Vikash Sinha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Vikash Sinha has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Sharifuddin Mondal
Department of Mechanical Engineering, National Institute of Technology, Patna, India
3 shared publications- Sharifuddin Mondal
Department of Mechanical Engineering, National Institute of Technology Patna, Patna, India
3 shared publications Ashish Shastri
1 shared publicationPankaj Bhokare
1 shared publicationRupesh Patil
1 shared publication
Latest Publications
- 6 April 2023
- Published by Taylor & Francis
- p. 1081-1087
Component fault detection and isolation for PEMFC systems using unknown input observers
An unknown input observer (UIO) based component fault detection and isolation (CFDI) technique for proton exchange membrane fuel cell system (PEMFCS) is presented. The algorithm is derived by assuming single component fault at any time instant and devised with the assumption that sensors and actuators are fault free. First, a number of UIOs are designed for PEMFCS in such a way that one particular observer will be sensitive to a particular component and residuals are determined. Then, a residual based CFDI algorithm is formulated which is not incorporated in previous works on fault diagnosis of such systems. The effectiveness of the algorithm is shown with simulation results of the cathode pressure model of PEMFCS. The results show novel UIO based component fault diagnosis of the system using decision table.
- 6 April 2023
- Published by Taylor & Francis
- p. 1081-1087
Component fault detection and isolation for PEMFC systems using unknown input observers
An unknown input observer (UIO) based component fault detection and isolation (CFDI) technique for proton exchange membrane fuel cell system (PEMFCS) is presented. The algorithm is derived by assuming single component fault at any time instant and devised with the assumption that sensors and actuators are fault free. First, a number of UIOs are designed for PEMFCS in such a way that one particular observer will be sensitive to a particular component and residuals are determined. Then, a residual based CFDI algorithm is formulated which is not incorporated in previous works on fault diagnosis of such systems. The effectiveness of the algorithm is shown with simulation results of the cathode pressure model of PEMFCS. The results show novel UIO based component fault diagnosis of the system using decision table.
- 15 March 2022
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (4) , 1305-1314
Robust Adaptive Fault Estimation Observer-Based FTC Design for Time-Delay PEMFC Systems
- 15 March 2022
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 103 (4) , 1305-1314
Robust Adaptive Fault Estimation Observer-Based FTC Design for Time-Delay PEMFC Systems
- 22 April 2021
- Published by Springer Nature
- p. 263-270
Robust Adaptive Observer Based Fault Tolerant Controller Design for Proton Exchange Membrane Fuel Cell Systems
- 22 April 2021
- Published by Springer Nature
- p. 263-270
Robust Adaptive Observer Based Fault Tolerant Controller Design for Proton Exchange Membrane Fuel Cell Systems
- 5 February 2021
- Published by Springer Nature
- p. 465-473
Adaptive Unknown Input Observer for Actuator Fault Detection and Isolation of PEM Fuel Cell Systems
- 5 February 2021
- Published by Springer Nature
- p. 465-473
Adaptive Unknown Input Observer for Actuator Fault Detection and Isolation of PEM Fuel Cell Systems
- 18 October 2020
- Published by Springer Nature
- p. 673-683
Actuator Fault Detection and Isolation for PEM Fuel Cell Systems Using Unknown Input Observers
- 18 October 2020
- Published by Springer Nature
- p. 673-683
Actuator Fault Detection and Isolation for PEM Fuel Cell Systems Using Unknown Input Observers
- 10 February 2020
- Published by Taylor & Francis in Journal of Control and Decision
- Vol. 8 (2) , 222-232
Adaptive unknown input observer approach for multi-fault diagnosis of PEM fuel cell system with time-delays
An adaptive unknown input observer (AUIO) for polymer electrolyte membrane fuel cell system with time-delays is developed and applied to formulate a fault diagnosis algorithm for multiple actuator fault detection and isolation (MAFDI). In a scheme based on multiple-model, a group of observers are developed based on a model that describes the system in the presence of a specific actuator fault. The observers are used to generate fault-dependant residual signals. When a model matches the system, the residual signal is zero and becomes non-zero in case of a faulty scenario. Two types of actuator faults are considered namely stuck fault, where the inputs delivered by the faulty actuators are blocked to constant value, and loss of effectiveness fault. The effectiveness of the proposed AUIO and MAFDI algorithm is shown with simulation results.
- 10 February 2020
- Published by Taylor & Francis in Journal of Control and Decision
- Vol. 8 (2) , 222-232
Adaptive unknown input observer approach for multi-fault diagnosis of PEM fuel cell system with time-delays
An adaptive unknown input observer (AUIO) for polymer electrolyte membrane fuel cell system with time-delays is developed and applied to formulate a fault diagnosis algorithm for multiple actuator fault detection and isolation (MAFDI). In a scheme based on multiple-model, a group of observers are developed based on a model that describes the system in the presence of a specific actuator fault. The observers are used to generate fault-dependant residual signals. When a model matches the system, the residual signal is zero and becomes non-zero in case of a faulty scenario. Two types of actuator faults are considered namely stuck fault, where the inputs delivered by the faulty actuators are blocked to constant value, and loss of effectiveness fault. The effectiveness of the proposed AUIO and MAFDI algorithm is shown with simulation results.
- 3 May 2017
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 6 (2) , 511-528
Recent development on performance modelling and fault diagnosis of fuel cell systems
- 3 May 2017
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 6 (2) , 511-528
Recent development on performance modelling and fault diagnosis of fuel cell systems