Anders Ågren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anders Ågren has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Fredrik Ljunggren
4 shared publications- Fredrik Ljunggren
Luleå University of Technology, Luleå, Sweden
4 shared publications Grover Zurita Villarroel
3 shared publications- Esbjörn Pettersson
SP Energy Technology Center AB, Box 726, 941 28 Piteå, Sweden
2 shared publications Manfred Klopotek
Lueå University of Technology
2 shared publicationsÖ. Johansson
Luleå University of Technology
2 shared publications
Latest Publications
- 9 May 2014
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 07 (1) , 413-422
The Influence of the Acoustic Transfer Functions on the Estimated Interior Noise from an Electric Rear Axle Drive
In the vehicle development process, targets are defined to fulfill customers' expectations on acoustic comfort. The interior complete vehicle acoustic targets can be cascaded down to system and component targets, e.g. insulation properties and source strengths. The acoustic transfer functions (ATFs) from components radiating airborne noise play a central role for the interior sound pressure levels. For hybrid vehicles fitted with an electric traction motor, the contribution of high frequency tonal components radiated from the motor housing needs to be controlled. The interior sound pressure due to an airborne motor order can be estimated by surface velocities and ATFs. This study addresses the ATFs measured from a large number of positions located around an electric rear axle drive (ERAD) and their influence on estimated interior noise. First, the magnitude variation between the individual ATFs and how it clearly can be visualized was presented. Displaying all ATFs in a color map revealed the magnitude at each geometrical location of the respective microphone. Secondly, the influence of the ATF's spatial resolution on estimated interior sound pressure was investigated. This was done for theoretical models of the stator shell source shape and also for measured surface velocities. By reducing the spatial resolution from 0.05 to 0.10 m between each microphone, the difference in noise contribution is typically within three decibels with a 12th octave smoothing filter applied to the narrow-band data. The findings from this work provide insight in the risks of compromising with the number of ATF's needed for contribution analysis.
- 9 May 2014
- Published by SAE International in SAE International Journal of Passenger Cars - Mechanical Systems
- Vol. 07 (1) , 413-422
The Influence of the Acoustic Transfer Functions on the Estimated Interior Noise from an Electric Rear Axle Drive
In the vehicle development process, targets are defined to fulfill customers' expectations on acoustic comfort. The interior complete vehicle acoustic targets can be cascaded down to system and component targets, e.g. insulation properties and source strengths. The acoustic transfer functions (ATFs) from components radiating airborne noise play a central role for the interior sound pressure levels. For hybrid vehicles fitted with an electric traction motor, the contribution of high frequency tonal components radiated from the motor housing needs to be controlled. The interior sound pressure due to an airborne motor order can be estimated by surface velocities and ATFs. This study addresses the ATFs measured from a large number of positions located around an electric rear axle drive (ERAD) and their influence on estimated interior noise. First, the magnitude variation between the individual ATFs and how it clearly can be visualized was presented. Displaying all ATFs in a color map revealed the magnitude at each geometrical location of the respective microphone. Secondly, the influence of the ATF's spatial resolution on estimated interior sound pressure was investigated. This was done for theoretical models of the stator shell source shape and also for measured surface velocities. By reducing the spatial resolution from 0.05 to 0.10 m between each microphone, the difference in noise contribution is typically within three decibels with a 12th octave smoothing filter applied to the narrow-band data. The findings from this work provide insight in the risks of compromising with the number of ATF's needed for contribution analysis.
- 1 September 2013
- Published by Portico in Noise Notes
- Vol. 12 (3) , 3-18
Elastic Layers to Reduce Sound Transmission in Lightweight Buildings
- 1 September 2013
- Published by Portico in Noise Notes
- Vol. 12 (3) , 3-18
Elastic Layers to Reduce Sound Transmission in Lightweight Buildings
- 1 April 2013
- Published by Taylor & Francis in Scandinavian Journal of Forest Research
- Vol. 28 (3) , 257-265
Predicting the green density as a means to achieve the volume of Norway spruce
All roundwood that arrives at pulp mills in Sweden is measured manually to obtain the volume. Shortened times between the harvest of the wood and its transportation to the mill have decreased the variation in the green density of wood and have increased the appeal of a method that combines the prediction of green density and weight scaling of the trucks with wood to obtain the volume. The aim of this article is to create a statistical model that can predict the green density of Norway spruce (Picea abies (L.) Karst.) pulpwood with the help of density data from earlier years for a certain mill and meteorological data from the wood supply area of the mill. To create the model to predict the green density, stepwise regression was used. The results showed that the model can explain the variation in green density by 89%, and can predict the density with a mean error of 0–0.019 ton/m3. The average standard deviation of the ratio between the measured observations and the predicted density was 7% on a yearly basis with variations over the year. From October to March, the model showed results that were at the same level to the result for the volume measurement performed in Sweden today.
- 1 April 2013
- Published by Taylor & Francis in Scandinavian Journal of Forest Research
- Vol. 28 (3) , 257-265
Predicting the green density as a means to achieve the volume of Norway spruce
All roundwood that arrives at pulp mills in Sweden is measured manually to obtain the volume. Shortened times between the harvest of the wood and its transportation to the mill have decreased the variation in the green density of wood and have increased the appeal of a method that combines the prediction of green density and weight scaling of the trucks with wood to obtain the volume. The aim of this article is to create a statistical model that can predict the green density of Norway spruce (Picea abies (L.) Karst.) pulpwood with the help of density data from earlier years for a certain mill and meteorological data from the wood supply area of the mill. To create the model to predict the green density, stepwise regression was used. The results showed that the model can explain the variation in green density by 89%, and can predict the density with a mean error of 0–0.019 ton/m3. The average standard deviation of the ratio between the measured observations and the predicted density was 7% on a yearly basis with variations over the year. From October to March, the model showed results that were at the same level to the result for the volume measurement performed in Sweden today.
- 1 March 2013
- Published by SAGE Publications in Building Acoustics
- Vol. 20 (1) , 25-42
Elastic Layers to Reduce Sound Transmission in Lightweight Buildings
To obtain satisfactory sound insulation is a challenging task when designing lightweight buildings. Poor performance at low frequencies as well as severe flanking transmission has traditionally often been more pronounced compared to heavier constructions. In the present casestudy based paper, various aspects of using elastic layers to improve sound insulation in lightweight buildings are considered. The effect on impact and airborne sound insulation by using two different kinds of vibration insulators between floor plans was examined together with the effect of using glues of various degree of elasticity in the construction. In situ measurements were performed inside a four-storey wooden frame based residential building and statistically significant variations in sound insulation were found. The efficiency of the two vibration insulators was further evaluated by vibration reduction measurements over the junctions. The difference in vibration reduction was found to be nearly constant in the frequency range 50–1000 Hz while the improvement of impact sound insulation increased by frequency. A long term test of elastic glues was also conducted, during three years, for stability over time. The best glues preserved a significantly higher damping ratio over time compared to the main part of the glues.
- 1 March 2013
- Published by SAGE Publications in Building Acoustics
- Vol. 20 (1) , 25-42
Elastic Layers to Reduce Sound Transmission in Lightweight Buildings
To obtain satisfactory sound insulation is a challenging task when designing lightweight buildings. Poor performance at low frequencies as well as severe flanking transmission has traditionally often been more pronounced compared to heavier constructions. In the present casestudy based paper, various aspects of using elastic layers to improve sound insulation in lightweight buildings are considered. The effect on impact and airborne sound insulation by using two different kinds of vibration insulators between floor plans was examined together with the effect of using glues of various degree of elasticity in the construction. In situ measurements were performed inside a four-storey wooden frame based residential building and statistically significant variations in sound insulation were found. The efficiency of the two vibration insulators was further evaluated by vibration reduction measurements over the junctions. The difference in vibration reduction was found to be nearly constant in the frequency range 50–1000 Hz while the improvement of impact sound insulation increased by frequency. A long term test of elastic glues was also conducted, during three years, for stability over time. The best glues preserved a significantly higher damping ratio over time compared to the main part of the glues.
- 1 March 2011
- Published by Elsevier in Applied Acoustics
- Vol. 72 (4) , 231-240
Potential solutions to improved sound performance of volume based lightweight multi-storey timber buildings
- 1 March 2011
- Published by Elsevier in Applied Acoustics
- Vol. 72 (4) , 231-240
Potential solutions to improved sound performance of volume based lightweight multi-storey timber buildings
- 1 March 2011
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 97 (2) , 254-265
An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment
- 1 March 2011
- Published by European Acoustics Association in Acta Acustica united with Acustica
- Vol. 97 (2) , 254-265
An Improved Prediction Model for the Impact Sound Level of Lightweight Floors: Introducing Decoupled Floor-Ceiling and Beam-Plate Moment
- 1 June 2010
- Published by SAGE Publications in Building Acoustics
- Vol. 17 (2) , 91-103
Variations in Sound Insulation in Nominally Identical Prefabricated Lightweight Timber Constructions
Variations in sound insulation necessitate higher safety margins to the legal requirements, which results in higher production costs. Increased knowledge about variations leads to lowered costs and better sound quality. In-situ measurements of 30 nominally identical apartments of a lightweight timber construction were performed, to assess and quantify the variations in airborne sound reduction and impact sound pressure level. The construction is an industrially prefabricated system of complete volumes. Different sound insulation was found between floor numbers as the apartments on the highest floor achieved significantly better sound insulation. This difference was assumed to be due to the extra weight on lower floors affecting the elastic connections used to structurally connect the apartments. The variation between apartments on the same floor was therefore evaluated using the Root Mean Square Error, resulting in a standard deviation of 0,9 dB and 1,4 dB for the airborne and impact sound insulation, respectively. The measurement variance was subtracted from the total variance. The remaining, unexplainable, variation of 0,8 dB in airborne sound insulation can be attributed to workmanship.
- 1 June 2010
- Published by SAGE Publications in Building Acoustics
- Vol. 17 (2) , 91-103
Variations in Sound Insulation in Nominally Identical Prefabricated Lightweight Timber Constructions
Variations in sound insulation necessitate higher safety margins to the legal requirements, which results in higher production costs. Increased knowledge about variations leads to lowered costs and better sound quality. In-situ measurements of 30 nominally identical apartments of a lightweight timber construction were performed, to assess and quantify the variations in airborne sound reduction and impact sound pressure level. The construction is an industrially prefabricated system of complete volumes. Different sound insulation was found between floor numbers as the apartments on the highest floor achieved significantly better sound insulation. This difference was assumed to be due to the extra weight on lower floors affecting the elastic connections used to structurally connect the apartments. The variation between apartments on the same floor was therefore evaluated using the Root Mean Square Error, resulting in a standard deviation of 0,9 dB and 1,4 dB for the airborne and impact sound insulation, respectively. The measurement variance was subtracted from the total variance. The remaining, unexplainable, variation of 0,8 dB in airborne sound insulation can be attributed to workmanship.
- 1 February 2007
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 300 (1-2) , 13-24
Human vibration perception from single- and dual-frequency components
- 1 February 2007
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 300 (1-2) , 13-24
Human vibration perception from single- and dual-frequency components
- 1 December 2006
- Published by SAGE Publications in Building Acoustics
- Vol. 13 (4) , 255-272
Dynamic and Subjective Analysis of a Lightweight/Semi-Heavyweight Floor in a Laboratory
A lightweight steel framed floor was tested in a laboratory for eight configurations: continuous/lumped main support, support/unsupported free long sides and concrete/plasterboard as top. The dynamic properties were revealed by modal analysis and subjective evaluations in terms of body perception and perception of vibrating articles. The results showed that the tested parameter that affects the floor most was the top layer. The semi-heavy weight floor with concrete layer was in general judged to be of higher acceptance than the lightweight floor having plaster-boards on the top. Additionally, the lightweight floor was used in a series of experiments where the effect of modified support and the effect of adding line loads of various degree of mechanical connection were tested. This part aims to simulate how the dynamics of a floor stepwise might change going from a bare floor to a floor installed inside a real building. The results show that the line load, mass and stiffness influence the floor in terms of changed natural frequencies. Depending on where on the floor the loads are located, different modes were affected and, depending on how the loads were connected to the floor, the gained stiffness varied slightly.
- 1 December 2006
- Published by SAGE Publications in Building Acoustics
- Vol. 13 (4) , 255-272
Dynamic and Subjective Analysis of a Lightweight/Semi-Heavyweight Floor in a Laboratory
A lightweight steel framed floor was tested in a laboratory for eight configurations: continuous/lumped main support, support/unsupported free long sides and concrete/plasterboard as top. The dynamic properties were revealed by modal analysis and subjective evaluations in terms of body perception and perception of vibrating articles. The results showed that the tested parameter that affects the floor most was the top layer. The semi-heavy weight floor with concrete layer was in general judged to be of higher acceptance than the lightweight floor having plaster-boards on the top. Additionally, the lightweight floor was used in a series of experiments where the effect of modified support and the effect of adding line loads of various degree of mechanical connection were tested. This part aims to simulate how the dynamics of a floor stepwise might change going from a bare floor to a floor installed inside a real building. The results show that the line load, mass and stiffness influence the floor in terms of changed natural frequencies. Depending on where on the floor the loads are located, different modes were affected and, depending on how the loads were connected to the floor, the gained stiffness varied slightly.
- 1 January 2004
- Published by Institute of Noise Control Engineering (INCE) in Noise Control Engineering Journal
- Vol. 52 (4) , 154
Reconstruction of cylinder pressure through multivariate data analysis: For prediction of noise and exhaust emissions
- 1 January 2004
- Published by Institute of Noise Control Engineering (INCE) in Noise Control Engineering Journal
- Vol. 52 (4) , 154
Reconstruction of cylinder pressure through multivariate data analysis: For prediction of noise and exhaust emissions