Onur Polat
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Onur Polat has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Doğan
Department of Ophthalmology, Faculty of Medicine, Afyonkarahisar Health Sciences University, Afyonkarahisar, Türkiye
4 shared publications Sibel Inan
Afyonkarahisar Health Sciences University, Faculty of Medicine, Ophthalmology Department, Afyonkarahisar, Turkey
4 shared publications- Tuncay Küsbeci
Department of Ophthalmology, Izmir City Hospital, Izmir, Turkey
4 shared publications Umit Ubeyt Inan
Afyonkarahisar Parkhayat Hospital, Ophthalmology Clinic, Afyonkarahisar,Turkey
4 shared publicationsGuliz Fatma Yavas
Department of Ophthalmology, Afyon Kocatepe University Faculty of Medicine, Afyonkarahisar, Turkey
2 shared publicationsGüliz Fatma Yavaş
Hacettepe University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey
2 shared publications
Latest Publications
- Open Access
- 1 January 2022
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 86 (6)
Comparison of sweep visual evoked potential of visual acuity and Snellen visual acuity in healthy and amblyopic children
To evaluate the visual acuity of healthy and amblyopic children using sweep visual evoked potential and compare the results with those of Snellen visual acuity testing. A total of 160 children aged 6-17 years were included in the study. Of these, 104 (65%) were aged 7-17 years old, able to verbally communicate, and did not have any systemic or ocular pathology (Group 1). Group 2 included 56 (35%) children aged 6-17 years, able to verbally communicate, and had strabismus or anisometropic amblyopia whose best corrected visual acuity was between 0.1 and 0.8. All subjects underwent a detailed ophthalmological examination and sweep visual evoked potential measurement. Demographic characteristics, ocular findings, best corrected visual acuity, and sweep visual evoked potential results were recorded. In Group 1, the mean and maximum visual acuity values for sweep visual evoked potential were lower than the Snellen best corrected visual acuity (p<0.001, for both, respectively). Bland-Altman analysis revealed that in Group 1, the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.11 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.023 logMAR. In Group 2, the mean and maximum sweep visual evoked potential visual acuity were lower than the Snellen best corrected visual acuity (p<0.001 and p=0.009, respectively). Bland-Altman analysis revealed that the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.16 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.19 logMAR. Sweep visual evoked potential visual acuity measurements have comparable results with Snellen visual acuity measurements. This technique is an objective and reliable method for evaluating visual acuity in children.
- 1 January 2022
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 86 (6)
Open AccessComparison of sweep visual evoked potential of visual acuity and Snellen visual acuity in healthy and amblyopic children
To evaluate the visual acuity of healthy and amblyopic children using sweep visual evoked potential and compare the results with those of Snellen visual acuity testing. A total of 160 children aged 6-17 years were included in the study. Of these, 104 (65%) were aged 7-17 years old, able to verbally communicate, and did not have any systemic or ocular pathology (Group 1). Group 2 included 56 (35%) children aged 6-17 years, able to verbally communicate, and had strabismus or anisometropic amblyopia whose best corrected visual acuity was between 0.1 and 0.8. All subjects underwent a detailed ophthalmological examination and sweep visual evoked potential measurement. Demographic characteristics, ocular findings, best corrected visual acuity, and sweep visual evoked potential results were recorded. In Group 1, the mean and maximum visual acuity values for sweep visual evoked potential were lower than the Snellen best corrected visual acuity (p<0.001, for both, respectively). Bland-Altman analysis revealed that in Group 1, the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.11 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.023 logMAR. In Group 2, the mean and maximum sweep visual evoked potential visual acuity were lower than the Snellen best corrected visual acuity (p<0.001 and p=0.009, respectively). Bland-Altman analysis revealed that the distribution of the differences between the Snellen best corrected visual acuity and mean sweep visual evoked potential visual acuity was ±0.16 logMAR, and the distribution of the differences between the Snellen best corrected visual acuity and maximum sweep visual evoked potential visual acuity was ±0.19 logMAR. Sweep visual evoked potential visual acuity measurements have comparable results with Snellen visual acuity measurements. This technique is an objective and reliable method for evaluating visual acuity in children.
- 18 November 2019
- Published by Springer Nature in Lasers in Medical Science
- Vol. 35 (3) , 687-693
Comparison of navigated laser and conventional single-spot laser system for induced pain during panretinal photocoagulation
To compare the panretinal photocoagulation (PRP)–induced pain response between novel navigated laser (Navilas) and conventional single-spot laser. The eyes were randomly assigned to Navilas or conventional laser. Contralateral eyes underwent PRP with the other system with 30 min resting interval. Pulse duration was 100 ms in conventional laser and 30 ms or 100 ms in Navilas and power setting was enough to create gray-white light burn on both devices. Pain response was evaluated by verbal scale (VS) (0–4) and visual analog scale (VAS) (0–10) after each PRP application. The mean age of 70 patients (140 eyes) was 62.52 ± 9.49 years. Mean power and spot numbers for Navilas and conventional laser were 291.9 ± 85.3 mW vs 368.4 ± 72.0 mW, and 375.4 ± 108.4 vs 374.2 ± 105.0 (p < 0.001 and p = 0.53, respectively). Pain scores for Navilas and conventional laser were 1.19 ± 0.73 and 1.99 ± 0.84 for VS and 2.41 ± 1.65 and 4.74 ± 2.17 for VAS (p < 0.001 and p < 0.001). More comfortable PRP is achieved with Navilas system in comparison with conventional single-spot laser system. However, small number of patients treated with same pulse duration and different contact lenses used for two systems should be taken into consideration. Besides, we did not report comparative clinical efficiency of either laser system.
- 18 November 2019
- Published by Springer Nature in Lasers in Medical Science
- Vol. 35 (3) , 687-693
Comparison of navigated laser and conventional single-spot laser system for induced pain during panretinal photocoagulation
To compare the panretinal photocoagulation (PRP)–induced pain response between novel navigated laser (Navilas) and conventional single-spot laser. The eyes were randomly assigned to Navilas or conventional laser. Contralateral eyes underwent PRP with the other system with 30 min resting interval. Pulse duration was 100 ms in conventional laser and 30 ms or 100 ms in Navilas and power setting was enough to create gray-white light burn on both devices. Pain response was evaluated by verbal scale (VS) (0–4) and visual analog scale (VAS) (0–10) after each PRP application. The mean age of 70 patients (140 eyes) was 62.52 ± 9.49 years. Mean power and spot numbers for Navilas and conventional laser were 291.9 ± 85.3 mW vs 368.4 ± 72.0 mW, and 375.4 ± 108.4 vs 374.2 ± 105.0 (p < 0.001 and p = 0.53, respectively). Pain scores for Navilas and conventional laser were 1.19 ± 0.73 and 1.99 ± 0.84 for VS and 2.41 ± 1.65 and 4.74 ± 2.17 for VAS (p < 0.001 and p < 0.001). More comfortable PRP is achieved with Navilas system in comparison with conventional single-spot laser system. However, small number of patients treated with same pulse duration and different contact lenses used for two systems should be taken into consideration. Besides, we did not report comparative clinical efficiency of either laser system.
- 14 October 2019
- Published by Fundatia Universitara Sanabuna in Romanian Journal of Ophthalmology
- Vol. 63 (3) , 238-244
The association of exudation pattern with anatomical and functional outcomes in patients with Neovascular Age-Related Macular Degeneration
Objective. To evaluate the correlation between visual outcomes and fluid configuration observed on spectral-domain optical coherence tomography (SD-OCT) in patients with wet age-related macular degeneration (AMD). Methods. Sixty-five eyes of 53 patients with AMD who were administered intravitreal ranibizumab treatment with 12 months of follow-up were included in this retrospective study. Presence of intraretinal cystoid fluid (IRC) and pigment epithelial detachment (PED), thickness of subretinal fluid (SRF), central macular thickness (CMT), and central macular volume (CMV) were assessed. Results. Subretinal fluid was observed in 29 eyes (45%), IRC in 36 eyes (55%), and PED in 39 eyes (60%). Baseline and final best-corrected visual acuity (BCVA) were 0.69±0.4 and 0.60±0.4 logMAR in the IRC negative group and 1.17±0.5 and 0.97±0.5 logMAR in the IRC positive group. BCVA was lower in IRC positive group (baseline p=0.001 and final=0.003); however, marked improvement was detected in both groups. Anatomic improvement and increased visual acuity were observed in groups with and without PED, IRC, and SRF. An inverse correlation was detected between pre-treatment CMT, IRC and post-treatment IRC, and final BCVA. Conclusion. Significant visual and anatomic improvement was observed after one-year of ranibizumab treatment regardless of fluid configuration. However, the presence of IRC was observed to be associated with worse visual acuity. Baseline retinal fluid configuration may have prognostic effects on functional success in patients treated with ranibizumab for wet AMD. Abbreviations. AMD = Age-related macular degeneration, VEGF = Vascular endothelial growth factor, IRC = intraretinal cystoid fluid, PED = pigment epithelial detachment, SRF = subretinal fluid, SD-OCT = spectral-domain ocular coherence tomography, IVR = intravitreal ranibizumab, BCVA = best-corrected visual acuity, FFA = fundus fluorescein angiography, CMT = central macular thickness, CMV = central macular volume.
- 14 October 2019
- Published by Fundatia Universitara Sanabuna in Romanian Journal of Ophthalmology
- Vol. 63 (3) , 238-244
The association of exudation pattern with anatomical and functional outcomes in patients with Neovascular Age-Related Macular Degeneration
Objective. To evaluate the correlation between visual outcomes and fluid configuration observed on spectral-domain optical coherence tomography (SD-OCT) in patients with wet age-related macular degeneration (AMD). Methods. Sixty-five eyes of 53 patients with AMD who were administered intravitreal ranibizumab treatment with 12 months of follow-up were included in this retrospective study. Presence of intraretinal cystoid fluid (IRC) and pigment epithelial detachment (PED), thickness of subretinal fluid (SRF), central macular thickness (CMT), and central macular volume (CMV) were assessed. Results. Subretinal fluid was observed in 29 eyes (45%), IRC in 36 eyes (55%), and PED in 39 eyes (60%). Baseline and final best-corrected visual acuity (BCVA) were 0.69±0.4 and 0.60±0.4 logMAR in the IRC negative group and 1.17±0.5 and 0.97±0.5 logMAR in the IRC positive group. BCVA was lower in IRC positive group (baseline p=0.001 and final=0.003); however, marked improvement was detected in both groups. Anatomic improvement and increased visual acuity were observed in groups with and without PED, IRC, and SRF. An inverse correlation was detected between pre-treatment CMT, IRC and post-treatment IRC, and final BCVA. Conclusion. Significant visual and anatomic improvement was observed after one-year of ranibizumab treatment regardless of fluid configuration. However, the presence of IRC was observed to be associated with worse visual acuity. Baseline retinal fluid configuration may have prognostic effects on functional success in patients treated with ranibizumab for wet AMD. Abbreviations. AMD = Age-related macular degeneration, VEGF = Vascular endothelial growth factor, IRC = intraretinal cystoid fluid, PED = pigment epithelial detachment, SRF = subretinal fluid, SD-OCT = spectral-domain ocular coherence tomography, IVR = intravitreal ranibizumab, BCVA = best-corrected visual acuity, FFA = fundus fluorescein angiography, CMT = central macular thickness, CMV = central macular volume.
- 20 March 2019
- Published by Fundatia Universitara Sanabuna in Romanian Journal of Ophthalmology
- Vol. 63 (1) , 86-90
Bilateral serous retinal detachment accompanied by a rare intraretinal fluid configuration in preeclampsia and PRES Syndrome
Purpose: To present the association between posterior reversible encephalopathy (PRES) syndrome due to preeclampsia and bilateral serous retinal detachment (SRD) accompanied by intraretinal fluid configuration. Methods: A 24-year-old woman, at 28 weeks of gestation presented with blurred vision bilaterally related to bilateral SRD involving the center of the macula accompanied by intraretinal fluid. The patient was diagnosed as pre-eclampsia accompanied by PRES syndrome. The patient approved and underwent delivery the same day. On day 9, ophthalmologic examination revealed complete resolution of SRD and normal visual acuity bilaterally and cranial MRI showed complete resolution of the vasogenic edema with medical treatment. Conclusion: SRD and accompanying retinal edema must be considered among etiological factors leading to sudden vision loss in patients with preeclampsia and PRES syndrome. Abbreviations: PRES = Posterior reversible encephalopathy, SRD = Serous retinal detachment, SD-OCT = Spectral-domain optical coherence tomography, RPE = Retinal pigment epithelium, CSC = Central serous chorioretinopathy, ONL = Outer nuclear layer, INL = Inner nuclear layer, IPL = Inner plexiform layer, RNFL = retinal nerve fiber layer.
- 20 March 2019
- Published by Fundatia Universitara Sanabuna in Romanian Journal of Ophthalmology
- Vol. 63 (1) , 86-90
Bilateral serous retinal detachment accompanied by a rare intraretinal fluid configuration in preeclampsia and PRES Syndrome
Purpose: To present the association between posterior reversible encephalopathy (PRES) syndrome due to preeclampsia and bilateral serous retinal detachment (SRD) accompanied by intraretinal fluid configuration. Methods: A 24-year-old woman, at 28 weeks of gestation presented with blurred vision bilaterally related to bilateral SRD involving the center of the macula accompanied by intraretinal fluid. The patient was diagnosed as pre-eclampsia accompanied by PRES syndrome. The patient approved and underwent delivery the same day. On day 9, ophthalmologic examination revealed complete resolution of SRD and normal visual acuity bilaterally and cranial MRI showed complete resolution of the vasogenic edema with medical treatment. Conclusion: SRD and accompanying retinal edema must be considered among etiological factors leading to sudden vision loss in patients with preeclampsia and PRES syndrome. Abbreviations: PRES = Posterior reversible encephalopathy, SRD = Serous retinal detachment, SD-OCT = Spectral-domain optical coherence tomography, RPE = Retinal pigment epithelium, CSC = Central serous chorioretinopathy, ONL = Outer nuclear layer, INL = Inner nuclear layer, IPL = Inner plexiform layer, RNFL = retinal nerve fiber layer.
- Open Access
- 29 November 2018
- Published by African Journals Online (AJOL) in African Health Sciences
- Vol. 18 (4) , 1010-1017
PASCAL laser platform produces less pain responses compared to conventional laser system during the panretinal photocoagulation: a randomized clinical trial
PASCAL laser platform produces less pain responses compared to conventional laser system during the panretinal photocoagulation: a randomized clinical trial
- 29 November 2018
- Published by African Journals Online (AJOL) in African Health Sciences
- Vol. 18 (4) , 1010-1017
Open AccessPASCAL laser platform produces less pain responses compared to conventional laser system during the panretinal photocoagulation: a randomized clinical trial
PASCAL laser platform produces less pain responses compared to conventional laser system during the panretinal photocoagulation: a randomized clinical trial
- Open Access
- 9 August 2017
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 47 (4) , 205-210
Factors Affecting Compliance to Intravitreal Anti-Vascular Endothelial Growth Factor Therapy in Patients with Age-Related Macular Degeneration
To determine factors influencing compliance in patients with neovascular age-related macular degeneration (n-AMD) undergoing intravitreal anti-vascular endothelial growth factor (VEGF) therapy. The files of n-AMD patients recommended treatment with ranibizumab were reviewed retrospectively. The treatment regimen was 3 consecutive monthly injections followed by monthly follow-up with intravitreal injections as needed (pro re nata, PRN). Demographic and ocular characteristics were recorded. The patients were categorized into 2 groups: full compliance to treatment, or incomplete loading schedule and/or irregular maintenance treatment. All patients were interviewed by phone about factors affecting continuation of treatment. Mean age of the 314 patients (160 female, 154 male) included in the study was 71.6±9.1 years. A total of 246 patients (78.3%) could complete 3 consecutive injections at 1-month intervals after the start of treatment; 57 patients (18.2%) did not attend monthly follow-up during the 1-year follow-up period following the 3 consecutive monthly injections. Overall, 39.8% of the patients were not able to fully comply with the ranibizumab treatment by PRN regimen for 1 year. Better visual acuity at baseline, smaller lesion size, living closer to the hospital, higher education and sociocultural level, and better financial status were determined as factors affecting patient compliance. The most frequent reasons to discontinue treatment were fear of injection, disbelief in the benefit of the treatment, financial limitations, continuation of treatment at another center, and comorbid systemic diseases. Patient compliance and success rates of anti-VEGF therapy may be increased by determining the factors affecting patient compliance and raising awareness about n-AMD among patients and their relatives.
- 9 August 2017
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 47 (4) , 205-210
Open AccessFactors Affecting Compliance to Intravitreal Anti-Vascular Endothelial Growth Factor Therapy in Patients with Age-Related Macular Degeneration
To determine factors influencing compliance in patients with neovascular age-related macular degeneration (n-AMD) undergoing intravitreal anti-vascular endothelial growth factor (VEGF) therapy. The files of n-AMD patients recommended treatment with ranibizumab were reviewed retrospectively. The treatment regimen was 3 consecutive monthly injections followed by monthly follow-up with intravitreal injections as needed (pro re nata, PRN). Demographic and ocular characteristics were recorded. The patients were categorized into 2 groups: full compliance to treatment, or incomplete loading schedule and/or irregular maintenance treatment. All patients were interviewed by phone about factors affecting continuation of treatment. Mean age of the 314 patients (160 female, 154 male) included in the study was 71.6±9.1 years. A total of 246 patients (78.3%) could complete 3 consecutive injections at 1-month intervals after the start of treatment; 57 patients (18.2%) did not attend monthly follow-up during the 1-year follow-up period following the 3 consecutive monthly injections. Overall, 39.8% of the patients were not able to fully comply with the ranibizumab treatment by PRN regimen for 1 year. Better visual acuity at baseline, smaller lesion size, living closer to the hospital, higher education and sociocultural level, and better financial status were determined as factors affecting patient compliance. The most frequent reasons to discontinue treatment were fear of injection, disbelief in the benefit of the treatment, financial limitations, continuation of treatment at another center, and comorbid systemic diseases. Patient compliance and success rates of anti-VEGF therapy may be increased by determining the factors affecting patient compliance and raising awareness about n-AMD among patients and their relatives.
- 15 July 2017
- Published by Acta Medica Alanya in Acta Medica Alanya
- Vol. 1 (2) , 67-71
Edinsel Nazolakrimal Kanal Tıkanıklığı Olan Olgularda Eksternal Dakriosistorinostomi Ve Transkanalikuler Multidiod Lazer Dakriosistorinostomi Sonuçlarının Karşılaştırılması
Amaç: Edinsel nazolakrimal kanal tıkanıklığı olan olgularda eksternal dakriyosistorinostomi(DSR) ve transkanalikuler multidiod lazer dakriyosistorinostomi(TK-DSR) sonuçlarının karşılaştırılması.Yöntemler: Edinsel nazolakrimal kanal tıkanıklığı tanısı konulan ve opere edilen hastaların verileri retrospektif olarak tarandı. 47 hastanın 49 gözüne yapılan eksternal DSR ameliyatları ile 34 hastanın 35 gözüne yapılan TK-DSR ameliyatlarının sonuçları karşılaştırıldı. Hastaların nazolakrimal pasaj açıklığı postoperatif 10. gün, 1, 3, 6 ve 12.aylarda kontrol edildi. Bulgular: Çalışmamızda 12. ayda saptanan cerrahi başarı oranı TK-DSR olgularında % 65,3, eksternal DSR olgularında % 86,1 idi. Ortalama ameliyat süresi eksternal DSR grubunda 53,02±5,04 dakika, TK- DSR grubunda 22,62±3,72 dakikaydı. TK- DSR grubunda 6 hastada (%17.1) nasal sineşi, 2 hastada (%5.7) konka yanığı, 1 hastada (%2.8) kanalikül oklüzyonu komplikasyon olarak görülürken, eksternal DSR grubunda 16 hastada (%32.6) kanama, 2 hastada (%4.1) cilde fistül gelişti. Sonuç: TK- DSR operasyon süresinin kısalığı, kanamanın daha az olması, cilt insizyonuna gerek kalmaması ve lakrimal pompa sisteminin daha az zarar görmesi gibi avantajları olmasına karşın cerrahi başarı oranları eksternal DSR’de daha yüksek görünmektedir. Cerrahi teknik üstünlükleri ve başarı oranları göz önünde bulundurularak uygun hastalarda uygun cerrahi teknik uygulanmalıdır.
- 15 July 2017
- Published by Acta Medica Alanya in Acta Medica Alanya
- Vol. 1 (2) , 67-71
Edinsel Nazolakrimal Kanal Tıkanıklığı Olan Olgularda Eksternal Dakriosistorinostomi Ve Transkanalikuler Multidiod Lazer Dakriosistorinostomi Sonuçlarının Karşılaştırılması
Amaç: Edinsel nazolakrimal kanal tıkanıklığı olan olgularda eksternal dakriyosistorinostomi(DSR) ve transkanalikuler multidiod lazer dakriyosistorinostomi(TK-DSR) sonuçlarının karşılaştırılması.Yöntemler: Edinsel nazolakrimal kanal tıkanıklığı tanısı konulan ve opere edilen hastaların verileri retrospektif olarak tarandı. 47 hastanın 49 gözüne yapılan eksternal DSR ameliyatları ile 34 hastanın 35 gözüne yapılan TK-DSR ameliyatlarının sonuçları karşılaştırıldı. Hastaların nazolakrimal pasaj açıklığı postoperatif 10. gün, 1, 3, 6 ve 12.aylarda kontrol edildi. Bulgular: Çalışmamızda 12. ayda saptanan cerrahi başarı oranı TK-DSR olgularında % 65,3, eksternal DSR olgularında % 86,1 idi. Ortalama ameliyat süresi eksternal DSR grubunda 53,02±5,04 dakika, TK- DSR grubunda 22,62±3,72 dakikaydı. TK- DSR grubunda 6 hastada (%17.1) nasal sineşi, 2 hastada (%5.7) konka yanığı, 1 hastada (%2.8) kanalikül oklüzyonu komplikasyon olarak görülürken, eksternal DSR grubunda 16 hastada (%32.6) kanama, 2 hastada (%4.1) cilde fistül gelişti. Sonuç: TK- DSR operasyon süresinin kısalığı, kanamanın daha az olması, cilt insizyonuna gerek kalmaması ve lakrimal pompa sisteminin daha az zarar görmesi gibi avantajları olmasına karşın cerrahi başarı oranları eksternal DSR’de daha yüksek görünmektedir. Cerrahi teknik üstünlükleri ve başarı oranları göz önünde bulundurularak uygun hastalarda uygun cerrahi teknik uygulanmalıdır.
- Open Access
- 1 December 2016
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 46 (6) , 259-263
Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. Data obtained using the Aladdin and Sirius systems from 110 eyes of 59 subjects who had no health problems other than refractive errors were retrospectively evaluated. Anterior chamber depth (ACD), flat (K1) and steep (K2) keratometry readings, and white-to-white distance (WTW) measurements taken with both devices were noted. The mean age of the patients was 47.31±18.57 years (range, 25 to 79 years). Mean ACD was 3.35±0.4 mm using Aladdin and 3.42±0.44 mm using Sirius. Mean difference in ACD was 0.075 mm greater with Sirius than Aladdin (p<0.001). K1 measurement obtained by Aladdin was an average of 0.409 D higher (p<0.001). No statistically significant differences were detected between the two devices in respect to K2 and WTW measurements (p=0.18, p=0.85 respectively). Pearson correlation analysis showed high correlation between the two devices for all measurements (r=0.985, 0.895, 0.961 and 0.766 for ACD, K1, K2 and WTW respectively; p<0.001). Anterior segment parameters obtained by Aladdin optical biometer and Sirius anterior segment analysis system correlated well with each other and measurement differences between the devices were clinically negligible except for K1 values.
- 1 December 2016
- Published by Galenos Yayinevi in Turkish Journal of Ophthalmology
- Vol. 46 (6) , 259-263
Open AccessComparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. Data obtained using the Aladdin and Sirius systems from 110 eyes of 59 subjects who had no health problems other than refractive errors were retrospectively evaluated. Anterior chamber depth (ACD), flat (K1) and steep (K2) keratometry readings, and white-to-white distance (WTW) measurements taken with both devices were noted. The mean age of the patients was 47.31±18.57 years (range, 25 to 79 years). Mean ACD was 3.35±0.4 mm using Aladdin and 3.42±0.44 mm using Sirius. Mean difference in ACD was 0.075 mm greater with Sirius than Aladdin (p<0.001). K1 measurement obtained by Aladdin was an average of 0.409 D higher (p<0.001). No statistically significant differences were detected between the two devices in respect to K2 and WTW measurements (p=0.18, p=0.85 respectively). Pearson correlation analysis showed high correlation between the two devices for all measurements (r=0.985, 0.895, 0.961 and 0.766 for ACD, K1, K2 and WTW respectively; p<0.001). Anterior segment parameters obtained by Aladdin optical biometer and Sirius anterior segment analysis system correlated well with each other and measurement differences between the devices were clinically negligible except for K1 values.
- 1 January 2016
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Ophthalmology
- Vol. 25 (2) , 71-77
Evaluation of Visual Disability in Pediatric Patients Admitted to Health Committee
- 1 January 2016
- Published by Turkiye Klinikleri in Turkiye Klinikleri Journal of Ophthalmology
- Vol. 25 (2) , 71-77
Evaluation of Visual Disability in Pediatric Patients Admitted to Health Committee
- 10 October 2015
- Published by AVES YAYINCILIK A.Ş. in Balkan Medical Journal
- Vol. 32 (4) , 382-387
Neutrophil-to-Lymphocyte Ratio as a Marker in Patients with Non-arteritic Anterior Ischemic Optic Neuropathy
Non-arteritic anterior ischemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Although the precise cause of NAION remains elusive, the etiology of NAION is believed to be multifactorial.To evaluate the utility of neutrophil-to-lymphocyte ratio (NLR) as a simple and readily available prognostic factor for clinical disease activity in patients with NAION.Case-control study.Forty-five patients with the diagnosis of NAION and 50 age- and sex-matched controls with/without any systemic or ocular diseases except cataract were retrospectively enrolled in the study. Demographic characteristics and laboratory findings including complete blood count of all patients and control subjects were obtained from the electronic medical record. The neutrophil and lymphocyte counts were recorded and the NLR was calculated.White blood cell, neutrophil, NLR and platelet values of the NAION patients were significantly higher than those of the controls (p<0.001, p<0.001, p=0.004, p=0.037, respectively). Initial NLR values were negatively correlated with initial and the third month best corrected visual acuity levels in the study group. The optimum NLR cut-off point for NAION was 1.94.NLR could be considered as a new inflammatory marker for assessment of the severity of inflammation in NAION patients with its quick, cheap, easily measurable property with routine complete blood count analysis.
- 10 October 2015
- Published by AVES YAYINCILIK A.Ş. in Balkan Medical Journal
- Vol. 32 (4) , 382-387
Neutrophil-to-Lymphocyte Ratio as a Marker in Patients with Non-arteritic Anterior Ischemic Optic Neuropathy
Non-arteritic anterior ischemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Although the precise cause of NAION remains elusive, the etiology of NAION is believed to be multifactorial.To evaluate the utility of neutrophil-to-lymphocyte ratio (NLR) as a simple and readily available prognostic factor for clinical disease activity in patients with NAION.Case-control study.Forty-five patients with the diagnosis of NAION and 50 age- and sex-matched controls with/without any systemic or ocular diseases except cataract were retrospectively enrolled in the study. Demographic characteristics and laboratory findings including complete blood count of all patients and control subjects were obtained from the electronic medical record. The neutrophil and lymphocyte counts were recorded and the NLR was calculated.White blood cell, neutrophil, NLR and platelet values of the NAION patients were significantly higher than those of the controls (p<0.001, p<0.001, p=0.004, p=0.037, respectively). Initial NLR values were negatively correlated with initial and the third month best corrected visual acuity levels in the study group. The optimum NLR cut-off point for NAION was 1.94.NLR could be considered as a new inflammatory marker for assessment of the severity of inflammation in NAION patients with its quick, cheap, easily measurable property with routine complete blood count analysis.