JKJan Knappe

Jan Knappe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan Knappe has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lower grass stomatal conductance under elevated CO2 can decrease transpiration and evapotranspiration rates despite carbon fertilization

    by Sate Ahmad, Charilaos Yiotis, Weimu Xu, Jan Knappe, Laurence Gill, Jennifer McElwain

    Anthropogenic increase in carbon dioxide (CO2) affects plant physiology. Plant responses to elevated CO2 typically include: (1) enhanced photosynthesis and increased primary productivity due to carbon fertilization and (2) suppression of leaf transpiration due to CO2‐driven decrease in stomatal conductance. The combined effect of these responses on the total plant transpiration and on evapotranspiration (ET) has a wide range of implications on local, regional, and global hydrological cycles, and thus needs to be better understood. Here, we investigated the net effect of CO2‐driven perennial ryegrass (Lolium perenne) physiological responses on transpiration and evapotranspiration by integrating physiological and hydrological (water budget) methods, under a controlled environment. Measurements of the net photosynthetic rate, stomatal conductance, transpiration rate, leaf mass per area, aboveground biomass, and water balance components were recorded. Measured variables under elevated CO2 were compared with those of ambient CO2. As expected, our results show that elevated CO2 significantly decreases whole‐plant transpiration rates (38% lower in the final week) which is a result of lower stomatal conductance (57% lower in the final week) despite a slight increase in aboveground biomass. Additionally, there was an overall decline in evapotranspiration (ET) under elevated CO2, indicating the impact of CO2‐mediated suppression of transpiration on the overall water balance. Although studies with larger sample sizes are needed for more robust conclusions, our findings have significant implications for global environmental change. Reductions in ET from ryegrass‐dominated grasslands and pastures could increase soil moisture and groundwater recharge, potentially leading to increased surface runoff and flooding.


  • Open Access

    Successful characterisation of on-site wastewater treatment system biomats using the Microbes of Activated Sludge and Anaerobic Digesters (MiDAS) taxonomic database

    by Alejandro Javier Criado Monleon, Jan Knappe, Celia Somlai, Carolina Ospina Betancourth, Muhammad Ali, Thomas P. Curtis, Laurence William Gill

    There has been a large output of genomic data in ecological studies of centralised wastewater treatment plants over the past number of years. One significant collaboration of Danish and Swedish research institutions lead to the development of the Microbes of Activated Sludge and Anaerobic Digesters (MiDAS 4) global taxonomic database. The database has been an effective tool in understanding centralised systems, however, there has been no known application of this tool in understanding the ecology of organisms in the on-site wastewater treatment systems. The growth of microbial mats or "biomats" has been identified as an essential component in the attenuation of pollutants within the soil treatment unit (STU) of conventional on-site wastewater treatment systems (OWTSs). Two research sites were employed to determine the influence of the pre-treatment of raw-domestic wastewater on these communities. The STUs at each of the two sites were split, whereby half received effluent directly from septic tanks, and half received more highly treated effluents from packaged aerobic treatment systems [a coconut husk media filter on one site, and a rotating biodisc contactor (RBC) on the other site]. Effluents from the RBC had a higher level of pre-treatment [~90% Total Organic Carbon (TOC) removal], compared to the media filter (~60% TOC removal). These sites' biomat were sampled two-dimensionally in respect of distance and depth, to configure ecological data with changes in the volumetric water content values which had been used successfully as an indicator of the location of the biomat. A total of 92 samples were obtained from both STU locations and characterized by MiDAS taxonomic database. Our study has shown that the biomats receiving primary or untreated effluent have less pronounced increases in denitrifiers compared to the biomats receiving treated or partially treated effluent. but biomats receiving primary effluents have been found to be capable of removing six times the amount of total nitrogen. This suggests that the increases in functional richness within the STU are secondary to bioclogging, as metabolic rates could be limited by hydraulic conductivity.

  • Open Access

    Assessing the spatial and temporal variability of greenhouse gas emissions from different configurations of on-site wastewater treatment system using discrete and continuous gas flux measurement

    by Jan Knappe, Celia Somlai, Laurence W. Gill

    Global emissions linked to wastewater treatment are estimated to account for up to 1.5 % of total greenhouse gas (GHG) emissions globally. However, few studies have measured GHG emissions from domestic on-site treatment systems (DWWTSs) directly. In this study, two DWWTSs were monitored for 446 d and > 42 000 gas flux measurements were conducted using both discrete spot measurements and continuous flux chamber deployments. The observed GHG fluxes from biological activity in the soil and water phase were found to be highly spatially and temporally variable and correlated to environmental factors, water usage patterns and system design. In total, the results show that a septic tank discharging effluent into a well-designed soil treatment unit is estimated to emit a net 9.99 kg-CO2eq.cap-1yr-1 , with approximately 63 %, 27 % and 10 % of the total CO2-equivalent net emissions in the form of CO2, CH4 and N2O, respectively. Emissions from the septic tank surface contributed over 50 % of total emissions and tended to be strongly underestimated by one-off discrete measurements, especially when episodic ebullitive events are to be considered. Fluxes from the soil treatment unit (STU) stemmed from both the soil surface and the vent system. Soil fluxes were mostly influenced by temperature but peaked regularly under conditions of rapidly changing soil water content. Vent fluxes were mostly governed by effluent, quality and a low number of high-emission events were responsible for the majority of total observed vent emissions. Owing to the strong overall spatial and temporal heterogeneity of observed fluxes from DWWTSs across all modules, future studies should focus on continuous deployments of a number of flux chambers over discrete measurements to accurately assess GHG emissions from on-site systems. This study also provided insights into managing GHG emissions from DWWTSs by different system configuration design, as well as indicating that the current IPCC emission factors for CH4 and N2O significantly overestimate emissions for on-site wastewater treatment systems.


  • Open Access

    Comment on bg-2021-198

    by Jan Knappe, Celia Somlai, Laurence Gill

    Global emissions linked to wastewater treatment are estimated to account for up to 1.5 % of total greenhouse gas (GHG) emissions globally. However, few studies have measured GHG emissions from domestic on-site treatment systems (DWWTSs) directly. In this study, two DWWTSs were monitored for 446 days and > 42,000 gas flux measurements were conducted using both discrete spot measurements and continuous flux chamber deployments. The observed GHG fluxes from biological activity in the soil and water phase were found to be highly spatially and temporally variable and correlated to environmental factors, water usage patterns and system design. In total, the results show that a septic tank discharging effluent into a well-designed soil treatment unit is estimated to emit a net 9.99 kg-CO2eq cap−1 yr−1, with approximately 63 %, 27 % and 10 % of the total CO2-equivalent net emissions in the form of CO2, CH4 and N2O, respectively. Emissions from the septic tank surface contributed over 50 % of total emissions and tended to be strongly underestimated by one-off discrete measurements, especially when episodic ebullitive events are to be considered. Fluxes from the soil treatment unit (STU) stemmed from both the soil surface and the vent system, but were also found to be periodically negative, i.e. net uptakes. Soil fluxes were mostly influenced by temperature but peaked regularly under conditions of rapidly changing soil water content. Vent fluxes were mostly governed by effluent quality and a low number of high emission events was responsible for the majority of total observed vent emissions. Owing to the strong overall spatial and temporal heterogeneity of observed fluxes from DWWTSs across all modules, future studies should focus on continuous deployments of a number of flux chambers over discrete measurements to accurately assess GHG emissions from on-site systems. This study also provided insights into managing GHG emissions from DWWTSs by different system configuration design, as well as indicating that the current IPCC emission factors for CH4 and N2O are significantly overestimating emissions for on-site wastewater treatment systems.

  • Open Access

    Comment on bg-2021-198

    by Jan Knappe, Celia Somlai, Laurence Gill

    Global emissions linked to wastewater treatment are estimated to account for up to 1.5 % of total greenhouse gas (GHG) emissions globally. However, few studies have measured GHG emissions from domestic on-site treatment systems (DWWTSs) directly. In this study, two DWWTSs were monitored for 446 days and > 42,000 gas flux measurements were conducted using both discrete spot measurements and continuous flux chamber deployments. The observed GHG fluxes from biological activity in the soil and water phase were found to be highly spatially and temporally variable and correlated to environmental factors, water usage patterns and system design. In total, the results show that a septic tank discharging effluent into a well-designed soil treatment unit is estimated to emit a net 9.99 kg-CO2eq cap−1 yr−1, with approximately 63 %, 27 % and 10 % of the total CO2-equivalent net emissions in the form of CO2, CH4 and N2O, respectively. Emissions from the septic tank surface contributed over 50 % of total emissions and tended to be strongly underestimated by one-off discrete measurements, especially when episodic ebullitive events are to be considered. Fluxes from the soil treatment unit (STU) stemmed from both the soil surface and the vent system, but were also found to be periodically negative, i.e. net uptakes. Soil fluxes were mostly influenced by temperature but peaked regularly under conditions of rapidly changing soil water content. Vent fluxes were mostly governed by effluent quality and a low number of high emission events was responsible for the majority of total observed vent emissions. Owing to the strong overall spatial and temporal heterogeneity of observed fluxes from DWWTSs across all modules, future studies should focus on continuous deployments of a number of flux chambers over discrete measurements to accurately assess GHG emissions from on-site systems. This study also provided insights into managing GHG emissions from DWWTSs by different system configuration design, as well as indicating that the current IPCC emission factors for CH4 and N2O are significantly overestimating emissions for on-site wastewater treatment systems.

  • Open Access

    Characterisation of Organic Matter and Its Transformation Processes in On-Site Wastewater Effluent Percolating through Soil Using Fluorescence Spectroscopic Methods and Parallel Factor Analysis (PARAFAC)

    by Donata Dubber, Jan Knappe, Laurence W. Gill

    This research has used fluorescence spectroscopy and parallel factor analysis (PARAFAC) in order to characterize dissolved organic matter in septic tank effluent, as it passes through the biomat/biozone, infiltrating into the unsaturated zone beneath domestic wastewater treatment systems (DWWTSs). Septic tank effluent and soil moisture samples from the percolation areas of two DWWTSs have been analyzed using fluorescence excitation–emission spectroscopy. Using PARAFAC analysis, a six-component model was obtained whereby individual model components could be assigned to humified organic matter, fluorescent whitening compounds (FWCs), and protein-like compounds. This has shown that fluorescent dissolved organic matter (FDOM) in domestic wastewater was dominated by protein-like compounds and FWCs and that, with treatment in the percolation area, protein-like compounds and FWCs are removed and contributions from terrestrially derived (soil) organic decomposition compounds increase, leading to a higher degree of humification and aromaticity. The results also suggest that the biomat is the most important element determining FDOM removal and consequently affecting DOM composition. Furthermore, no significant difference was found in the FDOM composition of samples from the percolation area irrespective of whether they received primary or secondary effluent. Overall, the tested fluorometric methods were shown to provide information about structural and functional properties of organic matter which can be useful for further studies concerning bacterial and/or virus transport from DWWTSs.


  • Open Access

    Assessing the spatial and temporal variability of GHG emissions from different configurations of on-site wastewater treatment system using discrete and continuous gas flux measurement

    by Jan Knappe, Celia Somlai, Laurence Gill

    Global emissions linked to wastewater treatment are estimated to account for up to 1.5 % of total greenhouse gas (GHG) emissions globally. However, few studies have measured GHG emissions from domestic on-site treatment systems (DWWTSs) directly. In this study, two DWWTSs were monitored for 446 days and > 42,000 gas flux measurements were conducted using both discrete spot measurements and continuous flux chamber deployments. The observed GHG fluxes from biological activity in the soil and water phase were found to be highly spatially and temporally variable and correlated to environmental factors, water usage patterns and system design. In total, the results show that a septic tank discharging effluent into a well-designed soil treatment unit is estimated to emit a net 9.99 kg-CO2eq cap−1 yr−1, with approximately 63 %, 27 % and 10 % of the total CO2-equivalent net emissions in the form of CO2, CH4 and N2O, respectively. Emissions from the septic tank surface contributed over 50 % of total emissions and tended to be strongly underestimated by one-off discrete measurements, especially when episodic ebullitive events are to be considered. Fluxes from the soil treatment unit (STU) stemmed from both the soil surface and the vent system, but were also found to be periodically negative, i.e. net uptakes. Soil fluxes were mostly influenced by temperature but peaked regularly under conditions of rapidly changing soil water content. Vent fluxes were mostly governed by effluent quality and a low number of high emission events was responsible for the majority of total observed vent emissions. Owing to the strong overall spatial and temporal heterogeneity of observed fluxes from DWWTSs across all modules, future studies should focus on continuous deployments of a number of flux chambers over discrete measurements to accurately assess GHG emissions from on-site systems. This study also provided insights into managing GHG emissions from DWWTSs by different system configuration design, as well as indicating that the current IPCC emission factors for CH4 and N2O are significantly overestimating emissions for on-site wastewater treatment systems.