ANAmrendra Narayan
Amrendra Narayan
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Amrendra Narayan has a total of 636 co-authors. Here are the top co-authors by number of shared publications:
B. Sawatzky
Thomas Jefferson National Accelerator Facility
22 shared publicationsF. Benmokhtar
Christopher Newport University
22 shared publicationsD. Gaskell
21 shared publicationsR. Subedi
George Washington University
20 shared publications- Wouter Deconinck
DESY, Hamburg, Germany
20 shared publications F. Garibaldi
19 shared publications
Latest Publications
- Open Access
- 1 March 2017
- Published by Elsevier in Physics Letters B
- Vol. 766, 339-344
A novel comparison of Møller and Compton electron-beam polarimeters
- 1 March 2017
- Published by Elsevier in Physics Letters B
- Vol. 766, 339-344
Open AccessA novel comparison of Møller and Compton electron-beam polarimeters
- 25 November 2016
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters A
- Vol. 31 (38)
A test of local Lorentz invariance with Compton scattering asymmetry
- 25 November 2016
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters A
- Vol. 31 (38)
A test of local Lorentz invariance with Compton scattering asymmetry
- 21 November 2016
- Published by Springer Nature in Hyperfine Interactions
- Vol. 237 (1) , 161
The tracking analysis in the Q-weak experiment
- 21 November 2016
- Published by Springer Nature in Hyperfine Interactions
- Vol. 237 (1) , 161
The tracking analysis in the Q-weak experiment
- Open Access
- 6 September 2016
- Published by American Physical Society (APS) in Physical Review D
- Vol. 94 (5) , 052003
Measurements ofand: Probing the neutron spin structureWe report on the results of the E06-014 experiment performed at Jefferson Lab in Hall A, where a precision measurement of the twist-3 matrix element of the neutron () was conducted. The quantity represents the average color Lorentz force a struck quark experiences in a deep inelastic electron scattering event off a neutron due to its interaction with the hadronizing remnants. This color force was determined from a linear combination of the third moments of the spin structure functions, and , after nuclear corrections had been applied to these moments. The structure functions were obtained from a measurement of the unpolarized cross section and of double-spin asymmetries in the scattering of a longitudinally polarized electron beam from a transversely and a longitudinally polarized target. The measurement kinematics included two average bins of and , and Bjorken- covering the deep inelastic and resonance regions. We have found that is small and negative for , and even smaller for , consistent with the results of a lattice QCD calculation. The twist-4 matrix element was extracted by combining our measured with the world data on the first moment in of , . We found to be roughly an order of magnitude larger than . Utilizing the extracted and data, we separated the Lorentz color force into its electric and magnetic components, and , and found them to be equal and opposite in magnitude, in agreement with the predictions from an instanton model but not with those from QCD sum rules. Furthermore, using the measured double-spin asymmetries, we have extracted the virtual photon-nucleon asymmetry on the neutron , the structure function ratio , and the quark ratios and . These results were found to be consistent with deep-inelastic scattering world data and with the prediction of the constituent quark model but at odds with the perturbative quantum chromodynamics predictions at large .- 6 September 2016
- Published by American Physical Society (APS) in Physical Review D
- Vol. 94 (5) , 052003
Open AccessMeasurements ofand: Probing the neutron spin structureWe report on the results of the E06-014 experiment performed at Jefferson Lab in Hall A, where a precision measurement of the twist-3 matrix element of the neutron () was conducted. The quantity represents the average color Lorentz force a struck quark experiences in a deep inelastic electron scattering event off a neutron due to its interaction with the hadronizing remnants. This color force was determined from a linear combination of the third moments of the spin structure functions, and , after nuclear corrections had been applied to these moments. The structure functions were obtained from a measurement of the unpolarized cross section and of double-spin asymmetries in the scattering of a longitudinally polarized electron beam from a transversely and a longitudinally polarized target. The measurement kinematics included two average bins of and , and Bjorken- covering the deep inelastic and resonance regions. We have found that is small and negative for , and even smaller for , consistent with the results of a lattice QCD calculation. The twist-4 matrix element was extracted by combining our measured with the world data on the first moment in of , . We found to be roughly an order of magnitude larger than . Utilizing the extracted and data, we separated the Lorentz color force into its electric and magnetic components, and , and found them to be equal and opposite in magnitude, in agreement with the predictions from an instanton model but not with those from QCD sum rules. Furthermore, using the measured double-spin asymmetries, we have extracted the virtual photon-nucleon asymmetry on the neutron , the structure function ratio , and the quark ratios and . These results were found to be consistent with deep-inelastic scattering world data and with the prediction of the constituent quark model but at odds with the perturbative quantum chromodynamics predictions at large . - Open Access
- 12 August 2016
- Published by American Physical Society (APS) in Physical Review C
- Vol. 94 (2) , 021302
Spectroscopy of the neutron-rich hypernucleusfrom electron scatteringThe missing mass spectroscopy of the hypernucleus was performed using the reaction at the Thomas Jefferson National Accelerator Facility Hall C. The -binding energy of the ground-state () was determined with a smaller error than that of the previous measurement, being . The experiment also provided new insight into charge symmetry breaking in -shell hypernuclear systems. Finally, a peak at was observed and assigned as a mixture of and states, confirming the “gluelike” behavior of , which makes an unstable state in stable against neutron emission.- 12 August 2016
- Published by American Physical Society (APS) in Physical Review C
- Vol. 94 (2) , 021302
Open AccessSpectroscopy of the neutron-rich hypernucleusfrom electron scatteringThe missing mass spectroscopy of the hypernucleus was performed using the reaction at the Thomas Jefferson National Accelerator Facility Hall C. The -binding energy of the ground-state () was determined with a smaller error than that of the previous measurement, being . The experiment also provided new insight into charge symmetry breaking in -shell hypernuclear systems. Finally, a peak at was observed and assigned as a mixture of and states, confirming the “gluelike” behavior of , which makes an unstable state in stable against neutron emission. - Open Access
- 10 March 2016
- Published by American Physical Society (APS) in Physical Review C
- Vol. 93 (3) , 034314
High resolution spectroscopic study ofSpectroscopy of a hypernucleus was carried out at JLab Hall C using the reaction. A new magnetic spectrometer system (SPL+HES+HKS), specifically designed for high resolution hypernuclear spectroscopy, was used to obtain an energy spectrum with a resolution of MeV (FWHM). The well-calibrated spectrometer system of the present experiment using reactions allowed us to determine the energy levels; and the binding energy of the ground-state peak (mixture of and states) was found to be MeV. The result indicates that the ground-state energy is shallower than that of an emulsion study by about 0.5 MeV which provides valuable experimental information on the charge symmetry breaking effect in the interaction.- 10 March 2016
- Published by American Physical Society (APS) in Physical Review C
- Vol. 93 (3) , 034314
Open AccessHigh resolution spectroscopic study ofSpectroscopy of a hypernucleus was carried out at JLab Hall C using the reaction. A new magnetic spectrometer system (SPL+HES+HKS), specifically designed for high resolution hypernuclear spectroscopy, was used to obtain an energy spectrum with a resolution of MeV (FWHM). The well-calibrated spectrometer system of the present experiment using reactions allowed us to determine the energy levels; and the binding energy of the ground-state peak (mixture of and states) was found to be MeV. The result indicates that the ground-state energy is shallower than that of an emulsion study by about 0.5 MeV which provides valuable experimental information on the charge symmetry breaking effect in the interaction. - Open Access
- 16 February 2016
- Published by American Physical Society (APS) in Physical Review X
- Vol. 6 (1) , 011013
Precision Electron-Beam Polarimetry at 1 GeV Using Diamond Microstrip Detectors
We report on the highest precision yet achieved in the measurement of the polarization of a low-energy, , continuous-wave (CW) electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond microstrip detector that was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector, and its large acceptance. The polarization of the , 1.16-GeV electron beam was measured with a statistical precision of per hour and a systematic uncertainty of 0.59%. This exceeds the level of precision required by the experiment, a measurement of the weak vector charge of the proton. Proposed future low-energy experiments require polarization uncertainty , and this result represents an important demonstration of that possibility. This measurement is the first use of diamond detectors for particle tracking in an experiment. It demonstrates the stable operation of a diamond-based tracking detector in a high radiation environment, for two years.- 16 February 2016
- Published by American Physical Society (APS) in Physical Review X
- Vol. 6 (1) , 011013
Open AccessPrecision Electron-Beam Polarimetry at 1 GeV Using Diamond Microstrip Detectors
We report on the highest precision yet achieved in the measurement of the polarization of a low-energy, , continuous-wave (CW) electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond microstrip detector that was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector, and its large acceptance. The polarization of the , 1.16-GeV electron beam was measured with a statistical precision of per hour and a systematic uncertainty of 0.59%. This exceeds the level of precision required by the experiment, a measurement of the weak vector charge of the proton. Proposed future low-energy experiments require polarization uncertainty , and this result represents an important demonstration of that possibility. This measurement is the first use of diamond detectors for particle tracking in an experiment. It demonstrates the stable operation of a diamond-based tracking detector in a high radiation environment, for two years. - Open Access
- 14 July 2015
- Published by American Physical Society (APS) in Physical Review C
- Vol. 92 (1) , 015207
Double spin asymmetries of inclusive hadron electroproduction from a transversely polarizedtargetWe report the measurement of beam-target double spin asymmetries in the inclusive production of identified hadrons, + , using a longitudinally polarized 5.9-GeV electron beam and a transversely polarized target. Hadrons , and proton) were detected at with an average momentum GeV/c and a transverse momentum coverage from 0.60 to 0.68 GeV/c. Asymmetries from the target were observed to be nonzero for production when the target was polarized transversely in the horizontal plane. The and asymmetries have opposite signs, analogous to the behavior of in semi-inclusive deep-inelastic scattering.- 14 July 2015
- Published by American Physical Society (APS) in Physical Review C
- Vol. 92 (1) , 015207
Open AccessDouble spin asymmetries of inclusive hadron electroproduction from a transversely polarizedtargetWe report the measurement of beam-target double spin asymmetries in the inclusive production of identified hadrons, + , using a longitudinally polarized 5.9-GeV electron beam and a transversely polarized target. Hadrons , and proton) were detected at with an average momentum GeV/c and a transverse momentum coverage from 0.60 to 0.68 GeV/c. Asymmetries from the target were observed to be nonzero for production when the target was polarized transversely in the horizontal plane. The and asymmetries have opposite signs, analogous to the behavior of in semi-inclusive deep-inelastic scattering. - Open Access
- 1 May 2015
- Published by Elsevier in Physics Letters B
- Vol. 744, 309-314
Precision measurements of in the deep inelastic regime- 1 May 2015
- Published by Elsevier in Physics Letters B
- Vol. 744, 309-314
Open AccessPrecision measurements of in the deep inelastic regime - 1 May 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 781, 105-133
The Qweak experimental apparatus
- 1 May 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 781, 105-133
The Qweak experimental apparatus