YAYves Pascal Acklin

Yves Pascal Acklin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yves Pascal Acklin has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Intramedullary nail deflection correlates to mismatch of a 1.5 m vs 1.0 m femoral nail bow design: a biomechanical human cadaveric study

    by Yves P. Acklin, Huan Yuan, Peter Varga, Beat Schmutz, R. Geoff Richards, Markus Windolf, Boyko Gueorguiev, Ivan Zderic

  • Open Access

    Classification of inertial sensor‐based gait patterns of orthopaedic conditions using machine learning: A pilot study

    by Constanze Dammeyer, Corina Nüesch, Rosa M. S. Visscher, Yong K. Kim, Petros Ismailidis, Matthias Wittauer, Karl Stoffel, Yves Acklin, Christian Egloff, Cordula Netzer, et al.

    Elderly patients often have more than one disease that affects walking behavior. An objective tool to identify which disease is the main cause of functional limitations may aid clinical decision making. Therefore, we investigated whether gait patterns could be used to identify degenerative diseases using machine learning. Data were extracted from a clinical database that included sagittal joint angles and spatiotemporal parameters measured using seven inertial sensors, and anthropometric data of patients with unilateral knee or hip osteoarthritis, lumbar or cervical spinal stenosis, and healthy controls. Various classification models were explored using the MATLAB Classification Learner app, and the optimizable Support Vector Machine was chosen as the best performing model. The accuracy of discrimination between healthy and pathologic gait was 82.3%, indicating that it is possible to distinguish pathological from healthy gait. The accuracy of discrimination between the different degenerative diseases was 51.4%, indicating the similarities in gait patterns between diseases need to be further explored. Overall, the differences between pathologic and healthy gait are distinct enough to classify using a classical machine learning model; however, routinely recorded gait characteristics and anthropometric data are not sufficient for successful discrimination of the degenerative diseases.


  • Extraction force, energy and nail deformation for 1.5 m versus 1.0 m intramedullary femoral nail bow design: A biomechanical investigation

    by Huan Yuan, Beat Schmutz, Peter Varga, Boyko Gueorguiev, Ivan Zderic, Markus Windolf, Yves Acklin


  • Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty

    by Mark Lenz, Yves Pascal Acklin, Lena Anna Kasper, Dominic Mischler, Peter Varga, Ivan Zderic, Dominic Gehweiler, Kajetan Klos, Boyko Gueorguiev, Karl Stoffel


  • Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept

    by Ivan Zderic, Daniel Wagner, Clemens Schopper, Moritz Lodde, Geoff Richards, Boyko Gueorguiev, Pol Rommens, Yves P. Acklin

    Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn‐out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw‐in‐screw implant prototype for fragility sacrum fracture fixation. Twenty‐seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw‐in‐screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsional loading applied through the S1 vertebral body to promote turn‐out of the implants. Interfragmentary movements were captured via optical motion tracking. Screw motions were evaluated by means of triggered anteroposterior X‐rays. Interfragmentary movements and implant motions were significantly higher for SI screw fixation compared to both transsacral and screw‐in‐screw fixations. In addition, transsacral screw and screw‐in‐screw fixations revealed similar construct stability. Moreover, screw‐in‐screw fixation successfully prevented turn‐out of the implant that remained during testing at 0° rotation for all specimens. From biomechanical perspective, fragility sacrum fracture fixation with the new screw‐in‐screw implant prototype provides higher stability than an SI screw, being able to successfully prevent turn‐out. Moreover, it combines the higher stability of transsacral screw fixation with the less risky operational procedure of SI screw fixation and can be considered as their alternative treatment option.


  • Benefits of hardware removal after plating

    by Yves P. Acklin, Andreas Bircher, Mario Morgenstern, R. Geoff Richards, Christoph Sommer


  • Open Access

    Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures

    by Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev

    Aims Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking. Results Mean initial stiffness (N/mm) was 581.3 (sd 239.7) for the gliding plate, 631.5 (sd 160.0) for the PHILOS and 440.2 (sd 97.6) for the gliding augmented plate without significant differences between the groups (p = 0.11). Mean varus tilting (°) after 7500 cycles was comparable between the gliding plate (2.6; sd 1.9), PHILOS (1.2; sd 0.6) and gliding augmented plate (1.7; sd 0.9) (p = 0.10). Similarly, mean screw migration(mm) after 7500 cycles was similar between the gliding plate (3.02; sd 2.85), PHILOS (1.30; sd 0.44) and gliding augmented plate (2.83; sd 1.18) (p = 0.13). Mean number of cycles until failure with 5° varus tilting were 12702 (sd 3687) for the gliding plate, 13948 (sd 1295) for PHILOS and 13189 (sd 2647) for the gliding augmented plate without significant differences between the groups (p = 0.66). Conclusion Biomechanically, plate fixation using a new gliding screw technology did not show considerable advantages in comparison with fixation using a standard PHILOS plate. Based on the finding of telescoping of screws, however, it may represent a valid approach for further investigations into how to avoid the cut-out of screws. Cite this article: Y. P. Acklin, I. Zderic, J. A. Inzana, S. Grechenig, R. Schwyn, R. G. Richards, B. Gueorguiev. Biomechanical evaluation of a new gliding screw concept for the fixation of proximal humeral fractures. Bone Joint Res 2018;7:422–429. DOI: 10.1302/2046-3758.76.BJR-2017-0356.R1.


  • Open Access

    Healthcare-resource utilization associated with radiation to bone across eight European countries: Results from a retrospective study

    by Roger von Moos, Jean-Jacques Body, Oliver Guenther, Evangelos Terpos, Yves Pascal Acklin, Jindrich Finek, João Pereira, Nikos Maniadakis, Guy Hechmati, Susan Talbot, et al.


  • Biomechanical investigation of four different fixation techniques in sacrum Denis type II fracture with low bone mineral density

    by Yves P. Acklin, Ivan Zderic, Robert G. Richards, Paul Schmitz, Boyko Gueorguiev, Stephan Grechenig

    With increasing life expectancy, fragility fractures of the pelvic ring are seen more frequently. Although their osteosynthesis can be very challenging, specific biomechanical studies for investigation of the fixation stability are still lacking. The aim of this study was to biomechanically evaluate four different fixation methods for sacrum Denis type II fractures in osteoporotic bone. Unstable Denis type II vertical sacrum fractures were created in 16 human pelves. Their osteosynthesis was performed with one sacro‐iliac screw, posterior sacral plating, triangular fixation, or spino‐pelvic fixation. For that purpose, each pelvis was randomly assigned to two paired groups for treatment with either SI‐screw/posterior sacral plating or triangular fixation/spino‐pelvic fixation. Each hemi‐pelvis was cyclically tested under progressively increasing axial compression. Relative interfragmentary movements were investigated via optical motion tracking analysis. Axial stiffness of triangular fixation was significantly higher versus posterior sacral plating and spino‐pelvic fixation (p ≤ 0.022), but not significantly different in comparison to SI‐screw fixation (p = 0.337). Cycles to 2, 3, 5, and 8 mm fracture displacement, as well as to 3°, 5°, and 8° gap angle at the fracture site were significantly higher for triangular fixation compared to all other groups (p ≤ 0.041). Main failure mode for all osteosynthesis techniques was screw cutting through the bone, leading loss of fixation stability. From a biomechanical point of view, triangular fixation in sacrum Denis type II fractures demonstrated less interfragmentary movements and should be considered in unstable fragility fractures of the sacrum. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1624–1629, 2018.


  • Open Access

    Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

    by Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev

    Objectives: Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. Materials and Methods: A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups Results: Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. Conclusion: From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8–13. DOI: 10.1302/2046-3758.61.BJR-2016-0261.