Evgenii Belykh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Evgenii Belykh has a total of 255 co-authors. Here are the top co-authors by number of shared publications:
- Vadim Anatolyevich Byvaltsev
Irkutsk State Medical University
38 shared publications Mark C. Preul
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona
30 shared publicationsPeter Nakaji
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
15 shared publications- Kaan Yağmurlu
Department of Neurological Surgery, University of Virginia Health System, Charlottesville, Virginia, USA
14 shared publications Robert F. Spetzler
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix
9 shared publicationsTing Lei
Department of Neurosurgery, Barrow Neurological Institute, St. Joseph's Hospital and Medical Center, Phoenix, Arizona, USA
9 shared publications
Latest Publications
- 26 March 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (6) , 1188-1189
Multimodal Approach to the Management of a Carotid Body Tumor With Preoperative Direct Puncture Embolization Followed by Surgical Resection: A 2-Dimensional Operative Video
- 26 March 2026
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (6) , 1188-1189
Multimodal Approach to the Management of a Carotid Body Tumor With Preoperative Direct Puncture Embolization Followed by Surgical Resection: A 2-Dimensional Operative Video
- 7 November 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (1) , 173
Management of Intraoperative Air Embolism into the Spinal Cord due to Hydrogen Peroxide Irrigation: 2-Dimensional Operative Video
- 7 November 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 31 (1) , 173
Management of Intraoperative Air Embolism into the Spinal Cord due to Hydrogen Peroxide Irrigation: 2-Dimensional Operative Video
- 16 June 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (4) , 623
Transdural Approach for Repair of a Spontaneous Ventral Thoracic Cerebrospinal Fluid Leak Using Muscle Plug: 2-Dimensional Operative Video
- 16 June 2025
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 30 (4) , 623
Transdural Approach for Repair of a Spontaneous Ventral Thoracic Cerebrospinal Fluid Leak Using Muscle Plug: 2-Dimensional Operative Video
- 3 December 2024
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 29 (3) , 345-350
External Ventricular Drain Misadministration Events: Systematic Literature Review and Report of a Case
BACKGROUND AND OBJECTIVES: External ventricular drain (EVD) is a common neurosurgical procedure with potential complications, including catheter misplacement, infection, mechanical obstruction, and inadvertent catheter pull-out. A less discussed but critical complication is the misadministration of medications into EVD. This project aimed to review the literature on EVD misadministration and discuss preventative measures, emphasizing the new International Organization for Standardization (ISO) standard for neuraxial connectors. METHODS: A systematic review of PubMed, Embase, and SCOPUS databases was conducted to identify studies reporting misadministration in EVD systems. We also present a case of misadministration of a blood product into an EVD. Factors contributing to these events were researched, relevant guidelines from professional organizations were reviewed, and preventive strategies, including the novel NRFit® connector designed to prevent such errors, were discussed. RESULTS: The literature review identified 7 reports of 8 cases of misadministration involving substances such as gadolinium-based contrast agents, anesthetic agents, and antiepileptic drugs. In addition, we report a case of an 87-year-old man with multiple traumatic brain injuries, where a blood transfusion line was mistakenly connected to the EVD. This incident is the first reported case of blood misadministration through EVD. Despite immediate drainage and flushing of the EVD system with saline, the patient's condition did not improve, and he eventually died. Contributing factors included unfamiliarity with the EVD system, similarity to IV connectors, and poor visibility during procedures. Importantly, the novel ISO 80369 standard for all neuraxial connectors, including NRFit® connectors that have a 20% smaller nozzle outside diameter than traditional Luer connectors, has been recommended to prevent misconnection errors and mitigate associated risks. CONCLUSION: Misadministration to EVD connectors is a preventable event that highlights the need for enhanced safety solutions. Adoption of ISO standard neuraxial connectors, thorough training, and the use of distinctly marked equipment are critical steps in minimizing risks.
- 3 December 2024
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 29 (3) , 345-350
External Ventricular Drain Misadministration Events: Systematic Literature Review and Report of a Case
BACKGROUND AND OBJECTIVES: External ventricular drain (EVD) is a common neurosurgical procedure with potential complications, including catheter misplacement, infection, mechanical obstruction, and inadvertent catheter pull-out. A less discussed but critical complication is the misadministration of medications into EVD. This project aimed to review the literature on EVD misadministration and discuss preventative measures, emphasizing the new International Organization for Standardization (ISO) standard for neuraxial connectors. METHODS: A systematic review of PubMed, Embase, and SCOPUS databases was conducted to identify studies reporting misadministration in EVD systems. We also present a case of misadministration of a blood product into an EVD. Factors contributing to these events were researched, relevant guidelines from professional organizations were reviewed, and preventive strategies, including the novel NRFit® connector designed to prevent such errors, were discussed. RESULTS: The literature review identified 7 reports of 8 cases of misadministration involving substances such as gadolinium-based contrast agents, anesthetic agents, and antiepileptic drugs. In addition, we report a case of an 87-year-old man with multiple traumatic brain injuries, where a blood transfusion line was mistakenly connected to the EVD. This incident is the first reported case of blood misadministration through EVD. Despite immediate drainage and flushing of the EVD system with saline, the patient's condition did not improve, and he eventually died. Contributing factors included unfamiliarity with the EVD system, similarity to IV connectors, and poor visibility during procedures. Importantly, the novel ISO 80369 standard for all neuraxial connectors, including NRFit® connectors that have a 20% smaller nozzle outside diameter than traditional Luer connectors, has been recommended to prevent misconnection errors and mitigate associated risks. CONCLUSION: Misadministration to EVD connectors is a preventable event that highlights the need for enhanced safety solutions. Adoption of ISO standard neuraxial connectors, thorough training, and the use of distinctly marked equipment are critical steps in minimizing risks.
- 27 September 2024
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 29 (1) , 141
Microsurgical “Onion-Peeling” Technique for Resection of Shamblin Grade III Succinate Dehydrogenase Carotid Body Paraganglioma: 2-Dimensional Operative Video
- 27 September 2024
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 29 (1) , 141
Microsurgical “Onion-Peeling” Technique for Resection of Shamblin Grade III Succinate Dehydrogenase Carotid Body Paraganglioma: 2-Dimensional Operative Video
- Open Access
- 10 September 2024
- Published by Irkutsk State Medical University in Baikal Medical Journal
- Vol. 3 (3) , 55-62
RARE CASE OF ULNAR NERVE TUMOR: INTRANEURAL GANGLIOUS CYST
Relevance. Differential diagnostics of volumetric formations of peripheral nerves and their semiotics using magnetic resonance imaging is one of the most complex sections in neurosurgery. A rare cause of compression-ischemic neuropathy of peripheral nerves are intraneural ganglionic cysts. Case descriptions. The manuscript presents a rare case of an intraneural ganglion cyst of the ulnar nerve, which caused compression-ischemic neuropathy of the ulnar nerve with a lesion level in the cubital canal. After a detailed comprehensive clinical and instrumental examination, preoperative planning was carried out. Given the presence of a clear dissection plane, the use of microsurgical techniques made it possible to perform total tumor removal without compromising the integrity of the ulnar nerve with complete regression of compression-ischemic neuropathy. An intraneural ganglion cyst was histologically confirmed. Conclusion. If clinical manifestations of compression-ischemic neuropathy of the ulnar nerve at the level of the cubital canal are detected in a patient, in addition to ultrasound examination and electroneuromyography, magnetic resonance imaging is necessary to exclude a space-occupying formation in this area. Microsurgical removal of a ganglion cyst is a highly effective treatment method that allows you to preserve the integrity of the peripheral nerve and its sheaths, as well as achieve complete regression of symptoms.
- 10 September 2024
- Published by Irkutsk State Medical University in Baikal Medical Journal
- Vol. 3 (3) , 55-62
Open AccessRARE CASE OF ULNAR NERVE TUMOR: INTRANEURAL GANGLIOUS CYST
Relevance. Differential diagnostics of volumetric formations of peripheral nerves and their semiotics using magnetic resonance imaging is one of the most complex sections in neurosurgery. A rare cause of compression-ischemic neuropathy of peripheral nerves are intraneural ganglionic cysts. Case descriptions. The manuscript presents a rare case of an intraneural ganglion cyst of the ulnar nerve, which caused compression-ischemic neuropathy of the ulnar nerve with a lesion level in the cubital canal. After a detailed comprehensive clinical and instrumental examination, preoperative planning was carried out. Given the presence of a clear dissection plane, the use of microsurgical techniques made it possible to perform total tumor removal without compromising the integrity of the ulnar nerve with complete regression of compression-ischemic neuropathy. An intraneural ganglion cyst was histologically confirmed. Conclusion. If clinical manifestations of compression-ischemic neuropathy of the ulnar nerve at the level of the cubital canal are detected in a patient, in addition to ultrasound examination and electroneuromyography, magnetic resonance imaging is necessary to exclude a space-occupying formation in this area. Microsurgical removal of a ganglion cyst is a highly effective treatment method that allows you to preserve the integrity of the peripheral nerve and its sheaths, as well as achieve complete regression of symptoms.
- 21 August 2023
- Published by Elsevier in World Neurosurgery
- Vol. 179, 104-108
Laminectomy with Laminar Reconstruction for Resection of Intradural Tumors at the Thoracolumbar Junction: A Technical Note
- 21 August 2023
- Published by Elsevier in World Neurosurgery
- Vol. 179, 104-108
Laminectomy with Laminar Reconstruction for Resection of Intradural Tumors at the Thoracolumbar Junction: A Technical Note
- Open Access
- 30 June 2023
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 17 (3) , 595-609
Laminoplasty versus Laminectomy in the Treatment of Primary Spinal Cord Tumors in Adult Patients: A Systematic Review and Meta-analysis of Observational Studies
The present systematic review and meta-analysis was conducted to compare the safety and efficacy of the two approaches for primary spinal cord tumors (PSCTs) in adult patients (laminoplasty [LP] vs. laminectomy [LE]). LE is one of the most common procedures for PSCTs. Despite advantages of LP, it is not yet widely used in the neurosurgical community worldwide. The efficacy of LP vs. LE remains controversial. Adult patients over 18 years of age with PSCT at the level of the cervical, thoracic, and lumbar spine were included in the study. A literature search was performed in MEDLINE via PubMed, EMBASE, The Cochrane Library, and Google Scholar up to December 2021. Operation time, hospital stay, complications, and incidence of postoperative spinal deformity (kyphosis or scoliosis were extracted. A total of seven retrospective observational studies with 540 patients were included. There were no significant differences between LP and LE group in operation time (p =0.25) and complications (p =0.48). The LE group showed larger postoperative spinal deformity rate than the LP group (odds ratio, 0.47; 95% confidence interval [CI], 0.27−0.84; p =0.01). The LP group had a shorter hospital stay (standardized mean differences, −0.68; 95% CI, −1.03 to −0.34; p =0.0001) than the LE group. Both LP and LE have comparable operative times and total complications in the treatment of PSCT. LP was superior to LE in hospital stay and postoperative spinal deformity rate. However, these findings are limited by the very low quality of the available evidence. Randomized controlled trials are needed for further comparison.
- 30 June 2023
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 17 (3) , 595-609
Open AccessLaminoplasty versus Laminectomy in the Treatment of Primary Spinal Cord Tumors in Adult Patients: A Systematic Review and Meta-analysis of Observational Studies
The present systematic review and meta-analysis was conducted to compare the safety and efficacy of the two approaches for primary spinal cord tumors (PSCTs) in adult patients (laminoplasty [LP] vs. laminectomy [LE]). LE is one of the most common procedures for PSCTs. Despite advantages of LP, it is not yet widely used in the neurosurgical community worldwide. The efficacy of LP vs. LE remains controversial. Adult patients over 18 years of age with PSCT at the level of the cervical, thoracic, and lumbar spine were included in the study. A literature search was performed in MEDLINE via PubMed, EMBASE, The Cochrane Library, and Google Scholar up to December 2021. Operation time, hospital stay, complications, and incidence of postoperative spinal deformity (kyphosis or scoliosis were extracted. A total of seven retrospective observational studies with 540 patients were included. There were no significant differences between LP and LE group in operation time (p =0.25) and complications (p =0.48). The LE group showed larger postoperative spinal deformity rate than the LP group (odds ratio, 0.47; 95% confidence interval [CI], 0.27−0.84; p =0.01). The LP group had a shorter hospital stay (standardized mean differences, −0.68; 95% CI, −1.03 to −0.34; p =0.0001) than the LE group. Both LP and LE have comparable operative times and total complications in the treatment of PSCT. LP was superior to LE in hospital stay and postoperative spinal deformity rate. However, these findings are limited by the very low quality of the available evidence. Randomized controlled trials are needed for further comparison.
- 28 March 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (5) , 1644-1654
Clinical and radiological outcomes of one-level cervical corpectomy with an expandable cage for three-column uncomplicated subaxial type «B» injures: a multicenter retrospective study
Purpose To evaluate the clinical and radiological results of the operative management of three-column uncomplicated type «B» subaxial injures treated with a one-level cervical corpectomy with an expandable cage. Methods This study included 72 patients with a three-column uncomplicated type «B» subaxial injures who met the inclusion criteria, underwent a one-level cervical corpectomy with an expandable cage at one of three neurosurgical departments between 2005 and 2020, and were followed up for clinical and radiological outcomes at a minimum 3-yr follow-up. Results There was a decrease in the VAS pain score from an average of 80 mm to 7 mm (p = 0.03); a decrease in the average NDI score from 62 to 14% (p = 0.01); excellent and good outcomes according to Macnab’s scale were 93% (n = 67/72). There was an average change in the cervical lordosis (Cobb method) from −9.10 to −15.40 (p = 0.007), without significant loss of lordosis (p = 0.27). There was no significant degeneration of the adjacent levels by 3 years post-op. The fusion rate, using the Cervical Spine Research Society criteria, was poor: it was 62.5% (n = 45/72), and using the CT criteria, it was 65.3% (n = 47/72). 15.4% patients (n = 11/72) suffered complications. Statistical difference between the fusion and pseudoarthrosis (according to X-ray criteria) subgroups showed that there were no statistically significant differences in the smoking status, diabetes, chronic steroid use, cervical injury level, subtypes of AO type B subaxial injuries and types of expandable cage systems. Conclusions One-level cervical corpectomy with an expandable cage, despite a poor fusion rate, can be considered a feasible and relatively safe method for treating three-column uncomplicated subaxial type «B» injures, with the benefit of immediate stability, anatomical reduction, and direct decompression of the spinal cord. While no one in our series had any catastrophic complications, we did note a high complication rate.
- 28 March 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (5) , 1644-1654
Clinical and radiological outcomes of one-level cervical corpectomy with an expandable cage for three-column uncomplicated subaxial type «B» injures: a multicenter retrospective study
Purpose To evaluate the clinical and radiological results of the operative management of three-column uncomplicated type «B» subaxial injures treated with a one-level cervical corpectomy with an expandable cage. Methods This study included 72 patients with a three-column uncomplicated type «B» subaxial injures who met the inclusion criteria, underwent a one-level cervical corpectomy with an expandable cage at one of three neurosurgical departments between 2005 and 2020, and were followed up for clinical and radiological outcomes at a minimum 3-yr follow-up. Results There was a decrease in the VAS pain score from an average of 80 mm to 7 mm (p = 0.03); a decrease in the average NDI score from 62 to 14% (p = 0.01); excellent and good outcomes according to Macnab’s scale were 93% (n = 67/72). There was an average change in the cervical lordosis (Cobb method) from −9.10 to −15.40 (p = 0.007), without significant loss of lordosis (p = 0.27). There was no significant degeneration of the adjacent levels by 3 years post-op. The fusion rate, using the Cervical Spine Research Society criteria, was poor: it was 62.5% (n = 45/72), and using the CT criteria, it was 65.3% (n = 47/72). 15.4% patients (n = 11/72) suffered complications. Statistical difference between the fusion and pseudoarthrosis (according to X-ray criteria) subgroups showed that there were no statistically significant differences in the smoking status, diabetes, chronic steroid use, cervical injury level, subtypes of AO type B subaxial injuries and types of expandable cage systems. Conclusions One-level cervical corpectomy with an expandable cage, despite a poor fusion rate, can be considered a feasible and relatively safe method for treating three-column uncomplicated subaxial type «B» injures, with the benefit of immediate stability, anatomical reduction, and direct decompression of the spinal cord. While no one in our series had any catastrophic complications, we did note a high complication rate.