Ryuichi Azuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryuichi Azuma has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Masato Tsuchiya
Department of Plastic and Reconstructive Surgery, National Defense Medical College, Saitama 359-8513, Japan
6 shared publications - Akio Horiguchi
Center for Trauma, Burn and Tactical Medicine National Defense Medical College Hospital Saitama Japan
5 shared publications Kenichiro Ojima
Department of Urology National Defense Medical College Saitama Japan
4 shared publications- Masayuki Shinchi
Department of Urology National Defense Medical College Saitama Japan
4 shared publications Tomoharu Kiyosawa
Departments of Department of Plastic Surgery National Defense Medical College Tokorozawa Saitama Japan
4 shared publications- Keiichi Ito
Department of Urology National Defense Medical College Saitama Japan
3 shared publications
Latest Publications
- Open Access
- 4 March 2026
- Published by Elsevier in JPRAS Open
- Vol. 49, 239-244
Delayed-onset maxillary sinus–cutaneous fistula of the lower eyelid following zygomatic implant removal: A case report
- 4 March 2026
- Published by Elsevier in JPRAS Open
- Vol. 49, 239-244
Open AccessDelayed-onset maxillary sinus–cutaneous fistula of the lower eyelid following zygomatic implant removal: A case report
- Open Access
- 9 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12963
Preliminary Study on the Accuracy Comparison Between 3D-Printed Bone Models and Naked-Eye Stereoscopy-Based Virtual Reality Models for Presurgical Molding in Orbital Floor Fracture Repair
Three-dimensional (3D) printing enables accurate implant pre-shaping in orbital reconstruction but is costly and time-consuming. Naked-eye stereoscopic displays (NEDs) enable virtual implant modeling without fabrication. This study aimed to compare the reproducibility and accuracy of NED-based virtual reality (VR) pre-shaping with conventional 3D-printed models. Two surgeons pre-shaped implants for 11 unilateral orbital floor fractures using both 3D-printed and NED-based VR models with identical computed tomography data. The depth, area, and axis dimensions were measured, and reproducibility and agreement were assessed using intraclass correlation coefficients (ICCs), Bland–Altman analysis, and shape similarity metrics—Hausdorff distance (HD) and root mean square error (RMSE). Intra-rater ICCs were ≥0.80 for all parameters except depth in the VR model. The HD and RMSE reveal no significant differences between 3D (2.64 ± 0.85 mm; 1.02 ± 0.42 mm) and VR (3.14 ± 1.18 mm; 1.24 ± 0.53 mm). Inter-rater ICCs were ≥0.80 for the area and axes in both modalities, while depth remained low. Between modalities, no significant differences were found; HD and RMSE were 2.95 ± 0.94 mm and 1.28 ± 0.49 mm. The NED-based VR pre-shaping achieved reproducibility and dimensional agreement comparable to 3D printing, suggesting a feasible cost- and time-efficient alternative for orbital reconstruction. These preliminary findings suggest that NED-based preshaping may be feasible; however, larger studies are required to confirm whether VR can achieve performance comparable to 3D-printed models.
- 9 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (24) , 12963
Open AccessPreliminary Study on the Accuracy Comparison Between 3D-Printed Bone Models and Naked-Eye Stereoscopy-Based Virtual Reality Models for Presurgical Molding in Orbital Floor Fracture Repair
Three-dimensional (3D) printing enables accurate implant pre-shaping in orbital reconstruction but is costly and time-consuming. Naked-eye stereoscopic displays (NEDs) enable virtual implant modeling without fabrication. This study aimed to compare the reproducibility and accuracy of NED-based virtual reality (VR) pre-shaping with conventional 3D-printed models. Two surgeons pre-shaped implants for 11 unilateral orbital floor fractures using both 3D-printed and NED-based VR models with identical computed tomography data. The depth, area, and axis dimensions were measured, and reproducibility and agreement were assessed using intraclass correlation coefficients (ICCs), Bland–Altman analysis, and shape similarity metrics—Hausdorff distance (HD) and root mean square error (RMSE). Intra-rater ICCs were ≥0.80 for all parameters except depth in the VR model. The HD and RMSE reveal no significant differences between 3D (2.64 ± 0.85 mm; 1.02 ± 0.42 mm) and VR (3.14 ± 1.18 mm; 1.24 ± 0.53 mm). Inter-rater ICCs were ≥0.80 for the area and axes in both modalities, while depth remained low. Between modalities, no significant differences were found; HD and RMSE were 2.95 ± 0.94 mm and 1.28 ± 0.49 mm. The NED-based VR pre-shaping achieved reproducibility and dimensional agreement comparable to 3D printing, suggesting a feasible cost- and time-efficient alternative for orbital reconstruction. These preliminary findings suggest that NED-based preshaping may be feasible; however, larger studies are required to confirm whether VR can achieve performance comparable to 3D-printed models.
- Open Access
- 3 November 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (11) , 409
Pre-Vascularized 3-Dimensional Skin Substitutes Promote Angiogenesis and Tissue Repair in a Murine Model of Refractory Skin Ulcers
Restoring blood flow is crucial for treating refractory ulcers. Despite advancements in various biomaterials, none incorporating pre-formed blood vessels have been commercialized. To address this, we developed a pre-vascularized three-dimensional (3D) skin substitute (PV-3D skin) designed to enhance healing when treating refractory ulcers. This study aimed to evaluate the therapeutic role of PV-3D skin transplantation in refractory ulcer models, induced by applying mitomycin C to wounds in severe immunodeficient mice. The wounds were then treated with PV-3D skin, non-vascularized 3D skin, skin grafts, or wound dressings. The PV-3D skin group demonstrated healing dynamics comparable to those of the skin graft group, with similar tissue morphology and wound temperature changes. Furthermore, at day 7 post-transplantation, the PV-3D skin group demonstrated significantly higher hypoxia-inducible factor 1-alpha expression levels compared to the 3D skin group. By day 14, the PV-3D skin group exhibited a significantly larger vascular area compared to the 3D skin group. Notably, PV-3D skin treatment stimulated host-derived angiogenesis, thereby enhancing wound healing and reducing the recurrence of refractory ulcers. These results suggest that PV-3D skin transplantation offers a promising therapeutic approach for refractory ulcers, especially in terms of angiogenesis.
- 3 November 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (11) , 409
Open AccessPre-Vascularized 3-Dimensional Skin Substitutes Promote Angiogenesis and Tissue Repair in a Murine Model of Refractory Skin Ulcers
Restoring blood flow is crucial for treating refractory ulcers. Despite advancements in various biomaterials, none incorporating pre-formed blood vessels have been commercialized. To address this, we developed a pre-vascularized three-dimensional (3D) skin substitute (PV-3D skin) designed to enhance healing when treating refractory ulcers. This study aimed to evaluate the therapeutic role of PV-3D skin transplantation in refractory ulcer models, induced by applying mitomycin C to wounds in severe immunodeficient mice. The wounds were then treated with PV-3D skin, non-vascularized 3D skin, skin grafts, or wound dressings. The PV-3D skin group demonstrated healing dynamics comparable to those of the skin graft group, with similar tissue morphology and wound temperature changes. Furthermore, at day 7 post-transplantation, the PV-3D skin group demonstrated significantly higher hypoxia-inducible factor 1-alpha expression levels compared to the 3D skin group. By day 14, the PV-3D skin group exhibited a significantly larger vascular area compared to the 3D skin group. Notably, PV-3D skin treatment stimulated host-derived angiogenesis, thereby enhancing wound healing and reducing the recurrence of refractory ulcers. These results suggest that PV-3D skin transplantation offers a promising therapeutic approach for refractory ulcers, especially in terms of angiogenesis.
- Open Access
- 12 June 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (6) , 381
Evaluation of Smartphones Equipped with Light Detection and Ranging Technology for Circumferential and Volumetric Measurements in Lower Extremity Lymphedema
Lower extremity lymphedema (LEL) requires precise limb measurements for treatment evaluation and compression garment design. Tape measurement (TM) is the standard method but is time-consuming. Smartphones with light detection and ranging (LiDAR) technology may offer fast and efficient alternatives for three-dimensional imaging and measurement. This study evaluated the accuracy, reliability, and time efficiency of LiDAR measurements compared with those of TM in patients with LEL. A healthy volunteer and 55 patients were included. Circumferences of the foot, ankle, calf, knee, and thigh and the volume were measured using TM and smartphones with LiDAR. The water displacement method was used to validate volume measurements. The measurement time, reliability, correlation, agreement, and systematic differences between the methods were assessed. LiDAR showed excellent reliability in the healthy volunteer (inter-rater intraclass correlation coefficients: 0.960–0.988) and significantly reduced the measurement time compared with TM (64.0 ± 15.1 vs. 115.3 ± 30.6 s). In patients with LEL, strong correlations and agreements were observed for ankle, calf, and knee measurements. However, foot and thigh measurements showed lower correlations and larger discrepancies. LiDAR has excellent accuracy and reliability in measuring the circumference and volume of the lower leg and has the potential to reduce the time required to acquire data. Limitations include lower accuracy for foot and thigh measurements and the current workflow complexity, which requires the use of multiple software tools.
- 12 June 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (6) , 381
Open AccessEvaluation of Smartphones Equipped with Light Detection and Ranging Technology for Circumferential and Volumetric Measurements in Lower Extremity Lymphedema
Lower extremity lymphedema (LEL) requires precise limb measurements for treatment evaluation and compression garment design. Tape measurement (TM) is the standard method but is time-consuming. Smartphones with light detection and ranging (LiDAR) technology may offer fast and efficient alternatives for three-dimensional imaging and measurement. This study evaluated the accuracy, reliability, and time efficiency of LiDAR measurements compared with those of TM in patients with LEL. A healthy volunteer and 55 patients were included. Circumferences of the foot, ankle, calf, knee, and thigh and the volume were measured using TM and smartphones with LiDAR. The water displacement method was used to validate volume measurements. The measurement time, reliability, correlation, agreement, and systematic differences between the methods were assessed. LiDAR showed excellent reliability in the healthy volunteer (inter-rater intraclass correlation coefficients: 0.960–0.988) and significantly reduced the measurement time compared with TM (64.0 ± 15.1 vs. 115.3 ± 30.6 s). In patients with LEL, strong correlations and agreements were observed for ankle, calf, and knee measurements. However, foot and thigh measurements showed lower correlations and larger discrepancies. LiDAR has excellent accuracy and reliability in measuring the circumference and volume of the lower leg and has the potential to reduce the time required to acquire data. Limitations include lower accuracy for foot and thigh measurements and the current workflow complexity, which requires the use of multiple software tools.
- Open Access
- 19 July 2024
- Published by Wiley in Skin Research and Technology
- Vol. 30 (7) , e13865
Continuous negative‐pressure wound therapy improves the survival rate of skin grafts and shortens the time required for skin graft survival
Background: The effectiveness of negative‐pressure wound therapy (NPWT) in skin graft fixation has been demonstrated in several clinical studies. However, in vitro and in vivo studies on skin graft fixation with NPWT have been scarce. In this in vivo study, we aimed to determine whether NPWT fixation enhances skin graft survival and how it contributes to improving skin graft survival biologically. Materials and methods: We harvested skin from the bilateral abdominal wall of 88 mice after anesthetizing them. Full‐thickness skin grafts (FTSGs) were performed on contralateral harvest sites, and grafts were fixed using NPWT (continuous and intermittent modes), conventional compression methods, and wrapping with polyurethane foam as a control group. On days 5 and 10 of grafting, the survival rates of the FTSGs were evaluated. Immunohistopathological analysis and measurement of the expression levels of vascular endothelial growth factor (VEGF), basic fibroblast growth factor (FGF‐2), and epidermal growth factor (EGF) were performed. Results: The survival rates of FTSG in the continuous NPWT group were significantly higher than those in the other groups. The number of capillaries in the dermis was significantly higher in the continuous NPWT group than in the other groups. In the wound bed, VEGF levels were significantly higher in both NPWT groups than in the other groups. Conclusion: Continuous NPWT increases the survival rate of FTSGs and shortens the duration of skin graft survival.
- 19 July 2024
- Published by Wiley in Skin Research and Technology
- Vol. 30 (7) , e13865
Open AccessContinuous negative‐pressure wound therapy improves the survival rate of skin grafts and shortens the time required for skin graft survival
Background: The effectiveness of negative‐pressure wound therapy (NPWT) in skin graft fixation has been demonstrated in several clinical studies. However, in vitro and in vivo studies on skin graft fixation with NPWT have been scarce. In this in vivo study, we aimed to determine whether NPWT fixation enhances skin graft survival and how it contributes to improving skin graft survival biologically. Materials and methods: We harvested skin from the bilateral abdominal wall of 88 mice after anesthetizing them. Full‐thickness skin grafts (FTSGs) were performed on contralateral harvest sites, and grafts were fixed using NPWT (continuous and intermittent modes), conventional compression methods, and wrapping with polyurethane foam as a control group. On days 5 and 10 of grafting, the survival rates of the FTSGs were evaluated. Immunohistopathological analysis and measurement of the expression levels of vascular endothelial growth factor (VEGF), basic fibroblast growth factor (FGF‐2), and epidermal growth factor (EGF) were performed. Results: The survival rates of FTSG in the continuous NPWT group were significantly higher than those in the other groups. The number of capillaries in the dermis was significantly higher in the continuous NPWT group than in the other groups. In the wound bed, VEGF levels were significantly higher in both NPWT groups than in the other groups. Conclusion: Continuous NPWT increases the survival rate of FTSGs and shortens the duration of skin graft survival.
- Open Access
- 4 April 2024
- Published by MDPI AG in Société Internationale d’Urologie Journal
- Vol. 5 (2) , 85-92
Is the Bulbar Urethral Stricture a Single and Uniform Disease?
Objectives: Proximal and distal bulbar urethral strictures (BUS) have different disease characteristics and require different treatment strategies despite being regarded as a single condition. To clarify the differences, we analyzed our database by distinguishing the two types of BUS. Methods: We retrospectively reviewed the data of 196 patients with BUS who underwent urethroplasty at the National Defense Medical College (Japan) between August 2004 and March 2022. We divided patients into proximal (group 1) or distal (group 2) groups based on the stricture segment and compared patient background and surgical techniques for each group. We assessed whether the stricture segment was an independent predictive factor for substitution urethroplasty selection using multivariate logistic regression analysis. The recurrence rates were calculated and compared using the Kaplan–Meier method and log-rank test, respectively. Results: Patients in group 1 had a less frequent non-obliterated lumen (73% vs. 94%, p = 0.020) and significantly shorter strictures (10 mm vs. 23 mm, p < 0.001) more frequently caused by external traumas (47% vs. 26%, p = 0.010) than those in group 2. Logistic regression analysis revealed that the stricture segment (distal) (p < 0.001), stricture length (≥20 mm) (p < 0.001), ≥2 prior transurethral procedures (p = 0.030), and a non-obliterated lumen (p = 0.020) were independent predictive factors for substitution urethroplasty. However, the recurrence rate (p = 0.18) did not significantly differ between the two groups. Conclusions: Proximal and distal BUS have substantially different anatomical characteristics and etiologies and require different reconstructive techniques.
- 4 April 2024
- Published by MDPI AG in Société Internationale d’Urologie Journal
- Vol. 5 (2) , 85-92
Open AccessIs the Bulbar Urethral Stricture a Single and Uniform Disease?
Objectives: Proximal and distal bulbar urethral strictures (BUS) have different disease characteristics and require different treatment strategies despite being regarded as a single condition. To clarify the differences, we analyzed our database by distinguishing the two types of BUS. Methods: We retrospectively reviewed the data of 196 patients with BUS who underwent urethroplasty at the National Defense Medical College (Japan) between August 2004 and March 2022. We divided patients into proximal (group 1) or distal (group 2) groups based on the stricture segment and compared patient background and surgical techniques for each group. We assessed whether the stricture segment was an independent predictive factor for substitution urethroplasty selection using multivariate logistic regression analysis. The recurrence rates were calculated and compared using the Kaplan–Meier method and log-rank test, respectively. Results: Patients in group 1 had a less frequent non-obliterated lumen (73% vs. 94%, p = 0.020) and significantly shorter strictures (10 mm vs. 23 mm, p < 0.001) more frequently caused by external traumas (47% vs. 26%, p = 0.010) than those in group 2. Logistic regression analysis revealed that the stricture segment (distal) (p < 0.001), stricture length (≥20 mm) (p < 0.001), ≥2 prior transurethral procedures (p = 0.030), and a non-obliterated lumen (p = 0.020) were independent predictive factors for substitution urethroplasty. However, the recurrence rate (p = 0.18) did not significantly differ between the two groups. Conclusions: Proximal and distal BUS have substantially different anatomical characteristics and etiologies and require different reconstructive techniques.
- Open Access
- 29 June 2023
- Published by Taylor & Francis in Case Reports in Plastic Surgery and Hand Surgery
- Vol. 10 (1) , 2228887
Mixed lesion of traumatic pseudoaneurysm and pyogenic granuloma on a digit
Traumatic aneurysms occurring in the digit are extremely rare. We report a case of a traumatic pseudoaneurysm arising from a terminal branch of the finger artery and presenting as a mixed lesion with pyogenic granuloma that was exposed to the outside of the body and treated surgically.
- 29 June 2023
- Published by Taylor & Francis in Case Reports in Plastic Surgery and Hand Surgery
- Vol. 10 (1) , 2228887
Open AccessMixed lesion of traumatic pseudoaneurysm and pyogenic granuloma on a digit
Traumatic aneurysms occurring in the digit are extremely rare. We report a case of a traumatic pseudoaneurysm arising from a terminal branch of the finger artery and presenting as a mixed lesion with pyogenic granuloma that was exposed to the outside of the body and treated surgically.
- Open Access
- 21 June 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (9) , 3041-3045
Lymphoscintigraphy with single-photon emission computerized tomography/computed tomography for evaluating lymphatic leakage following pelvic and para-aortic lymphadenectomy
- 21 June 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (9) , 3041-3045
Open AccessLymphoscintigraphy with single-photon emission computerized tomography/computed tomography for evaluating lymphatic leakage following pelvic and para-aortic lymphadenectomy
- 16 March 2023
- Published by Springer Nature
- p. 131-152
Negative-Pressure Wound Therapy: What We Know and What We Need to Know
Negative-pressure wound therapy (NPWT) promotes wound healing by applying negative pressure to the wound surface. A quarter of a century after its introduction, NPWT has been used in various clinical conditions, although molecular biological evidence is insufficient due to delay in basic research. Here, we have summarized the history of NPWT, its mechanism of action, what is currently known about it, and what is expected to be known in the future. Particularly, attention has shifted from the four main mechanisms of NPWT to the accompanying secondary effects, such as effects on various cells, bacteria, and surgical wounds. This chapter will help the reader to understand the current status and shortcomings of NPWT-related research, which could aid in the development of basic research and, eventually, clinical use with stronger scientific evidence. Keywords Angiogenesis Biofilm Epithelial-mesenchymal transition Mechanotransduction Microdeformational wound therapy Surgical site infection Topical negative pressure Vacuum-assisted closure Vacuum sealing drainage Wound healing
- 16 March 2023
- Published by Springer Nature
- p. 131-152
Negative-Pressure Wound Therapy: What We Know and What We Need to Know
Negative-pressure wound therapy (NPWT) promotes wound healing by applying negative pressure to the wound surface. A quarter of a century after its introduction, NPWT has been used in various clinical conditions, although molecular biological evidence is insufficient due to delay in basic research. Here, we have summarized the history of NPWT, its mechanism of action, what is currently known about it, and what is expected to be known in the future. Particularly, attention has shifted from the four main mechanisms of NPWT to the accompanying secondary effects, such as effects on various cells, bacteria, and surgical wounds. This chapter will help the reader to understand the current status and shortcomings of NPWT-related research, which could aid in the development of basic research and, eventually, clinical use with stronger scientific evidence. Keywords Angiogenesis Biofilm Epithelial-mesenchymal transition Mechanotransduction Microdeformational wound therapy Surgical site infection Topical negative pressure Vacuum-assisted closure Vacuum sealing drainage Wound healing
- 12 September 2022
- Published by Wiley in International Journal of Urology
- Vol. 29 (12) , 1511-1516
Transperineal bulbovesical anastomosis for extensive posterior urethral stenoses after treatment of prostatic disease
Objectives: We report our surgical experience of transperineal bulbovesical anastomosis (BVA) for extensive posterior urethral stenosis (PUS).Methods: Six male patients who had extensive PUS extending from the bulbomembranous urethra to the bladder neck due to prostatic disease treatment and underwent transperineal BVA between 2014 and 2020 were retrospectively reviewed. BVA was performed according to the elaborate perineal approach for pelvic fracture urethral repair with minor modifications. After confirming the absence of recurrent stenosis 6 months postoperatively, the patients were offered artificial urinary sphincter (AUS) placement for subsequent urinary incontinence (UI).Results: Median patient age was 68, and the etiology of PUS was radical prostatectomy for prostate cancer in four patients, brachytherapy for prostate cancer in one, and transurethral resection of the prostate for benign prostatic hyperplasia in one. All patients had been previously treated with multiple transurethral procedures such as urethrotomy and dilation. Median operative time and blood loss were 211 min and 154 ml, respectively. Five cases (83.3%) had no recurrent stenosis with a median follow‐up of 45 months, but a single direct vision internal urethrotomy was performed in one (16.7%) due to restenosis. Four (66.7%) patients underwent AUS placement via transcorporal approach for subsequent UI, but two had it removed due to urethral erosion.Conclusion: Transperineal BVA could effectively manage extensive PUS after prostatic disease treatment. Staged AUS placement could be a viable option for subsequent UI, but the risk of urethral erosion seemed high.
- 12 September 2022
- Published by Wiley in International Journal of Urology
- Vol. 29 (12) , 1511-1516
Transperineal bulbovesical anastomosis for extensive posterior urethral stenoses after treatment of prostatic disease
Objectives: We report our surgical experience of transperineal bulbovesical anastomosis (BVA) for extensive posterior urethral stenosis (PUS).Methods: Six male patients who had extensive PUS extending from the bulbomembranous urethra to the bladder neck due to prostatic disease treatment and underwent transperineal BVA between 2014 and 2020 were retrospectively reviewed. BVA was performed according to the elaborate perineal approach for pelvic fracture urethral repair with minor modifications. After confirming the absence of recurrent stenosis 6 months postoperatively, the patients were offered artificial urinary sphincter (AUS) placement for subsequent urinary incontinence (UI).Results: Median patient age was 68, and the etiology of PUS was radical prostatectomy for prostate cancer in four patients, brachytherapy for prostate cancer in one, and transurethral resection of the prostate for benign prostatic hyperplasia in one. All patients had been previously treated with multiple transurethral procedures such as urethrotomy and dilation. Median operative time and blood loss were 211 min and 154 ml, respectively. Five cases (83.3%) had no recurrent stenosis with a median follow‐up of 45 months, but a single direct vision internal urethrotomy was performed in one (16.7%) due to restenosis. Four (66.7%) patients underwent AUS placement via transcorporal approach for subsequent UI, but two had it removed due to urethral erosion.Conclusion: Transperineal BVA could effectively manage extensive PUS after prostatic disease treatment. Staged AUS placement could be a viable option for subsequent UI, but the risk of urethral erosion seemed high.