MOMacduff O. Okuom

Macduff O. Okuom

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Macduff O. Okuom has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Using Fluorescence Intensity of Enhanced Green Fluorescent Protein to Quantify Pseudomonas aeruginosa

    by Erin Wilson, Macduff Okuom, Nathan Kyes, Dylan Mayfield, Christina Wilson, Derek Sabatka, Jasmin Sandoval, Jared R. Foote, Michael J. Kangas, Andrea E. Holmes, et al.

    A variety of direct and indirect methods have been used to quantify planktonic and biofilm bacterial cells. Direct counting methods to determine the total number of cells include plate counts, microscopic cell counts, Coulter cell counting, flow cytometry, and fluorescence microscopy. However, indirect methods are often used to supplement direct cell counting, as they are often more convenient, less time-consuming, and require less material, while providing a number that can be related to the direct cell count. Herein, an indirect method is presented that uses fluorescence emission intensity as a proxy marker for studying bacterial accumulation. A clinical strain of Pseudomonas aeruginosa was genetically modified to express a green fluorescent protein (PA14/EGFP). The fluorescence intensity of EGFP in live cells was used as an indirect measure of live cell density, and was compared with the traditional cell counting methods of optical density (OD600) and plate counting (colony-forming units (CFUs)). While both OD600 and CFUs are well-established methods, the use of fluorescence spectroscopy to quantify bacteria is less common. This study demonstrates that EGFP intensity is a convenient reporter for bacterial quantification. In addition, we demonstrate the potential for fluorescence spectroscopy to be used to measure the quantity of PA14/EGFP biofilms, which have important human health implications due to their antimicrobial resistance. Therefore, fluorescence spectroscopy could serve as an alternative or complementary quick assay to quantify bacteria in planktonic cultures and biofilms.


  • Open Access

    Applied Circular Dichroism: A Facile Spectroscopic Tool for Configurational Assignment and Determination of Enantiopurity

    by Macduff O. Okuom, Raychelle Burks, Crysta Naylor, Andrea E. Holmes

    In order to determine if electronic circular dichroism (ECD) is a good tool for the qualitative evaluation of absolute configuration and enantiopurity in the absence of chiral high performance liquid chromatography (HPLC), ECD studies were performed on several prescriptions and over-the-counter drugs. Cotton effects (CE) were observed for both S and R isomers between 200 and 300 nm. For the drugs examined in this study, the S isomers showed a negative CE, while the R isomers displayed a positive CE. The ECD spectra of both enantiomers were nearly mirror images, with the amplitude proportional to the enantiopurity. Plotting the differential extinction coefficient (Δε) versus enantiopurity at the wavelength of maximum amplitude yielded linear standard curves with coefficients of determination (R2) greater than 97% for both isomers in all cases. As expected, Equate, Advil, and Motrin, each containing a racemic mixture of ibuprofen, yielded no chiroptical signal. ECD spectra of Suphedrine and Sudafed revealed that each of them is rich in 1S,2S-pseudoephedrine, while the analysis of Equate vapor inhaler is rich in R-methamphetamine.


  • Open Access

    Intermolecular Interactions between Eosin Y and Caffeine Using1H-NMR Spectroscopy

    by Macduff O. Okuom, Mark V. Wilson, Abby Jackson, Andrea E. Holmes

    DETECHIP has been used in testing analytes including caffeine, cocaine, and tetrahydrocannabinol (THC) from marijuana, as well as date rape and club drugs such as flunitrazepam, gamma-hydroxybutyric acid (GHB), and methamphetamine. This study investigates the intermolecular interaction between DETECHIP sensor eosin Y (DC1) and the analyte (caffeine) that is responsible for the fluorescence and color changes observed in the actual array. Using1H-NMR,1H-COSY, and1H-DOSY NMR methods, a proton exchange from C-8 of caffeine to eosin Y is proposed.