Cristian Andrés Carreño Meneses
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cristian Andrés Carreño Meneses has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Pizano-Martinez
Engineering Division, Campus Irapuato-Salamanca (DICIS), University of Guanajuato, Carr. Salamanca-Valle de Santiago km 3.5 + 1.5 km, Com. Palo Blanco, Salamanca 36885, Mexico
2 shared publications - Jose Merced Lozano-Garcia
Engineering Division, Campus Irapuato-Salamanca (DICIS), University of Guanajuato, Carr. Salamanca-Valle de Santiago km 3.5 + 1.5 km, Com. Palo Blanco, Salamanca 36885, Mexico
2 shared publications - Luis Ramon Merchan-Villalba
Engineering Division, Campus Irapuato-Salamanca (DICIS), University of Guanajuato, Carr. Salamanca-Valle de Santiago km 3.5 + 1.5 km, Com. Palo Blanco, Salamanca 36885, Mexico
2 shared publications F.A. Godínez
Instituto de Ingeniería Universidad Nacional Autónoma de México, UNAM, C.U. Mexico City Mexico
1 shared publication- Hector Javier Estrada-Garcia
Department of Electrical Engineering, University of Guanajuato, Salamanca 36787, Mexico
1 shared publication - Jose Domingo Alvarez
Universidad de Almería
1 shared publication
Latest Publications
- Open Access
- 15 October 2020
- Published by MDPI AG in Mathematics
- Vol. 8 (10) , 1794
Linearly Decoupled Control of a Dynamic Voltage Restorer without Energy Storage
This paper presents the design of a decoupled linear control strategy for a Dynamic Voltage Restorer (DVR) that utilizes a Matrix Converter (MC) as its core element and obtains the compensation energy directly from the power system. This DVR is intended to cope with power quality problems present in supply system voltages such as balanced and unbalanced variations (sags and swells), and harmonic distortion. The dynamic model of the complete system that includes the Matrix Converter, the input filters and the electrical grid, is performed in the synchronous reference frame (), to have constant signals at the fundamental frequency, in order to design the proposed linear control strategy. The coupling in the components of the system output signals caused by the Park Transformation, is eliminated by a change of variable proposed for the controller design, giving rise to a decoupled linear control. In this way, the strategy developed makes it possible to establish an adequate transient response for the converter in terms of convergence speed and overshoot magnitude, in addition to ensuring closed-loop system stability under bounded operating conditions. Unlike other proposals that utilize complex modulation strategies to control the MC under adverse conditions at the input terminals, in this case, the ability to generate fully controllable output voltages, regardless of the condition of the input signals, is provided by the designed linear controller. This allows the development of a multifunctional compensator with a simple control that could be of easy implementation. In order to verify the performance of the control strategy developed, and the effectiveness of the proposed DVR to mitigate the power quality problems already mentioned, several case studies are presented. The operational capacity of the MC is demonstrated by the obtained simulation results, which clearly reveals the capability of the DVR to eliminate voltage swells up to 50% and sags less than 50%. The compensation limit reached for sags is 37%. In relation to compensation for unbalanced voltage variations, the DVR manages to reduce the voltage imbalance from 11.11% to 0.37%. Finally, with regard to the operation of the DVR as an active voltage filter, the compensator is capable of reducing a THD of 20% calculated on the supply voltage, to a value of 1.53% measured at the load terminals. In the last two cases, the DVR mitigates disturbances to a level below the criteria established in the IEEE standard for power quality. Results obtained from numerical simulations performed in MATLAB/Simulink serve to validate the proposal, given that for each condition analyzed, the MC had succesfully generated the adequate compensation voltages, thus corroborating the robustness and effectiveness of the control strategy developed in this proposal.- 15 October 2020
- Published by MDPI AG in Mathematics
- Vol. 8 (10) , 1794
Open AccessLinearly Decoupled Control of a Dynamic Voltage Restorer without Energy Storage
This paper presents the design of a decoupled linear control strategy for a Dynamic Voltage Restorer (DVR) that utilizes a Matrix Converter (MC) as its core element and obtains the compensation energy directly from the power system. This DVR is intended to cope with power quality problems present in supply system voltages such as balanced and unbalanced variations (sags and swells), and harmonic distortion. The dynamic model of the complete system that includes the Matrix Converter, the input filters and the electrical grid, is performed in the synchronous reference frame (), to have constant signals at the fundamental frequency, in order to design the proposed linear control strategy. The coupling in the components of the system output signals caused by the Park Transformation, is eliminated by a change of variable proposed for the controller design, giving rise to a decoupled linear control. In this way, the strategy developed makes it possible to establish an adequate transient response for the converter in terms of convergence speed and overshoot magnitude, in addition to ensuring closed-loop system stability under bounded operating conditions. Unlike other proposals that utilize complex modulation strategies to control the MC under adverse conditions at the input terminals, in this case, the ability to generate fully controllable output voltages, regardless of the condition of the input signals, is provided by the designed linear controller. This allows the development of a multifunctional compensator with a simple control that could be of easy implementation. In order to verify the performance of the control strategy developed, and the effectiveness of the proposed DVR to mitigate the power quality problems already mentioned, several case studies are presented. The operational capacity of the MC is demonstrated by the obtained simulation results, which clearly reveals the capability of the DVR to eliminate voltage swells up to 50% and sags less than 50%. The compensation limit reached for sags is 37%. In relation to compensation for unbalanced voltage variations, the DVR manages to reduce the voltage imbalance from 11.11% to 0.37%. Finally, with regard to the operation of the DVR as an active voltage filter, the compensator is capable of reducing a THD of 20% calculated on the supply voltage, to a value of 1.53% measured at the load terminals. In the last two cases, the DVR mitigates disturbances to a level below the criteria established in the IEEE standard for power quality. Results obtained from numerical simulations performed in MATLAB/Simulink serve to validate the proposal, given that for each condition analyzed, the MC had succesfully generated the adequate compensation voltages, thus corroborating the robustness and effectiveness of the control strategy developed in this proposal. - 5 August 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (10) , 1603-1614
Comparative analysis to determine the accuracy of fractional derivatives in modeling supercapacitors
Summary: In this paper, we study a supercapacitor model represented by an equivalent RC circuit considering five different types of derivatives: Caputo, Caputo‐Fabrizio, and Atangana‐Baleanu fractional derivatives and the conformable and integer‐order derivatives. A set of experimental data from six commercial supercapacitors are used to estimate the parameter values for each derivative model by applying interior point optimization. The results show that the most accurate approach is achieved with the conformable derivative followed by the Caputo fractional derivative.
- 5 August 2019
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 47 (10) , 1603-1614
Comparative analysis to determine the accuracy of fractional derivatives in modeling supercapacitors
Summary: In this paper, we study a supercapacitor model represented by an equivalent RC circuit considering five different types of derivatives: Caputo, Caputo‐Fabrizio, and Atangana‐Baleanu fractional derivatives and the conformable and integer‐order derivatives. A set of experimental data from six commercial supercapacitors are used to estimate the parameter values for each derivative model by applying interior point optimization. The results show that the most accurate approach is achieved with the conformable derivative followed by the Caputo fractional derivative.
- Open Access
Optimal Energy Management within a Microgrid: A Comparative Study
In this work, we focus on optimal energy management within the context of the tertiary control of a microgrid operating in grid-connected mode. Specifically, the optimal energy management problem is solved in a unified way by using the optimal power flow (OPF) and day-ahead concepts. The elements considered in the microgrid are a photovoltaic panel, a wind turbine, electric vehicles, a storage system, and a point of common coupling with the main grid. The aim of this paper consists of optimizing the economic energy dispatch within the microgrid considering known predictions of electricity demand, solar radiation, and wind speed for a given period of time. The OPF is solved using three different algorithms provided by the optimization toolbox of MATLAB® (R2015a, MathWorks®, Natick, MA, USA): the interior point method (IP), a hybrid genetic algorithm with interior point (GA-IP), and a hybrid direct search with interior point (patternsearch-IP). The efficiency and effectiveness of the algorithms to optimize the energy dispatch within the microgrid are verified and analyzed through a case study, where real climatological data of solar irradiance, wind speed in Almería city, photovoltaic system data, and room load from a bioclimatic building were considered.
Open AccessOptimal Energy Management within a Microgrid: A Comparative Study
In this work, we focus on optimal energy management within the context of the tertiary control of a microgrid operating in grid-connected mode. Specifically, the optimal energy management problem is solved in a unified way by using the optimal power flow (OPF) and day-ahead concepts. The elements considered in the microgrid are a photovoltaic panel, a wind turbine, electric vehicles, a storage system, and a point of common coupling with the main grid. The aim of this paper consists of optimizing the economic energy dispatch within the microgrid considering known predictions of electricity demand, solar radiation, and wind speed for a given period of time. The OPF is solved using three different algorithms provided by the optimization toolbox of MATLAB® (R2015a, MathWorks®, Natick, MA, USA): the interior point method (IP), a hybrid genetic algorithm with interior point (GA-IP), and a hybrid direct search with interior point (patternsearch-IP). The efficiency and effectiveness of the algorithms to optimize the energy dispatch within the microgrid are verified and analyzed through a case study, where real climatological data of solar irradiance, wind speed in Almería city, photovoltaic system data, and room load from a bioclimatic building were considered.