Siyuan Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Siyuan Wei has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey Brian Fowlkes
University of Michigan
4 shared publications - Chaitali Chakrabarti
Arizona State University, Tempe, AZ, USA
3 shared publications - Jian Zhou
School of Electrical Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
3 shared publications - Thomas F. Wenisch
University of Michigan
3 shared publications Chaitali Chakrabarti
School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ, USA
2 shared publicationsOliver D. Kripfgans
Department of Radiology, University of Michigan, Ann Arbor, MI, USA
2 shared publications
Latest Publications
- 14 June 2024
- Published by Elsevier in Industrial Crops and Products
- Vol. 218, 118991
Removal of methyl orange dye by high surface area biomass activated carbon prepared from bamboo fibers
- 14 June 2024
- Published by Elsevier in Industrial Crops and Products
- Vol. 218, 118991
Removal of methyl orange dye by high surface area biomass activated carbon prepared from bamboo fibers
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 29 (2) , 333-346
Front–End Architecture Design for Low-Complexity 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming
The 3-D ultrasound imaging provides distinct advantages over its 2-D counterpart leading to a more accurate analysis of tumors and cysts. However, the front end of a 3-D system must receive and process data at prodigious rates, making it impractical for power-constrained portable systems. Synthetic aperture sequential beamforming (SASB) is an ultrasound beamforming technique that splits the computation into two stages, such that the computation in Stage 1 can be completed in the power-constrained front end while the remaining computation can be done elsewhere. In this article, we present several algorithmic and architectural techniques to enable efficient computation of Stage 1 processing without compromising imaging quality. Specifically, we present algorithmic techniques that reduce the computational complexity in Stage 1 by $17\times $ through a systematic reduction in the number of apodization coefficients. We propose a 3-D die stacked architecture where the signals received by 961 active transducers are digitized, routed by a network-on-chip, and processed in parallel. This architecture does not require the explicit storage of incoming data samples. We synthesize the architecture using TSMC 28-nm technology node. The front-end power consumption is around 1.5 W, making it suitable for portable applications.
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 29 (2) , 333-346
Front–End Architecture Design for Low-Complexity 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming
The 3-D ultrasound imaging provides distinct advantages over its 2-D counterpart leading to a more accurate analysis of tumors and cysts. However, the front end of a 3-D system must receive and process data at prodigious rates, making it impractical for power-constrained portable systems. Synthetic aperture sequential beamforming (SASB) is an ultrasound beamforming technique that splits the computation into two stages, such that the computation in Stage 1 can be completed in the power-constrained front end while the remaining computation can be done elsewhere. In this article, we present several algorithmic and architectural techniques to enable efficient computation of Stage 1 processing without compromising imaging quality. Specifically, we present algorithmic techniques that reduce the computational complexity in Stage 1 by $17\times $ through a systematic reduction in the number of apodization coefficients. We propose a 3-D die stacked architecture where the signals received by 961 active transducers are digitized, routed by a network-on-chip, and processed in parallel. This architecture does not require the explicit storage of incoming data samples. We synthesize the architecture using TSMC 28-nm technology node. The front-end power consumption is around 1.5 W, making it suitable for portable applications.
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (8) , 1346-1358
High-Volume-Rate 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming With Chirp-Coded Excitation
Three-dimensional (3-D) ultrasound imaging is a promising modality for many medical applications. Unfortunately, it generates voluminous data in the front end, making it unattractive for high-volume-rate portable medical applications. We apply synthetic aperture sequential beamforming (SASB) to greatly compress the front-end receive data. Baseline 3-D SASB has a low volume rate, because subapertures fire one by one. In this paper, we propose to increase the volume rate of 3-D SASB without degrading imaging quality through: 1) transmitting and receiving simultaneously with four subapertures and 2) using linear chirps as the excitation waveform to reduce interference. We design four linear chirps that operate on two overlapped frequency bands with chirp pairs in each band having opposite chirp rates. Direct implementation of this firing scheme results in grating lobes. Therefore, we design a sparse array that mitigates the grating lobe levels through optimizing the locations of transducer elements in the bin-based random array. Compared with the baseline 3-D SASB, the proposed method increases the volume rate from 8.56 to 34.2 volumes/s without increasing the front-end computation requirement. Field-II-based cyst simulations show that the proposed method achieves imaging quality comparable with baseline 3-D SASB in both shallow and deep regions.
- 21 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (8) , 1346-1358
High-Volume-Rate 3-D Ultrasound Imaging Based on Synthetic Aperture Sequential Beamforming With Chirp-Coded Excitation
Three-dimensional (3-D) ultrasound imaging is a promising modality for many medical applications. Unfortunately, it generates voluminous data in the front end, making it unattractive for high-volume-rate portable medical applications. We apply synthetic aperture sequential beamforming (SASB) to greatly compress the front-end receive data. Baseline 3-D SASB has a low volume rate, because subapertures fire one by one. In this paper, we propose to increase the volume rate of 3-D SASB without degrading imaging quality through: 1) transmitting and receiving simultaneously with four subapertures and 2) using linear chirps as the excitation waveform to reduce interference. We design four linear chirps that operate on two overlapped frequency bands with chirp pairs in each band having opposite chirp rates. Direct implementation of this firing scheme results in grating lobes. Therefore, we design a sparse array that mitigates the grating lobe levels through optimizing the locations of transducer elements in the bin-based random array. Compared with the baseline 3-D SASB, the proposed method increases the volume rate from 8.56 to 34.2 volumes/s without increasing the front-end computation requirement. Field-II-based cyst simulations show that the proposed method achieves imaging quality comparable with baseline 3-D SASB in both shallow and deep regions.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
High volume rate 3D ultrasound imaging based on Synthetic Aperture Sequential Beamforming
Synthetic Aperture Sequential Beamforming (SASB) [1] divides the beamforming process into two stages so that only the first stage needs to be done in the front-end and the compressed data for processing the second stage is computed off-chip. However, 3D SASB suffers from low volume rate. Our objective is to increase the volume rate of 3D SASB without increasing the frontend computational rate.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
High volume rate 3D ultrasound imaging based on Synthetic Aperture Sequential Beamforming
Synthetic Aperture Sequential Beamforming (SASB) [1] divides the beamforming process into two stages so that only the first stage needs to be done in the front-end and the compressed data for processing the second stage is computed off-chip. However, 3D SASB suffers from low volume rate. Our objective is to increase the volume rate of 3D SASB without increasing the frontend computational rate.
- Open Access
- 2 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 64 (5) , 772-784
Low-Cost 3-D Flow Estimation of Blood With Clutter
Volumetric flow rate estimation is an important ultrasound medical imaging modality that is used for diagnosing cardiovascular diseases. Flow rates are obtained by integrating velocity estimates over a cross-sectional plane. Speckle tracking is a promising approach that overcomes the angle dependency of traditional Doppler methods, but suffers from poor lateral resolution. Recent work improves lateral velocity estimation accuracy by reconstructing a synthetic lateral phase (SLP) signal. However, the estimation accuracy of such approaches is compromised by the presence of clutter. Eigen-based clutter filtering has been shown to be effective in removing the clutter signal; but it is computationally expensive, precluding its use at high volume rates. In this paper, we propose low-complexity schemes for both velocity estimation and clutter filtering. We use a two-tiered motion estimation scheme to combine the low complexity sum-of-absolute-difference and SLP methods to achieve subpixel lateral accuracy. We reduce the complexity of eigen-based clutter filtering by processing in subgroups and replacing singular value decomposition with less compute-intensive power iteration and subspace iteration methods. Finally, to improve flow rate estimation accuracy, we use kernel power weighting when integrating the velocity estimates. We evaluate our method for fast- and slow-moving clutter for beam-to-flow angles of 90° and 60° using Field II simulations, demonstrating high estimation accuracy across scenarios. For instance, for a beam-to-flow angle of 90° and fast-moving clutter, our estimation method provides a bias of -8.8% and standard deviation of 3.1% relative to the actual flow rate.
- 2 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 64 (5) , 772-784
Open AccessLow-Cost 3-D Flow Estimation of Blood With Clutter
Volumetric flow rate estimation is an important ultrasound medical imaging modality that is used for diagnosing cardiovascular diseases. Flow rates are obtained by integrating velocity estimates over a cross-sectional plane. Speckle tracking is a promising approach that overcomes the angle dependency of traditional Doppler methods, but suffers from poor lateral resolution. Recent work improves lateral velocity estimation accuracy by reconstructing a synthetic lateral phase (SLP) signal. However, the estimation accuracy of such approaches is compromised by the presence of clutter. Eigen-based clutter filtering has been shown to be effective in removing the clutter signal; but it is computationally expensive, precluding its use at high volume rates. In this paper, we propose low-complexity schemes for both velocity estimation and clutter filtering. We use a two-tiered motion estimation scheme to combine the low complexity sum-of-absolute-difference and SLP methods to achieve subpixel lateral accuracy. We reduce the complexity of eigen-based clutter filtering by processing in subgroups and replacing singular value decomposition with less compute-intensive power iteration and subspace iteration methods. Finally, to improve flow rate estimation accuracy, we use kernel power weighting when integrating the velocity estimates. We evaluate our method for fast- and slow-moving clutter for beam-to-flow angles of 90° and 60° using Field II simulations, demonstrating high estimation accuracy across scenarios. For instance, for a beam-to-flow angle of 90° and fast-moving clutter, our estimation method provides a bias of -8.8% and standard deviation of 3.1% relative to the actual flow rate.
- 22 August 2014
- Published by Springer Nature in Journal of Signal Processing Systems
- Vol. 78 (1) , 73-84
High Frame Rate 3-D Ultrasound Imaging Using Separable Beamforming
- 22 August 2014
- Published by Springer Nature in Journal of Signal Processing Systems
- Vol. 78 (1) , 73-84
High Frame Rate 3-D Ultrasound Imaging Using Separable Beamforming