Xiaoyu Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaoyu Zhou has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Zheng Ouyang
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
17 shared publications Caiqiao Xiong
Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry Chinese Academy of Sciences and Beijing National Laboratory for Molecular Sciences , Beijing 100190, China
13 shared publications- Zongxiu Nie
Ningxia University
10 shared publications Zheng Ouyang
9 shared publicationsRui Chen
Key Laboratory of Analytical Chemistry for Living Biosystems Institute of Chemistry Chinese Academy of Sciences Beijing 100190 China
8 shared publications- Wen-Ping Peng
Department of Physics, National Dong Hwa University, Shoufeng, Hualien, 97401, Taiwan
8 shared publications
Latest Publications
- 25 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (39) , 21384-21391
MALDI Mass Spectrometry Imaging of Metal Ions and Metabolites in Tissues Using a Bifunctional Matrix
Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a powerful technique for spatially resolved analysis of diverse molecular species within biological tissues. However, the simultaneous imaging of metal ions and small-molecule metabolites remains analytically challenging due to their distinct chemical properties and desorption/ionization behaviors. Herein, 5,6-diamino-1,10-phenanthroline (DAP) hydrochloride was introduced as a bifunctional matrix that enables concurrent MALDI-MS imaging of metal ions and endogenous metabolites from the same tissue section. In the positive ion mode, DAP forms stable chelation complexes with metal ions, enhancing their ionization efficiency while preserving spatial localization. In negative ion mode, DAP hydrochloride exhibits excellent matrix properties for the efficient desorption and ionization of a wide range of endogenous metabolites. This strategy was successfully applied to tissue sections, achieving high-quality imaging of both metal ions and metabolites without the need for additional matrix coating. Our results demonstrate that DAP hydrochloride serves as a versatile and efficient matrix for multimodal molecular imaging and offers a promising platform for investigating metal-metabolite interactions in situ.
- 25 September 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (39) , 21384-21391
MALDI Mass Spectrometry Imaging of Metal Ions and Metabolites in Tissues Using a Bifunctional Matrix
Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) is a powerful technique for spatially resolved analysis of diverse molecular species within biological tissues. However, the simultaneous imaging of metal ions and small-molecule metabolites remains analytically challenging due to their distinct chemical properties and desorption/ionization behaviors. Herein, 5,6-diamino-1,10-phenanthroline (DAP) hydrochloride was introduced as a bifunctional matrix that enables concurrent MALDI-MS imaging of metal ions and endogenous metabolites from the same tissue section. In the positive ion mode, DAP forms stable chelation complexes with metal ions, enhancing their ionization efficiency while preserving spatial localization. In negative ion mode, DAP hydrochloride exhibits excellent matrix properties for the efficient desorption and ionization of a wide range of endogenous metabolites. This strategy was successfully applied to tissue sections, achieving high-quality imaging of both metal ions and metabolites without the need for additional matrix coating. Our results demonstrate that DAP hydrochloride serves as a versatile and efficient matrix for multimodal molecular imaging and offers a promising platform for investigating metal-metabolite interactions in situ.
- Open Access
- 25 April 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (6) , 1023-1032
Electrospray-assisted cryo-EM sample preparation to mitigate interfacial effects
Addressing interfacial effects during specimen preparation in cryogenic electron microscopy remains challenging. Here we introduce ESI-cryoPrep, a specimen preparation method based on electrospray ionization in native mass spectrometry, designed to alleviate issues associated with protein denaturation or preferred orientation induced by macromolecule adsorption at interfaces. Through fine-tuning spraying parameters, we optimized protein integrity preservation and achieved the desired ice thickness for analyzing target macromolecules. With ESI-cryoPrep, we prepared high-quality cryo-specimens of five proteins and obtained three-dimensional reconstructions at near-atomic resolution. Our findings demonstrate that ESI-cryoPrep effectively confines macromolecules within the middle of the thin layer of amorphous ice, facilitating the preparation of blotting-free vitreous samples. The protective mechanism, characterized by the uneven distribution of charged biomolecules of varying sizes within charged droplets, prevents the adsorption of target biomolecules at air–water or graphene–water interfaces, thereby avoiding structural damage to the protein particles or the introduction of dominant orientation issues.
- 25 April 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (6) , 1023-1032
Open AccessElectrospray-assisted cryo-EM sample preparation to mitigate interfacial effects
Addressing interfacial effects during specimen preparation in cryogenic electron microscopy remains challenging. Here we introduce ESI-cryoPrep, a specimen preparation method based on electrospray ionization in native mass spectrometry, designed to alleviate issues associated with protein denaturation or preferred orientation induced by macromolecule adsorption at interfaces. Through fine-tuning spraying parameters, we optimized protein integrity preservation and achieved the desired ice thickness for analyzing target macromolecules. With ESI-cryoPrep, we prepared high-quality cryo-specimens of five proteins and obtained three-dimensional reconstructions at near-atomic resolution. Our findings demonstrate that ESI-cryoPrep effectively confines macromolecules within the middle of the thin layer of amorphous ice, facilitating the preparation of blotting-free vitreous samples. The protective mechanism, characterized by the uneven distribution of charged biomolecules of varying sizes within charged droplets, prevents the adsorption of target biomolecules at air–water or graphene–water interfaces, thereby avoiding structural damage to the protein particles or the introduction of dominant orientation issues.
- Open Access
- 4 April 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 15 (18) , 6853-6859
Accelerating protein aggregation and amyloid fibrillation for rapid inhibitor screening
Amyloidosis has been found to be linked to numerous devastating neurodegenerative diseases. Here, we show that proteins in microdroplets accelerate to form fibrils in milliseconds, enabling inhibitor screening for Aβ40 within 3 minutes.
- 4 April 2024
- Published by Royal Society of Chemistry (RSC) in Chemical Science
- Vol. 15 (18) , 6853-6859
Open AccessAccelerating protein aggregation and amyloid fibrillation for rapid inhibitor screening
Amyloidosis has been found to be linked to numerous devastating neurodegenerative diseases. Here, we show that proteins in microdroplets accelerate to form fibrils in milliseconds, enabling inhibitor screening for Aβ40 within 3 minutes.
- 9 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6683) , 612-618
Differentiating enantiomers by directional rotation of ions in a mass spectrometer
Conventional mass spectrometry does not distinguish between enantiomers, or mirror-image isomers. Here we report a technique to break the chiral symmetry and to differentiate enantiomers by inducing directional rotation of chiral gas-phase ions. Dual alternating current excitations were applied to manipulate the motions of trapped ions, including the rotation around the center of mass and macro movement around the center of the trap. Differences in collision cross section were induced, which could be measured by ion cloud profiling at high resolutions above 10,000. High-field ion mobility and tandem mass spectrometry analyses of the enantiomers were combined and implemented by using a miniature ion trap mass spectrometer. The effectiveness of the developed method was demonstrated with a variety of organic compounds including amino acids, sugars, and several drug molecules, as well as a proof-of-principle ligand optimization study for asymmetric hydrogenation.
- 9 February 2024
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 383 (6683) , 612-618
Differentiating enantiomers by directional rotation of ions in a mass spectrometer
Conventional mass spectrometry does not distinguish between enantiomers, or mirror-image isomers. Here we report a technique to break the chiral symmetry and to differentiate enantiomers by inducing directional rotation of chiral gas-phase ions. Dual alternating current excitations were applied to manipulate the motions of trapped ions, including the rotation around the center of mass and macro movement around the center of the trap. Differences in collision cross section were induced, which could be measured by ion cloud profiling at high resolutions above 10,000. High-field ion mobility and tandem mass spectrometry analyses of the enantiomers were combined and implemented by using a miniature ion trap mass spectrometer. The effectiveness of the developed method was demonstrated with a variety of organic compounds including amino acids, sugars, and several drug molecules, as well as a proof-of-principle ligand optimization study for asymmetric hydrogenation.
- 11 July 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (29) , 11099-11105
Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry
In the past decade, mass spectrometry (MS) has been widely used for a broad range of on-site applications. This is largely attributed to the rapid advancement of technologies, such as ambient ionization and mass spectrometer miniaturization. Here, we report the development of the temperature-tuning desorption ionization (TTDI) method for versatile on-site applications using a miniature MS system. A unique feature of TTDI is its dynamic temperature range applicable from 30 to 800 °C, which enables optimal desorption ionization applied for chemical and biological compounds through tuning the temperature at the sampling spot. The versatility of TTDI has been demonstrated through on-site MS analysis of a variety of samples, such as explosives on surfaces, drugs of abuse in biofluids, and screening biomarkers in tissues.
- 11 July 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (29) , 11099-11105
Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry
In the past decade, mass spectrometry (MS) has been widely used for a broad range of on-site applications. This is largely attributed to the rapid advancement of technologies, such as ambient ionization and mass spectrometer miniaturization. Here, we report the development of the temperature-tuning desorption ionization (TTDI) method for versatile on-site applications using a miniature MS system. A unique feature of TTDI is its dynamic temperature range applicable from 30 to 800 °C, which enables optimal desorption ionization applied for chemical and biological compounds through tuning the temperature at the sampling spot. The versatility of TTDI has been demonstrated through on-site MS analysis of a variety of samples, such as explosives on surfaces, drugs of abuse in biofluids, and screening biomarkers in tissues.
- Open Access
- 20 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-6
High-resolution separation of bioisomers using ion cloud profiling
Elucidation of complex structures of biomolecules plays a key role in the field of chemistry and life sciences. In the past decade, ion mobility, by coupling with mass spectrometry, has become a unique tool for distinguishing isomers and isoforms of biomolecules. In this study, we develop a concept for performing ion mobility analysis using an ion trap, which enables isomer separation under ultra-high fields to achieve super high resolutions over 10,000. The potential of this technology has been demonstrated for analysis of isomers for biomolecules including disaccharides, phospholipids, and peptides with post-translational modifications.
- 20 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-6
Open AccessHigh-resolution separation of bioisomers using ion cloud profiling
Elucidation of complex structures of biomolecules plays a key role in the field of chemistry and life sciences. In the past decade, ion mobility, by coupling with mass spectrometry, has become a unique tool for distinguishing isomers and isoforms of biomolecules. In this study, we develop a concept for performing ion mobility analysis using an ion trap, which enables isomer separation under ultra-high fields to achieve super high resolutions over 10,000. The potential of this technology has been demonstrated for analysis of isomers for biomolecules including disaccharides, phospholipids, and peptides with post-translational modifications.
- 31 January 2022
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 149, 116548
Recent advances in on-site mass spectrometry analysis for clinical applications
- 31 January 2022
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 149, 116548
Recent advances in on-site mass spectrometry analysis for clinical applications
- 8 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (15) , 5998-6002
Mass Analysis Using Collective Interaction of Ions in an Ion Trap
The ion trap is a unique type of device that is used for quantum studies in physics and mass analysis in chemistry. The space charge effect, which is due to trapping of an excessive number of ions, has long been recognized to be harmful for ion manipulation or mass spectrometry analysis. Here, we show an interesting phenomenon in which the energy exchange through collective interaction between the ion species could be effectively used for ion manipulation and high-quality mass measurement. This observation not only reveals a fundamentally interesting process in ion trap operation but also suggests a new alternative means for mass analysis.
- 8 April 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (15) , 5998-6002
Mass Analysis Using Collective Interaction of Ions in an Ion Trap
The ion trap is a unique type of device that is used for quantum studies in physics and mass analysis in chemistry. The space charge effect, which is due to trapping of an excessive number of ions, has long been recognized to be harmful for ion manipulation or mass spectrometry analysis. Here, we show an interesting phenomenon in which the energy exchange through collective interaction between the ion species could be effectively used for ion manipulation and high-quality mass measurement. This observation not only reveals a fundamentally interesting process in ion trap operation but also suggests a new alternative means for mass analysis.
- 27 July 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (17) , 12049-12054
A Gas-Phase Reaction Accelerator Using Vortex Flows
Gas-phase microdroplets have been increasingly used for reaction acceleration. Here, we report the development of a vortex tube as a reaction accelerator. Three types of reactions, viz., aromatization, amination isomerization, and acid-induced cytochrome c unfolding were used to characterize the performance of the vortex tube. During ion transfer from a nanoelectrospray ionization (nanoESI) source to the mass spectrometry (MS) inlet, the generated vortex flows helped droplets desolvation and ion confinement and thus improved the MS intensity by 2~3 orders of magnitude compared with that the vortex tube wasn’t applied. Like the stirring effect in bulk phase, the reactants were more sufficiently mixed and reacted in vortices. Therefore, with the same reaction distance, 2~3 folds improvement of conversion ratios was observed by using the vortices. Notably, the vortex tube enabled the use of flow rate to control the reaction time for ~60 μs, which was useful for precise control of reaction progress. As a demonstration, the intermediates of the amination isomerization were tracked and the equilibrium constant and rate constant of the cytochrome c unfolding were determined.
- 27 July 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (17) , 12049-12054
A Gas-Phase Reaction Accelerator Using Vortex Flows
Gas-phase microdroplets have been increasingly used for reaction acceleration. Here, we report the development of a vortex tube as a reaction accelerator. Three types of reactions, viz., aromatization, amination isomerization, and acid-induced cytochrome c unfolding were used to characterize the performance of the vortex tube. During ion transfer from a nanoelectrospray ionization (nanoESI) source to the mass spectrometry (MS) inlet, the generated vortex flows helped droplets desolvation and ion confinement and thus improved the MS intensity by 2~3 orders of magnitude compared with that the vortex tube wasn’t applied. Like the stirring effect in bulk phase, the reactants were more sufficiently mixed and reacted in vortices. Therefore, with the same reaction distance, 2~3 folds improvement of conversion ratios was observed by using the vortices. Notably, the vortex tube enabled the use of flow rate to control the reaction time for ~60 μs, which was useful for precise control of reaction progress. As a demonstration, the intermediates of the amination isomerization were tracked and the equilibrium constant and rate constant of the cytochrome c unfolding were determined.