Saeid Sadri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Saeid Sadri has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Rasoul Amirfattahi
Digital Signal Processing Research Lab, Department of Electrical and Computer Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
3 shared publicationsAlireza Aghaie
Department of Computer, Islamic Azad University, Najafabad Branch, Isfahan, Iran
2 shared publications- Mojgan Mokhtari
Department of Pathology, Isfahan University of Medical Sciences, Isfahan, Iran
2 shared publications Abolghasem Zeidaabadi Nezhad
Isfahan University of Technology, Iran
1 shared publicationGholamreza Askari
Information and Communication Technology Institute (ICTI), Portugal
1 shared publication- Mahdie Rezaeian
Macquarie Univ, Fac Med & Hlth Sci, Dept Clin Med, Sydney, NSW, Australia
1 shared publication
Latest Publications
- Open Access
- 22 July 2013
- Published by Wiley in BioMed Research International
- Vol. 2013, 1-12
Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline
We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach.
- 22 July 2013
- Published by Wiley in BioMed Research International
- Vol. 2013, 1-12
Open AccessNonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline
We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography images because of complex nonrigid motions that exist in this type of angiography images. Multiresolution and iterative algorithms are proposed to cope with this problem, but these algorithms are associated with high computational cost which makes them not acceptable for real-time clinical applications. In this paper we propose a nonrigid image registration algorithm for coronary angiography images that is significantly faster than multiresolution and iterative blocking methods and outperforms competing algorithms evaluated on the same data sets. This algorithm is based on a sparse set of matched feature point pairs and the elastic registration is performed by means of multilevel B-spline image warping. Experimental results with several clinical data sets demonstrate the effectiveness of our approach.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Detection of Collagenous Colitis Based on Histopathology Image Segmentation of Colon
Collagenous colitis is prevalent among pathological diseases. Because of normal radiological and endoscopic appearances, the microscopic image of colon tissue is necessary and important material for investigation of this disease. In this paper, a computerized system is developed for collagenous colitis diagnosis. First, colon tissues are colored with Mason trichrome to make sub-epithelial collagen band to be appeared in blue. Second, preprocessing is done on the microscopic image of colon tissue, and then Color histogram features in HSV color space and Haar Wavelet energy in detail coefficients of sub-band images are implemented to characterize the histological structure representation for tissue classification. KNN Classifier is selected for this classification, which segments the sub-epithelial collagen band from the image, and finally, thickness of sub-epithelial collagen band is determined by morphological operations. Abnormal case will be recognized if the thickness of sub-epithelial collagen band be more than 10 μm. Fifty clinical image samples were employed in the training and testing procedures for the evaluation of system performance. Through the applied classification it was revealed that collagenous colitis can be diagnosed accurately.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Detection of Collagenous Colitis Based on Histopathology Image Segmentation of Colon
Collagenous colitis is prevalent among pathological diseases. Because of normal radiological and endoscopic appearances, the microscopic image of colon tissue is necessary and important material for investigation of this disease. In this paper, a computerized system is developed for collagenous colitis diagnosis. First, colon tissues are colored with Mason trichrome to make sub-epithelial collagen band to be appeared in blue. Second, preprocessing is done on the microscopic image of colon tissue, and then Color histogram features in HSV color space and Haar Wavelet energy in detail coefficients of sub-band images are implemented to characterize the histological structure representation for tissue classification. KNN Classifier is selected for this classification, which segments the sub-epithelial collagen band from the image, and finally, thickness of sub-epithelial collagen band is determined by morphological operations. Abnormal case will be recognized if the thickness of sub-epithelial collagen band be more than 10 μm. Fifty clinical image samples were employed in the training and testing procedures for the evaluation of system performance. Through the applied classification it was revealed that collagenous colitis can be diagnosed accurately.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21666776) , 1-5
Accurate Coronary Vessel Extraction Using Fast Directional Filter Bank
Correct discern of blood vessels performs a significant role in a number of clinical applications, especially in angiographic image analysis. In this paper, we propose a new simple and fast fabrication of DDFB (called FDFB) without necessity of downsampling and resampling employed in DDFB, which is time consuming, especially if the directions are sizeable. Also, in this paper we discuss on parameters of vessel filter in more detail and propose a proper range for parameters selection to achieve accurate vessel enhancement. One major problem in automatic segmentation is the presence of background non-vessel structures; we use a morphological-based algorithm to remove these, after vessel enhancement. Another problem with DDFB is the ringing artefact; smoothed FDFB unravels the later. The experimental results show that the proposed FDFB and vessel enhancement framework work well on angiograms.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3 (21666776) , 1-5
Accurate Coronary Vessel Extraction Using Fast Directional Filter Bank
Correct discern of blood vessels performs a significant role in a number of clinical applications, especially in angiographic image analysis. In this paper, we propose a new simple and fast fabrication of DDFB (called FDFB) without necessity of downsampling and resampling employed in DDFB, which is time consuming, especially if the directions are sizeable. Also, in this paper we discuss on parameters of vessel filter in more detail and propose a proper range for parameters selection to achieve accurate vessel enhancement. One major problem in automatic segmentation is the presence of background non-vessel structures; we use a morphological-based algorithm to remove these, after vessel enhancement. Another problem with DDFB is the ringing artefact; smoothed FDFB unravels the later. The experimental results show that the proposed FDFB and vessel enhancement framework work well on angiograms.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21647054,p. 105-107
A new quasi-elliptic UWB BPF with a sharp transition band using 3/4-wavelength SIRs
A new ultra-wideband (UWB) bandpass filter composed of two parallel coupled stepped impedance resonators (SIRs) is proposed. Each resonator is tapped with stepped-impedance open stubs at its center providing a very sharp transition band and two uniform open stubs at the junctions of the low- and high-impedance sections to slide the upper resonant modes. Two interdigital parallel coupled lines are used to enhance couplings at input and output of the circuit. A planar UWB bandpass filter with a quasi-elliptic function response and a fractional bandwidth of about 110% (from 3.1GHz to 10.6GHz) is designed and simulated by Ansoft HFSS EM simulator. Simulated response of the filter shows an insertion loss of 0.6 dB, a return loss of 15 dB and a flat group delay of 0.4 ns in the passband.
- 1 May 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21647054,p. 105-107
A new quasi-elliptic UWB BPF with a sharp transition band using 3/4-wavelength SIRs
A new ultra-wideband (UWB) bandpass filter composed of two parallel coupled stepped impedance resonators (SIRs) is proposed. Each resonator is tapped with stepped-impedance open stubs at its center providing a very sharp transition band and two uniform open stubs at the junctions of the low- and high-impedance sections to slide the upper resonant modes. Two interdigital parallel coupled lines are used to enhance couplings at input and output of the circuit. A planar UWB bandpass filter with a quasi-elliptic function response and a fractional bandwidth of about 110% (from 3.1GHz to 10.6GHz) is designed and simulated by Ansoft HFSS EM simulator. Simulated response of the filter shows an insertion loss of 0.6 dB, a return loss of 15 dB and a flat group delay of 0.4 ns in the passband.