KNKonstantinos Natsis

Konstantinos Natsis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Konstantinos Natsis has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Protecting olympic participants from COVID-19: the trialled and tested process

    by Fabio Pigozzi, Bernd Wolfarth, Ana Cintron Rodriguez, Juergen Michael Steinacker, Victoriya Badtieva, James Lee John Bilzon, Christian Schneider, William O Roberts, Jeroen Swart, Demitri Constantinou, et al.


  • Open Access

    Corrigendum to “Revision of Carpal Tunnel Release due to Palmaris Longus Profundus”

    by Christos Lyrtzis, Konstantinos Natsis, Evagelos Pantazis

    [This corrects the article DOI: 10.1155/2015/616051.].


  • Open Access

    High origin of the third digital branch of the median nerve

    by Konstantinos Natsis


  • Open Access

    Revision of Carpal Tunnel Release due to Palmaris Longus Profundus

    by Lyrtzis Christos, Natsis Konstantinos, Pantazis Evagelos

    Purpose. The palmaris longus profundus has been documented throughout the literature as a cause of carpal tunnel syndrome. We present a case of palmaris profundus tendon removal during the revision of carpal tunnel release. Method. During a carpal tunnel release in a 66-year-old woman, palmaris profundus tendon was found inside the tunnel under the transverse carpal ligament, just above the median nerve, but it was left intact. The patient complained of pain in the hand at night and weakness of her hand one month after surgery. We decided on a revision of the carpal tunnel release. The palmaris profundus tendon was found and was removed. Results. The patient had a normal postoperative course. Two months later she returned to her normal activities and was asymptomatic. Conclusions. When a palmaris profundus muscle is located in carpal tunnel, we recommend its excision during carpal tunnel release. This excision will eliminate the possibility of recurrent compression over the median nerve.


  • Open Access

    Anterior and Posterior Meniscofemoral Ligaments: MRI Evaluation

    by A. Bintoudi, K. Natsis, I. Tsitouridis

    Although meniscofemoral ligaments are distinct anatomic units, their anatomy and function are controversial from an anatomic and radiologic point of view. Five hundred knee MR examinations were retrospectively studied in an effort to demonstrate the incidence and variations regarding sex and age distribution, as well as the anatomy of the meniscofemoral ligament at magnetic resonance imaging. Patients were mostly men, three hundred and twelve, in contrast with women who were fewer, one hundred eighty-eight patients. The mean age of the patients who were included in this study was 46 years. More than half of them were between 20 and 40 years old; one hundred thirty-three patients among 20 to 30 years old and one hundred and one patients among 31 and 40 years old, in total two hundred thirty-four patients.


  • Open Access

    Gender and Side-to-Side Differences of Femoral Condyles Morphology: Osteometric Data from 360 Caucasian Dried Femori

    by Ioannis Terzidis, Trifon Totlis, Efthymia Papathanasiou, Aristotelis Sideridis, Konstantinos Vlasis, Konstantinos Natsis

    The purpose of the present study was to conduct direct measurements in a large sample of dried femori in order to record certain morphometric parameters of the femoral condyles and determine whether there are gender and side differences. Three hundred sixty (Greek) Caucasian dried femori (180 left and 180 right), from 192 males and 168 females, were measured using a digital caliper. The mean age was 67.52 years. The mean bicondylar width of the femur was 8.86 cm ± 0.42 cm in men and 7.85 cm ± 0.30 cm in women (). The relative values for the medial condylar depth were 6.11 cm ± 0.34 cm and 5.59 cm ± 0.29 cm (); for the lateral condylar depth were 6.11 cm ± 0.33 cm and 5.54 cm ± 0.21 cm (); for the intercondylar width were 2.20 cm ± 0.18 cm and 1.87 cm ± 0.10 cm (); for the intercondylar depth were 2.78 cm ± 0.16 cm and 2.37 cm ± 0.12 cm (). No significant side-to-side difference was observed in any parameter. The femoral condyles differences in anatomy between genders might be useful to the design of total knee prostheses. The contralateral healthy side can be safely used for preoperative templating since there were no significant side differences.


  • Open Access

    Adequacy of Semitendinosus Tendon Alone for Anterior Cruciate Ligament Reconstruction Graft and Prediction of Hamstring Graft Size by Evaluating Simple Anthropometric Parameters

    by Papastergiou G. Stergios, Konstantinidis A. Georgios, Natsis Konstantinos, Papathanasiou Efthymia, Koukoulias Nikolaos, Papadopoulos G. Alexandros

    Introduction. Preoperative identification of patients with inadequate hamstring grafts for anterior cruciate ligament reconstruction is still a subject of interest. Purpose. The purpose of this study was to determine whether the semitendinosus tendon length is adequate for four-strand graft harvested by common technique (without bone plug) and whether there is correlation of gracilis and semitendinosus tendon grafts length and diameter of quadrupled graft with anthropometric parameters. Materials and Methods. In this retrospective study, 61 patients (45 males, 16 females) undergoing ACL reconstruction using four-strand hamstring autograft tendons were included. Results. The length of semitendinosus tendon, harvested by the common technique, was in 21% of our cases inadequate in order to be used alone as a four-strand graft especially in females (43%). There was moderate correlation between semitendinosus and gracilis graft diameter and patient’s height and weight and fair correlation to BMI. We found no statistically important predictor for graft diameter in female patients. Conclusions. The length of semitendinosus tendon, harvested by common technique, is usually inadequate to be used alone as a four-strand graft especially in females. The most reliable predictor seems to be patient’s height in males. In female patients, there is no statistically important predictor.