Claudio Reverberi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Claudio Reverberi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Nicola Gaibazzi
Cardiology Department, Parma University Hospital, 43126 Parma, Italy
3 shared publications - Alessandro Medoro
Department of Medicine and Health Sciences “V. Tiberio”, University of Molise, Campobasso, Italy
1 shared publication Andrea Botti
University Hospital Maggiore, Cardiology Unit, Viale Gramsci 14, 43126 Parma, Italy
1 shared publication- Antonella Vezzani
Department of Surgery, University Hospital of Parma, 43100 Parma, Italy
1 shared publication - Bernardo Di Maria
Independent Researcher, 43126 Parma, Italy
1 shared publication - Chiara Martini
Diagnostic Department, University Hospital of Parma, Via Gramsci 14, 43126 Parma, Italy
1 shared publication
Latest Publications
- Open Access
- 15 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 712
Commercially Available Heart Rate Monitor Repurposed for Automatic Arrhythmia Detection with Snapshot Electrocardiographic Capability: A Pilot Validation
The usefulness of opportunistic arrhythmia screening strategies, using an electrocardiogram (ECG) or other methods for random “snapshot” assessments is limited by the unexpected and occasional nature of arrhythmias, leading to a high rate of missed diagnosis. We have previously validated a cardiac monitoring system for AF detection pairing simple consumer-grade Bluetooth low-energy (BLE) heart rate (HR) sensors with a smartphone application (RITMIA™, Heart Sentinel srl, Italy). In the current study, we test a significant upgrade to the above-mentioned system, thanks to the technical capability of new HR sensors to run algorithms on the sensor itself and to acquire, and store on-board, single-lead ECG strips. We have reprogrammed an HR monitor intended for sports use (Movensense HR+) to run our proprietary RITMIA algorithm code in real-time, based on RR analysis, so that if any type of arrhythmia is detected, it triggers a brief retrospective recording of a single-lead ECG, providing tracings of the specific arrhythmia for later consultation. We report the initial data on the behavior, feasibility, and high diagnostic accuracy of this ultra-low weight customized device for standalone automatic arrhythmia detection and ECG recording, when several types of arrhythmias were simulated under different baseline conditions. Conclusions: The customized device was capable of detecting all types of simulated arrhythmias and correctly triggered a visually interpretable ECG tracing. Future human studies are needed to address real-life accuracy of this device.
- 15 March 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 712
Open AccessCommercially Available Heart Rate Monitor Repurposed for Automatic Arrhythmia Detection with Snapshot Electrocardiographic Capability: A Pilot Validation
The usefulness of opportunistic arrhythmia screening strategies, using an electrocardiogram (ECG) or other methods for random “snapshot” assessments is limited by the unexpected and occasional nature of arrhythmias, leading to a high rate of missed diagnosis. We have previously validated a cardiac monitoring system for AF detection pairing simple consumer-grade Bluetooth low-energy (BLE) heart rate (HR) sensors with a smartphone application (RITMIA™, Heart Sentinel srl, Italy). In the current study, we test a significant upgrade to the above-mentioned system, thanks to the technical capability of new HR sensors to run algorithms on the sensor itself and to acquire, and store on-board, single-lead ECG strips. We have reprogrammed an HR monitor intended for sports use (Movensense HR+) to run our proprietary RITMIA algorithm code in real-time, based on RR analysis, so that if any type of arrhythmia is detected, it triggers a brief retrospective recording of a single-lead ECG, providing tracings of the specific arrhythmia for later consultation. We report the initial data on the behavior, feasibility, and high diagnostic accuracy of this ultra-low weight customized device for standalone automatic arrhythmia detection and ECG recording, when several types of arrhythmias were simulated under different baseline conditions. Conclusions: The customized device was capable of detecting all types of simulated arrhythmias and correctly triggered a visually interpretable ECG tracing. Future human studies are needed to address real-life accuracy of this device.
- Open Access
- 7 July 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1229
Sudden Cardiac Death Caused by a Fatal Association of Hypertrophic Cardiomyopathy (MYH7, p.Arg719Trp), Heterozygous Familial Hypercholesterolemia (LDLR, p.Gly343Lys) and SARS-CoV-2 B.1.1.7 Infection
Hypertrophic cardiomyopathy (HCM) and heterozygous familial hypercholesterolemia (HeFH), two of the most common genetic cardiovascular disorders, can lead to sudden cardiac death. These conditions could be complicated by concomitant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection as in the case herein described. A young amateur soccer player died in late October 2020 after a fatal arrhythmia and the autopsy revealed the presence of HCM with diffuse non-obstructive coronary disease. The molecular autopsy revealed a compound condition with a first mutation in the MYH7 gene (p.Arg719Trp) and a second mutation in the LDLR gene (p.Gly343Cys): both have already been described as associated with HCM and HeFH, respectively. In addition, molecular analyses showed the presence of SARS-CoV-2 lineage B.1.1.7 (UK variant with high titer in the myocardium. Co-segregation analysis within the family (n = 19) showed that heterozygous LDLR mutation was maternally inherited, while the heterozygous MYH7 genetic lesion was de novo. All family member carriers of the LDLR mutation (n = 13) had systematic higher LDL plasma concentrations and positive records of cardiac and vascular ischemic events at young age. Considering that HCM mutations are in themselves involved in the predisposition to malignant arrhythmogenicity and HeFH could cause higher risk of cardiac complications in SARS-CoV-2 infection, this case could represent an example of a potential SARS-CoV-2 infection role in triggering or unmasking inherited cardiovascular disease, whose combination might represent the cause of fatal arrhythmia at such a young age. Additionally, it can provide clues in dating the presence of the SARS-CoV-2 lineage B.1.1.7 in Northern Italy in the early phases of the second pandemic wave.
- 7 July 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (7) , 1229
Open AccessSudden Cardiac Death Caused by a Fatal Association of Hypertrophic Cardiomyopathy (MYH7, p.Arg719Trp), Heterozygous Familial Hypercholesterolemia (LDLR, p.Gly343Lys) and SARS-CoV-2 B.1.1.7 Infection
Hypertrophic cardiomyopathy (HCM) and heterozygous familial hypercholesterolemia (HeFH), two of the most common genetic cardiovascular disorders, can lead to sudden cardiac death. These conditions could be complicated by concomitant severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection as in the case herein described. A young amateur soccer player died in late October 2020 after a fatal arrhythmia and the autopsy revealed the presence of HCM with diffuse non-obstructive coronary disease. The molecular autopsy revealed a compound condition with a first mutation in the MYH7 gene (p.Arg719Trp) and a second mutation in the LDLR gene (p.Gly343Cys): both have already been described as associated with HCM and HeFH, respectively. In addition, molecular analyses showed the presence of SARS-CoV-2 lineage B.1.1.7 (UK variant with high titer in the myocardium. Co-segregation analysis within the family (n = 19) showed that heterozygous LDLR mutation was maternally inherited, while the heterozygous MYH7 genetic lesion was de novo. All family member carriers of the LDLR mutation (n = 13) had systematic higher LDL plasma concentrations and positive records of cardiac and vascular ischemic events at young age. Considering that HCM mutations are in themselves involved in the predisposition to malignant arrhythmogenicity and HeFH could cause higher risk of cardiac complications in SARS-CoV-2 infection, this case could represent an example of a potential SARS-CoV-2 infection role in triggering or unmasking inherited cardiovascular disease, whose combination might represent the cause of fatal arrhythmia at such a young age. Additionally, it can provide clues in dating the presence of the SARS-CoV-2 lineage B.1.1.7 in Northern Italy in the early phases of the second pandemic wave.
- Open Access
- 2 July 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-6
The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
Background. The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. Objective. The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). Design. In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. Results. A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. Conclusions. The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability.
- 2 July 2019
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-6
Open AccessThe RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
Background. The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. Objective. The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). Design. In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. Results. A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. Conclusions. The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability.
- 1 September 2016
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 29 (9) , 899-906
Effect of Pharmacologic Stress Test Results on Outcomes in Obese versus Nonobese Subjects Referred for Stress Perfusion Echocardiography
- 1 September 2016
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 29 (9) , 899-906
Effect of Pharmacologic Stress Test Results on Outcomes in Obese versus Nonobese Subjects Referred for Stress Perfusion Echocardiography