trajectories in Theo Jansen and Klann Mechanisms Using Combined Cam-Linkage Mechanisms
- Open Access
- 2 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Beam-F3 error analysis and validation of Neurally-F3 equations using realistic head models
Accurate localization of the F3 point is critical for non-invasive brain stimulation, particularly in repetitive transcranial magnetic stimulation (rTMS) targeting the dorsolateral prefrontal cortex. The Beam-F3 heuristic is widely adopted due to its simplicity, yet its accuracy across realistic cranial variations has not been systematically assessed. Here, we evaluated Beam-F3 against the standard F3 location defined by the 10-20 International System using 250 realistic head models representing diverse anatomies. Beam-F3 produced significant errors, with mean deviations of 5.59 ± 1.23 mm in female models and 6.09 ± 1.52 mm in male models. The Adjusted Beam-F3 method performed worse, with mean errors of 8.12 ± 1.96 mm in females and 8.96 ± 2.16 mm in males. To address these limitations, we developed sex-specific multiple linear regression equations, termed Neurally-F3, which retain the measurable scalp-distance methodology of Beam-F3. Cross-validation confirmed robustness (R2 > 0.98), and validation on an independent set of 128 head models demonstrated sub-millimeter accuracy (0.19 ± 0.11 mm in females; 0.23 ± 0.14 mm in males). Neurally-F3 preserves procedural simplicity while eliminating the systematic bias of Beam-F3. These results establish Neurally-F3 as a precise, practical solution for scalp-based F3 localization with potential to improve targeting reliability in rTMS.
- 2 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessBeam-F3 error analysis and validation of Neurally-F3 equations using realistic head models
Accurate localization of the F3 point is critical for non-invasive brain stimulation, particularly in repetitive transcranial magnetic stimulation (rTMS) targeting the dorsolateral prefrontal cortex. The Beam-F3 heuristic is widely adopted due to its simplicity, yet its accuracy across realistic cranial variations has not been systematically assessed. Here, we evaluated Beam-F3 against the standard F3 location defined by the 10-20 International System using 250 realistic head models representing diverse anatomies. Beam-F3 produced significant errors, with mean deviations of 5.59 ± 1.23 mm in female models and 6.09 ± 1.52 mm in male models. The Adjusted Beam-F3 method performed worse, with mean errors of 8.12 ± 1.96 mm in females and 8.96 ± 2.16 mm in males. To address these limitations, we developed sex-specific multiple linear regression equations, termed Neurally-F3, which retain the measurable scalp-distance methodology of Beam-F3. Cross-validation confirmed robustness (R2 > 0.98), and validation on an independent set of 128 head models demonstrated sub-millimeter accuracy (0.19 ± 0.11 mm in females; 0.23 ± 0.14 mm in males). Neurally-F3 preserves procedural simplicity while eliminating the systematic bias of Beam-F3. These results establish Neurally-F3 as a precise, practical solution for scalp-based F3 localization with potential to improve targeting reliability in rTMS.
- Open Access
- 24 March 2026
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 25
Mechanics-based estimation of metabolic cost of locomotion in rehabilitation: A narrative review
The objective of this paper is to explore methodologies used to estimate the mechanical cost of locomotion and evaluate their validity as indicators of metabolic cost within rehabilitation contexts. Aging societies face rising healthcare costs and fewer workers. Remote monitoring of rehabilitation progress may help address these challenges. Because locomotion mechanics are easier to measure than metabolic cost, understanding whether mechanical cost of transport can serve as a surrogate is of interest. We conducted a systematic search for studies on mechanical work or power and metabolic energy consumption in adults under physical rehabilitation contexts. Abstract, full text screening, and data extraction were performed. Ten articles were included. We found no direct relationship between mechanical cost and metabolic cost in the included studies. However, consistent trends were observed: interventions that provided net positive work generally reduced both mechanical and metabolic costs. Similar trends were found in wheelchair propulsion, where mechanical advantage and power assistance reduced both mechanical cost and metabolic demand for wheelchair users. Rehabilitation progress can be monitored using metabolic cost, and given the observed parallel trends, mechanical cost may also serve as a practical indicator, although further research is needed to establish its validity as a surrogate.
- 24 March 2026
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 25
Open AccessMechanics-based estimation of metabolic cost of locomotion in rehabilitation: A narrative review
The objective of this paper is to explore methodologies used to estimate the mechanical cost of locomotion and evaluate their validity as indicators of metabolic cost within rehabilitation contexts. Aging societies face rising healthcare costs and fewer workers. Remote monitoring of rehabilitation progress may help address these challenges. Because locomotion mechanics are easier to measure than metabolic cost, understanding whether mechanical cost of transport can serve as a surrogate is of interest. We conducted a systematic search for studies on mechanical work or power and metabolic energy consumption in adults under physical rehabilitation contexts. Abstract, full text screening, and data extraction were performed. Ten articles were included. We found no direct relationship between mechanical cost and metabolic cost in the included studies. However, consistent trends were observed: interventions that provided net positive work generally reduced both mechanical and metabolic costs. Similar trends were found in wheelchair propulsion, where mechanical advantage and power assistance reduced both mechanical cost and metabolic demand for wheelchair users. Rehabilitation progress can be monitored using metabolic cost, and given the observed parallel trends, mechanical cost may also serve as a practical indicator, although further research is needed to establish its validity as a surrogate.
- Open Access
A PRISMA-guided systematic review of musculoskeletal modelling approaches in lower-limb cycling biomechanics
Cycling is commonly employed in sports performance, rehabilitation, and clinical contexts, while musculoskeletal (MSK) simulations enable the investigation of internal biomechanics that cannot be measured experimentally. Despite growing use, the application, validation, and standardisation of MSK simulations in cycling remain unclear. This review aimed to systematically characterise the application, validation strategies, modelling assumptions, and reporting practices of musculoskeletal simulations in lower-limb cycling biomechanics. Searches were performed in Scopus, PubMed, IEEE Xplore, and Web of Science on 1 August 2024, covering studies from January 2010 to July 2024. Peer-reviewed English-language journal articles applying MSK simulations to lower-limb cycling were included; inverse kinematics-only was excluded. No protocol was registered, and no formal risk-of-bias assessment was conducted, as there were no intervention effects and no quantitative synthesis. Twenty-eight studies met the inclusion criteria. Most of them investigated bicycle–rider configuration, neuromuscular coordination, or electrical stimulation control, with participant cohorts overwhelmingly composed of young men and minimal female representation (272 total). Model reporting was often incomplete, with wide variation in anatomical scope, inconsistent descriptions of degrees of freedom, and limited sharing of models or code. Use of experimental data was uneven across studies: while all incorporated kinematic measurements, only two-thirds included kinetic data, and only one study reported physiological measures. Model validation was generally based on literature values. Seventy-eight per cent of studies used optimisation, mainly with effort-based cost functions, and parameter variations were exploratory rather than systematic. The evidence base is limited by small, predominantly male cohorts, inconsistent reporting standards, and limited physiological validation. These results consolidate current practices and highlight the need for more transparent and open reporting, sex-balanced and clinically diverse participant representation, stronger validation, and more rigorous sensitivity analysis to enhance reproducibility and practical relevance. This review was funded by AGAUR (Spain), CAPES (Brazil) and FAP-DF (Brazil). Author summary: Cycling is widely used in sports training, rehabilitation, and clinical practice, and musculoskeletal simulations are increasingly used to study how muscles and joints work during cycling. These simulations allow us to estimate internal biomechanical variables that cannot be directly measured in experiments, such as muscle forces and joint loading. However, it is currently unclear how consistently these simulations are applied, validated, and reported across the literature. In this study, we systematically reviewed research published over the past 15 years that used musculoskeletal simulations to analyse lower-limb cycling. We identified 28 relevant studies and examined their modelling choices, experimental inputs, optimisation strategies, and validation approaches. We found substantial variability in model complexity, limited transparency in reporting, and a strong reliance on simplified literature-based validation methods. Most studies focused on narrow participant groups and explored modelling parameters in an ad hoc rather than a systematic way. Our findings highlight important gaps in current practice and point to clear opportunities for improvement. We provide an overview of common approaches and their limitations, and outline key recommendations to enhance the transparency, reproducibility, and practical relevance of musculoskeletal simulations in cycling research.
Open AccessA PRISMA-guided systematic review of musculoskeletal modelling approaches in lower-limb cycling biomechanics
Cycling is commonly employed in sports performance, rehabilitation, and clinical contexts, while musculoskeletal (MSK) simulations enable the investigation of internal biomechanics that cannot be measured experimentally. Despite growing use, the application, validation, and standardisation of MSK simulations in cycling remain unclear. This review aimed to systematically characterise the application, validation strategies, modelling assumptions, and reporting practices of musculoskeletal simulations in lower-limb cycling biomechanics. Searches were performed in Scopus, PubMed, IEEE Xplore, and Web of Science on 1 August 2024, covering studies from January 2010 to July 2024. Peer-reviewed English-language journal articles applying MSK simulations to lower-limb cycling were included; inverse kinematics-only was excluded. No protocol was registered, and no formal risk-of-bias assessment was conducted, as there were no intervention effects and no quantitative synthesis. Twenty-eight studies met the inclusion criteria. Most of them investigated bicycle–rider configuration, neuromuscular coordination, or electrical stimulation control, with participant cohorts overwhelmingly composed of young men and minimal female representation (272 total). Model reporting was often incomplete, with wide variation in anatomical scope, inconsistent descriptions of degrees of freedom, and limited sharing of models or code. Use of experimental data was uneven across studies: while all incorporated kinematic measurements, only two-thirds included kinetic data, and only one study reported physiological measures. Model validation was generally based on literature values. Seventy-eight per cent of studies used optimisation, mainly with effort-based cost functions, and parameter variations were exploratory rather than systematic. The evidence base is limited by small, predominantly male cohorts, inconsistent reporting standards, and limited physiological validation. These results consolidate current practices and highlight the need for more transparent and open reporting, sex-balanced and clinically diverse participant representation, stronger validation, and more rigorous sensitivity analysis to enhance reproducibility and practical relevance. This review was funded by AGAUR (Spain), CAPES (Brazil) and FAP-DF (Brazil). Author summary: Cycling is widely used in sports training, rehabilitation, and clinical practice, and musculoskeletal simulations are increasingly used to study how muscles and joints work during cycling. These simulations allow us to estimate internal biomechanical variables that cannot be directly measured in experiments, such as muscle forces and joint loading. However, it is currently unclear how consistently these simulations are applied, validated, and reported across the literature. In this study, we systematically reviewed research published over the past 15 years that used musculoskeletal simulations to analyse lower-limb cycling. We identified 28 relevant studies and examined their modelling choices, experimental inputs, optimisation strategies, and validation approaches. We found substantial variability in model complexity, limited transparency in reporting, and a strong reliance on simplified literature-based validation methods. Most studies focused on narrow participant groups and explored modelling parameters in an ad hoc rather than a systematic way. Our findings highlight important gaps in current practice and point to clear opportunities for improvement. We provide an overview of common approaches and their limitations, and outline key recommendations to enhance the transparency, reproducibility, and practical relevance of musculoskeletal simulations in cycling research.
- Open Access
Automated Detection of Quiet and Non-Quiet Sleep in Preterm Neonates from aEEG: Towards Predicting Brain Maturation
Background: Preterm birth is associated with an increased risk for neurodevelopmental impairments, requiring brain monitoring using amplitude-integrated electroencephalography (aEEG). While established tools detect severe dysfunction (e.g., Hellström-Westas classification), methods for assessing mild to moderate impairments—such as Burdjalov scoring or expert-based Sleep–Wake Cycle identification—are subjective and require specialized training. Automated neonatal sleep-staging models usually rely on polysomnography from term infants, a resource-intensive method rarely feasible in NICUs, where simplified single-channel aEEG is standard. Methods: aEEG recordings from 40 neurologically healthy neonates (32–42 weeks PMA) were collected and annotated for quiet (QS) and non-quiet sleep (NQS) by an expert clinician. Signals were bandpass filtered, segmented into 30 s epochs, and cleaned using impedance thresholds. 69 temporal, spectral, wavelet, EMG-inspired, and aEEG-envelope features were extracted. The 5 most relevant features were selected for QS/NQS classification using several machine-learning models validated with leave-one-subject-out cross-validation. A partial least squares model was then trained on QS-derived features to predict postmenstrual age and assess correlations with brain maturation. Results: The k-Nearest Neighbors (KNN) classifier showed the best QS/NQS discrimination, with mean Cohen’s κ = 0.69 ± 0.14 for preterm (32–37 weeks PMA) and 0.48 ± 0.21 for term infants. QS-derived features correlated strongly with postmenstrual age (PMA). The PLS model predicted PMA with an average error of 0.88 weeks (MSE = 1.33 weeks, r = 0.91), while the fully automated version using predicted QS segments yielded an error of 1.08 weeks (r = 0.86). Conclusion: Automated QS/NQS detection from single-channel aEEG is feasible in preterm neonates. Despite reduced accuracy in term infants, QS-derived features closely track brain maturation, supporting the potential of aEEG-based models for objective, early detection of neuromaturation delays in preterm infants
Open AccessAutomated Detection of Quiet and Non-Quiet Sleep in Preterm Neonates from aEEG: Towards Predicting Brain Maturation
Background: Preterm birth is associated with an increased risk for neurodevelopmental impairments, requiring brain monitoring using amplitude-integrated electroencephalography (aEEG). While established tools detect severe dysfunction (e.g., Hellström-Westas classification), methods for assessing mild to moderate impairments—such as Burdjalov scoring or expert-based Sleep–Wake Cycle identification—are subjective and require specialized training. Automated neonatal sleep-staging models usually rely on polysomnography from term infants, a resource-intensive method rarely feasible in NICUs, where simplified single-channel aEEG is standard. Methods: aEEG recordings from 40 neurologically healthy neonates (32–42 weeks PMA) were collected and annotated for quiet (QS) and non-quiet sleep (NQS) by an expert clinician. Signals were bandpass filtered, segmented into 30 s epochs, and cleaned using impedance thresholds. 69 temporal, spectral, wavelet, EMG-inspired, and aEEG-envelope features were extracted. The 5 most relevant features were selected for QS/NQS classification using several machine-learning models validated with leave-one-subject-out cross-validation. A partial least squares model was then trained on QS-derived features to predict postmenstrual age and assess correlations with brain maturation. Results: The k-Nearest Neighbors (KNN) classifier showed the best QS/NQS discrimination, with mean Cohen’s κ = 0.69 ± 0.14 for preterm (32–37 weeks PMA) and 0.48 ± 0.21 for term infants. QS-derived features correlated strongly with postmenstrual age (PMA). The PLS model predicted PMA with an average error of 0.88 weeks (MSE = 1.33 weeks, r = 0.91), while the fully automated version using predicted QS segments yielded an error of 1.08 weeks (r = 0.86). Conclusion: Automated QS/NQS detection from single-channel aEEG is feasible in preterm neonates. Despite reduced accuracy in term infants, QS-derived features closely track brain maturation, supporting the potential of aEEG-based models for objective, early detection of neuromaturation delays in preterm infants
- Open Access
- 24 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0334177
Feasibility study of a sensor-to-segment calibration method to enhance upper limb motion analysis using an IMU-based system for clinical and home environments
Inertial Measurement Units (IMUs) represent a valid alternative to standard clinical assessment methods, such as clinical scales, for evaluating upper limb kinematics. A key aspect of utilizing IMUs effectively is ensuring precise sensor-to-segment calibration, which accounts for the relative orientation between the sensor and the attached body segment. This calibration is crucial to obtain accurate results. Although reliable calibration methods are available, their application in clinical and home environments remains challenging due to their complexity. This study aimed to validate a picture-based calibration method feasible for a clinical context and compare it against other standard methods. Ten healthy subjects performed daily activity tasks while upper limb kinematics was recorded using an optoelectronic motion capture system and an IMU-based system. Four calibration methods were compared using error metrics, including root mean square deviation (RMSD) and cross-correlation (XCORR). The results demonstrate that the proposed picture-based method provides highly accurate measurements for the first and second Euler rotation angles of the shoulder, with RMSD < 15 ° and XCORR > 0.75 across most of the tasks. For the elbow joint, all calibration methods consistently yielded precise results for the first rotation (RMSD < 15 ° and XCORR > 0.95) across the majority of tasks. The proposed sensor-to-segment calibration method improves the accuracy of upper limb motion data recorded with an IMU-based system compared to traditional methods. Moreover, the calibration approach is easy to use, making it suitable for clinical and home environments.
- 24 October 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (10) , e0334177
Open AccessFeasibility study of a sensor-to-segment calibration method to enhance upper limb motion analysis using an IMU-based system for clinical and home environments
Inertial Measurement Units (IMUs) represent a valid alternative to standard clinical assessment methods, such as clinical scales, for evaluating upper limb kinematics. A key aspect of utilizing IMUs effectively is ensuring precise sensor-to-segment calibration, which accounts for the relative orientation between the sensor and the attached body segment. This calibration is crucial to obtain accurate results. Although reliable calibration methods are available, their application in clinical and home environments remains challenging due to their complexity. This study aimed to validate a picture-based calibration method feasible for a clinical context and compare it against other standard methods. Ten healthy subjects performed daily activity tasks while upper limb kinematics was recorded using an optoelectronic motion capture system and an IMU-based system. Four calibration methods were compared using error metrics, including root mean square deviation (RMSD) and cross-correlation (XCORR). The results demonstrate that the proposed picture-based method provides highly accurate measurements for the first and second Euler rotation angles of the shoulder, with RMSD < 15 ° and XCORR > 0.75 across most of the tasks. For the elbow joint, all calibration methods consistently yielded precise results for the first rotation (RMSD < 15 ° and XCORR > 0.95) across the majority of tasks. The proposed sensor-to-segment calibration method improves the accuracy of upper limb motion data recorded with an IMU-based system compared to traditional methods. Moreover, the calibration approach is easy to use, making it suitable for clinical and home environments.
- 10 September 2025
- Published by SAGE Publications in International Journal of Mechanical Engineering Education
Analysis of a methodology for engineering education based on service-learning projects for ecological and social entities while using conceive, design, implement and operate phases
This study analyzes the integration of Service-Learning (SL) within the CDIO (Conceive, Design, Implement, Operate) framework in mechanical engineering education to develop technical competencies alongside civic responsibility and interdisciplinary collaboration. It addresses two research questions: (1) How does the integration of SL and CDIO impact students’ technical competencies, professional skills, and civic engagement? and (2) Does collaboration between universities, vocational schools, and community organizations enhance student learning and project outcomes? A mixed-methods case study involved 61 third-year mechanical engineering students (11.5% female; ages 20–23) from a public university and 27 male vocational students (ages 17–19) from industrial training programs. In partnership with ecological and social organizations, students co-developed engineering prototypes tackling invasive aquatic turtles, coastal microplastics, and cerebral palsy rehabilitation. Survey data and student feedback indicate that combining SL with CDIO significantly enhanced technical application, teamwork, and societal engagement. Groups incorporating feedback from vocational partners showed greater satisfaction and closer alignment with CDIO principles. Challenges included time constraints, limited feedback loops, and inconsistent integration of sustainability. The findings support the effectiveness of a socially responsive engineering education model and recommend improvements in interdisciplinary coordination, time management, and sustainability integration for future iterations.
- 10 September 2025
- Published by SAGE Publications in International Journal of Mechanical Engineering Education
Analysis of a methodology for engineering education based on service-learning projects for ecological and social entities while using conceive, design, implement and operate phases
This study analyzes the integration of Service-Learning (SL) within the CDIO (Conceive, Design, Implement, Operate) framework in mechanical engineering education to develop technical competencies alongside civic responsibility and interdisciplinary collaboration. It addresses two research questions: (1) How does the integration of SL and CDIO impact students’ technical competencies, professional skills, and civic engagement? and (2) Does collaboration between universities, vocational schools, and community organizations enhance student learning and project outcomes? A mixed-methods case study involved 61 third-year mechanical engineering students (11.5% female; ages 20–23) from a public university and 27 male vocational students (ages 17–19) from industrial training programs. In partnership with ecological and social organizations, students co-developed engineering prototypes tackling invasive aquatic turtles, coastal microplastics, and cerebral palsy rehabilitation. Survey data and student feedback indicate that combining SL with CDIO significantly enhanced technical application, teamwork, and societal engagement. Groups incorporating feedback from vocational partners showed greater satisfaction and closer alignment with CDIO principles. Challenges included time constraints, limited feedback loops, and inconsistent integration of sustainability. The findings support the effectiveness of a socially responsive engineering education model and recommend improvements in interdisciplinary coordination, time management, and sustainability integration for future iterations.
- Open Access
- 29 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Síntesis de un mecanismo flexible como pata de un robot caminador
Los mecanismos rígidos tradicionales presentan limitaciones como desgaste mecánico, holgura, mayor número de piezas, peso elevado, costo y tiempo de ensamblaje prolongados, así como la necesidad de mantenimiento regular. La reducción de estos inconvenientes permite mejorar el rendimiento, la eficiencia y la viabilidad económica de los sistemas mecánicos. Los mecanismos flexibles han demostrado ser una alternativa prometedora en múltiples disciplinas, incluyendo biomecánica, robótica y electrónica, al basar su movimiento en la flexión controlada de sus elementos en lugar de depender de articulaciones cinemáticas convencionales. No obstante, el desafío radica en seleccionar y optimizar la geometría y configuración de las uniones flexibles para cada aplicación específica. Este trabajo se centra en el diseño y la síntesis de un mecanismo flexible destinado a actuar como pata de un robot caminador, orientado a aplicaciones donde la adaptabilidad y la eficiencia energética son esenciales. Se propone un diseño inspirado en mecanismos de flexión controlada, que combina elementos elásticos con estructuras rígidas, permitiendo una amortiguación pasiva y adaptativa al terreno. La metodología se basa en la integración de materiales de baja rigidez y geometrías especializadas, que proporcionan al mecanismo una capacidad de movimiento de múltiples grados de libertad sin necesidad de actuadores adicionales. Para lograrlo, se analizan distintos enfoques de diseño bioinspirados, aplicando principios de síntesis de mecanismos y optimización estructural, con el fin de obtener un balance entre estabilidad y flexibilidad en las distintas fases del ciclo de marcha del robot. Los resultados de simulaciones y pruebas experimentales confirman que el mecanismo propuesto mejora la locomoción autónoma en terrenos irregulares sin la complejidad de sistemas de control avanzados. Con este desarrollo, se propone una alternativa innovadora para la locomoción robótica con potencial aplicación en robots de exploración y rescate que requieren movilidad autónoma en entornos impredecibles. Este proyecto aborda el diseño y la síntesis de un mecanismo flexible destinado a funcionar como pata de un robot caminador, orientado a aplicaciones donde la adaptabilidad y la eficiencia energética son esenciales. Se propone un diseño inspirado en mecanismos de flexión controlada, que combina elementos elásticos con estructuras rígidas, permitiendo una amortiguación pasiva y adaptativa al terreno. La metodología se basa en la integración de materiales de baja rigidez y geometrías especializadas, que proporcionan al mecanismo una capacidad de movimiento en múltiples grados de libertad sin necesidad de actuadores complejos. Para lograrlo, se analizan distintos enfoques de diseño bioinspirados, aplicando principios de síntesis de mecanismos y optimización estructural, con el fin de obtener un balance entre estabilidad y flexibilidad en las distintas fases del ciclo de marcha del robot. Con este desarrollo, se propone una alternativa innovadora para la locomoción robótica con potencial aplicación en robots de exploración y rescate que requieren movilidad autónoma en entornos impredecibles.
- 29 May 2025
- Published by Asociación Española de Ingeniería Mecánica (AEIM) in Anales de Ingeniería Mecánica
- Vol. 1 (24)
Open AccessSíntesis de un mecanismo flexible como pata de un robot caminador
Los mecanismos rígidos tradicionales presentan limitaciones como desgaste mecánico, holgura, mayor número de piezas, peso elevado, costo y tiempo de ensamblaje prolongados, así como la necesidad de mantenimiento regular. La reducción de estos inconvenientes permite mejorar el rendimiento, la eficiencia y la viabilidad económica de los sistemas mecánicos. Los mecanismos flexibles han demostrado ser una alternativa prometedora en múltiples disciplinas, incluyendo biomecánica, robótica y electrónica, al basar su movimiento en la flexión controlada de sus elementos en lugar de depender de articulaciones cinemáticas convencionales. No obstante, el desafío radica en seleccionar y optimizar la geometría y configuración de las uniones flexibles para cada aplicación específica. Este trabajo se centra en el diseño y la síntesis de un mecanismo flexible destinado a actuar como pata de un robot caminador, orientado a aplicaciones donde la adaptabilidad y la eficiencia energética son esenciales. Se propone un diseño inspirado en mecanismos de flexión controlada, que combina elementos elásticos con estructuras rígidas, permitiendo una amortiguación pasiva y adaptativa al terreno. La metodología se basa en la integración de materiales de baja rigidez y geometrías especializadas, que proporcionan al mecanismo una capacidad de movimiento de múltiples grados de libertad sin necesidad de actuadores adicionales. Para lograrlo, se analizan distintos enfoques de diseño bioinspirados, aplicando principios de síntesis de mecanismos y optimización estructural, con el fin de obtener un balance entre estabilidad y flexibilidad en las distintas fases del ciclo de marcha del robot. Los resultados de simulaciones y pruebas experimentales confirman que el mecanismo propuesto mejora la locomoción autónoma en terrenos irregulares sin la complejidad de sistemas de control avanzados. Con este desarrollo, se propone una alternativa innovadora para la locomoción robótica con potencial aplicación en robots de exploración y rescate que requieren movilidad autónoma en entornos impredecibles. Este proyecto aborda el diseño y la síntesis de un mecanismo flexible destinado a funcionar como pata de un robot caminador, orientado a aplicaciones donde la adaptabilidad y la eficiencia energética son esenciales. Se propone un diseño inspirado en mecanismos de flexión controlada, que combina elementos elásticos con estructuras rígidas, permitiendo una amortiguación pasiva y adaptativa al terreno. La metodología se basa en la integración de materiales de baja rigidez y geometrías especializadas, que proporcionan al mecanismo una capacidad de movimiento en múltiples grados de libertad sin necesidad de actuadores complejos. Para lograrlo, se analizan distintos enfoques de diseño bioinspirados, aplicando principios de síntesis de mecanismos y optimización estructural, con el fin de obtener un balance entre estabilidad y flexibilidad en las distintas fases del ciclo de marcha del robot. Con este desarrollo, se propone una alternativa innovadora para la locomoción robótica con potencial aplicación en robots de exploración y rescate que requieren movilidad autónoma en entornos impredecibles.