Koen J. A. Martens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Koen J. A. Martens has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Johannes Hohlbein
Laboratory of Biophysics, Wageningen University & Research, Wageningen, Netherlands
13 shared publications - Ulrike Endesfelder
Institut für Mikrobiologie und Biotechnologie Rheinische Friedrich-Wilhelms-Universität, Bonn, Germany
4 shared publications - John P. M. van Duynhoven
Wageningen University & Research
3 shared publications Michiel Kleerebezem
Host-Microbe Interactomics Group, Animal Sciences, Wageningen University and Research, De Elst 1, 6708 WD, Wageningen, The Netherlands
3 shared publicationsSam P. B. van Beljouw
Laboratory of Biophysics, Wageningen University and Research, Stippeneng 4, 6708 WE, Wageningen, The Netherlands
3 shared publicationsSander Baas
Laboratory of Biophysics, Wageningen University and Research, Stippeneng 4, 6708 WE, Wageningen, The Netherlands
3 shared publications
Latest Publications
- Open Access
A novel expression system for imaging single-molecule fluorescence in Haloferax volcanii WR806 enables visualization of Cas1 involvement in UV-light associated DNA repair
Fluorescence microscopy has become an indispensable tool in biological research, offering powerful approaches to study protein dynamics and molecular biochemistry in vivo . Among archaea, Haloferax volcanii has emerged as a particularly well-suited model organism for imaging studies, with a growing toolkit of established fluorescent markers, plasmids, and promoter systems. Recent advances in single-molecule imaging techniques have created new opportunities through WR806, a carotenoid-free strain providing reduced autofluorescence background. However, existing plasmid-based expression systems in WR806 show critical limitations in protein expression control and challenges with protein aggregation. To address these limitations, we developed pUE001, a novel expression system specifically designed for WR806. This system achieves precise expression control by decoupling selection and induction through strategic implementation of the trpA selection marker. Through comprehensive characterization, we demonstrate that pUE001 provides superior control over protein expression compared to the previously established pTA962 system. It enables linear, titratable expression of diverse proteins — from the highly regulated CRISPR-Cas component Cas1 to the abundant structural protein FtsZ1 — while preventing protein aggregation that could compromise native cellular functions. Additionally, we performed a comprehensive analysis of WR806 to show that carotenoid depletion does not affect native cellular physiology. Finally, to demonstrate the system’s utility, we investigated the role of Cas1 in UV-induced DNA repair using single-particle tracking photoactivated localization microscopy (sptPALM). Our findings reveal significant, dose-dependent changes in Cas1 mobility following UV-light induced damage, providing evidence for its involvement in DNA repair processes and offering new insights into the expanding roles of CRISPR-Cas systems beyond adaptive immunity.
Open AccessA novel expression system for imaging single-molecule fluorescence in Haloferax volcanii WR806 enables visualization of Cas1 involvement in UV-light associated DNA repair
Fluorescence microscopy has become an indispensable tool in biological research, offering powerful approaches to study protein dynamics and molecular biochemistry in vivo . Among archaea, Haloferax volcanii has emerged as a particularly well-suited model organism for imaging studies, with a growing toolkit of established fluorescent markers, plasmids, and promoter systems. Recent advances in single-molecule imaging techniques have created new opportunities through WR806, a carotenoid-free strain providing reduced autofluorescence background. However, existing plasmid-based expression systems in WR806 show critical limitations in protein expression control and challenges with protein aggregation. To address these limitations, we developed pUE001, a novel expression system specifically designed for WR806. This system achieves precise expression control by decoupling selection and induction through strategic implementation of the trpA selection marker. Through comprehensive characterization, we demonstrate that pUE001 provides superior control over protein expression compared to the previously established pTA962 system. It enables linear, titratable expression of diverse proteins — from the highly regulated CRISPR-Cas component Cas1 to the abundant structural protein FtsZ1 — while preventing protein aggregation that could compromise native cellular functions. Additionally, we performed a comprehensive analysis of WR806 to show that carotenoid depletion does not affect native cellular physiology. Finally, to demonstrate the system’s utility, we investigated the role of Cas1 in UV-induced DNA repair using single-particle tracking photoactivated localization microscopy (sptPALM). Our findings reveal significant, dose-dependent changes in Cas1 mobility following UV-light induced damage, providing evidence for its involvement in DNA repair processes and offering new insights into the expanding roles of CRISPR-Cas systems beyond adaptive immunity.
- Open Access
EVE is an open modular data analysis software for event-based localization microscopy
Event-based sensors (EBS), or neuromorphic vision sensors, offer a novel approach to imaging by recording light intensity changes asynchronously, unlike conventional cameras that capture light over fixed exposure times. This capability results in high temporal resolution, reduced data redundancy, and a wide dynamic range. This makes EBS ideal for Single-Molecule Localization Microscopy (SMLM) as SMLM relies on the sequential imaging of sparse, blinking fluorescent emitters to achieve super-resolution. Recent studies have shown that EBS can effectively capture these emitters, achieving spatial resolution comparable to traditional cameras. However, existing analyses of event-based SMLM (eveSMLM) data have relied on converting event lists into image frames for conventional analysis, limiting the full potential of the technology. To overcome this limitation, we developed EVE, a specialized software for analyzing eveSMLM data. EVE offers an integrated platform for detection, localization, and post-processing, with various algorithmic options tailored for the unique structure of eveSMLM data. EVE is user-friendly and features an open, modular infrastructure that supports ongoing development and optimization. EVE is the first dedicated tool for event-based SMLM, transforming the analysis process to fully utilize the spatiotemporal data generated by EBS. This allows researchers to explore the full potential of eveSMLM and encourages the development of new analytical methods and experimental improvements.
Open AccessEVE is an open modular data analysis software for event-based localization microscopy
Event-based sensors (EBS), or neuromorphic vision sensors, offer a novel approach to imaging by recording light intensity changes asynchronously, unlike conventional cameras that capture light over fixed exposure times. This capability results in high temporal resolution, reduced data redundancy, and a wide dynamic range. This makes EBS ideal for Single-Molecule Localization Microscopy (SMLM) as SMLM relies on the sequential imaging of sparse, blinking fluorescent emitters to achieve super-resolution. Recent studies have shown that EBS can effectively capture these emitters, achieving spatial resolution comparable to traditional cameras. However, existing analyses of event-based SMLM (eveSMLM) data have relied on converting event lists into image frames for conventional analysis, limiting the full potential of the technology. To overcome this limitation, we developed EVE, a specialized software for analyzing eveSMLM data. EVE offers an integrated platform for detection, localization, and post-processing, with various algorithmic options tailored for the unique structure of eveSMLM data. EVE is user-friendly and features an open, modular infrastructure that supports ongoing development and optimization. EVE is the first dedicated tool for event-based SMLM, transforming the analysis process to fully utilize the spatiotemporal data generated by EBS. This allows researchers to explore the full potential of eveSMLM and encourages the development of new analytical methods and experimental improvements.
- 15 January 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (6) , 1074-1081
Temporal analysis of relative distances (TARDIS) is a robust, parameter-free alternative to single-particle tracking
In single-particle tracking, individual particles are localized and tracked over time to probe their diffusion and molecular interactions. Temporal crossing of trajectories, blinking particles, and false-positive localizations present computational challenges that have remained difficult to overcome. Here we introduce a robust, parameter-free alternative to single-particle tracking: temporal analysis of relative distances (TARDIS). In TARDIS, an all-to-all distance analysis between localizations is performed with increasing temporal shifts. These pairwise distances represent either intraparticle distances originating from the same particle, or interparticle distances originating from unrelated particles, and are fitted analytically to obtain quantitative measures on particle dynamics. We showcase that TARDIS outperforms tracking algorithms, benchmarked on simulated and experimental data of varying complexity. We further show that TARDIS performs accurately in complex conditions characterized by high particle density, strong emitter blinking or false-positive localizations, and is in fact limited by the capabilities of localization algorithms. TARDIS’ robustness enables fivefold shorter measurements without loss of information.
- 15 January 2024
- Published by Springer Nature in Nature Methods
- Vol. 21 (6) , 1074-1081
Temporal analysis of relative distances (TARDIS) is a robust, parameter-free alternative to single-particle tracking
In single-particle tracking, individual particles are localized and tracked over time to probe their diffusion and molecular interactions. Temporal crossing of trajectories, blinking particles, and false-positive localizations present computational challenges that have remained difficult to overcome. Here we introduce a robust, parameter-free alternative to single-particle tracking: temporal analysis of relative distances (TARDIS). In TARDIS, an all-to-all distance analysis between localizations is performed with increasing temporal shifts. These pairwise distances represent either intraparticle distances originating from the same particle, or interparticle distances originating from unrelated particles, and are fitted analytically to obtain quantitative measures on particle dynamics. We showcase that TARDIS outperforms tracking algorithms, benchmarked on simulated and experimental data of varying complexity. We further show that TARDIS performs accurately in complex conditions characterized by high particle density, strong emitter blinking or false-positive localizations, and is in fact limited by the capabilities of localization algorithms. TARDIS’ robustness enables fivefold shorter measurements without loss of information.
- Open Access
Live-cell imaging reveals the trade-off between target search flexibility and efficiency for Cas9 and Cas12a
CRISPR-Cas systems have widely been adopted as genome editing tools, with two frequently employed Cas nucleases being Spy Cas9 and Lb Cas12a. Although both nucleases use RNA guides to find and cleave target DNA sites, the two enzymes differ in terms of protospacer-adjacent motif (PAM) requirements, guide architecture and cleavage mechanism. In the last years, rational engineering led to the creation of PAM-relaxed variants Sp RYCas9 and imp Lb Cas12a to broaden the targetable DNA space. By employing their catalytically inactive variants (dCas9/dCas12a), we quantified how the protein-specific characteristics impact the target search process. To allow quantification, we fused these nucleases to the photoactivatable fluorescent protein PAmCherry2.1 and performed single-particle tracking in cells of Escherichia coli . From our tracking analysis, we derived kinetic parameters for each nuclease with a non-targeting RNA guide, strongly suggesting that interrogation of DNA by Lb dCas12a variants proceeds faster than that of Spy dCas9. In the presence of a targeting RNA guide, both simulations and imaging of cells confirmed that Lb dCas12a variants are faster and more efficient in finding a specific target site. Our work demonstrates the trade-off of relaxing PAM requirements in Spy dCas9 and Lb dCas12a using a powerful framework, which can be applied to other nucleases to quantify their DNA target search.
Open AccessLive-cell imaging reveals the trade-off between target search flexibility and efficiency for Cas9 and Cas12a
CRISPR-Cas systems have widely been adopted as genome editing tools, with two frequently employed Cas nucleases being Spy Cas9 and Lb Cas12a. Although both nucleases use RNA guides to find and cleave target DNA sites, the two enzymes differ in terms of protospacer-adjacent motif (PAM) requirements, guide architecture and cleavage mechanism. In the last years, rational engineering led to the creation of PAM-relaxed variants Sp RYCas9 and imp Lb Cas12a to broaden the targetable DNA space. By employing their catalytically inactive variants (dCas9/dCas12a), we quantified how the protein-specific characteristics impact the target search process. To allow quantification, we fused these nucleases to the photoactivatable fluorescent protein PAmCherry2.1 and performed single-particle tracking in cells of Escherichia coli . From our tracking analysis, we derived kinetic parameters for each nuclease with a non-targeting RNA guide, strongly suggesting that interrogation of DNA by Lb dCas12a variants proceeds faster than that of Spy dCas9. In the presence of a targeting RNA guide, both simulations and imaging of cells confirmed that Lb dCas12a variants are faster and more efficient in finding a specific target site. Our work demonstrates the trade-off of relaxing PAM requirements in Spy dCas9 and Lb dCas12a using a powerful framework, which can be applied to other nucleases to quantify their DNA target search.
- Open Access
Temporal analysis of relative distances (TARDIS) is a robust, parameter-free alternative to single-particle tracking
In single-particle tracking (spt), individual particles are localized and tracked over time to probe their diffusion and molecular interactions. Temporal crossing of trajectories, blinking particles, and false-positive localizations present computational challenges that have remained difficult to overcome. Here, we introduce a robust, parameter-free alternative to spt: TARDIS. In TARDIS, an all-to-all distance analysis between localizations is performed with increasing temporal shifts. These pairwise distances fall in two categories: inter-particle distances not originating from the same particle, and intra-particle distances originating from the same particle. Since the distribution of inter-particle distances is unaffected by temporal shifts, the distribution of particle jump distances can be analytically fitted by analysing multiple temporal shifts. TARDIS outperforms existing tracking algorithms especially in complex conditions, and is even robust in scenarios that exceed the capabilities of current localization algorithms. Using TARDIS, we further show that measurements can be five-fold shorter without loss of information.
Open AccessTemporal analysis of relative distances (TARDIS) is a robust, parameter-free alternative to single-particle tracking
In single-particle tracking (spt), individual particles are localized and tracked over time to probe their diffusion and molecular interactions. Temporal crossing of trajectories, blinking particles, and false-positive localizations present computational challenges that have remained difficult to overcome. Here, we introduce a robust, parameter-free alternative to spt: TARDIS. In TARDIS, an all-to-all distance analysis between localizations is performed with increasing temporal shifts. These pairwise distances fall in two categories: inter-particle distances not originating from the same particle, and intra-particle distances originating from the same particle. Since the distribution of inter-particle distances is unaffected by temporal shifts, the distribution of particle jump distances can be analytically fitted by analysing multiple temporal shifts. TARDIS outperforms existing tracking algorithms especially in complex conditions, and is even robust in scenarios that exceed the capabilities of current localization algorithms. Using TARDIS, we further show that measurements can be five-fold shorter without loss of information.
- Open Access
- 21 October 2022
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (21) , 8618-8625
Enabling Spectrally Resolved Single-Molecule Localization Microscopy at High Emitter Densities
Single-molecule localization microscopy (SMLM) is a powerful super-resolution technique for elucidating structure and dynamics in the life- and material sciences. Simultaneously acquiring spectral information (spectrally resolved SMLM, sSMLM) has been hampered by several challenges: an increased complexity of the optical detection pathway, lower accessible emitter densities, and compromised spatio-spectral resolution. Here we present a single-component, low-cost implementation of sSMLM that addresses these challenges. Using a low-dispersion transmission grating positioned close to the image plane, the +1stdiffraction order is minimally elongated and is analyzed using existing single-molecule localization algorithms. The distance between the 0th and 1st order provides accurate information on the spectral properties of individual emitters. This method enables a 5-fold higher emitter density while discriminating between fluorophores whose peak emissions are less than 15 nm apart. Our approach can find widespread use in single-molecule applications that rely on distinguishing spectrally different fluorophores under low photon conditions.
- 21 October 2022
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (21) , 8618-8625
Open AccessEnabling Spectrally Resolved Single-Molecule Localization Microscopy at High Emitter Densities
Single-molecule localization microscopy (SMLM) is a powerful super-resolution technique for elucidating structure and dynamics in the life- and material sciences. Simultaneously acquiring spectral information (spectrally resolved SMLM, sSMLM) has been hampered by several challenges: an increased complexity of the optical detection pathway, lower accessible emitter densities, and compromised spatio-spectral resolution. Here we present a single-component, low-cost implementation of sSMLM that addresses these challenges. Using a low-dispersion transmission grating positioned close to the image plane, the +1stdiffraction order is minimally elongated and is analyzed using existing single-molecule localization algorithms. The distance between the 0th and 1st order provides accurate information on the spectral properties of individual emitters. This method enables a 5-fold higher emitter density while discriminating between fluorophores whose peak emissions are less than 15 nm apart. Our approach can find widespread use in single-molecule applications that rely on distinguishing spectrally different fluorophores under low photon conditions.
- Open Access
Enabling spectrally resolved single-molecule localization microscopy at high emitter densities
Single-molecule localization microscopy (SMLM) is a powerful technique for elucidating structure and dynamics in the life- and material sciences with sub-50 nm spatial resolution. The simultaneous acquisition of spectral information (spectrally resolved SMLM, sSMLM) enables multiplexing using spectrally distinct fluorophores or enable the probing of local chemical environments by using solvachromatic fluorophores such as Nile Red. Until now, the widespread utilisation of sSMLM was hampered by several challenges: an increased complexity of the optical detection pathway, limited software solutions for data analysis, lower accessible emitter densities or smaller field-of-views, and overall compromised spatio-spectral resolution. Here, we present a low-cost implementation of sSMLM that addresses these challenges. Using a blazed, low-dispersion transmission grating positioned close to the image plane here represented by the camera sensor, the +1 st diffraction order is minimally elongated compared to the point spread function of the 0 th order and can therefore be analysed using common subpixel single-molecule localization algorithms. The distance between both PSFs provides accurate information on the spectral properties of the emitter. The minimal excess width of 1 st order PSFs enables a fivefold higher emitter density compared to other sSMLM approaches whilst achieving a spatio-spectral localization accuracy sufficient to discriminate between fluorophores whose peak emission are less than 15 nm apart as demonstrated using dSTORM, DNA-PAINT and smFRET. We provide an ImageJ/Fiji plugin (sSMLMAnalyzer) and suitable Matlab scripts for data analysis. We envision that our approach will find widespread use in super-resolution applications that rely on distinguishing spectrally different fluorophores under low photon conditions.
Open AccessEnabling spectrally resolved single-molecule localization microscopy at high emitter densities
Single-molecule localization microscopy (SMLM) is a powerful technique for elucidating structure and dynamics in the life- and material sciences with sub-50 nm spatial resolution. The simultaneous acquisition of spectral information (spectrally resolved SMLM, sSMLM) enables multiplexing using spectrally distinct fluorophores or enable the probing of local chemical environments by using solvachromatic fluorophores such as Nile Red. Until now, the widespread utilisation of sSMLM was hampered by several challenges: an increased complexity of the optical detection pathway, limited software solutions for data analysis, lower accessible emitter densities or smaller field-of-views, and overall compromised spatio-spectral resolution. Here, we present a low-cost implementation of sSMLM that addresses these challenges. Using a blazed, low-dispersion transmission grating positioned close to the image plane here represented by the camera sensor, the +1 st diffraction order is minimally elongated compared to the point spread function of the 0 th order and can therefore be analysed using common subpixel single-molecule localization algorithms. The distance between both PSFs provides accurate information on the spectral properties of the emitter. The minimal excess width of 1 st order PSFs enables a fivefold higher emitter density compared to other sSMLM approaches whilst achieving a spatio-spectral localization accuracy sufficient to discriminate between fluorophores whose peak emission are less than 15 nm apart as demonstrated using dSTORM, DNA-PAINT and smFRET. We provide an ImageJ/Fiji plugin (sSMLMAnalyzer) and suitable Matlab scripts for data analysis. We envision that our approach will find widespread use in super-resolution applications that rely on distinguishing spectrally different fluorophores under low photon conditions.
- Open Access
- 28 April 2020
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 36 (20) , 5502-5509
Spatiotemporal Heterogeneity of κ-Carrageenan Gels Investigated via Single-Particle-Tracking Fluorescence Microscopy
Hydrogels made of the polysaccharide κ-carrageenan are widely used in the food and personal care industry as thickeners or gelling agents. These hydrogels feature dense regions embedded in a coarser bulk network, but the characteristic size and behavior of these regions has remained elusive. Here, we use single-particle-tracking fluorescence microscopy (sptFM) to quantitatively describe κ-carrageenan gels. Infusing fluorescent probes into fully gelated κ-carrageenan hydrogels resulted in two distinct diffusional behaviors. Obstructed self-diffusion of the probes revealed that the coarse network consists of κ-carrageenan strands with a typical diameter of 3.2 ± 0.3 nm leading to a nanoprobe diffusion coefficient of ~1-5∙10 12 m2/s. In the dense network regions, we found a fraction with a largely decreased diffusion coefficient of ~1∙10 13 m2/s. We also observed dynamic exchange between these states. The computation of spatial mobility maps from diffusional data indicated that the dense network regions have a characteristic diameter of ~1 µm and are itself mobile on the seconds-to-minutes timescale. sptFM provides an unprecedented view on spatiotemporal heterogeneity of hydrogel networks, which we believe bears general relevance for understanding transport and release of both low- and high molecular weight solutes.
- 28 April 2020
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 36 (20) , 5502-5509
Open AccessSpatiotemporal Heterogeneity of κ-Carrageenan Gels Investigated via Single-Particle-Tracking Fluorescence Microscopy
Hydrogels made of the polysaccharide κ-carrageenan are widely used in the food and personal care industry as thickeners or gelling agents. These hydrogels feature dense regions embedded in a coarser bulk network, but the characteristic size and behavior of these regions has remained elusive. Here, we use single-particle-tracking fluorescence microscopy (sptFM) to quantitatively describe κ-carrageenan gels. Infusing fluorescent probes into fully gelated κ-carrageenan hydrogels resulted in two distinct diffusional behaviors. Obstructed self-diffusion of the probes revealed that the coarse network consists of κ-carrageenan strands with a typical diameter of 3.2 ± 0.3 nm leading to a nanoprobe diffusion coefficient of ~1-5∙10 12 m2/s. In the dense network regions, we found a fraction with a largely decreased diffusion coefficient of ~1∙10 13 m2/s. We also observed dynamic exchange between these states. The computation of spatial mobility maps from diffusional data indicated that the dense network regions have a characteristic diameter of ~1 µm and are itself mobile on the seconds-to-minutes timescale. sptFM provides an unprecedented view on spatiotemporal heterogeneity of hydrogel networks, which we believe bears general relevance for understanding transport and release of both low- and high molecular weight solutes.
- Open Access
Analyzing engineered point spread functions using phasor-based single-molecule localization microscopy
The point spread function (PSF) of single molecule emitters can be engineered in the Fourier plane to encode three-dimensional localization information, creating double-helix, saddle-point or tetra-pod PSFs. Here, we describe and assess adaptations of the phasor-based single-molecule localization microscopy (pSMLM) algorithm to localize single molecules using these PSFs with sub-pixel accuracy. For double-helix, pSMLM identifies the two individual lobes and uses their relative rotation for obtaining z -resolved localizations, while for saddle-point or tetra-pod, a novel phasor-based deconvolution approach is used. The pSMLM software package delivers similar precision and recall rates to the best-in-class software package (SMAP) at signal-to-noise ratios typical for organic fluorophores. pSMLM substantially improves the localization rate by a factor of 2 - 4x on a standard CPU, with 1-1.5·10 4 (double-helix) or 2.5·10 5 (saddle-point/tetra-pod) localizations/second.
Open AccessAnalyzing engineered point spread functions using phasor-based single-molecule localization microscopy
The point spread function (PSF) of single molecule emitters can be engineered in the Fourier plane to encode three-dimensional localization information, creating double-helix, saddle-point or tetra-pod PSFs. Here, we describe and assess adaptations of the phasor-based single-molecule localization microscopy (pSMLM) algorithm to localize single molecules using these PSFs with sub-pixel accuracy. For double-helix, pSMLM identifies the two individual lobes and uses their relative rotation for obtaining z -resolved localizations, while for saddle-point or tetra-pod, a novel phasor-based deconvolution approach is used. The pSMLM software package delivers similar precision and recall rates to the best-in-class software package (SMAP) at signal-to-noise ratios typical for organic fluorophores. pSMLM substantially improves the localization rate by a factor of 2 - 4x on a standard CPU, with 1-1.5·10 4 (double-helix) or 2.5·10 5 (saddle-point/tetra-pod) localizations/second.