TCTom Chau

Tom Chau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tom Chau has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Point-of-care artificial intelligence-enabled ECG for dyskalemia: a retrospective cohort analysis for accuracy and outcome prediction

    by Chin Lin, Tom Chau, Chin-Sheng Lin, Hung-Sheng Shang, Wen-Hui Fang, Ding-Jie Lee, Chia-Cheng Lee, Shi-Hung Tsai, Chih-Hung Wang, Shih-Hua Lin

    Dyskalemias are common electrolyte disorders associated with high cardiovascular risk. Artificial intelligence (AI)-assisted electrocardiography (ECG) has been evaluated as an early-detection approach for dyskalemia. The aims of this study were to determine the clinical accuracy of AI-assisted ECG for dyskalemia and prognostic ability on clinical outcomes such as all-cause mortality, hospitalizations, and ED revisits. This retrospective cohort study was done at two hospitals within a health system from May 2019 to December 2020. In total, 26,499 patients with 34,803 emergency department (ED) visits to an academic medical center and 6492 ED visits from 4747 patients to a community hospital who had a 12-lead ECG to estimate ECG-K+ and serum laboratory potassium measurement (Lab-K+) within 1 h were included. ECG-K+ had mean absolute errors (MAEs) of ≤0.365 mmol/L. Area under receiver operating characteristic curves for ECG-K+ to predict moderate-to-severe hypokalemia (Lab-K+ ≤3 mmol/L) and moderate-to-severe hyperkalemia (Lab-K+ ≥ 6 mmol/L) were >0.85 and >0.95, respectively. The U-shaped relationships between K+ concentration and adverse outcomes were more prominent for ECG-K+ than for Lab-K+. ECG-K+ and Lab-K+ hyperkalemia were associated with high HRs for 30-day all-cause mortality. Compared to hypokalemic Lab-K+, patients with hypokalemic ECG-K+ had significantly higher risk for adverse outcomes after full confounder adjustment. In addition, patients with normal Lab-K+ but dyskalemic ECG-K+ (pseudo-positive) also exhibited more co-morbidities and had worse outcomes. Point-of-care bloodless AI ECG-K+ not only rapidly identified potentially severe hypo- and hyperkalemia, but also may serve as a biomarker for medical complexity and an independent predictor for adverse outcomes.


  • Open Access

    Artificial Intelligence–Assisted Electrocardiography for Early Diagnosis of Thyrotoxic Periodic Paralysis

    by Chin-Sheng Lin, Ding-Jie Lee, Chia-Cheng Lee, Sy-Jou Chen, Shi-Hung Tsai, Feng-Chih Kuo, Tom Chau, Shih-Hua Lin

    Context Thyrotoxic periodic paralysis (TPP) characterized by acute weakness, hypokalemia, and hyperthyroidism is a medical emergency with a great challenge in early diagnosis since most TPP patients do not have overt symptoms. Objective This work aims to assess artificial intelligence (AI)-assisted electrocardiography (ECG) combined with routine laboratory data in the early diagnosis of TPP. Methods A deep learning model (DLM) based on ECG12Net, an 82-layer convolutional neural network, was constructed to detect hypokalemia and hyperthyroidism. The development cohort consisted of 39 ECGs from patients with TPP and 502 ECGs of hypokalemic controls; the validation cohort consisted of 11 ECGs of TPP patients and 36 ECGs of non-TPP individuals with weakness. The AI-ECG–based TPP diagnostic process was then consecutively evaluated in 22 male patients with TTP-like features. Results In the validation cohort, the DLM-based ECG system detected all cases of hypokalemia in TPP patients with a mean absolute error of 0.26 mEq/L and diagnosed TPP with an area under curve (AUC) of approximately 80%, surpassing the best standard ECG parameter (AUC = 0.7285 for the QR interval). Combining the AI predictions with the estimated glomerular filtration rate and serum chloride boosted the diagnostic accuracy of the algorithm to AUC 0.986. In the prospective study, the integrated AI and routine laboratory diagnostic system had a PPV of 100% and F-measure of 87.5%. Conclusion An AI-ECG system reliably identifies hypokalemia in patients with paralysis, and integration with routine blood chemistries provides valuable decision support for the early diagnosis of TPP.


  • Open Access

    A Deep-Learning Algorithm (ECG12Net) for Detecting Hypokalemia and Hyperkalemia by Electrocardiography: Algorithm Development

    by Chin-Sheng Lin, Chin Lin, Wen-Hui Fang, Chia-Jung Hsu, Sy-Jou Chen, Kuo-Hua Huang, Wei-Shiang Lin, Chien-Sung Tsai, Chih-Chun Kuo, Tom Chau, et al.

    Background: The detection of dyskalemias—hypokalemia and hyperkalemia—currently depends on laboratory tests. Since cardiac tissue is very sensitive to dyskalemia, electrocardiography (ECG) may be able to uncover clinically important dyskalemias before laboratory results. Objective: Our study aimed to develop a deep-learning model, ECG12Net, to detect dyskalemias based on ECG presentations and to evaluate the logic and performance of this model. Methods: Spanning from May 2011 to December 2016, 66,321 ECG records with corresponding serum potassium (K+) concentrations were obtained from 40,180 patients admitted to the emergency department. ECG12Net is an 82-layer convolutional neural network that estimates serum K+ concentration. Six clinicians—three emergency physicians and three cardiologists—participated in human-machine competition. Sensitivity, specificity, and balance accuracy were used to evaluate the performance of ECG12Net with that of these physicians. Results: In a human-machine competition including 300 ECGs of different serum K+ concentrations, the area under the curve for detecting hypokalemia and hyperkalemia with ECG12Net was 0.926 and 0.958, respectively, which was significantly better than that of our best clinicians. Moreover, in detecting hypokalemia and hyperkalemia, the sensitivities were 96.7% and 83.3%, respectively, and the specificities were 93.3% and 97.8%, respectively. In a test set including 13,222 ECGs, ECG12Net had a similar performance in terms of sensitivity for severe hypokalemia (95.6%) and severe hyperkalemia (84.5%), with a mean absolute error of 0.531. The specificities for detecting hypokalemia and hyperkalemia were 81.6% and 96.0%, respectively. Conclusions: A deep-learning model based on a 12-lead ECG may help physicians promptly recognize severe dyskalemias and thereby potentially reduce cardiac events.


  • Open Access

    A multimodal high-value curriculum affects drivers of utilization and performance on the high-value care component of the internal medicine in-training exam

    by Tom Chau, Laura Loertscher

    Background: Teaching the practice of high-value care (HVC) is an increasingly important function of graduate medical education but best practices and long-term outcomes remain unknown. Objective: Whether a multimodal curriculum designed to address specific drivers of low-value care would affect resident attitudes, skills, and performance of HVC as tested by the Internal Medicine In-Training Exam (ITE). Methods: In 2012, we performed a baseline needs assessment among internal medicine residents at a community program regarding drivers of healthcare utilization. We then created a multimodal curriculum with online interactive worksheets, lectures, and faculty buy-in to target specific skills, knowledge, and culture deficiencies. Perceived drivers of care and performance on the Internal Medicine ITE were assessed yearly through 2016. Results: Fourteen of 27 (52%) residents completed the initial needs assessment while the curriculum was eventually seen by at least 24 of 27 (89%). The ITE was taken by every resident every year. Long-term, 3-year follow-up demonstrated persistent improvement in many drivers of utilization (patient requests, reliance on subspecialists, defensive medicine, and academic curiosity) and improvement with sustained high performance on the high-value component of the ITE. Conclusion: A multimodal curriculum targeting specific drivers of low-value care can change culture and lead to sustained improvement in the practice of HVC.