Telia Curtis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Telia Curtis has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Darshan Choudhary
Photovoltaic Reliability Laboratory, Arizona State University, Mesa, AZ 85212 USA
1 shared publication GovindaSamy TamizhMani
Arizona State University Photovoltaic Reliability Laboratory (ASU-PRL), Mesa, AZ, 85212, USA
1 shared publication- Govindasamy Tamizhmani
Photovoltaic Reliability Laboratory, Arizona State University, Mesa, AZ 85212, USA
1 shared publication - Lin J. Simpson
National Renewable Energy Laboratory, Golden, CO 80401 USA
1 shared publication - Matthew Muller
National Laboratory of the Rockies (NLR), Golden, CO (United States)
1 shared publication - Praveen Ravi
Photovoltaic Reliability Laboratory, Arizona State University, Mesa, AZ 85212 USA
1 shared publication
Latest Publications
- 2 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 9 (1) , 227-232
Indoor Soil Deposition Chamber: Evaluating Effectiveness of Antisoiling Coatings
An indoor soil deposition method has been developed to simulate natural soil deposition on glass coupons or one-cell and multicell photovoltaic (PV) modules. This method uses variable ambient humidity, coupon/module temperature, and dust composition within a single custom-made chamber to create a natural and uniform soil deposition layer. Antisoiling (AS) coatings from two different manufacturers were applied on two one-cell monocrystalline silicon modules. Three layers of Arizona road dust have been deposited on the one-cell modules with AS coatings and an uncoated one-cell reference module at varied humidity levels. The soiled modules were exposed to an open-circuit subsonic wind tunnel at varying speeds and the effectiveness of AS coatings have been quantified using the transmittance gain. Transmittance loss resulting from the AS coating has been measured and compared with the transmittance of the uncoated reference module using a reflectance spectrophotometer. Reflectance measurements have also been taken to compare the transmittance loss of Arizona road dust and soil collected from PV modules’ superstrates. The soiled one-cell modules were then exposed to rain from a rain simulator. The transmittance gain due to rain exposure is quantified using a rain gain and rain coefficient. These tests cumulatively may be used to help develop a test standard for evaluating the effectiveness of AS coatings.
- 2 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 9 (1) , 227-232
Indoor Soil Deposition Chamber: Evaluating Effectiveness of Antisoiling Coatings
An indoor soil deposition method has been developed to simulate natural soil deposition on glass coupons or one-cell and multicell photovoltaic (PV) modules. This method uses variable ambient humidity, coupon/module temperature, and dust composition within a single custom-made chamber to create a natural and uniform soil deposition layer. Antisoiling (AS) coatings from two different manufacturers were applied on two one-cell monocrystalline silicon modules. Three layers of Arizona road dust have been deposited on the one-cell modules with AS coatings and an uncoated one-cell reference module at varied humidity levels. The soiled modules were exposed to an open-circuit subsonic wind tunnel at varying speeds and the effectiveness of AS coatings have been quantified using the transmittance gain. Transmittance loss resulting from the AS coating has been measured and compared with the transmittance of the uncoated reference module using a reflectance spectrophotometer. Reflectance measurements have also been taken to compare the transmittance loss of Arizona road dust and soil collected from PV modules’ superstrates. The soiled one-cell modules were then exposed to rain from a rain simulator. The transmittance gain due to rain exposure is quantified using a rain gain and rain coefficient. These tests cumulatively may be used to help develop a test standard for evaluating the effectiveness of AS coatings.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3407-3412
Design and Operation of a Waterless PV Soiling Monitoring Station
ASU-PRL has developed an autonomous, waterless, and wireless soiling monitoring station for photovoltaic (PV) plants. This soiling monitoring station is a 4 th generation design, featuring: two split-cell coupons as sensors coplanar to the PV arrays (two soiled half-cells and two covered clean half-cells), utilizing remote web-monitoring, and capable of providing data for up to 13 different useful ratios. This design employs built-in heat sinks which eliminates the need for temperature correction of the monitored short-circuit current. This paper presents the design and operation of a waterless PV soiling monitoring station and how it differs from currently available soiling monitoring stations on the market as well as a data set obtained from different PV plants located in diverse climates to quantify the operation and methodology.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3407-3412
Design and Operation of a Waterless PV Soiling Monitoring Station
ASU-PRL has developed an autonomous, waterless, and wireless soiling monitoring station for photovoltaic (PV) plants. This soiling monitoring station is a 4 th generation design, featuring: two split-cell coupons as sensors coplanar to the PV arrays (two soiled half-cells and two covered clean half-cells), utilizing remote web-monitoring, and capable of providing data for up to 13 different useful ratios. This design employs built-in heat sinks which eliminates the need for temperature correction of the monitored short-circuit current. This paper presents the design and operation of a waterless PV soiling monitoring station and how it differs from currently available soiling monitoring stations on the market as well as a data set obtained from different PV plants located in diverse climates to quantify the operation and methodology.