Arto S. Pennanen
Research Subjects
Arto S. Pennanen has a total of 192 co-authors. Here are the top co-authors by number of shared publications:
Risto Hillamo
Atmospheric Composition Research, Finnish Meteorological Institute, Helsinki, Finland
17 shared publicationsRaimo O. Salonen
Finnish Institute for Health and Welfare, Finland
16 shared publicationsMaija-Riitta Hirvonen
Department of Environmental Health, National Institute for Health and Welfare, Kuopio, Finland Department of Environmental Science, University of Eastern Finland, Kuopio, Finland
12 shared publicationsTimo Lanki
Department of Environmental Health, National Institute for Health and Welfare, Kuopio, Finland
10 shared publicationsMarkus Sillanpää
Air Quality Research, Finnish Meteorological Institute (FMI), Helsinki, Finland
9 shared publications- Bert Brunekreef
Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
8 shared publications
Latest Publications
- Open Access
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01103
Studying the efficiency of air cleaners at removing various indoor air impurities in classrooms and the relation to pupils’ symptoms
The existing knowledge on the effect of air cleaners in reducing different indoor impurities and health symptoms in real-life applications is still insufficient. PUHHO study aimed to fill this knowledge gap with a blinded intervention study in 18 primary school classrooms. The study was conducted during 8 weeks with 2 weeks without air cleaner, 3 weeks with air cleaner in full operation (filtration) with moderate airflow (200 - 400 m3/h) and 3 weeks sham operation (air cleaner blowing air without filtration). The latter two interventions were conducted in a blinded and mixed setup. Small, but statistically non-significant reductions in particulate matter levels (PM2.5; particulate matter with diameter less than 2.5 µm and PM10; diameter of particles less than 10 µm) were observed when comparing air cleaner filtration to air recirculation alone (sham operation). The use of air cleaners had no significant effect on the level of total volatile organic compounds (TVOC). Air cleaners did not have significant effect on the microbial levels or on the microbiome of the classrooms. Filtration by air cleaners was found to statistically significantly reduce upper (4.0%) and lower airway (2.5%) and other (4.0%) symptoms, but a nearly equivalent effect was observed with air recirculation alone.
- 16 June 2023
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 396, 01103
Open AccessStudying the efficiency of air cleaners at removing various indoor air impurities in classrooms and the relation to pupils’ symptoms
The existing knowledge on the effect of air cleaners in reducing different indoor impurities and health symptoms in real-life applications is still insufficient. PUHHO study aimed to fill this knowledge gap with a blinded intervention study in 18 primary school classrooms. The study was conducted during 8 weeks with 2 weeks without air cleaner, 3 weeks with air cleaner in full operation (filtration) with moderate airflow (200 - 400 m3/h) and 3 weeks sham operation (air cleaner blowing air without filtration). The latter two interventions were conducted in a blinded and mixed setup. Small, but statistically non-significant reductions in particulate matter levels (PM2.5; particulate matter with diameter less than 2.5 µm and PM10; diameter of particles less than 10 µm) were observed when comparing air cleaner filtration to air recirculation alone (sham operation). The use of air cleaners had no significant effect on the level of total volatile organic compounds (TVOC). Air cleaners did not have significant effect on the microbial levels or on the microbiome of the classrooms. Filtration by air cleaners was found to statistically significantly reduce upper (4.0%) and lower airway (2.5%) and other (4.0%) symptoms, but a nearly equivalent effect was observed with air recirculation alone.
- Open Access
- 5 December 2014
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 72 (4) , 277-283
Source-specific fine particulate air pollution and systemic inflammation in ischaemic heart disease patients
To compare short-term effects of fine particles (PM2.5; aerodynamic diameter <2.5 µm) from different sources on the blood levels of markers of systemic inflammation. We followed a panel of 52 ischaemic heart disease patients from 15 November 2005 to 21 April 2006 with clinic visits in every second week in the city of Kotka, Finland, and determined nine inflammatory markers from blood samples. In addition, we monitored outdoor air pollution at a fixed site during the study period and conducted a source apportionment of PM2.5 using the Environmental Protection Agency's model EPA PMF 3.0. We then analysed associations between levels of source-specific PM2.5 and markers of systemic inflammation using linear mixed models. We identified five source categories: regional and long-range transport (LRT), traffic, biomass combustion, sea salt, and pulp industry. We found most evidence for the relation of air pollution and inflammation in LRT, traffic and biomass combustion; the most relevant inflammation markers were C-reactive protein, interleukin-12 and myeloperoxidase. Sea salt was not positively associated with any of the inflammatory markers. Results suggest that PM2.5 from several sources, such as biomass combustion and traffic, are promoters of systemic inflammation, a risk factor for cardiovascular diseases.
- 5 December 2014
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 72 (4) , 277-283
Open AccessSource-specific fine particulate air pollution and systemic inflammation in ischaemic heart disease patients
To compare short-term effects of fine particles (PM2.5; aerodynamic diameter <2.5 µm) from different sources on the blood levels of markers of systemic inflammation. We followed a panel of 52 ischaemic heart disease patients from 15 November 2005 to 21 April 2006 with clinic visits in every second week in the city of Kotka, Finland, and determined nine inflammatory markers from blood samples. In addition, we monitored outdoor air pollution at a fixed site during the study period and conducted a source apportionment of PM2.5 using the Environmental Protection Agency's model EPA PMF 3.0. We then analysed associations between levels of source-specific PM2.5 and markers of systemic inflammation using linear mixed models. We identified five source categories: regional and long-range transport (LRT), traffic, biomass combustion, sea salt, and pulp industry. We found most evidence for the relation of air pollution and inflammation in LRT, traffic and biomass combustion; the most relevant inflammation markers were C-reactive protein, interleukin-12 and myeloperoxidase. Sea salt was not positively associated with any of the inflammatory markers. Results suggest that PM2.5 from several sources, such as biomass combustion and traffic, are promoters of systemic inflammation, a risk factor for cardiovascular diseases.
- 1 September 2014
- Published by Elsevier in Science of The Total Environment
- Vol. 493, 298-306
The association of LUR modeled PM2.5 elemental composition with personal exposure
- 1 September 2014
- Published by Elsevier in Science of The Total Environment
- Vol. 493, 298-306
The association of LUR modeled PM2.5 elemental composition with personal exposure
- 1 April 2014
- Published by Elsevier in Atmospheric Environment
- Vol. 87, 239-248
Spatial variations of PAH, hopanes/steranes and EC/OC concentrations within and between European study areas
- 1 April 2014
- Published by Elsevier in Atmospheric Environment
- Vol. 87, 239-248
Spatial variations of PAH, hopanes/steranes and EC/OC concentrations within and between European study areas
- 1 December 2013
- Published by Elsevier in Environmental Pollution
- Vol. 183, 104-112
Does urban vegetation mitigate air pollution in northern conditions?
- 1 December 2013
- Published by Elsevier in Environmental Pollution
- Vol. 183, 104-112
Does urban vegetation mitigate air pollution in northern conditions?
- 12 July 2013
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 47 (15) , 8523-31
Agreement of Land Use Regression Models with Personal Exposure Measurements of Particulate Matter and Nitrogen Oxides Air Pollution
Land use regression (LUR) models are often used to predict long-term average concentrations of air pollutants. Little is known how well LUR models predict personal exposure. In this study, the agreement of LUR models with measured personal exposure was assessed. The measured components were particulate matter with a diameter smaller than 2.5 μm (PM2.5), soot (reflectance of PM2.5), nitrogen oxides (NOx), and nitrogen dioxide (NO2). In Helsinki, Utrecht, and Barcelona, 15 volunteers (from semiurban, urban background, and traffic sites) followed prescribed time activity patterns. Per participant, six 96 h outdoor, indoor, and personal measurements spread over three seasons were conducted. Soot LUR models were significantly correlated with measured average outdoor and personal soot concentrations. Soot LUR models explained 39%, 44%, and 20% of personal exposure variability (R2) in Helsinki, Utrecht, and Barcelona. NO2 LUR models significantly predicted outdoor concentrations and personal exposure in Utrecht and Helsinki, whereas NOx and PM2.5 LUR models did not predict personal exposure. PM2.5, NO2, and NOx models were correlated with personal soot, the component least affected by indoor sources. LUR modeled and measured outdoor, indoor, and personal concentrations were highly correlated for all pollutants when data from the three cities were combined. This study supports the use of intraurban LUR models for especially soot in air pollution epidemiology.
- 12 July 2013
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 47 (15) , 8523-31
Agreement of Land Use Regression Models with Personal Exposure Measurements of Particulate Matter and Nitrogen Oxides Air Pollution
Land use regression (LUR) models are often used to predict long-term average concentrations of air pollutants. Little is known how well LUR models predict personal exposure. In this study, the agreement of LUR models with measured personal exposure was assessed. The measured components were particulate matter with a diameter smaller than 2.5 μm (PM2.5), soot (reflectance of PM2.5), nitrogen oxides (NOx), and nitrogen dioxide (NO2). In Helsinki, Utrecht, and Barcelona, 15 volunteers (from semiurban, urban background, and traffic sites) followed prescribed time activity patterns. Per participant, six 96 h outdoor, indoor, and personal measurements spread over three seasons were conducted. Soot LUR models were significantly correlated with measured average outdoor and personal soot concentrations. Soot LUR models explained 39%, 44%, and 20% of personal exposure variability (R2) in Helsinki, Utrecht, and Barcelona. NO2 LUR models significantly predicted outdoor concentrations and personal exposure in Utrecht and Helsinki, whereas NOx and PM2.5 LUR models did not predict personal exposure. PM2.5, NO2, and NOx models were correlated with personal soot, the component least affected by indoor sources. LUR modeled and measured outdoor, indoor, and personal concentrations were highly correlated for all pollutants when data from the three cities were combined. This study supports the use of intraurban LUR models for especially soot in air pollution epidemiology.
- Top Cited Papers
- 1 December 2012
- Published by Elsevier in Atmospheric Environment
- Vol. 62, 303-317
Spatial variation of PM2.5, PM10, PM2.5 absorbance and PMcoarse concentrations between and within 20 European study areas and the relationship with NO2 – Results of the ESCAPE project
- 1 December 2012
- Published by Elsevier in Atmospheric Environment
- Vol. 62, 303-317
Top Cited PapersSpatial variation of PM2.5, PM10, PM2.5 absorbance and PMcoarse concentrations between and within 20 European study areas and the relationship with NO2 – Results of the ESCAPE project
- 1 July 2012
- Published by Elsevier in Environmental Research
- Vol. 116, 44-51
Low-level exposure to ambient particulate matter is associated with systemic inflammation in ischemic heart disease patients
- 1 July 2012
- Published by Elsevier in Environmental Research
- Vol. 116, 44-51
Low-level exposure to ambient particulate matter is associated with systemic inflammation in ischemic heart disease patients
- 30 September 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (10) , 3183-3195
A novel particle sampling system for physico-chemical and toxicological characterization of emissions
Several studies have shown that combustion-derived fine particles cause adverse health effects. Previous toxicological studies on combustion-derived fine particles have rarely involved multiple endpoints and a detailed characterization of chemical composition. In this study, we developed a novel particle sampling system for toxicological and chemical characterization (PSTC), consisting of the Dekati Gravimetric Impactor (DGI) and a porous tube diluter. Physico-chemical and toxicological properties of the particles emitted from various combustion sources were evaluated in two measurement campaigns. First, the DGI was compared with the High-Volume Cascade Impactor (HVCI) and to the Dekati Low-Pressure Impactor (DLPI), using the same dilution system and the same sampling conditions. Only small differences were observed in the mass size distributions, total particulate matter (PM), and particulate matter with diameter smaller than 1 um (PM1) concentrations and geometric mass mean diameters (GMMD) between these three impactors. Second, the PSTC was compared with the HVCI sampling system, which has been optimal for collection of particulate samples for toxicological and chemical analyses. Differences were observed in the mass size distributions, total PM and PM1 emissions, and GMMDs, probably due to the different sampling and dilution methods as well as different sampling substrates which affected the behavior of semi-volatile and volatile organic compounds. However, no significant differences were detected in the in vitro measurements of cytotoxicity between the samples collected with the PSTC and the HVCI systems. In measurements of genotoxicity, significant differences between the two sampling systems were seen only with the particles emitted from the sauna stove. In conclusion, due to compact size, PSTC is an applicable method for use in particle sampling as part of the toxicological and chemical characterization of particulate emissions from different combustion sources. It offers some advantages compared to the previously used high-volume sampling methods including compactness for field measurements, simple preparation of sample substrates and high extraction efficiency.
- 30 September 2011
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 401 (10) , 3183-3195
A novel particle sampling system for physico-chemical and toxicological characterization of emissions
Several studies have shown that combustion-derived fine particles cause adverse health effects. Previous toxicological studies on combustion-derived fine particles have rarely involved multiple endpoints and a detailed characterization of chemical composition. In this study, we developed a novel particle sampling system for toxicological and chemical characterization (PSTC), consisting of the Dekati Gravimetric Impactor (DGI) and a porous tube diluter. Physico-chemical and toxicological properties of the particles emitted from various combustion sources were evaluated in two measurement campaigns. First, the DGI was compared with the High-Volume Cascade Impactor (HVCI) and to the Dekati Low-Pressure Impactor (DLPI), using the same dilution system and the same sampling conditions. Only small differences were observed in the mass size distributions, total particulate matter (PM), and particulate matter with diameter smaller than 1 um (PM1) concentrations and geometric mass mean diameters (GMMD) between these three impactors. Second, the PSTC was compared with the HVCI sampling system, which has been optimal for collection of particulate samples for toxicological and chemical analyses. Differences were observed in the mass size distributions, total PM and PM1 emissions, and GMMDs, probably due to the different sampling and dilution methods as well as different sampling substrates which affected the behavior of semi-volatile and volatile organic compounds. However, no significant differences were detected in the in vitro measurements of cytotoxicity between the samples collected with the PSTC and the HVCI systems. In measurements of genotoxicity, significant differences between the two sampling systems were seen only with the particles emitted from the sauna stove. In conclusion, due to compact size, PSTC is an applicable method for use in particle sampling as part of the toxicological and chemical characterization of particulate emissions from different combustion sources. It offers some advantages compared to the previously used high-volume sampling methods including compactness for field measurements, simple preparation of sample substrates and high extraction efficiency.
- 13 September 2011
- Published by Environmental Health Perspectives in ISEE Conference Abstracts
- Vol. 2011 (1)
VALIDATION OF EXPOSURE ASSESSMENT IN ESCAPE, THE VE3SPA PROJECT
Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences. Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences.
- 13 September 2011
- Published by Environmental Health Perspectives in ISEE Conference Abstracts
- Vol. 2011 (1)
VALIDATION OF EXPOSURE ASSESSMENT IN ESCAPE, THE VE3SPA PROJECT
Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences. Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences.