Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


William Collins has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Aerodynamics of manufactured homes and community interference effects

    by Ameyu B. Tolera, Johnny Estephan, Yonathan B. Adamu, Ioannis Zisis, Arindam Gan Chowdhury, Amal Elawady, Thang N. Dao, Elaina J. Sutley, William N. Collins

  • A General Hysteresis Model for Applications in Structural Dynamics

    by Thang N. Dao, Afeez Badmus, Elaina Sutley, William N. Collins, Arindam Chowdhury, Ioannis Zisis, Amal Elawady, Victor Onyia, Vuong N. V. Do

  • Open Access

    In situ assembly enabling adhesive-free bonding of large area electronic sensors to concrete for structural health monitoring

    by Emmanuel Ogunniyi, Han Liu, Austin Rj Downey, Simon Laflamme, Jian Li, Caroline Bennett, William Collins, Hongki Jo, Paul Ziehl

    Cracks developed in concrete infrastructure are one of the primary mechanisms that degrade their structural integrity, which may result in structural failures. Previous research on soft elastomeric capacitors (SEC) has shown their viability for structural health monitoring of structural materials, including concrete, steel, and fiberglass composites. The SEC, or its derivative version with a corrugated geometry termed corrugated SEC or cSEC, is a parallel plate capacitor. Prior work demonstrated that it was possible to directly paint the electrode interfacing with the structural material onto the structure and adhere the rest of the pre-fabricated sensor onto the wet interface, thereby eliminating the need for a joining epoxy. This demonstration was conducted on steel and fiberglass. The study on concrete was left to future work as concrete exhibits a much rougher surface and structure/sensor capacitive coupling, causing a significant amplification in signal noise. This study advances structural health monitoring in concrete applications by investigating the in situ assembly of the SEC on concrete where the carbon black (CB)-based electrode plate of the cSEC is directly painted onto the concrete surface and serves as both the adhesive and electrode for the sensor. A series of free-vibration and compression tests were designed and conducted to evaluate the sensing performance of in situ assembled cSEC compared to that of an epoxy-bonded cSEC. Additionally, the bonding strength of the in situ assembled and epoxy-bonded cSEC is evaluated through a peel test. Results show good strain sensing capabilities of the in situ assembled SEC with an R 2 value of 0.986 and a resolution of 45 ± μ ε . Even though the epoxied cSEC demonstrated a higher bonding strength than the in situ assembled cSEC, the in situ assembled cSEC demonstrated adequate bonding strength for the application. This research contributes to the scientific understanding of sensor adhesion and opens avenues for practical applications in infrastructure monitoring, potentially leading to more resilient and sustainable urban environments.


  • Open Access

    Computer Vision and Augmented Reality for Human-Centered Fatigue Crack Inspection

    by Rushil Mojidra, Jian Li, Ali Mohammadkhorasani, Fernando Moreu, Caroline Bennett, William Collins

    A significant percentage of bridges in the United States are serving beyond their 50-year design life, and many of them are in poor condition, making them vulnerable to fatigue cracks that can result in catastrophic failure. However, current fatigue crack inspection practice based on human vision is time-consuming, labor intensive, and prone to error. We present a novel human-centered bridge inspection methodology to enhance the efficiency and accuracy of fatigue crack detection by employing advanced technologies including computer vision and augmented reality (AR). In particular, a computer vision-based algorithm is developed to enable near-real-time fatigue crack detection by analyzing structural surface motion in a short video recorded by a moving camera of the AR headset. The approach monitors structural surfaces by tracking feature points and measuring variations in distances between feature point pairs to recognize the motion pattern associated with the crack opening and closing. Measuring distance changes between feature points, as opposed to their displacement changes before this improvement, eliminates the need of camera motion compensation and enables reliable and computationally efficient fatigue crack detection using the nonstationary AR headset. In addition, an AR environment is created and integrated with the computer vision algorithm. The crack detection results are transmitted to the AR headset worn by the bridge inspector, where they are converted into holograms and anchored on the bridge surface in the 3D real-world environment. The AR environment also provides virtual menus to support human-in-the-loop decision-making to determine optimal crack detection parameters. This human-centered approach with improved visualization and human–machine collaboration aids the inspector in making well-informed decisions in the field in a near-real-time fashion. The proposed crack detection method is comprehensively assessed using two laboratory test setups for both in-plane and out-of-plane fatigue cracks. Finally, using the integrated AR environment, a human-centered bridge inspection is conducted to demonstrate the efficacy and potential of the proposed methodology.


  • Open Access

    Wind-Induced Vibration Monitoring of High-Mast Illumination Poles Using Wireless Smart Sensors

    by Mona Shaheen, Jian Li, Caroline Bennett, William Collins

    This paper describes the use of wireless smart sensors for examining the underlying mechanism for the wind-induced vibration of high-mast illumination pole (HMIP) structures. HMIPs are tall, slender structures with low inherent damping. Video recordings of multiple HMIPs showed considerable vibrations of these HMIPs under wind loading in the state of Kansas. The HMIPs experienced cyclic large-amplitude displacements at the top, which can produce high-stress demand and lead to fatigue cracking at the bottom of the pole. In this study, the natural frequencies of the HMIP were assessed using pluck tests and finite element modeling, and the recorded vibration frequencies were obtained through computer vision-based video analysis. Meanwhile, a 30.48 m tall HMIP with three LED luminaires made of galvanized steel located in Wakeeney, Kansas, was selected for long-term vibration monitoring using wireless smart sensors to investigate the underlying mechanism for the excessive wind-induced vibrations. Data analysis with the long-term monitoring data indicates that while vortex-induced vibration occurs frequently at relatively low amplitude, buffeting-induced vibration was the leading cause of the excessive vibrations of the monitored HMIP. The findings provide crucial information to guide the design of vibration mitigation strategies for these HMIP structures.


  • Statistical Analysis of Master Curve Sampling, Screening, and Weighting Methodologies

    by Tristan Yount, William Collins, Sebastian Lindqvist, Kim Wallin

    The master curve methodology is used to define the scatter and temperature dependence of ferritic steel fracture toughness in the ductile-to-brittle transition region, described by a single parameter, the reference temperature, To. The primary objectives of this study are to investigate the effect that different processes have on bias and precision of the reference temperature estimation, as well as the effect on the required dataset size. Analyses were performed through Monte Carlo simulations using a synthetic dataset consisting of 17,600 artificial single-edge bend KJc values censored by applicable specimen capacity limits. Reference temperature assessments were performed using both multi- and single-temperature analyses, and the effects of temperature selection, data validity weighting factors, and material homogeneity screening processes were evaluated. Multi-temperature analyses were based on a selected initial test temperature, with data sampled from subsequent temperatures based on provisionally calculated To values. The obtained reference temperature values are normally distributed with the average value remaining relatively constant regardless of test temperature. Standard deviations of reference temperatures were also relatively constant when evaluating data from test temperatures within ± 50°C (± 90°F) of the final calculated To, exhibiting less variability than predicted by the current specification. When sampling data are more than 50°C (90°F) below To, however, larger datasets are needed to obtain similar levels of precision. Guidance is provided for the modification of weighting factors to incorporate multiple confidence intervals into the validation procedure. Finally, recommendations are given on the assessment of an anomaly caused by all KJc data lying above the median master curve.


  • Open Access

    Dynamic Fracture and Crack Arrest Toughness Evaluation of High-Performance Steel Used in Highway Bridges

    by William N. Collins, Tristan D. Yount, Ryan J. Sherman, Roberto T. Leon, Robert J. Connor

    Impact energy tests are an efficient method of verifying adequate toughness of steel prior to it being put into service. Based on a multitude of historical correlations between impact energy and fracture toughness, minimum impact energy requirements that correspond to desired levels of fracture toughness are prescribed by steel bridge design specifications. Research characterizing the fracture behavior of grade 485 and 690 (70 and 100) high-performance steel utilized impact, fracture toughness, and crack arrest testing to verify adequate performance for bridge applications. Fracture toughness results from both quasi-static and dynamic stress intensity rate tests were analyzed using the most recently adopted master curve methodology. Both impact and fracture toughness tests indicated performance significantly greater than the minimum required by material specifications. Even at the AASHTO Zone III service temperature, which is significantly colder than prescribed test temperatures, minimum average impact energy requirements were greatly exceeded. All master curve reference temperatures, both for quasi-static and dynamic loading rates, were found to be colder than the Zone III minimum service temperature. Three correlations between impact energy and fracture toughness were evaluated and found to estimate reference temperatures that are conservative by 12 to 50 °C (22 to 90 °F) on average for the grades and specimen types tested. The evaluation of two reference temperature shifts intended to account for the loading rate was also performed and the results are discussed.