Manuel Ferretti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manuel Ferretti has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Luongo
University of L’Aquila
38 shared publications - Simona Di Nino
Department of Civil, Construction-Architectural and Environmental Engineering, University of L’Aquila, 67100 L’Aquila, Italy
17 shared publications - Francesco Annibale
University of L’Aquila
14 shared publications - Daniele Zulli
Department of Civil, Construction-Architectural and Environmental Engineering, University of L’Aquila, L’Aquila, Italy
10 shared publications Angelo Luongo
8 shared publications- Angelo Di Egidio
Department of Civil, Construction-Architectural and Environmental Engineering, University of L’Aquila, 67100 L’Aquila, Italy
4 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 122
Cascade of restabilizations along linear fundamental paths of axially soft multi-degree-of-freedom statical systems
- 25 October 2026
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 122
Open AccessCascade of restabilizations along linear fundamental paths of axially soft multi-degree-of-freedom statical systems
- Open Access
- 24 September 2026
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 122
Critical and postcritical effects of the rotary damping on the Beck’s beam
- 24 September 2026
- Published by Elsevier in European Journal of Mechanics - A/Solids
- Vol. 122
Open AccessCritical and postcritical effects of the rotary damping on the Beck’s beam
- Open Access
- 24 August 2026
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 114 (16) , 1071
Reduced-order analytical modeling for the protection of pipelines in utility tunnels under longitudinal seismic excitation
This study presents a strategy to enhance the longitudinal seismic performance of pipelines installed in underground tunnels crossing different soil types. The approach combines longitudinal base isolation of the pipeline from the tunnel with advanced control devices, specifically Hysteretic Mass Damper Inerters (HMDIs), i.e., oscillators with hysteretic coupling grounded via inerters. A reduced-order mechanical model is developed, in which the pipeline and tunnel are represented in the longitudinal direction as one-dimensional truss elements coupled through visco-elastic links, the surrounding soil is modeled as a tangential Winkler-type visco-elastic foundation, and the presence of HMDIs, connected to the pipeline, is considered. The equations of motion are derived using the Extended Hamilton Principle and discretized via the Rayleigh–Ritz method. After validation against a Finite Element benchmark, the analytical model is used for extensive parametric time-history analyses under representative seismic inputs. Results show that longitudinal base isolation significantly reduces the forces transmitted through the coupling supports, at the expense of increased pipeline displacements. However, a suitable design of the HMDIs effectively mitigates these increased displacements while further reducing the transmitted forces.
- 24 August 2026
- Published by Springer Nature in Nonlinear Dynamics
- Vol. 114 (16) , 1071
Open AccessReduced-order analytical modeling for the protection of pipelines in utility tunnels under longitudinal seismic excitation
This study presents a strategy to enhance the longitudinal seismic performance of pipelines installed in underground tunnels crossing different soil types. The approach combines longitudinal base isolation of the pipeline from the tunnel with advanced control devices, specifically Hysteretic Mass Damper Inerters (HMDIs), i.e., oscillators with hysteretic coupling grounded via inerters. A reduced-order mechanical model is developed, in which the pipeline and tunnel are represented in the longitudinal direction as one-dimensional truss elements coupled through visco-elastic links, the surrounding soil is modeled as a tangential Winkler-type visco-elastic foundation, and the presence of HMDIs, connected to the pipeline, is considered. The equations of motion are derived using the Extended Hamilton Principle and discretized via the Rayleigh–Ritz method. After validation against a Finite Element benchmark, the analytical model is used for extensive parametric time-history analyses under representative seismic inputs. Results show that longitudinal base isolation significantly reduces the forces transmitted through the coupling supports, at the expense of increased pipeline displacements. However, a suitable design of the HMDIs effectively mitigates these increased displacements while further reducing the transmitted forces.
- 23 August 2026
- Published by SAGE Publications in Journal of Vibration and Control
Seismic performance of base-isolated rigid-block systems enhanced by parallel tuned mass damper–inerter arrays
This study investigates the seismic performance of rigid-block-like structures equipped with a base isolation system enhanced by an array of parallel tuned mass damper–inerter devices (TMDIs). The protected structure, a typical data-center server rack, is modeled as a rigid cabinet that may experience uplift, rocking motion, and overturning under strong ground excitation. A comprehensive mechanical model is developed to describe the coupled rocking–translational dynamics of the cabinet, the isolation base, and the attached TMDI system, including impact and failure conditions. An extensive parametric investigation is carried out by varying the isolation period, the number and mass ratio of the TMDs, as well as the inertance associated with both the isolation base and the TMDs. The dynamic response is systematically evaluated through behavior maps, which identify full-contact, rocking, and overturning regimes in selected parameter planes. Numerical simulations are performed considering two cabinets with different slenderness and three historical earthquake records with distinct spectral characteristics. The results demonstrate that the proposed protection strategy is capable of significantly enlarging the safe response region, reducing both the minimum isolation period required to prevent uplift and the maximum displacement of the isolated base. Inerters attached to the TMDs are found to be particularly effective, while base-connected inerters provide additional benefits when combined with TMDIs. The effectiveness of the system is shown to depend on cabinet slenderness and seismic input characteristics. Overall, the study highlights the potential of parallel TMDI arrays as a robust and flexible solution for enhancing the seismic response of base-isolated rigid-block structures.
- 23 August 2026
- Published by SAGE Publications in Journal of Vibration and Control
Seismic performance of base-isolated rigid-block systems enhanced by parallel tuned mass damper–inerter arrays
This study investigates the seismic performance of rigid-block-like structures equipped with a base isolation system enhanced by an array of parallel tuned mass damper–inerter devices (TMDIs). The protected structure, a typical data-center server rack, is modeled as a rigid cabinet that may experience uplift, rocking motion, and overturning under strong ground excitation. A comprehensive mechanical model is developed to describe the coupled rocking–translational dynamics of the cabinet, the isolation base, and the attached TMDI system, including impact and failure conditions. An extensive parametric investigation is carried out by varying the isolation period, the number and mass ratio of the TMDs, as well as the inertance associated with both the isolation base and the TMDs. The dynamic response is systematically evaluated through behavior maps, which identify full-contact, rocking, and overturning regimes in selected parameter planes. Numerical simulations are performed considering two cabinets with different slenderness and three historical earthquake records with distinct spectral characteristics. The results demonstrate that the proposed protection strategy is capable of significantly enlarging the safe response region, reducing both the minimum isolation period required to prevent uplift and the maximum displacement of the isolated base. Inerters attached to the TMDs are found to be particularly effective, while base-connected inerters provide additional benefits when combined with TMDIs. The effectiveness of the system is shown to depend on cabinet slenderness and seismic input characteristics. Overall, the study highlights the potential of parallel TMDI arrays as a robust and flexible solution for enhancing the seismic response of base-isolated rigid-block structures.
- 25 July 2026
- Published by SAGE Publications in Journal of Vibration and Control
Are tuned mass damper-controlled systems quasi-semi-simple or quasi-defective?
A two- DOF system, known as the Den Hartog Oscillator , made of a single- DOF, representative of a main structure, equipped with a Tuned Mass Damper , is analyzed as a prototype of passively controlled structures. The eigenvalues and eigenvectors of the system are asymptotically determined according to two different procedures. The first one, known in literature, takes as starting point of the integer series expansions a double semi-simple eigenvalue (i.e., admitting two distinct eigenvectors). The second, which is believed to be original, starts the expansion from a double defective eigenvalue (i.e., admitting just one eigenvector), and therefore is carried out in terms of fractional series expansions. The two approaches are found to lead to the same asymptotic results; however, the newer one is considered to be conceptually superior (and therefore more easily exported in other similar problems), since the fractional dependence on parameters, which is the main reason of the good performance of the Tuned Mass Damper, has not to be guessed, but naturally appears in the treatment. Moreover, the underlying quasi-defective nature of the Den Hartog Oscillator explains why the oscillation amplitude of the Tuned Mass Damper is larger than that of the main structure, since the modes are perturbations of a unique mode, in which just the added mass moves, while the structure is at rest.
- 25 July 2026
- Published by SAGE Publications in Journal of Vibration and Control
Are tuned mass damper-controlled systems quasi-semi-simple or quasi-defective?
A two- DOF system, known as the Den Hartog Oscillator , made of a single- DOF, representative of a main structure, equipped with a Tuned Mass Damper , is analyzed as a prototype of passively controlled structures. The eigenvalues and eigenvectors of the system are asymptotically determined according to two different procedures. The first one, known in literature, takes as starting point of the integer series expansions a double semi-simple eigenvalue (i.e., admitting two distinct eigenvectors). The second, which is believed to be original, starts the expansion from a double defective eigenvalue (i.e., admitting just one eigenvector), and therefore is carried out in terms of fractional series expansions. The two approaches are found to lead to the same asymptotic results; however, the newer one is considered to be conceptually superior (and therefore more easily exported in other similar problems), since the fractional dependence on parameters, which is the main reason of the good performance of the Tuned Mass Damper, has not to be guessed, but naturally appears in the treatment. Moreover, the underlying quasi-defective nature of the Den Hartog Oscillator explains why the oscillation amplitude of the Tuned Mass Damper is larger than that of the main structure, since the modes are perturbations of a unique mode, in which just the added mass moves, while the structure is at rest.
- Open Access
- 30 June 2026
- Published by Elsevier in Structures
- Vol. 90
Beneficial effects of TMDs with embedded vibro-impacting mass on fully isolated rigid block-like structures
- 30 June 2026
- Published by Elsevier in Structures
- Vol. 90
Open AccessBeneficial effects of TMDs with embedded vibro-impacting mass on fully isolated rigid block-like structures
- Open Access
- 29 June 2026
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 643
General multi-DOF systems equipped with a tuned mass damper: Perturbation analysis and reduced models
- 29 June 2026
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 643
Open AccessGeneral multi-DOF systems equipped with a tuned mass damper: Perturbation analysis and reduced models
- Open Access
- 14 March 2026
- Published by Elsevier in Structures
- Vol. 87
Characterization of the nonlinear rocking dynamics of dual isolated asymmetric rigid blocks
- 14 March 2026
- Published by Elsevier in Structures
- Vol. 87
Open AccessCharacterization of the nonlinear rocking dynamics of dual isolated asymmetric rigid blocks
- Open Access
- 25 August 2025
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 179
Static bifurcations of short FPU softening chains with second-order interaction: The non-degenerate case
- 25 August 2025
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 179
Open AccessStatic bifurcations of short FPU softening chains with second-order interaction: The non-degenerate case
- Open Access
- 1 July 2025
- Published by Elsevier in Engineering Structures
- Vol. 341
Characterization of the overturning scenario of asymmetric rigid blocks under one-sine pulse excitation
- 1 July 2025
- Published by Elsevier in Engineering Structures
- Vol. 341
Open AccessCharacterization of the overturning scenario of asymmetric rigid blocks under one-sine pulse excitation