Pieter A Breur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Pieter A Breur has a total of 593 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Tunnell
Department of Physics and Astronomy, Rice University, Houston, Texas 77005, USA
18 shared publications J. Masbou
18 shared publications- Jelle Aalbers
Nikhef and the University of Groningen, Van Swinderen Institute, 9747AG Groningen, Netherlands
18 shared publications - Rafael Florian Lang
Department of Physics and Astronomy, Purdue University, West Lafayette, Indiana 47907, USA
18 shared publications - Adriano Di Giovanni
Gran Sasso Science Institute (GSSI) Via Iacobucci 2 I-67100 L'Aquila Italy
17 shared publications - Alfredo Davide Ferella
INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, 67100 L’Aquila, Italy
17 shared publications
Latest Publications
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05019
Fiber-coupled digital photo sensors for large Time Projection Chambers
This paper presents a novel approach to addressing challenges in neutrino event reconstruction within large Time Projection Chambers (TPCs). By integrating fiber-coupled digital silicon photomultipliers, we propose a design that enhances light detection and improves both energy resolution and event reconstruction. Advancements in power and signal over fiber technologies are leveraged to deploy digital sensors within the TPC bulk volume, enabling precise timing and robust particle identification.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , C05019
Fiber-coupled digital photo sensors for large Time Projection Chambers
This paper presents a novel approach to addressing challenges in neutrino event reconstruction within large Time Projection Chambers (TPCs). By integrating fiber-coupled digital silicon photomultipliers, we propose a design that enhances light detection and improves both energy resolution and event reconstruction. Advancements in power and signal over fiber technologies are leveraged to deploy digital sensors within the TPC bulk volume, enabling precise timing and robust particle identification.
- Open Access
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- Open Access
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- Open Access
Acute Shortage Ventilator
We have implemented an “Acute Shortage Ventilator” (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.
Open AccessAcute Shortage Ventilator
We have implemented an “Acute Shortage Ventilator” (ASV) motivated by the COVID-19 pandemic and the possibility of severe ventilator shortages in the near future. The unit cost per ventilator is less than $400 US excluding the patient circuit parts. The ASV mechanically compresses a self-inflating bag resuscitator, uses a modified patient circuit, and is commanded by a microcontroller and an optional laptop. It operates in both Volume-Controlled Assist-Control mode and a Pressure-Controlled Assist-Control mode. It has been tested using an artificial lung against the EURS guidelines. The key design goals were to develop a simple device with high performance for short-term use, made primarily from common hospital parts and generally-available non-medical components, and at low cost and ease in manufacturing.
- 1 May 2020
- Published by Elsevier in Astroparticle Physics
- Vol. 119
Testing claims of the GW170817 binary neutron star inspiral affecting β-decay rates
- 1 May 2020
- Published by Elsevier in Astroparticle Physics
- Vol. 119
Testing claims of the GW170817 binary neutron star inspiral affecting β-decay rates
- Open Access
- 1 December 2018
- Published by Elsevier in Astroparticle Physics
- Vol. 103, 62-66
No correlation between Solar flares and the decay rate of several β-decaying isotopes
- 1 December 2018
- Published by Elsevier in Astroparticle Physics
- Vol. 103, 62-66
Open AccessNo correlation between Solar flares and the decay rate of several β-decaying isotopes
- Open Access
- 16 February 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (2) , 132
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
- 16 February 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (2) , 132
Open AccessIntrinsic backgrounds from Rn and Kr in the XENON100 experiment
- Open Access
- 19 December 2017
- Published by Springer Nature in The European Physical Journal C
- Vol. 77 (12) , 890
Material radioassay and selection for the XENON1T dark matter experiment
- 19 December 2017
- Published by Springer Nature in The European Physical Journal C
- Vol. 77 (12) , 890
Open AccessMaterial radioassay and selection for the XENON1T dark matter experiment